| Plan Review Stops For Permit 21030214 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2021-05-24 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2021-05-24 |
Time |
15:07 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2021-05-24 |
Time |
15:06 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2021-04-29 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2021-04-29 |
Time |
13:23 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2021-04-29 |
Time |
13:10 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2021-03-11 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2021-03-11 |
Time |
16:22 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2021-03-11 |
Time |
16:22 |
Sent To |
|
|
| Notes |
| 2021-03-11 15:51:35 | PLAN | | | REVIEW COMMENTS | | | | | | 1ST REVIEW: FBC SEVENTH EDITION (2020) | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY BUILDING | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) THE WIND DESIGN DATA REFERENCES THE 2017 FBC | | | RESIDENTIAL AND ASCE 7 - 10. BASED ON THE PERMIT | | | APPLICATION DATE OF 3/4/2021, THIS PROJECT IS UNDER THE | | | 2020 FBC BUILDING SEVENTH EDITION AND ASCE 7-16 . THE | | | FBC BUILDING APPLIES AND NOT THE FBC RESIDENTIAL. THE | | | PLANS HAVE SEVERAL REFERENCES TO THE FBC SIXTH EDITION | | | (2017). THE FBC SEVENTH EDITION (2020) WENT INTO EFFECT | | | ON DECEMBER 31, 2020. ALL NEW PERMITS APPLIED FOR ON OR | | | AFTER THAT DATE ARE REQUIRED TO COMPLY WITH AND | | | REFERENCE THE 2020 FBC SEVENTH EDITION. FS CHAPTER 553 | | | | | | 2) THE GENERATOR PAD IS SPECIFIED AS 4" THICK CONCRETE. | | | BASED ON THE GENERATOR SPECIFICATIONS IT WEIGHS OVER | | | 4,000 LBS. WITH THE ACOUSTIC ENCLOSURE. OTHER | | | GENERATORS OF SIMILAR SIZE HAVE 6" OR 8" THICK SLABS. | | | SUBMIT CALCULATIONS TO SHOW THAT A 4" SLAB IS ADEQUATE. | | | FBC AMENDMENTS 107.2.1.2 | | | | | | 3) THE GENERATOR IS LOCATED IN A SPECIAL FLOOD HAZARD | | | AREA, ZONE "AE" WITH A BASE FLOOD ELEVATION OF 12.2' | | | NAVD 88. THE CITY HAS A REQUIRED FREEBOARD OF 2 FEET | | | MORE. THIS MAKES THE REQUIRED ELEVATION 14.2' NAVD. THE | | | GENERATOR WILL NEED TO BE ELEVATED ABOVE 14.2' NAVD OR | | | BE DRY FLOOD PROOFED. SHOW HOW THIS WILL BE | | | ACCOMPLISHED. A PRE-CONSTRUCTION ELEVATION CERTIFICATE | | | WILL BE REQUIRED BEFORE THE PERMIT IS ISSUED. A FINAL | | | ELEVATION CERTIFICATE WILL BE REQUIRED AT THE FINAL | | | INSPECTION. FBC 1612 | | | | | | 4) SUBMIT A SITE PLAN WITH THE ELEVATIONS DEFINED IN | | | NAVD 88. FBC 107.2.1 | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2021-04-28 |
|
|
Cont ID |
|
| Sent By |
equinone |
Date |
2021-04-28 |
Time |
14:32 |
Rev Time |
0.00 |
| Received By |
equinone |
Date |
2021-04-28 |
Time |
14:32 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2021-03-17 |
|
|
Cont ID |
|
| Sent By |
equinone |
Date |
2021-03-17 |
Time |
10:54 |
Rev Time |
0.00 |
| Received By |
equinone |
Date |
2021-03-17 |
Time |
10:54 |
Sent To |
|
|
| Notes |
| 2021-03-17 10:54:49 | CODES IN EFFECT | | | | | | CODES IN EFFECT: | | | | | | FBC = FLORIDA BUILDING CODE 2020 7TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2020 | | | 7TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 | | | 7TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2020 | | | 7TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2020 7TH EDITION | | | NEC = NFPA 70 2017 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | FAC = FLORIDA ADMINISTRATIVE CODE | | | | | | REVIEW STATUS: FAILED. PLEASE SEE COMMENTS BELOW: | | | | | | 1) PLEASE PROVIDE CUT SHEETS (SPECS) FOR AUTOMATIC | | | TRASNFER SWITCH (ATS). FBC 107 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | IF THE RESUBMITTAL IS NOT PREPARED BY A DESIGN | | | PROFESSIONAL (ARCHITECT OR ENGINEER), AND THE PAGES ARE | | | 11X17 OR SMALLER, YOU MAY RESUBMIT, ALONG WITH A | | | COMPLETED RESUBMITTAL FORM, VIA EMAIL TO | | | [email protected]. THE EMAIL SHOULD INCLUDE THE PERMIT | | | NUMBER AND "RESUBMITTAL" IN THE SUBJECT LINE. THE | | | RESUBMITTAL FORM CAN BE FOUND AT THIS WEBSITE: | | | | | | HTTPS://WWW.WPB.ORG/GOVERNMENT/DEVELOPMENT-SERVICES/FOR | | | MS | | | | | | ENRIQUE QUINONEZ P.E. | | | ELECTRICAL PLANS EXAMINER | | | DEVELOPMENT SERVICES | | | CITY OF WEST PAM BEACH | | | 401 CLEMATIS STREET, 1ST FLOOR | | | WEST PALM BEACH, FL 33401 | | | | | | FEEL FREE TO CONTACT ME IF YOU WISH TO DISCUSS, | | | 561-805-6746. | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2021-03-09 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2021-03-09 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2021-03-09 |
Time |
12:52 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
3 |
Status |
P |
Date |
2021-06-25 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2021-06-25 |
Time |
11:20 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2021-06-25 |
Time |
11:20 |
Sent To |
|
|
| Notes |
| 2021-06-25 11:20:48 | 06/25/20 REVIEWED FOR CODE COMPLIANCE (LP GAS) | | | | | | BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE | | | COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN | | | PROFESSIONAL, CONTRACTORS, OR THEIR REPRESENTATIVES | | | FROM THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL, | | | STATE, AND NATIONAL CODES AND STANDARDS IN EFFECT AT | | | THE TIME OF PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK | | | OF EVERY ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM | | | REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES | | | / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO | | | AVOID VOIDING OF THE PERMIT. | | | | | | LUIS A. CRESPO | | | PLUMBING PLAN EXAMINER / INSPECTOR | | | EMAIL: [email protected] OFFICE: 561 805-6720 | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
F |
Date |
2021-06-12 |
|
|
Cont ID |
|
| Sent By |
abelisle |
Date |
2021-06-12 |
Time |
13:02 |
Rev Time |
0.00 |
| Received By |
abelisle |
Date |
2021-06-12 |
Time |
10:38 |
Sent To |
|
|
| Notes |
| 2021-06-12 13:15:13 | 2ND REVIEW FBC-2020 PLUMBING | | | PERMIT-21030214 | | | 6/12/2021 | | | | | | CODES IN EFFECT: | | | | | | FBC P- FLORIDA PLUMBING CODE SEVENTH EDITION 2020 | | | FBC ACC- FLORIDA ACCESSIBILITY CODE SEVENTH EDITION | | | 2020 | | | FBC FG- FLORIDA FUEL GAS CODE SEVENTH EDITION 2020 | | | FBC B- FLORIDA BUILDING CODE SEVENTH EDITION 2020 | | | FBC M- FLORIDA MECHANICAL CODE SEVENTH EDITION 2020 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SEVENTH | | | EDITION 2020 FBC EX- FLORIDA EXISTING BUILDING CODE | | | SEVENTH EDITION 2020 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SEVENTH | | | EDITION 2020 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1- 2ND REQUEST: 4) A CATHODIC PROTECTION SYSTEM SHALL | | | BE REQUIRED PER NFPA 58 SECS. 5.2.1.11, 6.6.6.1 (I) AND | | | SHALL BE MONITORED PER NFPA 58 SEC.6.6.6.1 (J). SUBMIT | | | DETAILS ON THE TYPE OF CATHODIC PROTECTION, SIZE (LBS) | | | & NUMBER OF MAGNESIUM BAG(S), SIZE & TYPE OF ANODE | | | CABLE. NFPA 58 SEC. 6.17.3. | | | 2- DOCCUMENT SUBMITTED FROM TIE DOWN MANUFACTURING | | | SHALL BE STAMPED BY THE ENGINEER | | | 3- PERMIT APPLICATION STATES DUAL FUEL NATURAL GAS AND | | | PROPANE. GENERATOR MANUFACTURE ONLY STATES NATURAL GAS- | | | PLEASE CLARIFY HOW NATURAL GAS AND PROPANE WILL BE | | | INTERCONNECTED TO THE GENERATOR. | | | 4- INDICATE THE DELIVERY PRESSURE (PSI) OF THE SYSTEM | | | ON THE PLAN PER 2020 FBC FUEL GAS SEC. 402.2 OR 2020 | | | FBC FUEL GAS RES. SEC. G2413.2. | | | 5- SUBMIT A COPY OF THE SIZING TABLE USED IN THE DESIGN | | | FOR THE GAS SYSTEM OR PLACE A NOTE ON BOTH SETS OF | | | PLANS LISTING THE SIZING TABLES FROM GAS CODES OR | | | ANOTHER STANDARD THAT WERE USED IN THE DESIGN OF THIS | | | SYSTEM 2020 FBC FUEL GAS SEC. 402.3 OR 2020 FBC FUEL | | | GAS RES. SEC. G2413.3 | | | 6- SUBMIT GENERATOR MANUFACTURES FULL INSTALLATION | | | MANUAL AND SPECIFICATIONS . FGC SEC.305.1, FBC-RES. | | | SEC.G2408.1. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | ATELYO BELISLE | | | PLUMBING INSPECTOR / | | | PLUMBING PLAN REVIEW | | | AVAILABLE FROM 1:00 PM TO 4:00 PM | | | [email protected] | | | 561-805-6695 | | | | | | | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2021-05-25 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2021-05-25 |
Time |
14:09 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2021-05-25 |
Time |
12:58 |
Sent To |
|
|
| Notes |
| 2021-05-25 13:02:27 | 1) SUBMIT SPECIFICATIONS FOR THE LP TANK.THE TANK SHALL | | | BE ANCHORED IN ACCORDANCE WITH NFPA 58 SEC. 6.6.1.6.. | | | 2) SUBMIT MANUFACTURER?S SPECIFICATIONS AND | | | INSTALLATION INSTRUCTIONS FOR THE PRESSURE REGULATORS. | | | REGULATORS INSTALLED ON THE EXTERIOR OF THE BUILDING | | | SHALL BE APPROVED FOR OUTDOOR INSTALLATION. IDENTIFY ON | | | THE SPECIFICATION SHEETS WHICH MODEL REGULATOR IS BEING | | | INSTALLED AND THE ORIFICE SIZE TO ENSURE THE REGULATOR | | | CAN ACCOMMODATE THE BTU LOAD THROUGH THE REGULATOR. FGC | | | SEC.410.1. | | | 3) PROVIDE THE SIZE OF THE HOLD-DOWN CABLES/STRAPS FOR | | | THE TANK AND THE TYPE AND LENGTH OF GROUND ANCHORS TO | | | BE INSTALLED TO PREVENT FLOTATION. NFPA 58 SEC. | | | 6.6.1.6. | | | 4) A CATHODIC PROTECTION SYSTEM SHALL BE REQUIRED PER | | | NFPA 58 SECS. 5.2.1.11, 6.6.6.1 (I) AND SHALL BE | | | MONITORED PER NFPA 58 SEC.6.6.6.1 (J). SUBMIT DETAILS | | | ON THE TYPE OF CATHODIC PROTECTION, SIZE (LBS) & NUMBER | | | OF MAGNESIUM BAG(S), SIZE & TYPE OF ANODE CABLE. NFPA | | | 58 SEC. 6.17.3. | | | 5) A UNION IS REQUIRED WITHIN ON FOOT OF EITHER SIDE OF | | | THE MP REGULATOR. FBC-FUEL GAS SEC.410.2 (7). | | | | | | TIM LARGE | | | CHIEF PLUMBING INSPECTOR | | | PLUMBING PLAN REVIEW | | | 561-805-6692 | | | [email protected] | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2021-06-25 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2021-06-25 |
Time |
11:20 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2021-06-18 |
Time |
09:51 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2021-06-12 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2021-06-12 |
Time |
15:41 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2021-05-27 |
Time |
09:31 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2021-05-25 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2021-05-25 |
Time |
15:07 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2021-05-07 |
Time |
14:03 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2021-04-29 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2021-04-29 |
Time |
13:27 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2021-04-20 |
Time |
09:56 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2021-03-24 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-03-24 |
Time |
11:09 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-03-05 |
Time |
11:19 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2021-03-24 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-03-24 |
Time |
11:09 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-03-24 |
Time |
10:56 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
N |
Date |
2021-06-25 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2021-06-25 |
Time |
11:21 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2021-06-25 |
Time |
11:21 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
N |
Date |
2021-06-12 |
|
|
Cont ID |
|
| Sent By |
abelisle |
Date |
2021-06-12 |
Time |
10:38 |
Rev Time |
0.00 |
| Received By |
abelisle |
Date |
2021-06-12 |
Time |
10:38 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
N |
Date |
2021-05-25 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2021-05-25 |
Time |
12:57 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2021-05-25 |
Time |
08:42 |
Sent To |
|
|
| Notes |
| 2021-05-25 12:58:20 | THIS IS A GAS PERMIT. NO PLUMBING BEING INSTALLED. |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
4 |
Status |
P |
Date |
2021-06-25 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2021-06-25 |
Time |
11:55 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2021-06-25 |
Time |
11:55 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
P |
Date |
2021-05-24 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2021-05-24 |
Time |
15:07 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2021-05-24 |
Time |
15:07 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
F |
Date |
2021-04-29 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2021-04-29 |
Time |
13:23 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2021-04-29 |
Time |
13:23 |
Sent To |
|
|
| Notes |
| 2021-04-29 13:27:33 | THE DIGITAL SIGNATURE ON THE REVISED GENERATOR PAD | | | DRAWING ON SHEET E-5 CAN NOT BE VERIFIED. | | | ELECTRONICALLY SUBMITTED DRAWINGS ARE REQUIRED TO HAVE | | | THE ARCHITECT OR ENGINEER'S DIGITAL SIGNATURE ON THEM. | | | YOU ALSO HAVE THE OPTION TO SUBMIT THE SIGNED AND | | | SEALED PAPER VERSION OF DRAWINGS. AFTER THE ELECTRONIC | | | PLANS HAVE BEEN APPROVED, YOU CAN SUBMIT THE | | | CORRESPONDING PAPER DRAWINGS AT THE BUILDING DEPARTMENT | | | TO BE VERIFIED. THE ARCHITECT OR ENGINEER'S ORIGINAL | | | HANDWRITTEN SIGNATURE AND SEAL IS REQUIRED TO BE ON THE | | | DRAWINGS. NO PHOTOCOPY OR OTHER FACSIMILES OF THE | | | SIGNATURE ARE ACCEPTABLE. FS 487 & 61G1 OR FS 471 & | | | 61G15 |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2021-03-11 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2021-03-11 |
Time |
16:22 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2021-03-11 |
Time |
16:22 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2021-03-23 |
|
|
Cont ID |
|
| Sent By |
awooten |
Date |
2021-03-23 |
Time |
|
Rev Time |
|
| Received By |
awooten |
Date |
2021-03-23 |
Time |
|
Sent To |
|
|
| Notes |
|
|