| Plan Review Stops For Permit 21030535 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2021-06-21 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-06-21 |
Time |
13:27 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-06-21 |
Time |
13:24 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2021-06-12 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-06-12 |
Time |
06:18 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-06-11 |
Time |
13:43 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2021-05-12 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-05-12 |
Time |
14:49 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-05-12 |
Time |
13:29 |
Sent To |
|
|
| Notes |
| 2021-05-12 14:52:19 | PLAN REVIEW BUILDING | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | PLANS EXAMINER PX3169 1&2 FAMILY - SFP306 | | | INSPECTOR BN4338 | | | BUILDING OFFICIAL BU1635 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | CODES IN EFFECT: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | 2017 NEC | | | | | | 2ND REVIEW | | | | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED | | | SATISFACTORILY ARE MARKED AS CORRECTED. | | | PREVIOUS COMMENTS THAT HAVE NOT BEEN ADDRESSED | | | SATISFACTORILY MAY HAVE ADDITIONAL COMMENTS IN | | | PARENTHESES. ANY NEW COMMENT WILL BE LISTED AFTER | | | PREVIOUS COMMENTS. | | | | | | | | | 1. PROVIDE A SITE DRAINAGE PLAN. CORRECTED | | | | | | | | | 2. PROVIDE DESIGN PRESSURES OF WINDOW AND DOOR | | | OPENINGS. CORRECTED | | | | | | | | | 3. PROVIDE PRODUCT APPROVALS FOR PROPOSED FRENCH DOORS. | | | CORRECTED | | | | | | | | | 4. PROVIDE ROOF SHEATHING FASTENER SCHEDULE. PLAN PAGE | | | S-2 REFERS TO DIAPHRAHM SCHEDULE. SCHEDULE MISSING FROM | | | SUBMITTAL. (NOT ADDRESSED) | | | TABLE R301.2(2) | | | COMPONENT AND CLADDING LOADS FOR A BUILDING WITH A MEAN | | | ROOF HEIGHT OF 30 FEET LOCATED IN EXPOSURE B (ASD) | | | (PSF)A, B, C, D, E, F | | | TABLE R301.2(3) | | | HEIGHT AND EXPOSURE ADJUSTMENT COEFFICIENTS FOR TABLE | | | R301.2(2) | | | FIGURE R301.2(7) | | | COMPONENT AND CLADDING PRESSURE ZONES | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2021-04-08 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-04-08 |
Time |
10:49 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-04-08 |
Time |
08:48 |
Sent To |
|
|
| Notes |
| 2021-04-08 10:56:06 | PLAN REVIEW BUILDING | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | PLANS EXAMINER PX3169 1&2 FAMILY - SFP306 | | | INSPECTOR BN4338 | | | BUILDING OFFICIAL BU1635 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | CODES IN EFFECT: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | 2017 NEC | | | | | | 1ST REVIEW | | | | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. PROVIDE A SITE DRAINAGE PLAN. | | | FBC R401.3 SITE DRAINAGE | | | PROVIDE A SITE DRAINAGE PLAN SHOWING COMPLIANCE WITH | | | FBC R401.3 DRAINAGE. | | | SURFACE DRAINAGE SHALL BE DIVERTED TO A STORM SEWER | | | CONVEYANCE OR OTHER APPROVED POINT OF COLLECTION THAT | | | DOES NOT CREATE A HAZARD. | | | LOTS SHALL BE GRADED TO DRAIN SURFACE WATER AWAY FROM | | | FOUNDATION WALLS. THE GRADE SHALL FALL A MINIMUM OF 6 | | | INCHES WITHIN THE FIRST 10 FEET. | | | | | | 2. PROVIDE DESIGN PRESSURES OF WINDOW AND DOOR | | | OPENINGS. | | | FBC 107.3.5.3 PROVIDE WIND DESIGN LOADS/DESIGN | | | PRESSURES PURSUANT TO FBC-R301.2. | | | | | | R301.2.1 WIND DESIGN CRITERIA. | | | BUILDINGS AND PORTIONS THEREOF SHALL BE CONSTRUCTED IN | | | ACCORDANCE WITH THE WIND PROVISIONS OF THIS CODE USING | | | THE BASIC WIND SPEED IN TABLE R301.2(1) AS DETERMINED | | | FROM FIGURE R301.2(4). | | | | | | NOTE: YOU MAY PROVIDE A SCHEDULE OF OPENINGS OR PLACE | | | THE DESIGN PRESSURES NEXT TO EACH OPENING ON YOUR PLAN. | | | | | | 3. PROVIDE PRODUCT APPROVALS FOR PROPOSED FRENCH DOORS. | | | FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE | | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | | | | 4. PROVIDE ROOF SHEATHING FASTENER SCHEDULE. PLAN PAGE | | | S-2 REFERS TO DIAPHRAHM SCHEDULE. SCHEDULE MISSING FROM | | | SUBMITTAL. | | | TABLE R301.2(2) | | | COMPONENT AND CLADDING LOADS FOR A BUILDING WITH A MEAN | | | ROOF HEIGHT OF 30 FEET LOCATED IN EXPOSURE B (ASD) | | | (PSF)A, B, C, D, E, F | | | TABLE R301.2(3) | | | HEIGHT AND EXPOSURE ADJUSTMENT COEFFICIENTS FOR TABLE | | | R301.2(2) | | | FIGURE R301.2(7) | | | COMPONENT AND CLADDING PRESSURE ZONES | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2021-03-29 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2021-03-29 |
Time |
13:22 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2021-03-29 |
Time |
13:11 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2021-07-21 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-07-21 |
Time |
06:14 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-07-16 |
Time |
07:10 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2021-07-08 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-07-08 |
Time |
16:21 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-07-01 |
Time |
09:50 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2021-06-24 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2021-06-24 |
Time |
10:45 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2021-06-14 |
Time |
15:15 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2021-06-12 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-06-12 |
Time |
06:19 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-05-18 |
Time |
07:23 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2021-05-12 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2021-05-12 |
Time |
14:56 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2021-04-26 |
Time |
09:10 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2021-04-08 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2021-04-08 |
Time |
12:16 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2021-03-15 |
Time |
11:19 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
P |
Date |
2021-07-08 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2021-07-08 |
Time |
16:27 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2021-06-14 |
Time |
15:15 |
Sent To |
|
|
| Notes |
| 2021-07-08 16:27:30 | RECEIPT MU-2021-30459 - $0.00 NO FEES DUE | | 2021-06-14 15:15:58 | 6/14/21 EMAILED IMPACT FEE OFFICE FOR REVIEW. LEM |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2021-04-08 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2021-04-08 |
Time |
12:16 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2021-04-08 |
Time |
12:16 |
Sent To |
|
|
| Notes |
| 2021-04-08 12:16:45 | PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE | | | DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS | | | OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST | | | FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE | | | OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL | | | IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME | | | THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM | | | CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS | | | TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF | | | | | | UPON APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE | | | RECEIPT TO YOUR PROJECT OR EMAIL IT TO | | | [email protected] . | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
6 |
Status |
P |
Date |
2021-07-21 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-07-21 |
Time |
06:14 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-07-21 |
Time |
06:06 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
5 |
Status |
F |
Date |
2021-07-08 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-07-08 |
Time |
16:17 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-07-08 |
Time |
16:17 |
Sent To |
|
|
| Notes |
| 2021-07-08 16:20:50 | THERE IS NO MECHANICAL SUB PERMIT FOR THIS PROJECT. I | | | CANNOT VERIFY THE PERSON THAT SIGNED THE EQUIPMENT | | | SIZING CALCULATIONS CAN SIZE THE DOCUMENT UNTIL THEY | | | HAVE APPLIED FOR THE MECHANICAL SUB PERMIT. | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
F |
Date |
2021-06-21 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-06-21 |
Time |
16:39 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-06-21 |
Time |
16:39 |
Sent To |
|
|
| Notes |
| 2021-06-21 16:44:19 | 1) PLEASE UNDERSTAND THAT MR. TSCHOSIK IS NOT A FLORIDA | | | LICENSED ENGINEER SO HE CANNOT BE THE DESIGNER OF | | | RECORD FOR THE MECHANICAL EQUIPMENT SIZING | | | CALCULATIONS. PLEASE HAVE A LICENSED ENGINEER, OR THE | | | ARCHITECT FOR THE PROJECT TO SIGN AND SEAL THE | | | MECHANICAL EQUIPMENT SIZING CALCULATIONS OR THE | | | MECHANICAL CONTRACTOR THAT HOLDS THE PERMIT TO INSTALL | | | THE MECHANICAL EQUIPMENT FOR THIS PROJECT TO PRINT | | | THEIR NAME AND SIGN THE DRAWING. F.S. 471.003 | | | | | | 2) PLEASE SHOW THE RETURN PATH FROM THE NEW ROOM TO THE | | | AHU. FBC RES M1602.3 | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
F |
Date |
2021-05-28 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-05-28 |
Time |
14:31 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-05-28 |
Time |
14:23 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2021-05-03 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-05-03 |
Time |
16:36 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-05-03 |
Time |
16:21 |
Sent To |
|
|
| Notes |
| 2021-05-03 16:37:00 | 2ND REVIEW FBC-2020 MECHANICAL | | | PERMIT-21030535 2ND REVIEW | | | | | | CODES IN EFFECT: | | | | | | FBC B- FLORIDA BUILDING CODE | | | FBC M- FLORIDA MECHANICAL CODE | | | FBC EC- FLORIDA ENERGY CONSERVATION | | | FBC FG- FLORIDA FUEL GAS | | | FBC EX- FLORIDA EXISTING BUILDING CODE | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) A MECHANICAL SUB-PERMIT IS REQUIRED. | | | | | | 2) FS 471.003 (H): THE MECHANICAL EQUIPMENT SIZING | | | CALCULATIONS ALONG WITH THE MECHANICAL SYSTEM DESIGN | | | MUST BE DESIGNED BY A FLORIDA LICENSED ENGINEER OR THE | | | MECHANICAL CONTRACTOR THAT HOLDS THE PERMIT FOR THE | | | SPECIFIC PROJECT WHICH HE OR SHE INSTALLS. | | | PLEASE, HAVE EITHER A LICENSED ENGINEER, PROVIDE A | | | SIGNED AND SEALED MECHANICAL EQUIPMENT SIZING | | | CALCULATION AND A SIGNED AND SEALED MECHANICAL DRAWING, | | | OR | | | THE MECHANICAL CONTRACTOR INSTALLING THE SYSTEM SHALL | | | PROVIDE THE EQUIPMENT SIZING CALCULATIONS AND A CODE | | | COMPLIANT DESIGN. CONTRACTOR SHALL INCLUDE HIS OR HER | | | PRINTED NAME AND SIGNATURE PER 2017 WPB AMENDMENTS TO | | | THE FLORIDA BUILDING CODE, CHAPTER 1, SECTION 107.2.1. | | | FBC 107.2.1 ALL INFORMATION, DRAWINGS, SPECIFICATIONS | | | AND ACCOMPANYING DATA SHALL BEAR THE NAME AND SIGNATURE | | | OF THE PERSON RESPONSIBLE FOR THE DESIGN. | | | 3) PLEASE SHOW THE RETURN AIR PATH FROM THE NEW ROOM | | | WITH DOORS TO THE EXISTING AHU RETURN. FBC RES M1602.3 | | | | | | THERE IS NO MECHANICAL SUB PERMIT FOR THIS JOB. | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM. | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2021-04-08 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-04-08 |
Time |
10:16 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-04-08 |
Time |
10:08 |
Sent To |
|
|
| Notes |
| 2021-04-08 10:19:39 | THE MECHANICAL EQUIPMENT SZING CALCULATIONS MUST BE | | | SUBMITTED BY THE MECHANICAL CONTRACTOR THAT SUBMITTED | | | THE DRAWING OF THE NEW MECHANICAL WORK BEING DONE. FS | | | 471.003 | | | | | | THE MECHANICAL DRAWING DOES NOT SHOW THE MECHANICAL | | | WORK BEING INSTALL IN THE SECOND ADDITION. PLEASE | | | UPDATE THE MECHANICAL DRAWING FROM THE MECHANICAL | | | CONTRACTOR SHOWING THE NEW WORK BEING INSTALLED IN BOTH | | | NEW ADDITIONS. FBC 107.2.1 | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
3 |
Status |
P |
Date |
2021-06-12 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-06-12 |
Time |
06:06 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-06-11 |
Time |
13:43 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
2 |
Status |
F |
Date |
2021-05-12 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-05-12 |
Time |
14:52 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-05-12 |
Time |
13:29 |
Sent To |
|
|
| Notes |
| 2021-05-12 14:54:31 | PLAN REVIEW / ROOFING | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | PLANS EXAMINER PX3169 / 1&2 FAMILY SFP306 | | | INSPECTOR BN4338 | | | BUILDING OFFICIAL BU1635 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | CODES IN EFFECT: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | 2017 NEC | | | | | | | | | 2ND REVIEW | | | | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1.ROOFING PERMIT REQUIRED. CORRECTED | | | | | | 2. PROVIDE PRODUCT APPROVALS FOR ROOFING SYSTEM | | | COMPONENTS. (SELECT MODEL OF TILE TO BE INSTALLED FROM | | | FL7849-R13. PROVIDE INSTALLATION INSTRUCTIONS FOR | | | SELECTED TILE) | | | FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE | | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | SPECIFICALLY, PROVIDE ROOFING SUBMITTALS. | | | | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2021-04-08 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-04-08 |
Time |
10:37 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-04-08 |
Time |
08:48 |
Sent To |
|
|
| Notes |
| 2021-04-08 10:42:45 | PLAN REVIEW / ROOFING | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | PLANS EXAMINER PX3169 / 1&2 FAMILY SFP306 | | | INSPECTOR BN4338 | | | BUILDING OFFICIAL BU1635 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | CODES IN EFFECT: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | 2017 NEC | | | | | | | | | 1ST REVIEW | | | | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1.ROOFING PERMIT REQUIRED. | | | PERMITS - 105.1 REQUIRED. | | | | | | 2. PROVIDE PRODUCT APPROVALS FOR ROOFING SYSTEM | | | COMPONENTS. | | | FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE | | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | SPECIFICALLY, PROVIDE ROOFING SUBMITTALS. | | | | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
4 |
Status |
P |
Date |
2021-06-21 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-06-21 |
Time |
13:24 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-06-21 |
Time |
13:24 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
P |
Date |
2021-05-28 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-05-28 |
Time |
14:37 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-05-28 |
Time |
14:37 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2021-05-03 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-05-03 |
Time |
16:38 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-05-03 |
Time |
16:38 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2021-04-08 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-04-08 |
Time |
10:36 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-04-08 |
Time |
08:48 |
Sent To |
|
|
| Notes |
| 2021-04-08 10:37:01 | SEE SIGNATURE FILE. CT |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
4 |
Status |
P |
Date |
2021-06-23 |
|
|
Cont ID |
|
| Sent By |
llouie |
Date |
2021-06-23 |
Time |
|
Rev Time |
0.00 |
| Received By |
llouie |
Date |
2021-06-23 |
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2021-05-26 |
|
|
Cont ID |
|
| Sent By |
llouie |
Date |
2021-05-26 |
Time |
|
Rev Time |
0.00 |
| Received By |
llouie |
Date |
2021-05-26 |
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2021-04-30 |
|
|
Cont ID |
|
| Sent By |
llouie |
Date |
2021-04-30 |
Time |
|
Rev Time |
0.00 |
| Received By |
llouie |
Date |
2021-04-30 |
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2021-03-30 |
|
|
Cont ID |
|
| Sent By |
llouie |
Date |
2021-03-30 |
Time |
|
Rev Time |
|
| Received By |
llouie |
Date |
2021-03-30 |
Time |
|
Sent To |
|
|
| Notes |
| 2021-03-30 08:47:29 | ** FAILED ** | | | | | | PLEASE ADDRESS THE FOLLOWING COMMENTS. RESPOND TO THE | | | COMMENTS IN WRITING AND/OR ON THE PLANS WHERE | | | APPLICABLE: | | | | | | 1.) SIGNED AND SEALED SURVEY OF THE PROPERTY IS | | | REQUIRED. A SURVEY WAS NOT PROVIDED WITH THE PERMIT | | | SUBMITTAL. | | | | | | 2.) PROVIDE A SITE PLAN SHOWING THE PROPOSED ADDITION | | | AND SETBACK DISTANCE FROM THE PROPERTY LINE(S). | | | | | | 3.) PLEASE CLARIFY THE LABELING OF THE REAR ELEVATION | | | (IS IT THE EXISTING OR PROPOSED REAR ELEVATION? IT IS | | | CURRENTLY LABELED EXISTING). THE PROPOSED REAR | | | ELEVATION WILL NEED TO BE PROVIDED WITH THE PERMIT | | | SUBMITTAL. | | | | | | | | | NOTES: | | | | | | * VALUE OF THE SCOPE ($105,000) DOES NOT EXCEED 50% | | | VALUE OF STRUCTURE PER 2020 PAPA VALUE ($264,912). | | | | | | * ANY REVISIONS MAY RESULT IN ADDITIONAL COMMENTS. | | | | | | * CONTACT LINDA LOUIE @ (561) 822-1458 IF THERE ARE | | | QUESTIONS. | | | | | | * ZONE: RPD (SFR, IBIS GOLF AND COUNTRY CLUB) | | | |
|
|