Plan Review Details - Permit 21021394
| Plan Review Stops For Permit 21021394 |
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2022-01-13 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2022-01-13 |
Time |
08:52 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2022-01-13 |
Time |
08:47 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2021-03-26 |
|
|
Cont ID |
|
| Sent By |
equinone |
Date |
2021-03-26 |
Time |
08:35 |
Rev Time |
0.00 |
| Received By |
equinone |
Date |
2021-03-26 |
Time |
08:35 |
Sent To |
|
|
| Notes |
| 2021-03-26 09:16:09 | 1ST REVIEW FBC-2020 ELECTRICAL | | | PERMIT-21021394 | | | | | | CODES IN EFFECT: | | | | | | FBC B- FLORIDA BUILDING CODE | | | FBC M- FLORIDA MECHANICAL CODE | | | FBC EC- FLORIDA ENERGY CONSERVATION | | | FBC FG- FLORIDA FUEL GAS | | | FBC EX- FLORIDA EXISTING BUILDING CODE | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) PLEASE PROVIDE READABLE DRAWINGS INCLUDING LOCATION | | | OF EQUIPMENT, DISCONNECTS, AND CONDUCTOR AND BREAKER | | | SIZES FOR UNITS TO BE REPLACED. FBC 107.2.1 | | | | | | 2) PLEASE PROVIDE THE "LIKE FOR LIKE" CHANGEOUT FORMS | | | FOR EACH UNIT BEING CHANGED OUT. INCLUDE ELECTRICAL | | | INFORMATION. FBC 107.2 | | | | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE OLD | | | SHEETS FROM THE PLAN SETS, BIND THEM TOGETHER | | | SEPARATELY AND MARK VOID OR OLD ON THEM. PLEASE RETAIN | | | THEM FOR REFERENCE WITH THE NEW SUBMITTED PLANS. THIS | | | PROCESS WILL ALSO APPLY TO ANY DOCUMENTS SUCH AS | | | PRODUCT APPROVALS OR CALCULATIONS BEING REPLACED OR | | | UPDATED. | | | | | | ENRIQUE QUINONEZ P.E. | | | ELECTRICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2022-01-13 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2022-01-13 |
Time |
08:52 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2021-12-20 |
Time |
07:43 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2021-03-26 |
|
|
Cont ID |
|
| Sent By |
equinone |
Date |
2021-03-26 |
Time |
09:16 |
Rev Time |
0.00 |
| Received By |
equinone |
Date |
2021-03-16 |
Time |
09:20 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2021-12-21 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-12-21 |
Time |
06:49 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-12-21 |
Time |
06:49 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2021-03-25 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-03-25 |
Time |
14:52 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-03-25 |
Time |
14:39 |
Sent To |
|
|
| Notes |
| 2021-03-25 14:52:59 | 1ST REVIEW FBC-2020 MECHANICAL | | | PERMIT-21021394 | | | | | | CODES IN EFFECT: | | | | | | FBC B- FLORIDA BUILDING CODE | | | FBC M- FLORIDA MECHANICAL CODE | | | FBC EC- FLORIDA ENERGY CONSERVATION | | | FBC FG- FLORIDA FUEL GAS | | | FBC EX- FLORIDA EXISTING BUILDING CODE | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) PLEASE PROVIDE A COMPLETE SCOPE OF WORK, HOW MANY | | | UNITS WILL BE CHANGED OUT? FBC 107.2.1 | | | | | | 2) PLEASE PROVIDE THE ?LIKE FOR LIKE? CHANGEOUT FORMS | | | FOR EACH UNIT BEING CHANGED OUT. FBC 107.2.1 | | | | | | 3) THE SHEET A1.3 IS A COPY OF AN ORIGINAL DRAWING AND | | | IS UNREADABLE. PLEASE PROVIDE A READABLE DRAWING. FBC | | | 107.2.1 | | | | | | 4) THE VALUE GIVEN ON THE PERMIT APPLICATION SEEMS TO | | | BE LOW, PLEASE INCLUDE A CONTRACT FOR THIS PROJECT. FBC | | | 107.2.1 | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE OLD | | | SHEETS FROM THE PLAN SETS, BIND THEM TOGETHER | | | SEPARATELY AND MARK VOID OR OLD ON THEM. PLEASE RETAIN | | | THEM FOR REFERENCE WITH THE NEW SUBMITTED PLANS. THIS | | | PROCESS WILL ALSO APPLY TO ANY DOCUMENTS SUCH AS | | | PRODUCT APPROVALS OR CALCULATIONS BEING REPLACED OR | | | UPDATED. | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2021-12-21 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-12-21 |
Time |
06:51 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-12-21 |
Time |
06:51 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2021-03-25 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-03-25 |
Time |
14:53 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-03-25 |
Time |
14:53 |
Sent To |
|
|
| Notes |
|
|
|