Plan Review Details - Permit 21030155
Plan Review Stops For Permit 21030155
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2021-05-07 Cont ID  
Sent By rmcphers Date 2021-05-07 Time 07:37 Rev Time 0.00
Received By rmcphers Date 2021-05-07 Time 07:37 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2021-04-30 Cont ID  
Sent By rmcphers Date 2021-04-30 Time 13:50 Rev Time 0.00
Received By rmcphers Date 2021-04-30 Time 13:47 Sent To  
Notes
2021-04-30 13:50:16FLAG POLE
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected].
 CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1
 AMENDMENT
  
 CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107
 1) DRAWINGS SHOW A 25' FLAG POLE - THE PERMIT
 APPLICATION STATES A 35' FLAG POLE - THEY NEED TO
 MATCH.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2021-03-26 Cont ID  
Sent By rmcphers Date 2021-03-26 Time 11:26 Rev Time 0.00
Received By rmcphers Date 2021-03-26 Time 11:19 Sent To  
Notes
2021-03-26 11:26:39FLAG POLE
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected]
 CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1
 AMENDMENTS
  
 CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107
 1) PLEASE PROVIDE A SITE PLAN/SURVEY SHOWING THE
 LOCATION OF THE FLAG POLE - WITH DIMENSIONS FROM THE
 BUILDING, PROPERTY LINES ETC..
 2) FLAG POLE IS SUBJECT TO WIND LOADS.FBC 1609 PLEASE
 PROVIDE SIGNED AND SEALED DETAILS SHOWING THE
 FOUNDATION AND POLE ATTACHMENT REQUIREMENTS FROM A
 DESIGN PROFESSIONAL.
 3) PLEASE SHOW THE WIND DESIGN DATA USED FOR DESIGN PER
 FBC 1603.1.4
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2021-05-18 Cont ID  
Sent By lmarchan Date 2021-05-18 Time 16:18 Rev Time 0.00
Received By lmarchan Date 2021-04-19 Time 12:41 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2021-04-01 Cont ID  
Sent By equinone Date 2021-04-01 Time 09:32 Rev Time 0.00
Received By equinone Date 2021-03-04 Time 15:31 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 4 Status P Date 2021-05-27 Cont ID  
Sent By jgomez Date 2021-05-27 Time 10:04 Rev Time 0.00
Received By jgomez Date 2021-05-27 Time 09:31 Sent To  
Notes
2021-05-27 10:06:10FLAG POLE ENGINEERING WITH ENGINEER'S ORIGINAL
 SEAL/SIGNATURE MATCHES APPROVED ONE. JG.

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status P Date 2021-05-27 Cont ID  
Sent By jgomez Date 2021-05-26 Time 12:52 Rev Time 0.00
Received By jgomez Date 2021-05-26 Time 12:43 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status F Date 2021-04-30 Cont ID  
Sent By rmcphers Date 2021-04-30 Time 13:50 Rev Time 0.00
Received By rmcphers Date 2021-04-30 Time 13:50 Sent To  
Notes
2021-04-30 13:51:36SIGNED AND SEALED DRAWINGS IN PROJECTDOX NEED TO BE
 DIGITALLY/ELECTRONICALLY SIGNED BY THE ENGINEER OR
 ARCHITECT TO BE USED IN ELECTRONIC PLAN REVIEW.
 DRAWINGS DO NOT SHOW IN "ADOBE READER" AS
 DIGITALLY/ELECTRONICALLY SIGNED. - OR - IF YOUR
 ARCHITECT OR ENGINEER DOES NOT HAVE AN ELECTRONIC OR
 DIGITAL SIGNATURE - YOU CAN MAIL IN OR DROP OFF THE
 ORIGINAL SIGNED AND SEALED DRAWINGS/DOCUMENTS TO THE
 FRONT DESK IN THE BUILDING DEPT. AT THE CITY HALL

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2021-03-26 Cont ID  
Sent By rmcphers Date 2021-03-26 Time 11:27 Rev Time 0.00
Received By rmcphers Date 2021-03-26 Time 11:27 Sent To  
Notes
2021-03-26 11:27:48SEE BUILDING PLAN REVIEW

Review Stop Z ZONING
Rev No 2 Status P Date 2021-05-18 Cont ID  
Sent By aaponte Date 2021-05-18 Time 14:54 Rev Time 0.00
Received By aaponte Date 2021-05-18 Time 14:54 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2021-03-31 Cont ID  
Sent By aaponte Date 2021-03-31 Time 09:21 Rev Time 0.00
Received By aaponte Date 2021-03-31 Time 09:21 Sent To  
Notes
2021-03-31 09:32:511. PLEASE PROVIDE A SITE PLAN AND SURVEY INDICATING THE
 LOCATION OF THE FLAG POLE.
 2. POLE SHALL BE NOT BE LOCATED WITHIN THE SETBACKS.
 FOR THIS DISTRICT THE MINIMUM SETBACKS ARE 24 FEET FROM
 FALGLER DRIVE AS MEASURED FROM BACK OF EXISTING CURB;
 AND 20 FEET FROM THE WATER FACE OF THE SEAWALL CAP.
 FOR ADDITIONAL INFORMATION PLEASE CONTACT ANA MARIA
 APONTE AT 561-822-1439.