Plan Review Details - Permit 21030412
Plan Review Stops For Permit 21030412
Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 3 Status P Date 2021-05-14 Cont ID  
Sent By equinone Date 2021-05-14 Time 09:44 Rev Time 0.00
Received By equinone Date 2021-05-14 Time 09:44 Sent To  
Notes
2021-05-14 09:44:57ASBESTOS LETTER RECEIVED AND UPLOADED. EQ

Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 2 Status F Date 2021-05-10 Cont ID  
Sent By jwitmer Date 2021-05-10 Time 09:30 Rev Time 0.00
Received By jwitmer Date 2021-05-10 Time 09:02 Sent To  
Notes
2021-05-10 09:31:44TO THE BUILDING CONTRACTOR:
 PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE
 CONTRACTOR, ON LETTERHEAD, STATING THAT THE
 INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM
 COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH
 COUNTY WILL BE FOLLOWED, AND THAT NOTIFICATION WILL BE
 GIVEN TIMELY. ADDITIONAL INFORMATION REGARDING ASBESTOS
 REQUIREMENTS CAN BE FOUND ON THEIR WEBSITE:
  
 HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE
 S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION-
 RENOVATION.HTML
  
 THE CONTRACTOR ACKNOWLEDGEMENT CAN BE SENT VIA EMAIL TO
 [email protected]. THE INFORMATION SHOULD BE IN PDF
 FORMAT AS AN ATTACHMENT TO THE EMAIL. PLEASE INCLUDE
 THE PERMIT NUMBER AND "ASBESTOS" IN THE SUBJECT LINE.

Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 1 Status F Date 2021-03-21 Cont ID  
Sent By jwitmer Date 2021-03-21 Time 14:45 Rev Time 0.00
Received By jwitmer Date 2021-03-21 Time 13:32 Sent To  
Notes
2021-03-21 14:44:57TO THE BUILDING CONTRACTOR:
 PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE
 CONTRACTOR, ON LETTERHEAD, STATING THAT THE
 INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM
 COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH
 COUNTY WILL BE FOLLOWED, AND THAT NOTIFICATION WILL BE
 GIVEN TIMELY. ADDITIONAL INFORMATION REGARDING ASBESTOS
 REQUIREMENTS CAN BE FOUND ON THEIR WEBSITE:
  
 HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE
 S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION-
 RENOVATION.HTML
  
 THE CONTRACTOR ACKNOWLEDGEMENT CAN BE SENT VIA EMAIL TO
 [email protected]. THE INFORMATION SHOULD BE IN PDF
 FORMAT AS AN ATTACHMENT TO THE EMAIL. PLEASE INCLUDE
 THE PERMIT NUMBER AND "ASBESTOS" IN THE SUBJECT LINE.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2021-06-18 Cont ID  
Sent By pvalenti Date 2021-06-18 Time 06:45 Rev Time 0.00
Received By pvalenti Date 2021-06-18 Time 06:40 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2021-05-11 Cont ID  
Sent By jwitmer Date 2021-05-11 Time 11:59 Rev Time 0.00
Received By jwitmer Date 2021-05-11 Time 11:29 Sent To  
Notes
2021-05-11 11:52:38PASSED SHEET A-1 EXISTING PLAN SHOWING IN THE MASTER
 BATH THE REPLACEMENT OF EXISTING TUB AS PER RESPONSE
 LETTER FROM BUNKER ENGINEERING DATED APRIL 28/2021.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2021-05-10 Cont ID  
Sent By jwitmer Date 2021-05-10 Time 09:31 Rev Time 0.00
Received By jwitmer Date 2021-05-10 Time 09:03 Sent To  
Notes
2021-05-10 09:33:05WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION
 SERVICES/ BUILDING DIVISION
 2020 FBC- BUILDING PLAN REVIEW
 W. P. B. PERMIT: 21030412
 ADD: 2427 PRESIDENTIAL WAY # 904
 CONT: MAKI CONSTRUCTION
 TEL: 561-644-1107
 E-MAIL: [email protected]
  
 2020 FLORIDA BUILDING CODE W 2020 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2020 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW
 CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES
 SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA
 BUILDING CODE, BUILDING.
  
 2ND REVIEW
 DATE: MON. MAY 10TH/ 2021
 ACTION: DENIED
 NOTICE: THE ORIGINAL PLANS MARCH 5TH WERE RESUBMITTED
 WITH NO CHANGES ONLY A LETTER FROM THE BUNKER
 ENGINEERING & CONSTRUCTION THE PLANS SHEET A.1 OR A,2
 WERE NOT UPDATED. NO REVISION IN THE REVISION BOX AND
 NO VERSIONING OCCURRED VERSION 1 VERSES VERSION 2.
 4X FEE / NOTICE!!!!! FLORIDA STATUTE 553.80(2)(B) WITH
 RESPECT TO EVALUATION OF DESIGN PROFESSIONALS?
 DOCUMENTS, IF A LOCAL GOVERNMENT FINDS IT NECESSARY, IN
 ORDER TO ENFORCE COMPLIANCE WITH THE FLORIDA BUILDING
 CODE AND ISSUE A PERMIT, TO REJECT DESIGN DOCUMENTS
 REQUIRED BY THE CODE THREE OR MORE TIMES FOR FAILURE TO
 CORRECT A CODE VIOLATION SPECIFICALLY AND CONTINUOUSLY
 NOTED IN EACH REJECTION, INCLUDING, BUT NOT LIMITED TO,
 EGRESS, FIRE PROTECTION, STRUCTURAL STABILITY, ENERGY,
 ACCESSIBILITY, LIGHTING, VENTILATION, ELECTRICAL,
 MECHANICAL, PLUMBING, AND GAS SYSTEMS, OR OTHER
 REQUIREMENTS IDENTIFIED BY RULE OF THE FLORIDA BUILDING
 COMMISSION ADOPTED PURSUANT TO CHAPTER 120, THE LOCAL
 GOVERNMENT SHALL IMPOSE, EACH TIME AFTER THE THIRD SUCH
 REVIEW THE PLANS ARE REJECTED FOR THAT CODE VIOLATION,
 A FEE OF FOUR TIMES THE AMOUNT OF THE PROPORTION OF THE
 PERMIT FEE ATTRIBUTED TO PLANS REVIEW.
 2ND REQUEST FOR ALL COMMENTS!!!!!!!
  
 1) SHEET A-2
 1A) THE MASTER BATH SHOWS THE REMOVAL OF A TUB AND IN
 GLASS A NEW DOORLESS SHOWER. THERE ARE NO PLUMBING
 PLANS AND THE FLOOR PLAN DOES NOT INDICATE IF THE OLD
 DRAIN LOCATION IS GOING TO BE USED FOR THE NEW SHOWER.
  
 POST TENSION SLAB/ NEW HOLES. THE PLAN IS SILENT AS IF
 THE LOCATION OF THE EXISTING TUB DRAIN IS GOING TO BE
 REUSED IN THE SAME LOCATION. IF NOT, THEN THE FLOOR
 SLAB WILL NEED TO BE X-RAYED TO FIND THE POST TENSION
 CHORD LOCATIONS. 107.2.1.2. ADDITIONAL INFORMATION IS
 REQUIRED.
  
 1B) NEW FLOOR PENETRATIONS. THROUGH-PENETRATIONS
 FIRESTOP SYSTEMS (HORIZONTAL ASSEMBLIES). IF A NEW
 FLOOR PENETRATION IS MADE FOR THE FUTURE SHOWER DRAIN,
 THEN YOU NEED TO SHOW COMPLIANCE WITH THE 2020 FBC-B
 SECTION 714.5.1.2. THROUGH-PENETRATIONS FIRESTOP
 SYSTEMS (HORIZONTAL ASSEMBLIES). THROUGH PENETRATIONS
 SHALL BE PROTECTED BY A THROUGH PENETRATION FIRESTOP
 SYSTEM INSTALLED IN ACCORDANCE WITH ASTM E814 OR UL
 1479. THE SYSTEM SHALL HAVE AN F RATING / T RATING OF
 NOT LESS THAN 1 HOUR BUT NOT LESS THAN THE REQUIRED
 RATING OF THE FLOOR PENETRATED.
  
 1C) THE NEW DOORLESS SHOWER DOES NOT STATE THE TYPE OF
 BACKING MATERIAL TO BE INSTALLED IN THE SHOWER.
 2020 FBC-B 2509.2 BASE FOR TILE. MATERIALS USED AS A
 BASE FOR WALL TILE IN TUB AND SHOWER AREAS AND WALLS
 AND CEILING PANELS IN SHOWER AREAS SHALL BE OF
 MATERIALS LISTED IN TABLE 2509.2 AND INSTALLED IN
 ACCORDANCE WITH MANUFACTURERS RECOMMENDATIONS. WATER
 RESISTANT GYPSUM BACKING BOARD SHALL BE USED AS A BASE
 FOR TILE IN WATER CLOSET COMPARTMENT WALLS WHEN
 INSTALLED IN ACCORDANCE WITH GA-216 OR ASTM C840 AND
 THE MANUFACTURERS RECOMMENDATIONS.
  
 1D) THE FLOOR PLAN DOES NOT PROVIDE THE HEIGHT OF THE
 FINISH MATERIAL IN THE SHOWER NOR TYPE OF MATERIAL..
 2020 FBC-B SHOWERS & TUBS 1210.3. SHOWER COMPARTMENTS
 AND BATHTUBS WITH INSTALLED SHOWER HEADS SHALL BE
 FINISHED WITH A NONABSORBENT SURFACE TO A HEIGHT NOT
 LESS THAN 72 INCHES ABOVE THE DRAIN INLET.
  
 1E) THE PLANS ARE SILENT AS IF THERE IS TO BE A CURB IN
 THE SHOWER, PLEASE PROVIDE DETAIL OF CURB. IF NO CURB
 HOW WILL THE WATER BE RETAINED IN THE SHOWER
 COMPARTMENT WITHOUT SHOWER DOORS. 107.2.1.2. ADDITIONAL
 INFORMATION IS REQUIRED.
  
 2) SHEET A-1 DEMOLITION:
 2A) DESIGN CRITERIA: LIST THE OCCUPANCY TYPE AS R-3 A
 SINGLE FAMILY DWELLING TYPE. PLEASE NOTE IN THE 2020
 FBC-B SECTION 310.4 WOULD CATEGORIZE THIS OCCUPANCY AS
 R-2 APARTMENT- NON-TRANSIENT OR CONDOMINIUMS.
  
 2B) DESIGN CRITERIA: LIST THE CONSTRUCTION TYPE AS 5-B.
 PLEASE NOTE THIS BUILDING IS A 24 STORY HIGHRISE AND
 BUILDING TYPE IS I-A. 2020 FBC-B TABLE 504.3 & TABLE
 504.4.
  
 3) SHEET A-1 THE DEMOLITION SHEET NOTE 11 STATES
 INSTALL NEW FLOORING WITH SOUND PROOFING IN THE MASTER
 BEDROOM, BATHROOM, BEDROOM #3, KITCHEN AND MASTER
 BATHROOM. THE PLANS DO NOT STATE WHAT TYPE OF FLOOR
 FINISH MATERIAL IS TO BE INSTALLED.
 FLOOR INSULATION (FBC-B 2020) FOR TILE, STONE, MARBLE,
 VINYL AND WOOD FLOORING ALL NEED TO HAVE HAD THE SOUND
 UNDERLAYMENT TESTED FLOOR ASSEMBLIES TO THE FOLLOWING
 STANDARDS AND MEET THE QUALIFICATIONS LISTED UNDER EACH
 OF THE STANDARDS FOR A 6 INCH CONCRETE FLOOR ASSEMBLY/
 NO DROPPED CEILING:
 PLEASE PROVIDE ALL THREE TEST REPORTS FOR TYPE I AND OR
 TYPE II BUILDINGS SHOWING COMPLIANCE WITH:
  
 3A) FBC-B 2020 1207.3 STRUCTURE-BORNE SOUND.
 FLOOR/CEILING ASSEMBLIES BETWEEN DWELLING UNITS OR
 BETWEEN A DWELLING UNIT AND A PUBLIC OR SERVICE AREA
 WITHIN THE STRUCTURE SHALL HAVE AN IMPACT INSULATION
 CLASS (IIC) RATING OF NOT LESS THAN 50 (45 IF FIELD
 TESTED) WHEN TESTED IN ACCORDANCE WITH ASTM E-492.
  
 3B) FBC-B 2020 1207.2 AIR-BORNE SOUND. WALLS,
 PARTITIONS AND FLOOR/CEILING ASSEMBLIES SEPARATING
 DWELLING UNITS FROM EACH OTHER OR FROM PUBLIC OR
 SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION CLASS
 (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED) FOR
 AIR-BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM E
 90.
  
 3C) FLAME SPREAD- FBC-B 2020 603.1. EXCEPTION 2.
 INSULATION INSTALLED BETWEEN A FINISHED FLOOR AND SOLID
 DECKING WITHOUT INTERVENING AIRSPACE SHALL BE ALLOWED
 TO HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 200.
  
 FLAME SPREAD INDEX. A COMPARATIVE MEASURE, EXPRESSED AS
 A DIMENSIONLESS NUMBER, DERIVED FROM VISUAL
 MEASUREMENTS OF THE SPREAD OF FLAME VERSUS TIME FOR A
 MATERIAL TESTED IN ACCORDANCE WITH ASTM E 84 OR UL 723.
  
 LVT & LPT LUXURY VINYL TILE. FLOOR FINISH
 CLASSIFICATION AS REQUIRED IN SECTION 804.2
 CLASSIFICATION AND 804.3 TESTING AND IDENTIFICATION OF
 THE 2020 FBC-B.
  
 4) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 PLEASE NOTE WITH THE LACK OF INFORMATION FOR THIS
 REVIEW, SUBSEQUENT REMARKS MAYBE MADE IN THE NEXT
 REVIEW CYCLE.
  
 PLEASE NOTE WE ARE WORKING FROM HOME BECAUSE OF COVID
 19
 IF YOU WOULD LIKE TO CONTACT ME, MY CELL NUMBER IS
 561-718-9724.
 WORKING HOURS ARE MON.- WED. 8:00 AM- NOON. PART-TIME/
 RETIRED.
  
 JAMES A. WITMER BN, PX, SFP, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2021-03-21 Cont ID  
Sent By jwitmer Date 2021-03-21 Time 14:44 Rev Time 0.00
Received By jwitmer Date 2021-03-21 Time 13:33 Sent To  
Notes
2021-03-21 14:44:04WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION
 SERVICES/ BUILDING DIVISION
 2020 FBC- BUILDING PLAN REVIEW
 W. P. B. PERMIT: 21030412
 ADD: 2427 PRESIDENTIAL WAY # 904
 CONT: MAKI CONSTRUCTION
 TEL: 561-644-1107
 E-MAIL: [email protected]
  
 2020 FLORIDA BUILDING CODE W 2020 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2020 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW
 CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES
 SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA
 BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: SUNDAY MARCH 21ST/ 2021
 ACTION: DENIED
  
 1) SHEET A-2
 1A) THE MASTER BATH SHOWS THE REMOVAL OF A TUB AND IN
 GLASS A NEW DOORLESS SHOWER. THERE ARE NO PLUMBING
 PLANS AND THE FLOOR PLAN DOES NOT INDICATE IF THE OLD
 DRAIN LOCATION IS GOING TO BE USED FOR THE NEW SHOWER.
  
 POST TENSION SLAB/ NEW HOLES. THE PLAN IS SILENT AS IF
 THE LOCATION OF THE EXISTING TUB DRAIN IS GOING TO BE
 REUSED IN THE SAME LOCATION. IF NOT, THEN THE FLOOR
 SLAB WILL NEED TO BE X-RAYED TO FIND THE POST TENSION
 CHORD LOCATIONS. 107.2.1.2. ADDITIONAL INFORMATION IS
 REQUIRED.
  
 1B) NEW FLOOR PENETRATIONS. THROUGH-PENETRATIONS
 FIRESTOP SYSTEMS (HORIZONTAL ASSEMBLIES). IF A NEW
 FLOOR PENETRATION IS MADE FOR THE FUTURE SHOWER DRAIN,
 THEN YOU NEED TO SHOW COMPLIANCE WITH THE 2020 FBC-B
 SECTION 714.5.1.2. THROUGH-PENETRATIONS FIRESTOP
 SYSTEMS (HORIZONTAL ASSEMBLIES). THROUGH PENETRATIONS
 SHALL BE PROTECTED BY A THROUGH PENETRATION FIRESTOP
 SYSTEM INSTALLED IN ACCORDANCE WITH ASTM E814 OR UL
 1479. THE SYSTEM SHALL HAVE AN F RATING / T RATING OF
 NOT LESS THAN 1 HOUR BUT NOT LESS THAN THE REQUIRED
 RATING OF THE FLOOR PENETRATED.
  
 1C) THE NEW DOORLESS SHOWER DOES NOT STATE THE TYPE OF
 BACKING MATERIAL TO BE INSTALLED IN THE SHOWER.
 2020 FBC-B 2509.2 BASE FOR TILE. MATERIALS USED AS A
 BASE FOR WALL TILE IN TUB AND SHOWER AREAS AND WALLS
 AND CEILING PANELS IN SHOWER AREAS SHALL BE OF
 MATERIALS LISTED IN TABLE 2509.2 AND INSTALLED IN
 ACCORDANCE WITH MANUFACTURER?S RECOMMENDATIONS. WATER
 RESISTANT GYPSUM BACKING BOARD SHALL BE USED AS A BASE
 FOR TILE IN WATER CLOSET COMPARTMENT WALLS WHEN
 INSTALLED IN ACCORDANCE WITH GA-216 OR ASTM C840 AND
 THE MANUFACTURE?S RECOMMENDATIONS.
  
 1D) THE FLOOR PLAN DOES NOT PROVIDE THE HEIGHT OF THE
 FINISH MATERIAL IN THE SHOWER NOR TYPE OF MATERIAL..
 2020 FBC-B SHOWERS & TUBS 1210.3. SHOWER COMPARTMENTS
 AND BATHTUBS WITH INSTALLED SHOWER HEADS SHALL BE
 FINISHED WITH A NONABSORBENT SURFACE TO A HEIGHT NOT
 LESS THAN 72 INCHES ABOVE THE DRAIN INLET.
  
 1E) THE PLANS ARE SILENT AS IF THERE IS TO BE A CURB IN
 THE SHOWER, PLEASE PROVIDE DETAIL OF CURB. IF NO CURB
 HOW WILL THE WATER BE RETAINED IN THE SHOWER
 COMPARTMENT WITHOUT SHOWER DOORS. 107.2.1.2. ADDITIONAL
 INFORMATION IS REQUIRED.
  
 2) SHEET A-1 DEMOLITION:
 2A) DESIGN CRITERIA: LIST THE OCCUPANCY TYPE AS R-3 A
 SINGLE FAMILY DWELLING TYPE. PLEASE NOTE IN THE 2020
 FBC-B SECTION 310.4 WOULD CATEGORIZE THIS OCCUPANCY AS
 R-2 APARTMENT- NON-TRANSIENT OR CONDOMINIUMS.
  
 2B) DESIGN CRITERIA: LIST THE CONSTRUCTION TYPE AS 5-B.
 PLEASE NOTE THIS BUILDING IS A 24 STORY HIGHRISE AND
 BUILDING TYPE IS I-A. 2020 FBC-B TABLE 504.3 & TABLE
 504.4.
  
 3) SHEET A-1 THE DEMOLITION SHEET NOTE 11 STATES
 INSTALL NEW FLOORING WITH SOUND PROOFING IN THE MASTER
 BEDROOM, BATHROOM, BEDROOM #3, KITCHEN AND MASTER
 BATHROOM. THE PLANS DO NOT STATE WHAT TYPE OF FLOOR
 FINISH MATERIAL IS TO BE INSTALLED.
 FLOOR INSULATION (FBC-B 2020) FOR TILE, STONE, MARBLE,
 VINYL AND WOOD FLOORING ALL NEED TO HAVE HAD THE SOUND
 UNDERLAYMENT TESTED FLOOR ASSEMBLIES TO THE FOLLOWING
 STANDARDS AND MEET THE QUALIFICATIONS LISTED UNDER EACH
 OF THE STANDARDS FOR A 6 INCH CONCRETE FLOOR ASSEMBLY/
 NO DROPPED CEILING:
 PLEASE PROVIDE ALL THREE TEST REPORTS FOR TYPE I AND OR
 TYPE II BUILDINGS SHOWING COMPLIANCE WITH:
  
 3A) FBC-B 2020 1207.3 STRUCTURE-BORNE SOUND.
 FLOOR/CEILING ASSEMBLIES BETWEEN DWELLING UNITS OR
 BETWEEN A DWELLING UNIT AND A PUBLIC OR SERVICE AREA
 WITHIN THE STRUCTURE SHALL HAVE AN IMPACT INSULATION
 CLASS (IIC) RATING OF NOT LESS THAN 50 (45 IF FIELD
 TESTED) WHEN TESTED IN ACCORDANCE WITH ASTM E-492.
  
 3B) FBC-B 2020 1207.2 AIR-BORNE SOUND. WALLS,
 PARTITIONS AND FLOOR/CEILING ASSEMBLIES SEPARATING
 DWELLING UNITS FROM EACH OTHER OR FROM PUBLIC OR
 SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION CLASS
 (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED) FOR
 AIR-BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM E
 90.
  
 3C) FLAME SPREAD- FBC-B 2020 603.1. EXCEPTION 2.
 INSULATION INSTALLED BETWEEN A FINISHED FLOOR AND SOLID
 DECKING WITHOUT INTERVENING AIRSPACE SHALL BE ALLOWED
 TO HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 200.
  
 FLAME SPREAD INDEX. A COMPARATIVE MEASURE, EXPRESSED AS
 A DIMENSIONLESS NUMBER, DERIVED FROM VISUAL
 MEASUREMENTS OF THE SPREAD OF FLAME VERSUS TIME FOR A
 MATERIAL TESTED IN ACCORDANCE WITH ASTM E 84 OR UL 723.
  
 LVT & LPT LUXURY VINYL TILE. FLOOR FINISH
 CLASSIFICATION AS REQUIRED IN SECTION 804.2
 CLASSIFICATION AND 804.3 TESTING AND IDENTIFICATION OF
 THE 2020 FBC-B.
  
 4) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 PLEASE NOTE WITH THE LACK OF INFORMATION FOR THIS
 REVIEW, SUBSEQUENT REMARKS MAYBE MADE IN THE NEXT
 REVIEW CYCLE.
  
 PLEASE NOTE WE ARE WORKING FROM HOME BECAUSE OF COVID
 19
 IF YOU WOULD LIKE TO CONTACT ME, MY CELL NUMBER IS
 561-718-9724.
 WORKING HOURS ARE MON.- WED. 8:00 AM- NOON. PART-TIME/
 RETIRED.
  
 JAMES A. WITMER BN, PX, SFP, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2021-05-14 Cont ID  
Sent By equinone Date 2021-05-14 Time 09:18 Rev Time 0.00
Received By equinone Date 2021-05-14 Time 09:18 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2021-03-25 Cont ID  
Sent By equinone Date 2021-03-25 Time 14:48 Rev Time 0.00
Received By equinone Date 2021-03-25 Time 14:47 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2021-03-16 Cont ID  
Sent By pleduc Date 2021-03-16 Time   Rev Time 0.00
Received By pleduc Date 2021-03-16 Time 16:32 Sent To  
Notes
2021-03-16 16:39:04THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC,
 FIRE MARSHAL, WITH THE FOLLOWING COMMENTS:
  
 PLEASE CONSIDER THE FOLLOWING AS PROVISO:
  
 THESE PROVISO COMMENTS WILL BE VERIFIED AND CONFIRMED
 AT THE TIME OF FIRE INSPECTION. FAILURE TO FOLLOW THESE
 PROVISO COMMENTS WILL RESULT IN A FAILED FIRE
 INSPECTION.
  
 1) ANY REMOVAL AND/OR CONSTRUCTION OF THE CEILING/WALL
 AREAS MAY REQUIRE AN EVALUATION OR MODIFICATION OF THE
 FIRE SPRINKLER AND FIRE ALARM SYSTEMS FOR CODE COVERAGE
 AND COMPLIANCE BY CERTIFIED CONTRACTORS.
  
 2) ANY AND ALL WORK ON THE FIRE SPRINKLER AND/OR FIRE
 ALARM SYSTEMS SHALL BE DONE UNDER SEPARATE PERMITS AND
 SHOP DRAWINGS BY CERTIFIED CONTRACTORS.
  
 3) THE FIRE SPRINKLER AND FIRE ALARM SYSTEMS SHALL
 REMAIN ACTIVE THROUGHOUT THE DEMO AND CONSTRUCTION
 PERIODS.
  
  
 PETER LEDUC
 FIRE MARSHAL
 WEST PALM BEACH FIRE RESCUE
 561-804-4709
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2021-06-22 Cont ID  
Sent By lcrespo Date 2021-06-22 Time 13:52 Rev Time 0.00
Received By lcrespo Date 2021-06-17 Time 12:59 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2021-05-14 Cont ID  
Sent By equinone Date 2021-05-14 Time 09:45 Rev Time 0.00
Received By equinone Date 2021-05-07 Time 12:45 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2021-04-01 Cont ID  
Sent By jesmith Date 2021-04-01 Time 16:27 Rev Time 0.00
Received By jesmith Date 2021-04-01 Time 16:27 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status P Date 2021-06-22 Cont ID  
Sent By lcrespo Date 2021-06-22 Time 13:52 Rev Time 0.00
Received By lcrespo Date 2021-06-22 Time 13:51 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2021-05-13 Cont ID  
Sent By jesmith Date 2021-05-13 Time 16:01 Rev Time 0.00
Received By jesmith Date 2021-05-13 Time 16:00 Sent To  
Notes
2021-05-13 16:00:55CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2020 7TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1
 WPB CCCM=WEST PALM BEACH CROSS-CONNECTION CONTROL
 MANUAL REVISED 2017
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020
 7TH EDITION
 FBC RES = FLORIDA RESIDENTIAL CODE 2020 7TH EDITION
 FBC EX = FLORIDA EXISTING BUILDING CODE 2020 7TH
 EDITION
 FBC PL = FLORIDA PLUMBING CODE 2020 7TH EDITION
 FAC= FLORIDA ADMINISTRATIVE CODE
 FS = FLORIDA STATUTES
  
 21030412 2427 PRESIDENTIAL WAY # 904
  
 2ND REVIEW
 PLUMBING COMMENTS: DENIED
 1.RESPONSE PROVIDED; NONE. 2ND REQUEST. BUILDING HAS
 TWENTY FOUR FLOORS (BRANCH INTERVALS); UNIT IS ON THE
 NINTH FLOOR (BRANCH INTERVAL). PER FBC PL 918.3.1,
 INDIVIDUAL AND BRANCH-TYPE AIR ADMITTANCE VALVES SHALL
 VENT ONLY FIXTURES THAT ARE ON THE SAME FLOOR LEVEL AND
 CONNECT TO A HORIZONTAL BRANCH DRAIN. WHERE THE
 HORIZONTAL BRANCH IS LOCATED MORE THAN FOUR BRANCH
 INTERVALS FROM THE TOP OF THE STACK, THE HORIZONTAL
 BRANCH SHALL BE PROVIDED WITH A RELIEF VENT THAT SHALL
 CONNECT TO A VENT STACK OR STACK VENT, OR EXTEND
 OUTDOORS TO THE OPEN AIR. THE RELIEF VENT SHALL CONNECT
 TO THE HORIZONTAL BRANCH DRAIN BETWEEN THE STACK AND
 THE MOST DOWNSTREAM FIXTURE DRAIN CONNECTED TO THE
 HORIZONTAL BRANCH DRAIN. THE RELIEF VENT SHALL BE SIZED
 IN ACCORDANCE WITH SECTION 906.2 AND INSTALLED IN
 ACCORDANCE WITH SECTION 905. THE RELIEF VENT SHALL BE
 PERMITTED TO SERVE AS THE VENT FOR OTHER FIXTURES.
 NEW COMMENT: TO BE CLEAR, THE AIR ADMITTANCE VALVE AT
 THE KITCHEN SINK SANITARY RISER DIAGRAM DOES NOT
 COMPLY.
  
 2.RESPONSE PROVIDED; NO CHANGE IN CONFIGURATION OF TUB
 AND SHOWER. THE EXISTING TUB WILL BE REPLACED BY A NEW
 TUB OF THE SAME CONFIGURATION; THE SHOWER WALLS REMAIN
 AS IS AND THE EXISTING DRAIN SHALL BE USED. P.1
 SANITARY ISOMETRIC INDICATES EXTENSION OF HORIZONTAL
 FIXTURE DRAIN PIPING TO NEW THROUGH THE SLAB LOCATIONS
 FOR THE NEW WALK-IN BATHTUB AND SHOWER. PER WPB FBC
 107.2.1, PROVIDE DETAIL FOR NEW THROUGH THE FLOOR
 PENETRATIONS SHOWING COMPLIANCE WITH FBC CHAPTER 7
 REGARDING FIRESTOP OF PENETRATIONS.
 NEW COMMENT:
 A) A2 ARCHITECTURAL STILL SHOWS THE WALK-IN TUB AND THE
 DOORLESS SHOWER IN THE MASTER BATHROOM. PER WPB FBC
 107.2.1, CLARIFY.
 A) AS THERE IS NO NEW PIPING TO TUB AND SHOWER, DELETE
 REFERENCES TO CONNECT NEW SANITARY LINES TO EXISTING
 SANITARY LINES AND NOTE PIPING FOR TUB, SHOWER AND
 WATER CLOSET AS EXISTING.
 B) PROVIDE NOTE(S) ON THE PLANS STATING NO CHANGE IN
 CONFIGURATION OF TUB AND SHOWER. THE EXISTING TUB WILL
 BE REPLACED BY A NEW TUB OF THE SAME CONFIGURATION; THE
 SHOWER WALLS REMAIN AS IS AND THE EXISTING DRAIN SHALL
 BE USED.
  
 3. RESPONSE PROVIDED; NONE. 2ND REQUEST. A.1 REGARDING
 BAR SINK: NOTE AT CLOSET WHERE BAR SINK IS TO BE
 LOCATED INDICATES REBUILD A BAR. WAS THERE A BAR SINK
 IN THIS LOCATION BEFORE. ARE THE NECESSARY PLUMBING
 ROUGH-INS ALREADY IN PLACE? IF SO, INDICATE ON P.1 PLAN
 VIEW, SHOW EXISTING STACK (WASTE OR SOIL STACK WITH
 VENT STACK OR WASTE STACK VENT) AND WATER LOCATION(S).
 IF NOT, SHOW ON PLAN VIEW LOCATION AND TYPE OF EXISTING
 STACK(S), HOT/COLD WATER PLAN VIEW FOR NEW BAR SINK
 SHOWING SOURCE, VALVES, SIZES AND ROUTING. SEE P.1, BAR
 SINK SANITARY RISER DIAGRAM COMMENT 6A.
  
 4.RESPONSE PROVIDED; NONE. 2ND REQUEST. A.1 EXISTING
 KITCHEN TO BE REMODELED DOES NOT SHOW EXISTING
 CONFIGURATION. PER WPB FBC SHOW EXISTING CONFIGURATION
 OR, IF THIS IS A PROJECT TO BE EXECUTED AT A LATER
 DATE, THEN NOTE THAT IT IS NOT PART OF THE SCOPE.
  
 5. RESPONSE PROVIDED; NONE. 2ND REQUEST. A.1 EXISTING
 MASTER BATH DOES NOT SHOW A LAVATORY. PER WPB FBC
 107.2.1, SHOW THAT THERE IS AN EXISTING LAVATORY.
  
 6. RESPONSE PROVIDED; NO CHANGE IN CONFIGURATION OF
 SHOWER. P.1 CURB AND SHOWER BASE DETAILS. PER WPB FBC
 107.2.1, PLEASE CONSOLIDATE THE CURB, LINER AND SLOPE
 DETAIL AND THE WALL AND FLOOR DETAIL INTO ONE DETAIL
 FOR THE NEW SHOWER ONLY. PROVIDE ON THE DETAIL THE
 FOLLOWING INFORMATION:
 NEW COMMENT: PROVIDED DETAIL FOR WALL AND FLOOR SHALL
 INCLUDE THRESHOLD (CURB).
  
 7. RESPONSE PROVIDED; NO CHANGE IN CONFIGURATION OF TUB
 AND SHOWER P.1 WATER RISER DIAGRAMS. PER WPB FBC
 107.2.1, PROVIDE WATER RISER DIAGRAMS OF THE AFFECTED
 AREAS INCLUDING BUT NOT NECESSARILY LIMITED TO THE
 FOLLOWING:
 A) SECOND REQUEST: WATER RISER DIAGRAM FOR NEW BAR SINK
 SHOWING SOURCE, VALVES, SIZES AND ROUTING.
 B) PROVIDE IN-WALL PIPING FOR NEW SHOWER AND WALK-IN
 BATHTUB. NOT REQUIRED AS NO RECONFIGURATION.
 NEW COMMENT:
 A) FPC PL 412.3; PROVIDE NOTE INDIVIDUAL SHOWER AND
 TUB-SHOWER COMBINATION IN WALL VALVES SHALL BE
 BALANCED-PRESSURE, THERMOSTATIC OR COMBINATION
 BALANCED-PRESSURE/THERMOSTATIC VALVES THAT CONFORM TO
 THE REQUIREMENTS OF ASSE 1016/ASME A112.1016/CSA
 B125.16 OR ASME A112.18.1/CSA B125.1 AND SHALL BE
 INSTALLED AT THE POINT OF USE
 B) IS THE NEW BATHTUB TO BE PROVIDED WITH A DECK
 MOUNTED FAUCET AND CONTROLS. PER WPB FBC 107.2.1,
 CLARIFY. IF DECK MOUNTED PROVIDE A DETAIL SHOWING A
 WATER-TEMPERATURE LIMITING DEVICE THAT CONFORMS TO ASSE
 1070 INSTALLED TO LIMIT THE HOT WATER SUPPLIED TO THE
 TUB TO A MAXIMUM TEMPERATURE OF 120?F AS REQUIRED BY
 FPC PL 412.5. PROVIDE ACCESS TO THE SAME PER FBC PL
 606.3.
  
 8.P.1 SANITARY RISER DIAGRAMS
 A) RESPONSE PROVIDED; NONE. 2ND REQUEST. BAR SINK; PER
 FBC PL 901.2 PROVIDE VENT FOR FIXTURE TRAPS ACCORDANCE
 WITH ONE OF THE VENTING METHODS SPECIFIED IN THIS FBC
 PL CHAPTER 9. PLEASE NOTE, PER FBC PL 909.2, THE TOTAL
 FALL IN A FIXTURE DRAIN DUE TO PIPE SLOPE SHALL NOT
 EXCEED THE DIAMETER OF THE FIXTURE DRAIN, NOR SHALL THE
 VENT CONNECTION TO A FIXTURE DRAIN, EXCEPT FOR WATER
 CLOSETS, BE BELOW THE WEIR OF THE TRAP. THE VENTED
 FIXTURE DRAIN SHALL CONNECT TO HORIZONTAL FIXTURE
 BRANCH (FBC PL 710.1), A WASTE/SOIL STACK FBC PL 710.1
 OR A WASTE STACK VENT (FBC PL 913). THE VENT SHALL
 EXTEND AND CONNECT BY ONE OF THE METHODS LISTED IN FBC
 PL 905.1. IF AN AIR ADMITTANCE VALVE IS USED, IT SHALL
 COMPLY WITH FBC PL 918.3.1 SEE COMMENT 1 REGARDING
 INSTALLATION IN MULTISTORY BUILDINGS. TO BE CLEAR, AN
 AIR ADMITTANCE VALVE INSTALLED ON THE NINTH FLOOR WILL
 REQUIRE ADDITIONAL RELIEF VENT PIPING TO COMPLY.
 SEE COMMENT 3 REGARDING NOTING STACK LOCATION ON PLAN
 VIEW.
 B) RESPONSE PROVIDED; NONE. 2ND REQUEST. KITCHEN; SEE
 COMMENT 4. IF NOT INCLUDED IN THIS SCOPE, THEN PER WPB
 FBC 107.2.1, DELETE. REGARDING THE DRAWING; THE VENTED
 FIXTURE DRAIN SHALL CONNECT TO HORIZONTAL FIXTURE
 BRANCH (FBC PL 710.1), A WASTE/SOIL STACK FBC PL 710.1
 OR A WASTE STACK VENT (FBC PL 913). THE VENT SHALL
 EXTEND AND CONNECT BY ONE OF THE METHODS LISTED IN FBC
 PL 905.1. IF AN AIR ADMITTANCE VALVE IS USED, IT SHALL
 COMPLY WITH FBC PL 918.3.1. SEE COMMENT 1 REGARDING
 INSTALLATION IN MULTISTORY BUILDINGS. TO BE CLEAR, THE
 AIR ADMITTANCE VALVE AS SHOWN AT THE KITCHEN SINK
 SANITARY RISER DIAGRAM DOES NOT COMPLY.
  
 C)RESPONSE PROVIDED; NONE. 2ND REQUEST. DISHWASHER
 DRAIN TO CONNECT TO KITCHEN SINK TRAP INLET. SEE FBC
 RES P2706.2.
 D) MASTER BATHROOM; PLEASE NOTE THAT THE EXISTING CODE
 COMPLIANT INFRASTRUCTURE SHOULD ALREADY EXIST FOR THIS
 BATHROOM. NEW COMMENT: AS THERE IS NO CHANGE IN FIXTURE
 DRAIN INLET FLOOR PENETRATIONS FOR MASTER BATH TUB,
 SHOWER AND WATER CLOSET, THE SANITARY RISER DIAGRAM
 REGARDING THESE FIXTURES NEED TO BE NOTED EXISTING. THE
 SAME IS APPLICABLE TO THE LAVATORY.
 D1) RESPONSE PROVIDED; NONE. 2ND REQUEST. LAVATORY;
 PLEASE SEE COMMENT 5. PLEASE NOTE THAT THE EXISTING
 CODE COMPLIANT INFRASTRUCTURE SHOULD ALREADY EXIST FOR
 THIS BATHROOM. AS SUCH, YOU SHOULD BE ABLE TO NOTE
 CONNECT TO EXISTING PLUMBING CONNECTIONS. IF RELOCATED
 ON THE SAME WALL AND MINOR MODIFICATIONS ARE REQUIRED
 TO EXTEND OR SHORTEN PIPING, PROVIDE NOTE STATING THE
 SAME. COMPLY WITH FBC PL 909.1 FOR FIXTURE DRAIN. IF
 NOT, PLEASE SEE DRAWING COMMENTS BELOW.
 PER FBC PL 901.2 PROVIDE VENT FOR FIXTURE TRAPS
 ACCORDANCE WITH ONE OF THE VENTING METHODS SPECIFIED IN
 THIS FBC PL CHAPTER 9. PLEASE NOTE, PER FBC PL 909.2,
 THE TOTAL FALL IN A FIXTURE DRAIN DUE TO PIPE SLOPE
 SHALL NOT EXCEED THE DIAMETER OF THE FIXTURE DRAIN, NOR
 SHALL THE VENT CONNECTION TO A FIXTURE DRAIN, EXCEPT
 FOR WATER CLOSETS, BE BELOW THE WEIR OF THE TRAP. THE
 VENTED FIXTURE DRAIN SHALL CONNECT TO HORIZONTAL
 FIXTURE BRANCH (FBC PL 710.1), A WASTE/SOIL STACK FBC
 PL 710.1 OR A WASTE STACK VENT (FBC PL 913). THE VENT
 SHALL EXTEND AND CONNECT BY ONE OF THE METHODS LISTED
 IN FBC PL 905.1. IF AN AIR ADMITTANCE VALVE IS USED, IT
 SHALL COMPLY WITH FBC PL 918.3.1 SEE COMMENT 1
 REGARDING INSTALLATION IN MULTISTORY BUILDINGS. . TO BE
 CLEAR, AN AIR ADMITTANCE VALVE INSTALLED ON THE NINTH
 FLOOR WILL REQUIRE ADDITIONAL RELIEF VENT PIPING TO
 COMPLY.
  
 9. RESPONSE PROVIDED; NONE. 2ND REQUEST. P.1 GENERAL
 PLUMBING NOTE 1; PER WPB FBC 107.2.1, CORRECT TO READ
 (PLUMBING 2020 7TH EDITION)
  
  
 END OF COMMENTS.
 A COMPREHENSIVE REVIEW COULD NOT BE ACCOMPLISHED AT
 THIS TIME. PLEASE RESUBMIT CLEARLY LEGIBLE PLANS AND A
 RESPONSE NARRATIVE ADDRESSING THE GAS/PLUMBING COMMENTS
 FROM THE PRIOR REVIEW.
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID
 THE PREVIOUSLY REVIEWED SHEETS. ALL PLANS TO BE SIGNED
 AND SEALED BY THE DESIGNER AS REQUIRED BY FAC AND FS.
  
  
  
 JERALD SMITH
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
 EMAIL [email protected]
 MOBILE 561-246-0882
 PLEASE NOTE THAT I TYPICALLY WORK ON TUESDAYS AND
 THURSDAYS
  
 21030412 2427 PRESIDENTIAL WAY # 904
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2021-04-01 Cont ID  
Sent By jesmith Date 2021-04-01 Time 16:26 Rev Time 0.00
Received By jesmith Date 2021-03-30 Time 15:03 Sent To  
Notes
2021-04-01 16:23:31CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2020 7TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1
 WPB CCCM=WEST PALM BEACH CROSS-CONNECTION CONTROL
 MANUAL REVISED 2017
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020
 7TH EDITION
 FBC RES = FLORIDA RESIDENTIAL CODE 2020 7TH EDITION
 FBC EX = FLORIDA EXISTING BUILDING CODE 2020 7TH
 EDITION
 FBC PL = FLORIDA PLUMBING CODE 2020 7TH EDITION
 FAC= FLORIDA ADMINISTRATIVE CODE
 FS = FLORIDA STATUTES
  
 21030412 2427 PRESIDENTIAL WAY # 904
  
 1ST REVIEW
 PLUMBING COMMENTS: DENIED
  
 1.BUILDING HAS TWENTY FOUR FLOORS (BRANCH INTERVALS);
 UNIT IS ON THE NINTH FLOOR (BRANCH INTERVAL). PER FBC
 PL 918.3.1, INDIVIDUAL AND BRANCH-TYPE AIR ADMITTANCE
 VALVES SHALL VENT ONLY FIXTURES THAT ARE ON THE SAME
 FLOOR LEVEL AND CONNECT TO A HORIZONTAL BRANCH DRAIN.
 WHERE THE HORIZONTAL BRANCH IS LOCATED MORE THAN FOUR
 BRANCH INTERVALS FROM THE TOP OF THE STACK, THE
 HORIZONTAL BRANCH SHALL BE PROVIDED WITH A RELIEF VENT
 THAT SHALL CONNECT TO A VENT STACK OR STACK VENT, OR
 EXTEND OUTDOORS TO THE OPEN AIR. THE RELIEF VENT SHALL
 CONNECT TO THE HORIZONTAL BRANCH DRAIN BETWEEN THE
 STACK AND THE MOST DOWNSTREAM FIXTURE DRAIN CONNECTED
 TO THE HORIZONTAL BRANCH DRAIN. THE RELIEF VENT SHALL
 BE SIZED IN ACCORDANCE WITH SECTION 906.2 AND INSTALLED
 IN ACCORDANCE WITH SECTION 905. THE RELIEF VENT SHALL
 BE PERMITTED TO SERVE AS THE VENT FOR OTHER FIXTURES.
  
 2.P.1 SANITARY ISOMETRIC INDICATES EXTENSION OF
 HORIZONTAL FIXTURE DRAIN PIPING TO NEW THROUGH THE SLAB
 LOCATIONS FOR THE NEW WALK-IN BATHTUB AND SHOWER. PER
 WPB FBC 107.2.1, PROVIDE DETAIL FOR NEW THROUGH THE
 FLOOR PENETRATIONS SHOWING COMPLIANCE WITH FBC CHAPTER
 7 REGARDING FIRESTOP OF PENETRATIONS.
  
 3. A.1 REGARDING BAR SINK: NOTE AT CLOSET WHERE BAR
 SINK IS TO BE LOCATED INDICATES REBUILD A BAR. WAS
 THERE A BAR SINK IN THIS LOCATION BEFORE. ARE THE
 NECESSARY PLUMBING ROUGH-INS ALREADY IN PLACE? IF SO
 INDICATE ON P.1 PLAN VIEW, SHOW EXISTING STACK (WASTE
 OR SOIL STACK WITH VENT STACK OR WASTE STACK VENT) AND
 WATER LOCATION(S). IF NOT, SHOW ON PLAN VIEW LOCATION
 AND TYPE OF EXISTING STACK(S), HOT/COLD WATER PLAN VIEW
 FOR NEW BAR SINK SHOWING SOURCE, VALVES, SIZES AND
 ROUTING. SEE P.1, BAR SINK SANITARY RISER DIAGRAM
 COMMENTS.
  
 4.A.1 EXISTING KITCHEN TO BE REMODELED DOES NOT SHOW
 EXISTING CONFIGURATION. PER WPB FBC SHOW EXISTING
 CONFIGURATION OR, IF THIS IS A PROJECT TO BE EXECUTED
 AT A LATER DATE, THEN NOTE THAT IT IS NOT PART OF THE
 SCOPE.
  
 5.A.1 EXISTING MASTER BATH DOES NOT SHOW A LAVATORY.
 PER WPB FBC 107.2.1, SHOW THAT THERE IS AN EXISTING
 LAVATORY.
  
 6.P.1 CURB AND SHOWER BASE DETAILS. PER WPB FBC
 107.2.1, PLEASE CONSOLIDATE THE CURB, LINER AND SLOPE
 DETAIL AND THE WALL AND FLOOR DETAIL INTO ONE DETAIL
 FOR THE NEW SHOWER ONLY. PROVIDE ON THE DETAIL THE
 FOLLOWING INFORMATION:
 A )REGARDING THE CURB, LINER AND SLOPE DETAIL, INDICATE
 WHICH APPLIES TO THE NEW SHOWER AND DELETE THE
 NON-APPLICABLE. IF NO CURB (REFERRED TO AS A THRESHOLD
 IN FBC PL 421.5.2) HOW, WILL THE WATER BE RETAINED IN
 THE SHOWER COMPARTMENT WITHOUT SHOWER DOORS. 107.2.1.2.
 ADDITIONAL INFORMATION IS REQUIRED. IT IS NOTED THAT A
 CURB (THRESHOLD) TOP LEVEL WITH A RAISED FLOOR IS
 INDICATED ON ONE DETAIL, AND SHOWER FLOOR LINER IS
 SLOPED FROM THAT POINT TO THE DRAIN. PLEASE NOTE THAT
 THE MINIMUM SLOPE OF THE LINER TO THE DRAIN SHALL BE ?
 INCH PER FOOT (2% SLOPE).
 B)INDICATE THE HEIGHT OF THE CERAMIC WALL TILE ABOVE
 THE DRAIN INLET.
 C)SLOPE (NOTED ON WALL AND FLOOR DETAIL
 D)LINER MATERIAL (NOTED ON WALL AND FLOOR DETAIL
 E)SHOWER DRAIN MATERIAL AND TYPE (IE. PVC/C.I.WITH
 CLAMPING RING )
  
 7. P.1 WATER RISER DIAGRAMS. PER WPB FBC 107.2.1,
 PROVIDE WATER RISER DIAGRAMS OF THE AFFECTED AREAS
 INCLUDING BUT NOT NECESSARILY LIMITED TO THE FOLLOWING:
 A) WATER RISER DIAGRAM FOR NEW BAR SINK SHOWING SOURCE,
 VALVES, SIZES AND ROUTING.
 B) PROVIDE IN-WALL PIPING FOR NEW SHOWER AND WALK-IN
 BATHTUB.
  
 8.P.1 SANITARY RISER DIAGRAMS
 A)BAR SINK; PER FBC PL 901.2 PROVIDE VENT FOR FIXTURE
 TRAPS ACCORDANCE WITH ONE OF THE VENTING METHODS
 SPECIFIED IN THIS FBC PL CHAPTER 9. PLEASE NOTE, PER
 FBC PL 909.2, THE TOTAL FALL IN A FIXTURE DRAIN DUE TO
 PIPE SLOPE SHALL NOT EXCEED THE DIAMETER OF THE FIXTURE
 DRAIN, NOR SHALL THE VENT CONNECTION TO A FIXTURE
 DRAIN, EXCEPT FOR WATER CLOSETS, BE BELOW THE WEIR OF
 THE TRAP. THE VENTED FIXTURE DRAIN SHALL CONNECT TO
 HORIZONTAL FIXTURE BRANCH (FBC PL 710.1), A WASTE/SOIL
 STACK FBC PL 710.1 OR A WASTE STACK VENT (FBC PL 913).
 THE VENT SHALL EXTEND AND CONNECT BY ONE OF THE METHODS
 LISTED IN FBC PL 905.1. IF AN AIR ADMITTANCE VALVE IS
 USED, IT SHALL COMPLY WITH FBC PL 918.3.1. SEE COMMENT
 1. SEE COMMENT 3 REGARDING NOTING STACK LOCATION ON
 PLAN VIEW.
 B)KITCHEN; SEE COMMENT 4. IF NOT INCLUDED IN THIS
 SCOPE, THEN PER WPB FBC 107.2.1, DELETE. REGARDING THE
 DRAWING; THE VENTED FIXTURE DRAIN SHALL CONNECT TO
 HORIZONTAL FIXTURE BRANCH (FBC PL 710.1), A WASTE/SOIL
 STACK FBC PL 710.1 OR A WASTE STACK VENT (FBC PL 913).
 THE VENT SHALL EXTEND AND CONNECT BY ONE OF THE METHODS
 LISTED IN FBC PL 905.1. IF AN AIR ADMITTANCE VALVE IS
 USED, IT SHALL COMPLY WITH FBC PL 918.3.1. SEE COMMENT
 1.
 DISHWASHER DRAIN TO CONNECT TO KITCHEN SINK TRAP. SEE
 FBC RES P2706.2.
 C) MASTER BATHROOM; PLEASE NOTE THAT THE EXISTING CODE
 COMPLIANT INFRASTRUCTURE SHOULD ALREADY EXIST FOR THIS
 BATHROOM.
 C1) LAVATORY; PLEASE SEE COMMENT 5. PLEASE NOTE THAT
 THE EXISTING CODE COMPLIANT INFRASTRUCTURE SHOULD
 ALREADY EXIST FOR THIS BATHROOM. AS SUCH, YOU SHOULD BE
 ABLE TO NOTE CONNECT TO EXISTING PLUMBING CONNECTIONS.
 IF RELOCATED ON THE SAME WALL AND MINOR MODIFICATIONS
 ARE REQUIRED TO EXTEND OR SHORTEN PIPING, PROVIDE NOTE
 STATING THE SAME. COMPLY WITH FBC PL 909.1 FOR FIXTURE
 DRAIN. IF NOT, PLEASE SEE DRAWING COMMENTS BELOW.
 PER FBC PL 901.2 PROVIDE VENT FOR FIXTURE TRAPS
 ACCORDANCE WITH ONE OF THE VENTING METHODS SPECIFIED IN
 THIS FBC PL CHAPTER 9. PLEASE NOTE, PER FBC PL 909.2,
 THE TOTAL FALL IN A FIXTURE DRAIN DUE TO PIPE SLOPE
 SHALL NOT EXCEED THE DIAMETER OF THE FIXTURE DRAIN, NOR
 SHALL THE VENT CONNECTION TO A FIXTURE DRAIN, EXCEPT
 FOR WATER CLOSETS, BE BELOW THE WEIR OF THE TRAP. THE
 VENTED FIXTURE DRAIN SHALL CONNECT TO HORIZONTAL
 FIXTURE BRANCH (FBC PL 710.1), A WASTE/SOIL STACK FBC
 PL 710.1 OR A WASTE STACK VENT (FBC PL 913). THE VENT
 SHALL EXTEND AND CONNECT BY ONE OF THE METHODS LISTED
 IN FBC PL 905.1. IF AN AIR ADMITTANCE VALVE IS USED, IT
 SHALL COMPLY WITH FBC PL 918.3.1. SEE COMMENT 1.
 C2) BATHTUB; PLEASE NOTE THAT THE EXISTING CODE
 COMPLIANT INFRASTRUCTURE SHOULD ALREADY EXIST FOR THIS
 BATHROOM. AS SUCH, YOU SHOULD BE ABLE TO NOTE CONNECT
 TO EXISTING PLUMBING CONNECTIONS TO EXTEND OR SHORTEN
 FIXTURE DRAINS. COMPLY WITH FBC PL 909.1. IF NOT,
 PLEASE SEE DRAWING COMMENTS BELOW.
 COMPLY WITH FBC PL 909.1 VENTING OF FIXTURE TRAP,
 DISTANCE FROM TRAP TO VENT AND FBC PL 913.1 HORIZONTAL
 WET VENTING.
 C3) SHOWER; PLEASE NOTE THAT THE EXISTING CODE
 COMPLIANT INFRASTRUCTURE SHOULD ALREADY EXIST FOR THIS
 BATHROOM. AS SUCH, YOU SHOULD BE ABLE TO NOTE CONNECT
 TO EXISTING PLUMBING CONNECTIONS TO EXTEND OR SHORTEN
 FIXTURE DRAINS. COMPLY WITH FBC PL 909.1. IF NOT,
 PLEASE SEE DRAWING COMMENTS BELOW.
 COMPLY WITH FBC PL 909.1 VENTING OF FIXTURE TRAP,
 DISTANCE FROM TRAP TO VENT AND FBC PL 913.1 HORIZONTAL
 WET VENTING.
 C4) WATER CLOSET; PLEASE NOTE THAT THE EXISTING CODE
 COMPLIANT INFRASTRUCTURE SHOULD ALREADY EXIST FOR THIS
 BATHROOM. AS SUCH, YOU SHOULD BE ABLE TO NOTE CONNECT
 TO EXISTING PLUMBING CONNECTIONS TO EXTEND OR SHORTEN
 FIXTURE DRAINS. COMPLY WITH FBC PL 909.1. IF NOT,
 PLEASE SEE DRAWING COMMENTS BELOW.
 C5)COMPLY WITH FBC PL 909.1 VENTING OF FIXTURE TRAP,
 DISTANCE FROM TRAP TO VENT AND FBC PL 913.1 HORIZONTAL
 WET VENTING.
  
 9.P.1 REGARDING NOTE THAT ALL THE EXISTING ROUGH-IN
 PLUMBING IS IN PLACE; PLEASE NOTE:
 A) THE REPLACEMENT OF THE EXISTING BATHTUB, WHICH
 APPEARS TO BE A ROMAN STYLE BATHTUB AND PROBABLY HAS A
 DECK FAUCET, WILL REQUIRE WALL PIPING MODIFICATIONS AND
 PER FBC PL 412.3, A BALANCED-PRESSURE, THERMOSTATIC OR
 COMBINATION BALANCED-PRESSURE/THERMOSTATIC VALVE THAT
 CONFORMS TO THE REQUIREMENTS OF ASSE 1016/ASME
 A112.1016/CSA B125.16 OR ASME A112.18.1/CSA B125.1
 INSTALLED AT THE POINT OF USE.
 B) THE REPLACEMENT OF THE EXISTING SHOWER WITH THE
 WALK-IN BATHTUB WILL ALSO REQUIRE WALL MODIFICATIONS
 AND SHALL PER FBC PL 412.5, PROVIDE HOT WATER SUPPLIED
 TO BATHTUBS AND WHIRLPOOL BATHTUBS BE LIMITED TO A
 MAXIMUM TEMPERATURE OF 120?F (49?C) BY A
 WATER-TEMPERATURE LIMITING DEVICE THAT CONFORMS TO ASSE
 1070 OR CSA B125.3, EXCEPT WHERE SUCH PROTECTION IS
 OTHERWISE PROVIDED BY A COMBINATION TUB/SHOWER VALVE IN
 ACCORDANCE WITH SECTION 412.3. 412.5
  
 10.P.1 REGARDING NOTE THAT WALK-IN BATHTUB IS TO BE
 INSTALLED BY MANUFACTURER; PLEASE NOTE THAT PER THE
 REQUIREMENTS OF WPB FBC SECTION 105, THE PLUMBING
 CONTRACTOR IS RESPONSIBLE FOR THE WALK-IN BATHTUB,
 UNLESS MANUFACTURER IS A PLUMBING CONTRACTOR AS WELL,
 IN WHICH CASE THAT ENTITY SHALL PULL A SEPARATE
 PLUMBING PERMIT FOR THE TUB INSTALLATION.
  
 11.PER WPB FBC 107.2.1, SUBMIT THE MANUFACTURER'S
 SPECIFICATION/INSTALLATION MANUAL FOR THE WALK-IN
 BATHTUB.
  
 12.P.1 GENERAL PLUMBING NOTE 1; PER WPB FBC 107.2.1,
 CORRECT TO READ (PLUMBING 2020 7TH EDITION)
  
  
 END OF COMMENTS.
 A COMPREHENSIVE REVIEW COULD NOT BE ACCOMPLISHED AT
 THIS TIME. PLEASE RESUBMIT CLEARLY LEGIBLE PLANS AND A
 RESPONSE NARRATIVE ADDRESSING THE GAS/PLUMBING COMMENTS
 FROM THE PRIOR REVIEW.
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID
 THE PREVIOUSLY REVIEWED SHEETS.ALL PLANS TO BE SIGNED
 AND SEALED BY THE DESIGNER AS REQUIRED BY FAC AND FS.
  
  
  
 JERALD SMITH
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
 EMAIL [email protected]
 MOBILE 561-246-0882
 PLEASE NOTE THAT I TYPICALLY WORK ON TUESDAYS AND
 THURSDAYS

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2021-06-22 Cont ID  
Sent By medwards Date 2021-06-17 Time 16:51 Rev Time 0.00
Received By lcrespo Date 2021-06-17 Time 16:51 Sent To  
Notes
2021-06-22 13:51:40WILL DROP OFF ORIGINAL.
2021-06-17 16:56:26PAPER DOCUMENTS SUBMITTED HAD A COPY OF A DIGITAL
 SIGNATURE, WE CANNOT ACCEPT A COPY OF A DIGITAL
 SIGNATURE. PLEASE SUBMIT THE ORIGINAL DIGITALLY SIGNED
 DRAWING OR YOU CAN BRING AN ORIGINAL SIGNED AND SEALED
 PAPER DRAWING TO OUR OFFICE.
  
 PER THE WPB AMENDMENTS TO THE FBC, EACH SHEET OF PLAN
 (INCLUDING THE SUPPORTING DOCUMENTS) IS REQUIRED TO BE
 SIGNED AND SEALED BY THE PERSON RESPONSIBLE FOR THE
 DESIGN. A DIGITAL PLAN REQUIRES A DIGITAL SIGNATURE
 WITH THE PROPER THIRD PARTY VERIFICATION. PROVIDE
 CORRECTION. ALTERNATIVELY, A SIGNED/SEALED PAPER SET
 MAY BE SUPPLIED TO THE BUILDING DEPARTMENT WHEN ALL
 TRADES ARE APPROVED. WPB FBC 107.1; FS 471/481
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2021-03-12 Cont ID  
Sent By medwards Date 2021-03-12 Time 13:15 Rev Time 0.00
Received By medwards Date 2021-03-12 Time 13:12 Sent To  
Notes
2021-03-12 13:16:29ORIGINAL SIGNED AND SEALED PAPER DRAWINGS ROUTED TO
 STORAGE.ME