Plan Review Details - Permit 21030131
| Plan Review Stops For Permit 21030131 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2021-04-07 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-04-07 |
Time |
12:41 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-04-07 |
Time |
12:41 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2021-03-31 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-03-31 |
Time |
14:46 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-03-31 |
Time |
14:46 |
Sent To |
|
|
| Notes |
| 2021-03-31 14:55:10 | WINDOWS AND DOORS | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected] | | | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 | | | AMENDMENTS | | | | | | CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107 | | | 1) FLOOR PLAN SHOWS BEDROOM WINDOWS 12,13,14, AND 15 AS | | | FIXED GLASS WINDOWS - BEDROOMS NEED TO COMPLY WITH FBC | | | R310.2.5 | | | 2) A SINGLE HUNG WINDOW PRODUCT APPROVAL IS PROVIDED - | | | THE FLOOR PLAN DRAWINGS DO NOT SHOW A SINGLE HUNG | | | WINDOW - PLEASE CLARIFY. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2021-03-12 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-03-12 |
Time |
14:37 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-03-12 |
Time |
14:16 |
Sent To |
|
|
| Notes |
| 2021-03-12 14:37:26 | WINDOWS AND DOORS | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected] | | | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 | | | AMENDMENTS | | | | | | CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107 | | | 1) DRAWINGS NEED TO SHOW THE WINDOW AND DOOR SIZES AND | | | TYPE ALONG WITH THE LOCATION FOR EACH TYPE. | | | 2) PLEASE PROVIDE THE MIAMI DADE OR FLORIDA STATE FRONT | | | PAGES OF THE PRODUCT APPROVAL FOR THE (SS-3500 IMPACT | | | RESISTANT STORE FRONT WINDOW SYSTEM). | | | 3) DRAWINGS SHOW WIND DESIGN PER ASCE 7-10 - SHOULD BE | | | ASCE 7-16 PER 2020 FBC | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2021-04-07 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-04-07 |
Time |
12:41 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-04-06 |
Time |
10:33 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2021-03-31 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-03-31 |
Time |
15:00 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-03-26 |
Time |
15:51 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2021-03-12 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-03-12 |
Time |
14:39 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-03-03 |
Time |
16:08 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
P |
Date |
2021-04-07 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-04-07 |
Time |
12:41 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-04-07 |
Time |
12:41 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2021-03-31 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-03-31 |
Time |
15:00 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-03-31 |
Time |
14:59 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2021-03-12 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-03-12 |
Time |
14:37 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-03-12 |
Time |
14:37 |
Sent To |
|
|
| Notes |
| 2021-03-12 14:38:18 | SIGNED AND SEALED DRAWINGS IN PROJECTDOX NEED TO BE | | | DIGITALLY/ELECTRONICALLY SIGNED BY THE ENGINEER OR | | | ARCHITECT TO BE USED IN ELECTRONIC PLAN REVIEW. | | | DRAWINGS DO NOT SHOW IN "ADOBE READER" AS | | | DIGITALLY/ELECTRONICALLY SIGNED. - OR - IF YOUR | | | ARCHITECT OR ENGINEER DOES NOT HAVE AN ELECTRONIC OR | | | DIGITAL SIGNATURE ? YOU CAN MAIL IN OR DROP OFF THE | | | ORIGINAL SIGNED AND SEALED DRAWINGS/DOCUMENTS TO THE | | | FRONT DESK IN THE BUILDING DEPT. AT THE CITY HALL |
|
|
|