| Plan Review Stops For Permit 21021430 |
| Review Stop |
AD |
ADDRESSING |
| Rev No |
4 |
Status |
F |
Date |
2022-10-18 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2022-10-18 |
Time |
07:51 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2022-10-18 |
Time |
07:51 |
Sent To |
|
|
| Notes |
| 2022-10-18 07:51:29 | PREVIOUS COMMENTS NOT ADDRESSED |
|
|
| Review Stop |
AD |
ADDRESSING |
| Rev No |
3 |
Status |
F |
Date |
2022-02-08 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2022-02-08 |
Time |
15:35 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2022-02-08 |
Time |
15:35 |
Sent To |
|
|
| Notes |
| 2022-02-08 15:35:19 | PLEASE COORDINATE WITH [email protected] FOR THE HABITABLE | | | SPACE TO BE GIVEN AN ADDRESS. ALL ACCESSORY | | | RESIDENTIAL/COMMERCIAL UNITS AND OR OTHER HABITABLE | | | STRUCTURES WILL BE ISSUED A UNIQUE SECONDARY ADDRESS | | | NUMBER PER CITY'S ADDRESSING POLICY. PLEASE HAVE THE | | | OWNER CONTACT [email protected] OR CALL 561-805-6659 TO | | | READDRESS THE HABITABLE BUILDING. |
|
|
| Review Stop |
AD |
ADDRESSING |
| Rev No |
2 |
Status |
F |
Date |
2021-10-13 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2021-10-13 |
Time |
11:39 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2021-10-13 |
Time |
11:39 |
Sent To |
|
|
| Notes |
| 2021-10-13 11:40:11 | PLEASE COORDINATE WITH [email protected] FOR THE LIVABLE | | | SPACE TO BE GIVEN AN ADDRESS. ALL ACCESSORY | | | RESIDENTIAL/COMMERCIAL UNITS AND OR OTHER HABITABLE | | | STRUCTURES WILL BE ISSUED A UNIQUE SECONDARY ADDRESS | | | NUMBER PER CITY'S ADDRESSING POLICY. |
|
|
| Review Stop |
AD |
ADDRESSING |
| Rev No |
1 |
Status |
F |
Date |
2021-03-08 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2021-03-08 |
Time |
14:32 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2021-03-08 |
Time |
14:32 |
Sent To |
|
|
| Notes |
| 2021-03-08 14:32:48 | PLEASE COORDINATE WITH [email protected] FOR THE LIVABLE | | | SPACE TO BE GIVEN AN ADDRESS. ALL ACCESSORY | | | RESIDENTIAL/COMMERCIAL UNITS AND OR OTHER HABITABLE | | | STRUCTURES WILL BE ISSUED A UNIQUE SECONDARY ADDRESS | | | NUMBER PER CITY'S ADDRESSING POLICY. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
F |
Date |
2022-11-16 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-11-16 |
Time |
13:19 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-11-16 |
Time |
12:14 |
Sent To |
|
|
| Notes |
| 2022-11-16 13:20:18 | PLAN REVIEW BUILDING | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | PLANS EXAMINER PX3169 1&2 FAMILY - SFP306 | | | INSPECTOR BN4338 | | | BUILDING OFFICIAL BU1635 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | CODES IN EFFECT: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | 2017 NEC | | | | | | 4TH REVIEW | | | | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | NOTICE: COMMENTS FROM 3RD BUILDING REVIEW HAVE NOT BEEN | | | ADDRESSED. SEE BELOW: | | | | | | | | | NOTICE: NEW PLAN PAGE S-1 INDICATES A 1-STORY STRUCTURE | | | BUT THE ELEVATION DRAWING INDICATES A 2-STORY | | | STRUCTURE. PLEASE CLARIFY. | | | | | | PLEASE ADDRESS COMMENTS FROM 1ST REVIEW BEFORE | | | RE-SUBMITTING. | | | | | | | | | REF. PLAN PAGE S1-1 FOR THE FOLLOWING: | | | | | | 1. APPLICATION STATES 800 SF ACCESS. STRUCTURE. DESIGN | | | INFORMATION APPEARS TO BE PROPERTY INFORMATION FOR | | | EXISTING SFR. PROVIDE DESIGN PARAMETERS FOR NEW 2 STORY | | | ACCESSORY STRUCTURE. | | | 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS | | | SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH | | | 107.2.5. | | | | | | 2. ALL PLANS (FLOOR PLAN, SECTION VIEW AND ELEVATIONS) | | | SHALL BE DEMENSIONED. CANNOT VERIFY SF OF ACCESS. | | | STRUCTURE. | | | 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS | | | SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH | | | 107.2.5. | | | | | | 3. SOW IS CONSTRUCTION OF A RESIDENTIAL ACCESSORY | | | STRUCTURE: NEW TYPE: 328 - STORAGE/GARAGE/SHED. THIS IS | | | NOT AN ADDITION. THE 2020 FBC EXISTING BLDG. DOES NOT | | | APPLY. | | | GOVERNING CODES ARE: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | 2017 NEC | | | | | | 4. PROVIDE FINISHED FLOOR ELEVATION. | | | R403.1.7.3 FOUNDATION ELEVATION. | | | ON GRADED SITES, THE TOP OF ANY EXTERIOR FOUNDATION | | | SHALL EXTEND ABOVE THE ELEVATION OF THE STREET GUTTER | | | AT POINT OF DISCHARGE OR THE INLET OF AN APPROVED | | | DRAINAGE DEVICE A MINIMUM OF 12 INCHES (305 MM) PLUS 2 | | | PERCENT. ALTERNATE ELEVATIONS ARE PERMITTED SUBJECT TO | | | THE APPROVAL OF THE BUILDING OFFICIAL, PROVIDED IT CAN | | | BE DEMONSTRATED THAT REQUIRED DRAINAGE TO THE POINT OF | | | DISCHARGE AND AWAY FROM THE STRUCTURE IS PROVIDED AT | | | ALL LOCATIONS ON THE SITE. | | | | | | FINISHED FLOOR ELEVATIONS SHALL BE PLACED ON FOUNDATION | | | PLAN AND/OR FLOOR PLAN. | | | | | | REF. PLAN PAGE S1-2 FOR THE FOLLOWING: | | | | | | 5. 2 STORY WALL SECTION INDICATES THE FOOTING AND 8 | | | INCH CMU WALLS ARE EXISTING. THIS IS A NEW STRUCTURE. | | | 5A) PROVIDE A FOUNDATION PLAN | | | 5B) PROVIDE EXT. WALL SECTION DETAIL. | | | 5C) PROVIDE ROOF FRAMING PLAN WITH DESIGN CRITERIA. | | | | | | GENERAL COMMENTS: | | | | | | 6. PROVIDE A SITE PLAN. | | | 107.2.5 SITE PLAN. THE CONSTRUCTION DOCUMENTS SUBMITTED | | | WITH THE APPLICATION FOR PERMIT SHALL BE ACCOMPANIED BY | | | A SITE PLAN SHOWING TO SCALE THE SIZE AND LOCATION OF | | | NEW CONSTRUCTION AND EXISTING STRUCTURES ON THE | | | SITE,... AND IT SHALL BE DRAWN IN ACCORDANCE WITH AN | | | ACCURATE AND INCLUDED BOUNDARY LINE SURVEY. | | | | | | 7. PROVIDE A SITE DRAINAGE PLAN. | | | FBC R401.3 SITE DRAINAGE | | | PROVIDE A SITE DRAINAGE PLAN SHOWING COMPLIANCE WITH | | | FBC R401.3 DRAINAGE. | | | SURFACE DRAINAGE SHALL BE DIVERTED TO A STORM SEWER | | | CONVEYANCE OR OTHER APPROVED POINT OF COLLECTION THAT | | | DOES NOT CREATE A HAZARD. | | | LOTS SHALL BE GRADED TO DRAIN SURFACE WATER AWAY FROM | | | FOUNDATION WALLS. THE GRADE SHALL FALL A MINIMUM OF 6 | | | INCHES WITHIN THE FIRST 10 FEET. | | | | | | 8. PROVIDE AN ENERGY SUBMITTAL. | | | FBCE-101.5.1.1.2 SIMULATED PERFORMANCE ALTERNATIVE. | | | AN ACCURATELY COMPLETED RESIDENTIAL BUILDING FORM R405 | | | (GENERATED BY COMMISSION APPROVED SOFTWARE) SHALL BE | | | SUBMITTED TO THE BUILDING OFFICIAL TO DEMONSTRATE CODE | | | COMPLIANCE BY SECTION 405. | | | | | | 9. A SOILS REPORT MAY BE REQUIRED. | | | R401.4 SOIL TESTS. | | | WHERE QUANTIFIABLE DATA CREATED BY ACCEPTED SOIL | | | SCIENCE METHODOLOGIES INDICATE EXPANSIVE, COMPRESSIBLE, | | | SHIFTING OR OTHER QUESTIONABLE SOIL CHARACTERISTICS ARE | | | LIKELY TO BE PRESENT, THE BUILDING OFFICIAL SHALL | | | DETERMINE WHETHER TO REQUIRE A SOIL TEST TO DETERMINE | | | THE SOIL?S CHARACTERISTICS AT A PARTICULAR LOCATION. | | | THIS TEST SHALL BE DONE BY AN APPROVED AGENCY USING AN | | | APPROVED METHOD. | | | | | | 10. PROVIDE PRODUCT APPROVALS FOR WINDOWS AND DOORS. | | | FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE | | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | SPECIFICALLY, PROVIDE WINDOW AND DOOR SUBMITTALS. | | | | | | 11. VALUE CANNOT BE DETERMINED AT THIS TIME. RE-SUBMIT | | | WITH BUILDING DESIGN PARAMETERS. | | | 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS | | | SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH | | | 107.2.5. | | | | | | NOTICE: A SEPERATE ROOFING PERMIT SHALL BE REQUIRED. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | WHEN RESUBMITING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2022-04-15 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-04-15 |
Time |
09:44 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-04-14 |
Time |
17:12 |
Sent To |
|
|
| Notes |
| 2022-04-15 09:45:45 | PLAN REVIEW BUILDING | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | PLANS EXAMINER PX3169 1&2 FAMILY - SFP306 | | | INSPECTOR BN4338 | | | BUILDING OFFICIAL BU1635 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | CODES IN EFFECT: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | 2017 NEC | | | | | | 3RD REVIEW | | | | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | NOTICE: COMMENTS FROM 2ND BUILDING REVIEW HAVE NOT BEEN | | | ADDRESSED. SEE BELOW: | | | | | | | | | NOTICE: NEW PLAN PAGE S-1 INDICATES A 1-STORY STRUCTURE | | | BUT THE ELEVATION DRAWING INDICATES A 2-STORY | | | STRUCTURE. PLEASE CLARIFY. | | | | | | PLEASE ADDRESS COMMENTS FROM 1ST REVIEW BEFORE | | | RE-SUBMITTING. | | | | | | | | | REF. PLAN PAGE S1-1 FOR THE FOLLOWING: | | | | | | 1. APPLICATION STATES 800 SF ACCESS. STRUCTURE. DESIGN | | | INFORMATION APPEARS TO BE PROPERTY INFORMATION FOR | | | EXISTING SFR. PROVIDE DESIGN PARAMETERS FOR NEW 2 STORY | | | ACCESSORY STRUCTURE. | | | 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS | | | SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH | | | 107.2.5. | | | | | | 2. ALL PLANS (FLOOR PLAN, SECTION VIEW AND ELEVATIONS) | | | SHALL BE DEMENSIONED. CANNOT VERIFY SF OF ACCESS. | | | STRUCTURE. | | | 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS | | | SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH | | | 107.2.5. | | | | | | 3. SOW IS CONSTRUCTION OF A RESIDENTIAL ACCESSORY | | | STRUCTURE: NEW TYPE: 328 - STORAGE/GARAGE/SHED. THIS IS | | | NOT AN ADDITION. THE 2020 FBC EXISTING BLDG. DOES NOT | | | APPLY. | | | GOVERNING CODES ARE: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | 2017 NEC | | | | | | 4. PROVIDE FINISHED FLOOR ELEVATION. | | | R403.1.7.3 FOUNDATION ELEVATION. | | | ON GRADED SITES, THE TOP OF ANY EXTERIOR FOUNDATION | | | SHALL EXTEND ABOVE THE ELEVATION OF THE STREET GUTTER | | | AT POINT OF DISCHARGE OR THE INLET OF AN APPROVED | | | DRAINAGE DEVICE A MINIMUM OF 12 INCHES (305 MM) PLUS 2 | | | PERCENT. ALTERNATE ELEVATIONS ARE PERMITTED SUBJECT TO | | | THE APPROVAL OF THE BUILDING OFFICIAL, PROVIDED IT CAN | | | BE DEMONSTRATED THAT REQUIRED DRAINAGE TO THE POINT OF | | | DISCHARGE AND AWAY FROM THE STRUCTURE IS PROVIDED AT | | | ALL LOCATIONS ON THE SITE. | | | | | | FINISHED FLOOR ELEVATIONS SHALL BE PLACED ON FOUNDATION | | | PLAN AND/OR FLOOR PLAN. | | | | | | REF. PLAN PAGE S1-2 FOR THE FOLLOWING: | | | | | | 5. 2 STORY WALL SECTION INDICATES THE FOOTING AND 8 | | | INCH CMU WALLS ARE EXISTING. THIS IS A NEW STRUCTURE. | | | 5A) PROVIDE A FOUNDATION PLAN | | | 5B) PROVIDE EXT. WALL SECTION DETAIL. | | | 5C) PROVIDE ROOF FRAMING PLAN WITH DESIGN CRITERIA. | | | | | | GENERAL COMMENTS: | | | | | | 6. PROVIDE A SITE PLAN. | | | 107.2.5 SITE PLAN. THE CONSTRUCTION DOCUMENTS SUBMITTED | | | WITH THE APPLICATION FOR PERMIT SHALL BE ACCOMPANIED BY | | | A SITE PLAN SHOWING TO SCALE THE SIZE AND LOCATION OF | | | NEW CONSTRUCTION AND EXISTING STRUCTURES ON THE | | | SITE,... AND IT SHALL BE DRAWN IN ACCORDANCE WITH AN | | | ACCURATE AND INCLUDED BOUNDARY LINE SURVEY. | | | | | | 7. PROVIDE A SITE DRAINAGE PLAN. | | | FBC R401.3 SITE DRAINAGE | | | PROVIDE A SITE DRAINAGE PLAN SHOWING COMPLIANCE WITH | | | FBC R401.3 DRAINAGE. | | | SURFACE DRAINAGE SHALL BE DIVERTED TO A STORM SEWER | | | CONVEYANCE OR OTHER APPROVED POINT OF COLLECTION THAT | | | DOES NOT CREATE A HAZARD. | | | LOTS SHALL BE GRADED TO DRAIN SURFACE WATER AWAY FROM | | | FOUNDATION WALLS. THE GRADE SHALL FALL A MINIMUM OF 6 | | | INCHES WITHIN THE FIRST 10 FEET. | | | | | | 8. PROVIDE AN ENERGY SUBMITTAL. | | | FBCE-101.5.1.1.2 SIMULATED PERFORMANCE ALTERNATIVE. | | | AN ACCURATELY COMPLETED RESIDENTIAL BUILDING FORM R405 | | | (GENERATED BY COMMISSION APPROVED SOFTWARE) SHALL BE | | | SUBMITTED TO THE BUILDING OFFICIAL TO DEMONSTRATE CODE | | | COMPLIANCE BY SECTION 405. | | | | | | 9. A SOILS REPORT MAY BE REQUIRED. | | | R401.4 SOIL TESTS. | | | WHERE QUANTIFIABLE DATA CREATED BY ACCEPTED SOIL | | | SCIENCE METHODOLOGIES INDICATE EXPANSIVE, COMPRESSIBLE, | | | SHIFTING OR OTHER QUESTIONABLE SOIL CHARACTERISTICS ARE | | | LIKELY TO BE PRESENT, THE BUILDING OFFICIAL SHALL | | | DETERMINE WHETHER TO REQUIRE A SOIL TEST TO DETERMINE | | | THE SOIL?S CHARACTERISTICS AT A PARTICULAR LOCATION. | | | THIS TEST SHALL BE DONE BY AN APPROVED AGENCY USING AN | | | APPROVED METHOD. | | | | | | 10. PROVIDE PRODUCT APPROVALS FOR WINDOWS AND DOORS. | | | FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE | | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | SPECIFICALLY, PROVIDE WINDOW AND DOOR SUBMITTALS. | | | | | | 11. VALUE CANNOT BE DETERMINED AT THIS TIME. RE-SUBMIT | | | WITH BUILDING DESIGN PARAMETERS. | | | 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS | | | SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH | | | 107.2.5. | | | | | | NOTICE: A SEPERATE ROOFING PERMIT SHALL BE REQUIRED. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | WHEN RESUBMITING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2021-12-06 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-12-06 |
Time |
11:07 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-12-06 |
Time |
07:45 |
Sent To |
|
|
| Notes |
| 2021-12-06 11:09:23 | PLAN REVIEW BUILDING | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | PLANS EXAMINER PX3169 1&2 FAMILY - SFP306 | | | INSPECTOR BN4338 | | | BUILDING OFFICIAL BU1635 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | CODES IN EFFECT: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | 2017 NEC | | | | | | 2ND REVIEW | | | | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | NOTICE: NEW PLAN PAGE S-1 INDICATES A 1-STORY STRUCTURE | | | BUT THE ELEVATION DRAWING INDICATES A 2-STORY | | | STRUCTURE. PLEASE CLARIFY. | | | | | | PLEASE ADDRESS COMMENTS FROM 1ST REVIEW BEFORE | | | RE-SUBMITTING. | | | | | | | | | REF. PLAN PAGE S1-1 FOR THE FOLLOWING: | | | | | | 1. APPLICATION STATES 800 SF ACCESS. STRUCTURE. DESIGN | | | INFORMATION APPEARS TO BE PROPERTY INFORMATION FOR | | | EXISTING SFR. PROVIDE DESIGN PARAMETERS FOR NEW 2 STORY | | | ACCESSORY STRUCTURE. | | | 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS | | | SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH | | | 107.2.5. | | | | | | 2. ALL PLANS (FLOOR PLAN, SECTION VIEW AND ELEVATIONS) | | | SHALL BE DEMENSIONED. CANNOT VERIFY SF OF ACCESS. | | | STRUCTURE. | | | 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS | | | SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH | | | 107.2.5. | | | | | | 3. SOW IS CONSTRUCTION OF A RESIDENTIAL ACCESSORY | | | STRUCTURE: NEW TYPE: 328 - STORAGE/GARAGE/SHED. THIS IS | | | NOT AN ADDITION. THE 2020 FBC EXISTING BLDG. DOES NOT | | | APPLY. | | | GOVERNING CODES ARE: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | 2017 NEC | | | | | | 4. PROVIDE FINISHED FLOOR ELEVATION. | | | R403.1.7.3 FOUNDATION ELEVATION. | | | ON GRADED SITES, THE TOP OF ANY EXTERIOR FOUNDATION | | | SHALL EXTEND ABOVE THE ELEVATION OF THE STREET GUTTER | | | AT POINT OF DISCHARGE OR THE INLET OF AN APPROVED | | | DRAINAGE DEVICE A MINIMUM OF 12 INCHES (305 MM) PLUS 2 | | | PERCENT. ALTERNATE ELEVATIONS ARE PERMITTED SUBJECT TO | | | THE APPROVAL OF THE BUILDING OFFICIAL, PROVIDED IT CAN | | | BE DEMONSTRATED THAT REQUIRED DRAINAGE TO THE POINT OF | | | DISCHARGE AND AWAY FROM THE STRUCTURE IS PROVIDED AT | | | ALL LOCATIONS ON THE SITE. | | | | | | FINISHED FLOOR ELEVATIONS SHALL BE PLACED ON FOUNDATION | | | PLAN AND/OR FLOOR PLAN. | | | | | | REF. PLAN PAGE S1-2 FOR THE FOLLOWING: | | | | | | 5. 2 STORY WALL SECTION INDICATES THE FOOTING AND 8 | | | INCH CMU WALLS ARE EXISTING. THIS IS A NEW STRUCTURE. | | | 5A) PROVIDE A FOUNDATION PLAN | | | 5B) PROVIDE EXT. WALL SECTION DETAIL. | | | 5C) PROVIDE ROOF FRAMING PLAN WITH DESIGN CRITERIA. | | | | | | GENERAL COMMENTS: | | | | | | 6. PROVIDE A SITE PLAN. | | | 107.2.5 SITE PLAN. THE CONSTRUCTION DOCUMENTS SUBMITTED | | | WITH THE APPLICATION FOR PERMIT SHALL BE ACCOMPANIED BY | | | A SITE PLAN SHOWING TO SCALE THE SIZE AND LOCATION OF | | | NEW CONSTRUCTION AND EXISTING STRUCTURES ON THE | | | SITE,... AND IT SHALL BE DRAWN IN ACCORDANCE WITH AN | | | ACCURATE AND INCLUDED BOUNDARY LINE SURVEY. | | | | | | 7. PROVIDE A SITE DRAINAGE PLAN. | | | FBC R401.3 SITE DRAINAGE | | | PROVIDE A SITE DRAINAGE PLAN SHOWING COMPLIANCE WITH | | | FBC R401.3 DRAINAGE. | | | SURFACE DRAINAGE SHALL BE DIVERTED TO A STORM SEWER | | | CONVEYANCE OR OTHER APPROVED POINT OF COLLECTION THAT | | | DOES NOT CREATE A HAZARD. | | | LOTS SHALL BE GRADED TO DRAIN SURFACE WATER AWAY FROM | | | FOUNDATION WALLS. THE GRADE SHALL FALL A MINIMUM OF 6 | | | INCHES WITHIN THE FIRST 10 FEET. | | | | | | 8. PROVIDE AN ENERGY SUBMITTAL. | | | FBCE-101.5.1.1.2 SIMULATED PERFORMANCE ALTERNATIVE. | | | AN ACCURATELY COMPLETED RESIDENTIAL BUILDING FORM R405 | | | (GENERATED BY COMMISSION APPROVED SOFTWARE) SHALL BE | | | SUBMITTED TO THE BUILDING OFFICIAL TO DEMONSTRATE CODE | | | COMPLIANCE BY SECTION 405. | | | | | | 9. A SOILS REPORT MAY BE REQUIRED. | | | R401.4 SOIL TESTS. | | | WHERE QUANTIFIABLE DATA CREATED BY ACCEPTED SOIL | | | SCIENCE METHODOLOGIES INDICATE EXPANSIVE, COMPRESSIBLE, | | | SHIFTING OR OTHER QUESTIONABLE SOIL CHARACTERISTICS ARE | | | LIKELY TO BE PRESENT, THE BUILDING OFFICIAL SHALL | | | DETERMINE WHETHER TO REQUIRE A SOIL TEST TO DETERMINE | | | THE SOIL?S CHARACTERISTICS AT A PARTICULAR LOCATION. | | | THIS TEST SHALL BE DONE BY AN APPROVED AGENCY USING AN | | | APPROVED METHOD. | | | | | | 10. PROVIDE PRODUCT APPROVALS FOR WINDOWS AND DOORS. | | | FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE | | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | SPECIFICALLY, PROVIDE WINDOW AND DOOR SUBMITTALS. | | | | | | 11. VALUE CANNOT BE DETERMINED AT THIS TIME. RE-SUBMIT | | | WITH BUILDING DESIGN PARAMETERS. | | | 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS | | | SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH | | | 107.2.5. | | | | | | NOTICE: A SEPERATE ROOFING PERMIT SHALL BE REQUIRED. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | WHEN RESUBMITING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2021-04-02 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-04-02 |
Time |
09:23 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-04-02 |
Time |
07:02 |
Sent To |
|
|
| Notes |
| 2021-04-02 09:55:21 | PLAN REVIEW BUILDING | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | PLANS EXAMINER PX3169 1&2 FAMILY - SFP306 | | | INSPECTOR BN4338 | | | BUILDING OFFICIAL BU1635 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | CODES IN EFFECT: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | 2017 NEC | | | | | | 1ST REVIEW | | | | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | NOTICE: TOO MUCH CONFLICTING INFORMATION TO PERFORM | | | COMPREHENSIVE BLDG. REVIEW. | | | | | | REF. PLAN PAGE S1-1 FOR THE FOLLOWING: | | | | | | 1. APPLICATION STATES 800 SF ACCESS. STRUCTURE. DESIGN | | | INFORMATION APPEARS TO BE PROPERTY INFORMATION FOR | | | EXISTING SFR. PROVIDE DESIGN PARAMETERS FOR NEW 2 STORY | | | ACCESSORY STRUCTURE. | | | 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS | | | SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH | | | 107.2.5. | | | | | | 2. ALL PLANS (FLOOR PLAN, SECTION VIEW AND ELEVATIONS) | | | SHALL BE DEMENSIONED. CANNOT VERIFY SF OF ACCESS. | | | STRUCTURE. | | | 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS | | | SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH | | | 107.2.5. | | | | | | 3. SOW IS CONSTRUCTION OF A RESIDENTIAL ACCESSORY | | | STRUCTURE: NEW TYPE: 328 - STORAGE/GARAGE/SHED. THIS IS | | | NOT AN ADDITION. THE 2020 FBC EXISTING BLDG. DOES NOT | | | APPLY. | | | GOVERNING CODES ARE: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | 2017 NEC | | | | | | 4. PROVIDE FINISHED FLOOR ELEVATION. | | | R403.1.7.3 FOUNDATION ELEVATION. | | | ON GRADED SITES, THE TOP OF ANY EXTERIOR FOUNDATION | | | SHALL EXTEND ABOVE THE ELEVATION OF THE STREET GUTTER | | | AT POINT OF DISCHARGE OR THE INLET OF AN APPROVED | | | DRAINAGE DEVICE A MINIMUM OF 12 INCHES (305 MM) PLUS 2 | | | PERCENT. ALTERNATE ELEVATIONS ARE PERMITTED SUBJECT TO | | | THE APPROVAL OF THE BUILDING OFFICIAL, PROVIDED IT CAN | | | BE DEMONSTRATED THAT REQUIRED DRAINAGE TO THE POINT OF | | | DISCHARGE AND AWAY FROM THE STRUCTURE IS PROVIDED AT | | | ALL LOCATIONS ON THE SITE. | | | | | | FINISHED FLOOR ELEVATIONS SHALL BE PLACED ON FOUNDATION | | | PLAN AND/OR FLOOR PLAN. | | | | | | REF. PLAN PAGE S1-2 FOR THE FOLLOWING: | | | | | | 5. 2 STORY WALL SECTION INDICATES THE FOOTING AND 8 | | | INCH CMU WALLS ARE EXISTING. THIS IS A NEW STRUCTURE. | | | 5A) PROVIDE A FOUNDATION PLAN | | | 5B) PROVIDE EXT. WALL SECTION DETAIL. | | | 5C) PROVIDE ROOF FRAMING PLAN WITH DESIGN CRITERIA. | | | | | | GENERAL COMMENTS: | | | | | | 6. PROVIDE A SITE PLAN. | | | 107.2.5 SITE PLAN. THE CONSTRUCTION DOCUMENTS SUBMITTED | | | WITH THE APPLICATION FOR PERMIT SHALL BE ACCOMPANIED BY | | | A SITE PLAN SHOWING TO SCALE THE SIZE AND LOCATION OF | | | NEW CONSTRUCTION AND EXISTING STRUCTURES ON THE | | | SITE,... AND IT SHALL BE DRAWN IN ACCORDANCE WITH AN | | | ACCURATE AND INCLUDED BOUNDARY LINE SURVEY. | | | | | | 7. PROVIDE A SITE DRAINAGE PLAN. | | | FBC R401.3 SITE DRAINAGE | | | PROVIDE A SITE DRAINAGE PLAN SHOWING COMPLIANCE WITH | | | FBC R401.3 DRAINAGE. | | | SURFACE DRAINAGE SHALL BE DIVERTED TO A STORM SEWER | | | CONVEYANCE OR OTHER APPROVED POINT OF COLLECTION THAT | | | DOES NOT CREATE A HAZARD. | | | LOTS SHALL BE GRADED TO DRAIN SURFACE WATER AWAY FROM | | | FOUNDATION WALLS. THE GRADE SHALL FALL A MINIMUM OF 6 | | | INCHES WITHIN THE FIRST 10 FEET. | | | | | | 8. PROVIDE AN ENERGY SUBMITTAL. | | | FBCE-101.5.1.1.2 SIMULATED PERFORMANCE ALTERNATIVE. | | | AN ACCURATELY COMPLETED RESIDENTIAL BUILDING FORM R405 | | | (GENERATED BY COMMISSION APPROVED SOFTWARE) SHALL BE | | | SUBMITTED TO THE BUILDING OFFICIAL TO DEMONSTRATE CODE | | | COMPLIANCE BY SECTION 405. | | | | | | 9. A SOILS REPORT MAY BE REQUIRED. | | | R401.4 SOIL TESTS. | | | WHERE QUANTIFIABLE DATA CREATED BY ACCEPTED SOIL | | | SCIENCE METHODOLOGIES INDICATE EXPANSIVE, COMPRESSIBLE, | | | SHIFTING OR OTHER QUESTIONABLE SOIL CHARACTERISTICS ARE | | | LIKELY TO BE PRESENT, THE BUILDING OFFICIAL SHALL | | | DETERMINE WHETHER TO REQUIRE A SOIL TEST TO DETERMINE | | | THE SOIL?S CHARACTERISTICS AT A PARTICULAR LOCATION. | | | THIS TEST SHALL BE DONE BY AN APPROVED AGENCY USING AN | | | APPROVED METHOD. | | | | | | 10. PROVIDE PRODUCT APPROVALS FOR WINDOWS AND DOORS. | | | FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE | | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | SPECIFICALLY, PROVIDE WINDOW AND DOOR SUBMITTALS. | | | | | | 11. VALUE CANNOT BE DETERMINED AT THIS TIME. RE-SUBMIT | | | WITH BUILDING DESIGN PARAMETERS. | | | 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS | | | SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH | | | 107.2.5. | | | | | | NOTICE: A SEPERATE ROOFING PERMIT SHALL BE REQUIRED. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | WHEN RESUBMITING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
F |
Date |
2022-11-01 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2022-11-01 |
Time |
14:38 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2022-11-01 |
Time |
14:30 |
Sent To |
|
|
| Notes |
| 2022-11-01 14:58:15 | ELECTRIC REVIEW FAILED | | | 1) IT APPEARS GUEST COTTAGE DETAILS MORE THAN ONE MULTI | | | WIRE CIRCUIT. PLEASE INDICATE THAT GUEST HOUSE HAS | | | SUBPANEL FOR GUEST HOUSE LOADS. AS PER NEC 225.30 | | | IN ADDITION, SINCE THIS GUEST HOUSE APPEARS IT WILL | | | REQUIRE AN ELECTRIC SUB PANEL, INDICATE THE NECESSARY | | | GROUNDING ELECTRODE SYSTEM AS PER NEC 250.32 | | | 2) PROVIDE AN ELECTRICAL RISER DIAGRAM DETAILING ALL | | | ELECTRIC EQIPMENT, METERS PANELS, CONDUIT ANND | | | CONDUCTOR SIZES AS NEC 215.5 | | | 3) PLEASE PROVIDE LOAD CALCULATIONS FOR ALL | | | DISTRIBUTION PANELS NEC 220 | | | 4) PLEASE LOCATE ALL ELECTRIC EQUIPMENT ON A SITE PLAN | | | FBC 107.3 | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. | | | | | | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2020 7TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE 2020 7TH ED. | | | FBC EB = FLORIDA BUILDING CODE EXISTING BUILDING 2020 | | | 7TH EDITION | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 | | | 7TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2020 7TH EDITION | | | NEC = NFPA 70 2017 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | V/R, | | | | | | MICHAEL PETERSON | | | ELECTRICAL PLANS EXAMINER | | | [email protected] | | | 561-805-6746 | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2022-02-25 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2022-02-25 |
Time |
14:00 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2022-02-25 |
Time |
14:00 |
Sent To |
|
|
| Notes |
| 2022-02-25 14:01:47 | ELECTRIC REVIEW FAILED | | | 1) PREVIOUS COMMENTS NOT ADDRESSED |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2021-11-08 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2021-11-08 |
Time |
12:37 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2021-11-08 |
Time |
12:36 |
Sent To |
|
|
| Notes |
| 2021-11-08 12:42:17 | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | FLORIDA BUILDING CODE 2020 7TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 7TH ED | | | NFPA 70 2017 EDITION | | | | | | JAKE LEAHY BN, BU, PX | | | ELECTRICAL PLANS EXAMINER II | | | 561-805-6713 | | | [email protected] | | | | | | DISCONNECT, PANEL, AND GROUNDING REQUIRED 225.30, | | | 225,31, 225,32 | | | | | | A BUILDING OR OTHER STRUCTURE THAT IS SERVED BY A | | | BRANCH CIRCUIT OR FEEDER ON THE LOAD SIDE OF A SERVICE | | | DISCONNECTING MEANS SHALL BE SUPPLIED BY ONLY ONE | | | FEEDER OR BRANCH CIRCUIT. NEC 225.30 | | | | | | PROVIDE GROUNDING ELECTRODE SYSTEM AS REQUIRED FOR A | | | BUILDING OR STRUCTURE SUPPLIED BY A FEEDER OR BRANCH | | | CIRCUIT. NEC 250.32; FBC | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2021-03-18 |
|
|
Cont ID |
|
| Sent By |
equinone |
Date |
2021-03-18 |
Time |
10:34 |
Rev Time |
0.00 |
| Received By |
equinone |
Date |
2021-03-18 |
Time |
10:34 |
Sent To |
|
|
| Notes |
| 2021-03-18 11:00:40 | CODES IN EFFECT | | | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2020 7TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2020 | | | 7TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 | | | 7TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2020 | | | 7TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2020 7TH EDITION | | | NEC = NFPA 70 2017 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | FAC = FLORIDA ADMINISTRATIVE CODE | | | | | | PERMIT: 21021430- ELECTRICAL REVIEW | | | | | | REVIEW STATUS: FAILED. PLEASE SEE COMMENTS BELOW: | | | | | | 1) SHEET S1-1: ELECTRICAL NOTES MENTION TO ADD | | | ELECTRICAL TO EXISTING ELECTRICAL PANEL. PLEASE SHOW | | | LOCATION OF THIS EXISTING ELECTRICAL PANEL. IS THE | | | EXISTING PANEL LOCATED AT THE MAIN RESIDENCE OR IS THIS | | | A SUBPANEL AT THE NEW STORAGE UNIT? IF THIS IS A | | | SUBPANEL LOCATED AT THE STORAGE UNIT, PLEASE PROVIDE A | | | RISER DIAGRAM SHOWING MAIN PANEL AND SUBPANEL WITH | | | FEEDER SIZES AND GROUNDING DETAILS. FBC 107 | | | 2) IT SEEMS THAT IN ADDITION TO THE LIGHTS AND | | | RECEPTACLES BEING INSTALLED THERE IS ALSO AN HVAC UNIT. | | | PLEASE SHOW DISCONNECT, ELECTRICAL CIRCUIT FOR THIS | | | UNIT, SPECIFY CONDUCTOR SIZES. PLEASE SHOW LOCATION OF | | | THE HVAC UNIT. FBC 107 | | | 3) GFCI/WP RECEPTACLE REQUIRED FOR HVAC UNIT. SHOW | | | LOCATION OF THIS RECEPTACLE. NEC 210.63 | | | 4) PLEASE PROVIDE A PANEL SCHEDULE OF THE EXISTING | | | PANEL SHOWING THE CIRCUITS FOR NEW STORAGE UNIT. | | | INCLUDE PANEL RATINGS AND MCB SIZE. FBC 107 | | | 5) RECEPTACLE IN BATHROOM MUST BE GFCI TYPE. NEC | | | 210.8(A)(1) | | | 6) ALL RECEPTACLES IN ACCESSORY UNIT (STORAGE ROOM) | | | MUST BE GFCI TYPE. NEC 210.8(A)(2) | | | 7) PLEASE INCLUDE LIST OF ELECTRICAL SYMBOLS BEING | | | USED. FBC 107 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | IF THE RESUBMITTAL IS NOT PREPARED BY A DESIGN | | | PROFESSIONAL (ARCHITECT OR ENGINEER), AND THE PAGES ARE | | | 11X17 OR SMALLER, YOU MAY RESUBMIT, ALONG WITH A | | | COMPLETED RESUBMITTAL FORM, VIA EMAIL TO | | | [email protected]. THE EMAIL SHOULD INCLUDE THE PERMIT | | | NUMBER AND "RESUBMITTAL" IN THE SUBJECT LINE. THE | | | RESUBMITTAL FORM CAN BE FOUND AT THIS WEBSITE: | | | | | | HTTPS://WWW.WPB.ORG/GOVERNMENT/DEVELOPMENT-SERVICES/FOR | | | MS | | | | | | ENRIQUE QUINONEZ P.E. | | | ELECTRICAL PLANS EXAMINER | | | DEVELOPMENT SERVICES | | | CITY OF WEST PAM BEACH | | | 401 CLEMATIS STREET, 1ST FLOOR | | | WEST PALM BEACH, FL 33401 | | | | | | FEEL FREE TO CONTACT ME IF YOU WISH TO DISCUSS, | | | 561-805-6746. | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2022-11-16 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-11-16 |
Time |
13:20 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-10-17 |
Time |
08:25 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2022-04-15 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-04-15 |
Time |
09:51 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-02-08 |
Time |
09:05 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2021-12-06 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-12-06 |
Time |
11:14 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-10-13 |
Time |
07:06 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2021-04-02 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-04-02 |
Time |
09:55 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-03-08 |
Time |
13:42 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2021-04-02 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-04-02 |
Time |
09:22 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-04-02 |
Time |
09:22 |
Sent To |
|
|
| Notes |
| 2021-04-02 09:22:58 | PALM BEACH COUNTY IMPACT FEES - DIGITAL SUBMITTALS | | | | | | PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE | | | DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS | | | OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST | | | FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE | | | OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL | | | IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME | | | THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM | | | CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS | | | TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF UPON | | | APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE RECEIPT TO | | | YOUR PROJECT OR EMAIL IT TO [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
F |
Date |
2022-11-02 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-11-02 |
Time |
12:35 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-11-02 |
Time |
12:35 |
Sent To |
|
|
| Notes |
| 2022-11-02 12:36:15 | 4TH REVIEW FMC | | | PERMIT: 21021430 | | | | | | CODES IN EFFECT: 2020 | | | | | | FBC- FLORIDA BUILDING CODE | | | FMC- FLORIDA MECHANICAL CODE | | | FEC- FLORIDA ENERGY CONSERVATION | | | FGC- FLORIDA FUEL GAS | | | FEX- FLORIDA EXISTING BUILDING CODE | | | FRC- FLORIDA RESIDENTIAL BUILDING CODE | | | F.S.- FLORIDA STATUTES | | | FAC- FLORIDA ACCESSIBILITY CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) THE MECHANICAL EQUIPMENT SIZING CALLS FOR 1.24 | | | NOMINAL TONS OF SENSIBLE COOLING. SHEET M-1 IN THE | | | MECHANICAL SCHEDULE CALLS FOR A 2-TON SYSTEM. PLEASE | | | SHOW HOW THIS MEETS THE REQUIREMENTS OF FEC | | | R403.7.1.2.2 BELOW: | | | | | | R403.7.1.2.1 HEAT PUMPS. HEAT PUMP SIZING SHALL BE | | | BASED ON THE COOLING REQUIREMENTS AS CALCULATED | | | ACCORDING TO SECTION R403.7.1.1, AND THE HEAT PUMP | | | TOTAL COOLING CAPACITY SHALL NOT BE MORE THAN 1.15 | | | TIMES GREATER THAN THE DESIGN COOLING LOAD EVEN IF THE | | | DESIGN HEATING LOAD IS 1.15 TIMES GREATER THAN THE | | | DESIGN COOLING LOAD. | | | | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM. | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
F |
Date |
2022-02-16 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-02-16 |
Time |
15:09 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-02-16 |
Time |
15:04 |
Sent To |
|
|
| Notes |
| 2022-02-16 15:09:21 | THE HVAC LOAD CALCULATIONS AND THE MECHANICAL DRAWING | | | DO NOT MATCH. PLEASE SUBMIT DOCUMENTS THAT MATCH EACH | | | OTHER. THE LOAD CALCULATIONS MENTION HYDRONIC BASEBOARD | | | HEAT BUT THERE IS NOTHING ON THE MECHANICAL DRAWING | | | ABOUT THIS. THE LOAD CALCULATIONS SHOW 11979 BTUH BUT | | | THE MECHANICAL DRAWING SHOWS A 2-TON UNIT. THE LOAD | | | CALCULATIONS SHOW THAT A ZONED SYSTEM MUST BE INSTALLED | | | BECAUSE OF THE LARGE SPIKES IN SOLAR LOAD BUT THE | | | DRAWING SHOWS A 1 ROOM STRUCTURE WITHOUT A ZONED | | | SYSTEM. | | | | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2021-10-18 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-10-18 |
Time |
12:36 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-10-18 |
Time |
12:36 |
Sent To |
|
|
| Notes |
| 2021-10-18 12:36:16 | 2ND REVIEW FBC-2020 MECHANICAL | | | PERMIT-21021430 | | | | | | CODES IN EFFECT: | | | | | | FBC B- FLORIDA BUILDING CODE | | | FBC M- FLORIDA MECHANICAL CODE | | | FBC EC- FLORIDA ENERGY CONSERVATION | | | FBC FG- FLORIDA FUEL GAS | | | FBC EX- FLORIDA EXISTING BUILDING CODE | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) PLEASE PROVIDE THE ENERGY CALCULATIONS FOR THIS NEW | | | STRUCTURE AS REQUESTED IN THE FIRST REVIEW COMMENTS. | | | FBC EC 101.5.1.1.2 | | | | | | 2) PLEASE PROVIDE THE MECHANICAL EQUIPMENT SIZING | | | CALCULATIONS AS REQUESTED IN THE FIRST REVIEW COMMENTS. | | | FBC EC R403.7.1 | | | | | | 3) SHEET M-1 SHOWS A MINI-SPLIT ONLY AND ONLY A FIRST | | | FLOOR. S1-3 INDICATES DUCTWORK FOR THE FIRST AND SECOND | | | FLOOR BUT DOES NOT SHOW THE MECHANICAL SYSTEM. PLEASE | | | PROVIDE MECHANICAL DRAWINGS THAT ARE CONSISTENT AND | | | PROVIDE DETAILS FOR THE MECHANICAL SYSTEM. INCLUDING | | | THE LOCATION OF THE AHU AND THE CONDENSING UNIT ALONG | | | WITH THE ANCHORING DETAILS OF THE CONDENSING UNIT. | | | PLEASE ALSO SHOW THE CONDENSATE PIPING AND TERMINATION | | | LOCATION. FBC 107.2.1 | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM. | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2021-03-25 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-03-25 |
Time |
12:11 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-03-25 |
Time |
11:43 |
Sent To |
|
|
| Notes |
| 2021-03-25 12:11:55 | 1ST REVIEW FBC-2020 MECHANICAL | | | PERMIT-21021430 | | | | | | CODES IN EFFECT: | | | | | | FBC B- FLORIDA BUILDING CODE | | | FBC M- FLORIDA MECHANICAL CODE | | | FBC EC- FLORIDA ENERGY CONSERVATION | | | FBC FG- FLORIDA FUEL GAS | | | FBC EX- FLORIDA EXISTING BUILDING CODE | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) PLEASE PROVIDE A SCOPE OF WORK FOR THE MECHANICAL | | | SYSTEM INSTALLATION. IS THERE GOING TO BE A NEW | | | MECHANICAL SYSTEM INSTALLED OR IS THE MECHANICAL DESIGN | | | USING THE EXISTING SYSTEM TO CONDITION THIS NEW | | | STRUCTURE? FBC 107.2.1 | | | | | | 2) MECHANICAL ENGINEER OR MECHANICAL CONTRACTOR THAT IS | | | CONTRACTED TO INSTALL THE MECHANICAL SYSTEM MUST SUBMIT | | | MECHANICAL EQUIPMENT SIZING CALCULATIONS FOR THIS | | | PROJECT. FBC EC R403.7.1 | | | | | | 3) THE DESIGNER OF THE MECHANICAL DRAWING MUST SHOW THE | | | BATH EXHAUST. FBC RES M1507.4 | | | | | | 4) PLEASE PROVIDE THE ENERGY CALCULATIONS FOR THIS NEW | | | CONSTRUCTION. FBC EC 101.5.1.1.2 | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE OLD | | | SHEETS FROM THE PLAN SETS, BIND THEM TOGETHER | | | SEPARATELY AND MARK VOID OR OLD ON THEM. PLEASE RETAIN | | | THEM FOR REFERENCE WITH THE NEW SUBMITTED PLANS. THIS | | | PROCESS WILL ALSO APPLY TO ANY DOCUMENTS SUCH AS | | | PRODUCT APPROVALS OR CALCULATIONS BEING REPLACED OR | | | UPDATED. | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2021-10-23 |
|
|
Cont ID |
|
| Sent By |
abelisle |
Date |
2021-10-23 |
Time |
10:14 |
Rev Time |
0.00 |
| Received By |
abelisle |
Date |
2021-10-23 |
Time |
09:49 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2021-03-23 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2021-03-23 |
Time |
17:14 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2021-03-23 |
Time |
16:48 |
Sent To |
|
|
| Notes |
| 2021-03-23 17:15:06 | 1ST REVIEW FBC-2020 RES. | | | PERMIT- 21021430 | | | 3/23/2021 | | | | | | CODES IN EFFECT: | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION | | | 2020 | | | FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020 | | | FBC B- FLORIDA BUILDING CODE 7TH EDITION 2020 | | | FBC M- FLORIDA MECHANICAL CODE 7TH EDITION 2020 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION | | | 2020 | | | FBC FG- FLORIDA FUEL GAS CODE 7TH EDITION 2020 | | | FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) PROVIDE PLUMBING PLANS, RISER DRAWINGS, DETAILS AND | | | SPECIFICATIONS- SECTION 107.2.1 & 107.3.5.3 WPB. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
N |
Date |
2021-04-02 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-04-02 |
Time |
09:18 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-04-02 |
Time |
07:02 |
Sent To |
|
|
| Notes |
| 2021-04-02 09:21:25 | PROVISO ON SHEET S 1-2: SEPERATE ROOFING PERMIT | | | REQUIRED. CT |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
4 |
Status |
F |
Date |
2022-11-01 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2022-11-01 |
Time |
14:59 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2022-11-01 |
Time |
14:59 |
Sent To |
|
|
| Notes |
| 2022-11-01 15:01:02 | SIGNATURE REVIEW FAILED | | | | | | PLAN SUBMITTED M-1 DOES NOT DETAIL THE REQUIRED , | | | VERIFIABLE DIGITAL SIGNATURE AND SEAL. | | | | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. | | | | | | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2020 7TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE 2020 7TH ED. | | | FBC EB = FLORIDA BUILDING CODE EXISTING BUILDING 2020 | | | 7TH EDITION | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 | | | 7TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2020 7TH EDITION | | | NEC = NFPA 70 2017 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | V/R, | | | | | | MICHAEL PETERSON | | | ELECTRICAL PLANS EXAMINER | | | [email protected] | | | 561-805-6746 | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
F |
Date |
2022-04-15 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-04-15 |
Time |
09:42 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-04-14 |
Time |
17:12 |
Sent To |
|
|
| Notes |
| 2022-04-15 09:44:02 | SIGNATURE REVIEW | | | | | | CHRISTOPHER S. THROOP, C.B.O., CFM | | | PLANS EXAMINER II PX3169/SFP306 | | | INSPECTOR BN4338 | | | BUILDING OFFICIAL BU1635 | | | ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935 | | | DEVELOPMENT SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | (561) 805-6726 | | | [email protected] | | | | | | CODES IN EFFECT: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | NEC2017 | | | | | | 3RD REVIEW | | | RESULTS: DENIED | | | | | | NOTICE: COMMENTS FROM 2ND SIGNATURE REVIEW HAVE NOT | | | BEEN ADDRESSED. SEE BELOW: | | | | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | RE: STRUCTURAL PLAN PAGE S-1. | | | | | | FLORIDA PROFESSIONAL ENGINEERS MAY NOT SELF CERTIFY | | | DIGITAL SIGNATURES AND SEALS PER FS 668.003. | | | | | | THE DESIGNER OF THE STRUCTURAL SHEETS CANNOT | | | SELF-CERTIFY THEIR DIGITAL SIGNATURE. THE SIGNATURE | | | MUST BE THIRD PARTY VERIFIED. | | | 61G15-23.004 F.A.C. | | | (2) A PROFESSIONAL ENGINEER UTILIZING A DIGITAL | | | SIGNATURE TO ELECTRONICALLY SIGN AND SEAL ENGINEERING | | | PLANS, SPECIFICATIONS, REPORTS OR OTHER DOCUMENTS SHALL | | | HAVE THEIR IDENTITY AUTHENTICATED BY A CERTIFICATION | | | AUTHORITY AND SHALL ASSURE THAT THE DIGITAL SIGNATURE | | | IS: (A) UNIQUE TO THE PERSON USING IT; (B) CAPABLE OF | | | VERIFICATION; AS OF NOVEMBER 16, 2020 63 (C) UNDER THE | | | SOLE CONTROL OF THE PERSON USING IT; AND, (D) LINKED TO | | | A DOCUMENT IN SUCH A MANNER THAT THE DIGITAL SIGNATURE | | | AND CORRESPONDINGLY THE DOCUMENT IS INVALIDATED IF ANY | | | DATA IN THE DOCUMENT IS CHANGED. | | | | | | | | | 1. DOCUMENTS PREPARED BY AN ARCHITECT OR ENGINEER AND | | | SUBMITTED FOR PUBLIC RECORD ARE TO BE SIGNED, SEALED, | | | DATED ORIGINALS. A SCAN OF A WET SEAL AND SIGNATURE OR | | | DIGITAL SIGNATURE IS NOT CONSIDERED A DIGITAL | | | SIGNATURE. | | | | | | 2. EITHER UPLOAD A VALID DIGITALLY SIGNED DOCUMENT OR | | | DROP OFF (OR MAIL) ONE PAPER ORIGINAL WITH AN ORIGINAL | | | WET SEAL AND SIGNATURE TO: | | | | | | BUILDING DIVISION, FIRST FLOOR | | | CITY OF WEST PALM BEACH | | | 401 CLEMATIS ST | | | WEST PALM BEACH, FL 33401 | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
F |
Date |
2021-12-06 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-12-06 |
Time |
11:05 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-12-06 |
Time |
07:45 |
Sent To |
|
|
| Notes |
| 2021-12-06 11:07:36 | SIGNATURE REVIEW | | | | | | CHRISTOPHER S. THROOP, C.B.O., CFM | | | PLANS EXAMINER II PX3169/SFP306 | | | INSPECTOR BN4338 | | | BUILDING OFFICIAL BU1635 | | | ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935 | | | DEVELOPMENT SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | (561) 805-6726 | | | [email protected] | | | | | | CODES IN EFFECT: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | NEC2017 | | | | | | 2ND REVIEW | | | RESULTS: DENIED | | | | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | RE: STRUCTURAL PLAN PAGE S-1. | | | | | | FLORIDA PROFESSIONAL ENGINEERS MAY NOT SELF CERTIFY | | | DIGITAL SIGNATURES AND SEALS PER FS 668.003. | | | | | | THE DESIGNER OF THE STRUCTURAL SHEETS CANNOT | | | SELF-CERTIFY THEIR DIGITAL SIGNATURE. THE SIGNATURE | | | MUST BE THIRD PARTY VERIFIED. | | | 61G15-23.004 F.A.C. | | | (2) A PROFESSIONAL ENGINEER UTILIZING A DIGITAL | | | SIGNATURE TO ELECTRONICALLY SIGN AND SEAL ENGINEERING | | | PLANS, SPECIFICATIONS, REPORTS OR OTHER DOCUMENTS SHALL | | | HAVE THEIR IDENTITY AUTHENTICATED BY A CERTIFICATION | | | AUTHORITY AND SHALL ASSURE THAT THE DIGITAL SIGNATURE | | | IS: (A) UNIQUE TO THE PERSON USING IT; (B) CAPABLE OF | | | VERIFICATION; AS OF NOVEMBER 16, 2020 63 (C) UNDER THE | | | SOLE CONTROL OF THE PERSON USING IT; AND, (D) LINKED TO | | | A DOCUMENT IN SUCH A MANNER THAT THE DIGITAL SIGNATURE | | | AND CORRESPONDINGLY THE DOCUMENT IS INVALIDATED IF ANY | | | DATA IN THE DOCUMENT IS CHANGED. | | | | | | | | | 1. DOCUMENTS PREPARED BY AN ARCHITECT OR ENGINEER AND | | | SUBMITTED FOR PUBLIC RECORD ARE TO BE SIGNED, SEALED, | | | DATED ORIGINALS. A SCAN OF A WET SEAL AND SIGNATURE OR | | | DIGITAL SIGNATURE IS NOT CONSIDERED A DIGITAL | | | SIGNATURE. | | | | | | 2. EITHER UPLOAD A VALID DIGITALLY SIGNED DOCUMENT OR | | | DROP OFF (OR MAIL) ONE PAPER ORIGINAL WITH AN ORIGINAL | | | WET SEAL AND SIGNATURE TO: | | | | | | BUILDING DIVISION, FIRST FLOOR | | | CITY OF WEST PALM BEACH | | | 401 CLEMATIS ST | | | WEST PALM BEACH, FL 33401 | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2021-03-25 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-03-25 |
Time |
12:13 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-03-25 |
Time |
12:13 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
4 |
Status |
F |
Date |
2022-10-26 |
|
|
Cont ID |
|
| Sent By |
llouie |
Date |
2022-10-26 |
Time |
|
Rev Time |
0.00 |
| Received By |
llouie |
Date |
2022-10-26 |
Time |
|
Sent To |
|
|
| Notes |
| 2022-10-26 09:24:43 | ** FAILED ** | | | | | | PLEASE ADDRESS THE FOLLOWING COMMENTS. RESPOND TO THE | | | COMMENTS IN WRITING AND/OR ON THE PLANS WHERE | | | APPLICABLE. PLEASE NOTE THAT ZONING'S COMMENTS FROM THE | | | 10/22/2021 AND 2/15/2022 REVIEWS HAVE NOT BEEN | | | ADDRESSED: | | | | | | 1.) THE DESCRIPTION PROVIDED IN THE APPLICATION'S SCOPE | | | OF WORK IS AN 800 SQ. FT. COTTAGE; HOWEVER, THE PLANS | | | ARE INCONSISTENT WITH THIS SCOPE (I.E. THE PROPOSED | | | BUILDING SIZE IS 1,875 SQ. FT. AS SPECIFIED IN THE | | | PLAN, IT ALSO SPECIFIES THE USE OF SPACE AS A NEW UNIT, | | | WHICH IS NOT PERMITTED.). | | | | | | [3/12/2021, 10/22/2021 AND 2/15/2022 REPEAT COMMENT: | | | THE REVISED PERMIT PLANS INDICATE THAT THE SCOPE OF | | | WORK IS FOR A NEW STRUCTURE. A SITE PLAN, SHOWING THE | | | SETBACK DISTANCE OF THE PROPOSED NEW STRUCTURE SHALL BE | | | PROVIDED FOR REVIEW BY ZONING STAFF.] | | | | | | | | | 2.) PER ZONING AND LAND DEVELOPMENT REGULATIONS (ZLDR) | | | S.94-71, THE PROPERTY MUST HAVE A MINIMUM LOT WIDTH OF | | | 60 FT. FOR AN ACCESSORY DWELLING UNIT. ACCORDING TO THE | | | PROVIDED SURVEY, THE LOT WIDTH OF THE PROPERTY IS ONLY | | | 50 FT. WIDE, WHICH DOES NOT ALLOW FOR AN ADDITIONAL | | | UNIT. | | | | | | [3/12/2021, 10/22/2021 AND 2/15/2022 REPEAT COMMENT: IT | | | MUST BE CLEARLY NOTED IN THE PLAN THAT AN ACCESSORY | | | DWELLING UNIT IS PROHIBITED AND THAT THE PROPOSED SCOPE | | | OF WORK IF FOR A UTILITY ROOM ONLY.] | | | | | | | | | 3.) PER ZLDR S.94-304(B), THE SIZE OF THE ACCESSORY | | | STRUCTURE SHALL NOT EXCEED 75% OF THE GROSS FLOOR AREA | | | OF THE PRIMARY STRUCTURE WITH A MAXIMUM FLOOR AREA OF | | | 1,000 SQ. FT. INFORMATION PROVIDED IN THE PLANS | | | INDICATE THAT THE PROPOSED BUILDING SIZE HAS BEEN | | | EXCEEDED AND DOES NOT MEET ZONING CODE. | | | | | | [3/12/2021, 10/22/2021 AND 2/15/2022 REPEAT COMMENT: | | | PLANS ARE INCONSISTENT (I.E. SOME PLANS SHOWS ONLY 1 | | | FLOOR; OTHER PLANS SHOWS TWO FLOORS; TWO LEVELS WOULD | | | EXCEED THE MAXIMUM ALLOWABLE AREA FOR AN ACCESSORY | | | UTILITY ROOM AS SPECIFIED IN THE PLANS); PLANS MUST | | | MATCH FOR CONSISTENCY.] | | | | | | | | | 4.) PROVIDE A SITE PLAN OF THE PROPERTY THAT | | | ILLUSTRATES THE EXACT LOCATION OF THE PROPOSED NEW | | | STRUCTURE AND DISTANCE DIMENSIONS FROM THE PROPERTY | | | LINES. ALL ACCESSORY STRUCTURES MUST CONFORM TO THE | | | MINIMUM BUILDING SETBACKS PROVIDED IN ZLDR S.94-304(B). | | | | | | [3/12/2021, 10/22/2021 AND 2/15/2022 REPEAT COMMENT: | | | NOT ADDRESSED. NO SITE PLAN PROVIDED IN THE PERMIT | | | RESUBMITTAL.] | | | | | | | | | 5.) PLEASE DIMENSION OUT THE HEIGHT OF THE PROPOSED | | | STRUCTURE IN THE ARCHITECTURAL DRAWINGS. THE HEIGHT OF | | | THE ACCESSORY STRUCTURE SHALL NOT EXCEED 25 FT. [ZLDR | | | S.94-304(B)(4)] | | | | | | [3/12/2021,10/22/2021 AND 2/15/2022 REPEAT COMMENT: IT | | | IS NOT CLEAR IF THE PROPOSED STRUCTURE IS ONE OR TWO | | | STORIES; IF THE SCOPE OF WORK HAS BEEN CHANGED TO A | | | 1-STORY BUILDING, THE HEIGHT WOULD NEED TO BE ADJUSTED | | | TO REFLECT CHANGES.] | | | | | | | | | 6.) ARCHITECTURAL DRAWINGS DO NOT MATCH THE FLOOR PLANS | | | FOR THE PROPOSED STRUCTURE. PLEASE ADDRESS FOR | | | CONSISTENCY. [ZLDR S.94-304(B)(4)] | | | | | | [3/12/2021, 10/22/2021 AND 2/15/2022 REPEAT COMMENT: IT | | | IS NOT CLEAR IF THE PROPOSED STRUCTURE IS ONE OR TWO | | | STORIES; IF THE SCOPE OF WORK HAS BEEN CHANGED TO A | | | 1-STORY BUILDING, THE ELEVATIONAL DRAWING WOULD NEED TO | | | BE ADJUSTED TO REFLECT CHANGES.] | | | | | | | | | 7.) A NOTE SHALL BE PROVIDED IN THE PLANS THAT STATE | | | THAT THE USE OF THE SPACE SHALL NOT BE UTILIZED AS AN | | | ACCESSORY DWELLING UNIT) FOR COMPLIANCE WITH THE ZONING | | | REGULATIONS OF THE CITY OF WEST PALM BEACH. | | | | | | [3/12/2021, 10/22/2021 AND 2/15/2022 REPEAT COMMENT: | | | NOT ADDRESSED. THE REQUESTED NOTE WAS NOT DETECTED IN | | | THE REVISED PERMIT PLANS.] | | | | | | | | | | | | NOTES: | | | | | | * ANY REVISIONS MAY RESULT IN ADDITIONAL COMMENTS. | | | | | | * CONTACT LINDA LOUIE @ (561) 822-1458 IF THERE ARE | | | QUESTIONS. | | | | | | * ZONE: SF14 (EXISTING 50 FT. WIDE LOT - DOES NOT MEET | | | THE MINIMUM LOT SIZE REQUIREMENTS FOR AN ADU) | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
F |
Date |
2022-02-15 |
|
|
Cont ID |
|
| Sent By |
llouie |
Date |
2022-02-15 |
Time |
|
Rev Time |
0.00 |
| Received By |
llouie |
Date |
2022-02-15 |
Time |
|
Sent To |
|
|
| Notes |
| 2022-02-15 16:15:02 | ** FAILED ** | | | | | | PLEASE ADDRESS THE FOLLOWING COMMENTS. RESPOND TO THE | | | COMMENTS IN WRITING AND/OR ON THE PLANS WHERE | | | APPLICABLE. PLEASE NOTE THAT ZONING'S COMMENTS FROM THE | | | 10/22/2021 REVIEW HAVE NOT BEEN ADDRESSED: | | | | | | 1.) THE DESCRIPTION PROVIDED IN THE APPLICATION'S SCOPE | | | OF WORK IS AN 800 SQ. FT. COTTAGE; HOWEVER, THE PLANS | | | ARE INCONSISTENT WITH THIS SCOPE (I.E. THE PROPOSED | | | BUILDING SIZE IS 1,875 SQ. FT. AS SPECIFIED IN THE | | | PLAN, IT ALSO SPECIFIES THE USE OF SPACE AS A NEW UNIT, | | | WHICH IS NOT PERMITTED.). | | | | | | [3/12/2021 AND 10/22/2021 REPEAT COMMENT: THE REVISED | | | PERMIT PLANS INDICATE THAT THE SCOPE OF WORK IS FOR A | | | NEW STRUCTURE. A SITE PLAN, SHOWING THE SETBACK | | | DISTANCE OF THE PROPOSED NEW STRUCTURE SHALL BE | | | PROVIDED FOR REVIEW BY ZONING STAFF.] | | | | | | | | | 2.) PER ZONING AND LAND DEVELOPMENT REGULATIONS (ZLDR) | | | S.94-71, THE PROPERTY MUST HAVE A MINIMUM LOT WIDTH OF | | | 60 FT. FOR AN ACCESSORY DWELLING UNIT. ACCORDING TO THE | | | PROVIDED SURVEY, THE LOT WIDTH OF THE PROPERTY IS ONLY | | | 50 FT. WIDE, WHICH DOES NOT ALLOW FOR AN ADDITIONAL | | | UNIT. | | | | | | [3/12/2021 AND 10/22/2021 REPEAT COMMENT: IT MUST BE | | | CLEARLY NOTED IN THE PLAN THAT AN ACCESSORY DWELLING | | | UNIT IS PROHIBITED AND THAT THE PROPOSED SCOPE OF WORK | | | IF FOR A UTILITY ROOM ONLY.] | | | | | | | | | 3.) PER ZLDR S.94-304(B), THE SIZE OF THE ACCESSORY | | | STRUCTURE SHALL NOT EXCEED 75% OF THE GROSS FLOOR AREA | | | OF THE PRIMARY STRUCTURE WITH A MAXIMUM FLOOR AREA OF | | | 1,000 SQ. FT. INFORMATION PROVIDED IN THE PLANS | | | INDICATE THAT THE PROPOSED BUILDING SIZE HAS BEEN | | | EXCEEDED AND DOES NOT MEET ZONING CODE. | | | | | | [3/12/2021 AND 10/22/2021 REPEAT COMMENT: PLANS ARE | | | INCONSISTENT (I.E. SOME PLANS SHOWS ONLY 1 FLOOR; OTHER | | | PLANS SHOWS TWO FLOORS; TWO LEVELS WOULD EXCEED THE | | | MAXIMUM ALLOWABLE AREA FOR AN ACCESSORY UTILITY ROOM AS | | | SPECIFIED IN THE PLANS); PLANS MUST MATCH FOR | | | CONSISTENCY.] | | | | | | | | | 4.) PROVIDE A SITE PLAN OF THE PROPERTY THAT | | | ILLUSTRATES THE EXACT LOCATION OF THE PROPOSED NEW | | | STRUCTURE AND DISTANCE DIMENSIONS FROM THE PROPERTY | | | LINES. ALL ACCESSORY STRUCTURES MUST CONFORM TO THE | | | MINIMUM BUILDING SETBACKS PROVIDED IN ZLDR S.94-304(B). | | | | | | [3/12/2021 AND 10/22/2021 REPEAT COMMENT: NOT | | | ADDRESSED. NO SITE PLAN PROVIDED IN THE PERMIT | | | RESUBMITTAL.] | | | | | | | | | 5.) PLEASE DIMENSION OUT THE HEIGHT OF THE PROPOSED | | | STRUCTURE IN THE ARCHITECTURAL DRAWINGS. THE HEIGHT OF | | | THE ACCESSORY STRUCTURE SHALL NOT EXCEED 25 FT. [ZLDR | | | S.94-304(B)(4)] | | | | | | [3/12/2021 AND 10/22/2021 REPEAT COMMENT: IT IS NOT | | | CLEAR IF THE PROPOSED STRUCTURE IS ONE OR TWO STORIES; | | | IF THE SCOPE OF WORK HAS BEEN CHANGED TO A 1-STORY | | | BUILDING, THE HEIGHT WOULD NEED TO BE ADJUSTED TO | | | REFLECT CHANGES.] | | | | | | | | | 6.) ARCHITECTURAL DRAWINGS DO NOT MATCH THE FLOOR PLANS | | | FOR THE PROPOSED STRUCTURE. PLEASE ADDRESS FOR | | | CONSISTENCY. | | | | | | [ZLDR S.94-304(B)(4)] [3/12/2021 AND 10/22/2021 REPEAT | | | COMMENT: IT IS NOT CLEAR IF THE PROPOSED STRUCTURE IS | | | ONE OR TWO STORIES; IF THE SCOPE OF WORK HAS BEEN | | | CHANGED TO A 1-STORY BUILDING, THE ELEVATIONAL DRAWING | | | WOULD NEED TO BE ADJUSTED TO REFLECT CHANGES.] | | | | | | | | | 7.) A NOTE SHALL BE PROVIDED IN THE PLANS THAT STATE | | | THAT THE USE OF THE SPACE SHALL NOT BE UTILIZED AS AN | | | ACCESSORY DWELLING UNIT) FOR COMPLIANCE WITH THE ZONING | | | REGULATIONS OF THE CITY OF WEST PALM BEACH. | | | | | | [3/12/2021 AND 10/22/2021 REPEAT COMMENT: NOT | | | ADDRESSED. THE REQUESTED NOTE WAS NOT DETECTED IN THE | | | REVISED PERMIT PLANS.] | | | | | | | | | | | | NOTES: | | | | | | * ANY REVISIONS MAY RESULT IN ADDITIONAL COMMENTS. | | | | | | * CONTACT LINDA LOUIE @ (561) 822-1458 IF THERE ARE | | | QUESTIONS. | | | | | | * ZONE: SF14 (EXISTING 50 FT. WIDE LOT - DOES NOT MEET | | | THE MINIMUM LOT SIZE REQUIREMENTS FOR AN ADU) | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2021-10-22 |
|
|
Cont ID |
|
| Sent By |
llouie |
Date |
2021-10-22 |
Time |
|
Rev Time |
0.00 |
| Received By |
llouie |
Date |
2021-10-22 |
Time |
|
Sent To |
|
|
| Notes |
| 2021-10-22 13:50:15 | ** FAILED ** | | | | | | PLEASE ADDRESS THE FOLLOWING COMMENTS. RESPOND TO THE | | | COMMENTS IN WRITING AND/OR ON THE PLANS WHERE | | | APPLICABLE: | | | | | | 1.) THE DESCRIPTION PROVIDED IN THE APPLICATION'S SCOPE | | | OF WORK IS AN 800 SQ. FT. COTTAGE; HOWEVER, THE PLANS | | | ARE INCONSISTENT WITH THIS SCOPE (I.E. THE PROPOSED | | | BUILDING SIZE IS 1,875 SQ. FT. AS SPECIFIED IN THE | | | PLAN, IT ALSO SPECIFIES THE USE OF SPACE AS A NEW UNIT, | | | WHICH IS NOT PERMITTED.). [3/12/2021: THE REVISED | | | PERMIT PLANS INDICATE THAT THE SCOPE OF WORK IS FOR A | | | NEW STRUCTURE. A SITE PLAN, SHOWING THE SETBACK | | | DISTANCE OF THE PROPOSED NEW STRUCTURE SHALL BE | | | PROVIDED FOR REVIEW BY ZONING STAFF.] | | | | | | | | | 2.) PER ZONING AND LAND DEVELOPMENT REGULATIONS (ZLDR) | | | S.94-71, THE PROPERTY MUST HAVE A MINIMUM LOT WIDTH OF | | | 60 FT. FOR AN ACCESSORY DWELLING UNIT. ACCORDING TO THE | | | PROVIDED SURVEY, THE LOT WIDTH OF THE PROPERTY IS ONLY | | | 50 FT. WIDE, WHICH DOES NOT ALLOW FOR AN ADDITIONAL | | | UNIT. [3/12/2021 REPEAT COMMENT: IT MUST BE CLEARLY | | | NOTED IN THE PLAN THAT AN ACCESSORY DWELLING UNIT IS | | | PROHIBITED AND THAT THE PROPOSED SCOPE OF WORK IF FOR A | | | UTILITY ROOM ONLY.] | | | | | | | | | 3.) PER ZLDR S.94-304(B), THE SIZE OF THE ACCESSORY | | | STRUCTURE SHALL NOT EXCEED 75% OF THE GROSS FLOOR AREA | | | OF THE PRIMARY STRUCTURE WITH A MAXIMUM FLOOR AREA OF | | | 1,000 SQ. FT. INFORMATION PROVIDED IN THE PLANS | | | INDICATE THAT THE PROPOSED BUILDING SIZE HAS BEEN | | | EXCEEDED AND DOES NOT MEET ZONING CODE. [3/12/2021 | | | REPEAT COMMENT: PLANS ARE INCONSISTENT (I.E. SOME PLANS | | | SHOWS ONLY 1 FLOOR; OTHER PLANS SHOWS TWO FLOORS; TWO | | | LEVELS WOULD EXCEED THE MAXIMUM ALLOWABLE AREA FOR AN | | | ACCESSORY UTILITY ROOM AS SPECIFIED IN THE PLANS); | | | PLANS MUST MATCH FOR CONSISTENCY.] | | | | | | | | | 4.) PROVIDE A SITE PLAN OF THE PROPERTY THAT | | | ILLUSTRATES THE EXACT LOCATION OF THE PROPOSED NEW | | | STRUCTURE AND DISTANCE DIMENSIONS FROM THE PROPERTY | | | LINES. ALL ACCESSORY STRUCTURES MUST CONFORM TO THE | | | MINIMUM BUILDING SETBACKS PROVIDED IN ZLDR S.94-304(B). | | | [3/12/2021 REPEAT COMMENT: NOT ADDRESSED. NO SITE PLAN | | | PROVIDED IN THE PERMIT RESUBMITTAL.] | | | | | | | | | 5.) PLEASE DIMENSION OUT THE HEIGHT OF THE PROPOSED | | | STRUCTURE IN THE ARCHITECTURAL DRAWINGS. THE HEIGHT OF | | | THE ACCESSORY STRUCTURE SHALL NOT EXCEED 25 FT. [ZLDR | | | S.94-304(B)(4)] [3/12/2021 REPEAT COMMENT: IT IS NOT | | | CLEAR IF THE PROPOSED STRUCTURE IS ONE OR TWO STORIES; | | | IF THE SCOPE OF WORK HAS BEEN CHANGED TO A 1-STORY | | | BUILDING, THE HEIGHT WOULD NEED TO BE ADJUSTED TO | | | REFLECT CHANGES.] | | | | | | | | | 6.) ARCHITECTURAL DRAWINGS DO NOT MATCH THE FLOOR PLANS | | | FOR THE PROPOSED STRUCTURE. PLEASE ADDRESS FOR | | | CONSISTENCY. [ZLDR S.94-304(B)(4)] [3/12/2021 REPEAT | | | COMMENT: IT IS NOT CLEAR IF THE PROPOSED STRUCTURE IS | | | ONE OR TWO STORIES; IF THE SCOPE OF WORK HAS BEEN | | | CHANGED TO A 1-STORY BUILDING, THE ELEVATIONAL DRAWING | | | WOULD NEED TO BE ADJUSTED TO REFLECT CHANGES.] | | | | | | | | | 7.) A NOTE SHALL BE PROVIDED IN THE PLANS THAT STATE | | | THAT THE USE OF THE SPACE SHALL NOT BE UTILIZED AS AN | | | ACCESSORY DWELLING UNIT) FOR COMPLIANCE WITH THE ZONING | | | REGULATIONS OF THE CITY OF WEST PALM BEACH. [3/12/2021: | | | NOT ADDRESSED. THE REQUESTED NOTE WAS NOT DETECTED IN | | | THE REVISED PERMIT PLANS.] | | | | | | | | | NOTES: | | | | | | * ANY REVISIONS MAY RESULT IN ADDITIONAL COMMENTS. | | | | | | * CONTACT LINDA LOUIE @ (561) 822-1458 IF THERE ARE | | | QUESTIONS. | | | | | | * ZONE: SF14 (EXISTING 50 FT. WIDE LOT - DOES NOT MEET | | | THE MINIMUM LOT SIZE REQUIREMENTS FOR AN ADU) | | | | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2021-03-12 |
|
|
Cont ID |
|
| Sent By |
llouie |
Date |
2021-03-12 |
Time |
|
Rev Time |
|
| Received By |
llouie |
Date |
2021-03-12 |
Time |
|
Sent To |
|
|
| Notes |
| 2021-03-12 10:21:52 | ** FAILED ** | | | | | | PLEASE ADDRESS THE FOLLOWING COMMENTS. RESPOND TO THE | | | COMMENTS IN WRITING AND/OR ON THE PLANS WHERE | | | APPLICABLE: | | | | | | 1.) THE DESCRIPTION PROVIDED IN THE APPLICATION'S SCOPE | | | OF WORK IS AN 800 SQ. FT. COTTAGE; HOWEVER, THE PLANS | | | ARE INCONSISTENT WITH THIS SCOPE (I.E. THE PROPOSED | | | BUILDING SIZE IS 1,875 SQ. FT. AS SPECIFIED IN THE | | | PLAN, IT ALSO SPECIFIES THE USE OF SPACE AS A NEW UNIT, | | | WHICH IS NOT PERMITTED.). PLEASE CLARIFY. | | | | | | 2.) PER ZONING AND LAND DEVELOPMENT REGULATIONS (ZLDR) | | | S.94-71, THE PROPERTY MUST HAVE A MINIMUM LOT WIDTH OF | | | 60 FT. FOR AN ACCESSORY DWELLING UNIT. ACCORDING TO THE | | | PROVIDED SURVEY, THE LOT WIDTH OF THE PROPERTY IS ONLY | | | 50 FT. WIDE, WHICH DOES NOT ALLOW FOR AN ADDITIONAL | | | UNIT. | | | | | | 3.) PER ZLDR S.94-304(B), THE SIZE OF THE ACCESSORY | | | STRUCTURE SHALL NOT EXCEED 75% OF THE GROSS FLOOR AREA | | | OF THE PRIMARY STRUCTURE WITH A MAXIMUM FLOOR AREA OF | | | 1,000 SQ. FT. INFORMATION PROVIDED IN THE PLANS | | | INDICATE THAT THE PROPOSED BUILDING SIZE HAS BEEN | | | EXCEEDED AND DOES NOT MEET ZONING CODE. | | | | | | 4.) PROVIDE A SITE PLAN OF THE PROPERTY THAT | | | ILLUSTRATES THE EXACT LOCATION OF THE PROPOSED NEW | | | STRUCTURE AND DISTANCE DIMENSIONS FROM THE PROPERTY | | | LINES. ALL ACCESSORY STRUCTURES MUST CONFORM TO THE | | | MINIMUM BUILDING SETBACKS PROVIDED IN ZLDR S.94-304(B). | | | | | | 5.) PLEASE DIMENSION OUT THE HEIGHT OF THE PROPOSED | | | STRUCTURE IN THE ARCHITECTURAL DRAWINGS. THE HEIGHT OF | | | THE ACCESSORY STRUCTURE SHALL NOT EXCEED 25 FT. [ZLDR | | | S.94-304(B)(4)] | | | | | | 6.) ARCHITECTURAL DRAWINGS DO NOT MATCH THE FLOOR PLANS | | | FOR THE PROPOSED STRUCTURE. PLEASE ADDRESS FOR | | | CONSISTENCY. | | | | | | 7.) A NOTE SHALL BE PROVIDED IN THE PLANS THAT STATE | | | THAT THE USE OF THE SPACE SHALL NOT BE UTILIZED AS AN | | | ACCESSORY DWELLING UNIT) FOR COMPLIANCE WITH THE ZONING | | | REGULATIONS OF THE CITY OF WEST PALM BEACH. | | | | | | | | | | | | NOTES: | | | | | | * ANY REVISIONS MAY RESULT IN ADDITIONAL COMMENTS. | | | | | | * CONTACT LINDA LOUIE @ (561) 822-1458 IF THERE ARE | | | QUESTIONS. | | | | | | * ZONE: SF14 (EXISTING 50 FT. WIDE LOT - DOES NOT MEET | | | THE MINIMUM LOT SIZE REQUIREMENTS FOR AN ADU) | | | |
|
|