Plan Review Details - Permit 21030056
| Plan Review Stops For Permit 21030056 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2021-04-01 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-04-01 |
Time |
10:27 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-04-01 |
Time |
10:27 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2021-03-17 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-03-17 |
Time |
14:49 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-03-17 |
Time |
14:40 |
Sent To |
|
|
| Notes |
| 2021-03-17 14:48:51 | ELEVATOR | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected] | | | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 | | | AMENDMENTS | | | | | | CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107 | | | 1) DRAWINGS PROVIDED ARE NOT READABLE - PLEASE PROVIDE | | | A CLEAR COPY OF THE DRAWINGS. | | | 2) PLEASE PROVIDE A FLOOR PLAN SHOWING THE LOCATION OF | | | THE ELEVATOR AND THE LANDINGS FOR THE ELEVATOR. | | | 3) CODE IN EFFECT FOR WHICH THE ELEVATOR IS DESIGNED | | | FOR SHOULD BE SHOWN ON THE DRAWINGS. | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2021-03-30 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2021-03-30 |
Time |
08:04 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2021-03-30 |
Time |
08:02 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2021-03-10 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2021-03-10 |
Time |
13:45 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2021-03-10 |
Time |
13:44 |
Sent To |
|
|
| Notes |
| 2021-03-10 13:46:24 | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | FLORIDA BUILDING CODE 2020 7TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 7TH ED | | | NFPA 70 2017 EDITION | | | | | | JAKE LEAHY BN, BU, PX | | | ELECTRICAL PLANS EXAMINER II | | | 561-805-6713 | | | [email protected] | | | | | | NO ELECTRIC SHOWN, PLEASE INDICATE THE BRANCH CIRCUIT | | | SIZE, WIRE, AND OVERCURRENT SIZE. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2021-04-01 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-04-01 |
Time |
10:28 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-03-25 |
Time |
09:35 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2021-03-17 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-03-17 |
Time |
14:49 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-03-05 |
Time |
16:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2021-04-01 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-04-01 |
Time |
10:27 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-04-01 |
Time |
10:27 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2021-03-17 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-03-17 |
Time |
14:49 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-03-17 |
Time |
14:49 |
Sent To |
|
|
| Notes |
| 2021-03-17 14:49:28 | SIGNED AND SEALED DRAWINGS IN PROJECTDOX NEED TO BE | | | DIGITALLY/ELECTRONICALLY SIGNED BY THE ENGINEER OR | | | ARCHITECT TO BE USED IN ELECTRONIC PLAN REVIEW. | | | DRAWINGS DO NOT SHOW IN "ADOBE READER" AS | | | DIGITALLY/ELECTRONICALLY SIGNED. - OR - IF YOUR | | | ARCHITECT OR ENGINEER DOES NOT HAVE AN ELECTRONIC OR | | | DIGITAL SIGNATURE - YOU CAN MAIL IN OR DROP OFF THE | | | ORIGINAL SIGNED AND SEALED DRAWINGS/DOCUMENTS TO THE | | | FRONT DESK IN THE BUILDING DEPT. AT THE CITY HALL |
|
|
|