| Plan Review Stops For Permit 21021363 |
| Review Stop |
AD |
ADDRESSING |
| Rev No |
2 |
Status |
P |
Date |
2021-03-05 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2021-03-05 |
Time |
14:49 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2021-03-05 |
Time |
14:49 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
AD |
ADDRESSING |
| Rev No |
1 |
Status |
F |
Date |
2021-03-01 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2021-03-01 |
Time |
10:18 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2021-03-01 |
Time |
10:18 |
Sent To |
|
|
| Notes |
| 2021-03-01 10:18:21 | NEED A SITE PLAN OR THE WHOLE PROJECT, ALL THE | | | PROPERTIES NEED TO BE ADDRESSES. PLEASE CONTACT | | | [email protected] TO ESTABLISH ADDRESSES FOR THIS PROJECT |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2021-05-11 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-05-11 |
Time |
13:07 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-05-11 |
Time |
13:06 |
Sent To |
|
|
| Notes |
| 2021-05-11 13:07:26 | PROVISO ON PLAN PAGE A-2LD: PROVIDE A SURVEY, SITE PLAN | | | W/FF ELEVATION, SITE DRAINAGE P. | | | GEOTECHNICAL REPORT ON-FILE. SEE MASTER PERMIT | | | 21021363. CT |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2021-05-08 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-05-08 |
Time |
09:43 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-05-08 |
Time |
09:39 |
Sent To |
|
|
| Notes |
| 2021-05-08 09:45:30 | PROVISO ON PLAN PAGE A-2LD: PROVIDE A SURVEY, SITE PLAN | | | W/FF ELEVATION, SITE DRAINAGE PLAN AND A SOILS REPORT | | | OF PAD CERTIFICATION FOR EACH NEW SFR PERMIT. CT |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2021-04-28 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-04-28 |
Time |
09:09 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-04-27 |
Time |
06:22 |
Sent To |
|
|
| Notes |
| 2021-04-28 09:25:49 | PLAN REVIEW BUILDING | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | PLANS EXAMINER PX3169 1&2 FAMILY SFP306 | | | INSPECTOR BN4338 | | | BUILDING OFFICIAL BU1635 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | CODES IN EFFECT: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | 2017 NEC | | | | | | 2ND REVIEW | | | | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED | | | SATISFACTORILY ARE MARKED AS CORRECTED. | | | PREVIOUS COMMENTS THAT HAVE NOT BEEN ADDRESSED | | | SATISFACTORILY MAY HAVE ADDITIONAL COMMENTS IN | | | PARENTHESES. ANY NEW COMMENT WILL BE LISTED AFTER | | | PREVIOUS COMMENTS. | | | | | | | | | 1. PROVIDE A SURVEY, A SITE PLAN AND SITE DRAINAGE | | | PLAN. | | | | | | FBC R 401.3 (DRAINAGE) | | | FBC 107.2.5 (SITE PLAN) CITY AMENDMENTS | | | | | | PROVIDE A SITE PLAN. DRAINAGE/SURVEY | | | 107.2.5 SITE PLAN. THE CONSTRUCTION DOCUMENTS SUBMITTED | | | WITH THE APPLICATION FOR PERMIT SHALL BE ACCOMPANIED BY | | | A SITE PLAN SHOWING TO SCALE THE SIZE AND LOCATION OF | | | NEW CONSTRUCTION AND EXISTING STRUCTURES ON THE SITE, | | | DISTANCES FROM LOT LINES, THE ESTABLISHED STREET GRADES | | | AND THE PROPOSED FINISHED GRADES, DEPICTING THE | | | PROPOSED LOT DRAINAGE AND, AS APPLICABLE, FLOOD HAZARD | | | AREAS, FLOODWAYS, AND DESIGN FLOOD ELEVATIONS; AND IT | | | SHALL BE DRAWN IN ACCORDANCE WITH AN ACCURATE AND | | | INCLUDED BOUNDARY LINE SURVEY. | | | | | | FBC R401.3 SITE DRAINAGE | | | | | | PROVIDE A SITE DRAINAGE PLAN SHOWING COMPLIANCE WITH | | | FBC R401.3 DRAINAGE. | | | SURFACE DRAINAGE SHALL BE DIVERTED TO A STORM SEWER | | | CONVEYANCE OR OTHER APPROVED POINT OF COLLECTION THAT | | | DOES NOT CREATE A HAZARD. | | | LOTS SHALL BE GRADED TO DRAIN SURFACE WATER AWAY FROM | | | FOUNDATION WALLS. THE GRADE SHALL FALL A MINIMUM OF 6 | | | INCHES WITHIN THE FIRST 10 FEET. | | | | | | ADDITIONAL COMMENTS FOR # 1 ABOVE: | | | 1(A) A SITE DRAINAGE PLAN IS REQUIRED FOR EACH LOT PER | | | 107.2.5 AND R401.3. | | | | | | | | | 2. PROVIDE A SOILS REPORT. | | | | | | ADDITIONAL COMMENTS FOR # 2 ABOVE: | | | 2(A) THE GEOTECHNICAL ENGINEERING REPORT FOR THE ENTIRE | | | SITE WAS PROVIDED FOR REVIEW. | | | 2(B) PROVIDE A COPY OF THE BUILDING PAD CERTIFICATION | | | FOR EACH LOT PER FBC 1803.5.8. | | | 1803.5.8 COMPACTED FILL MATERIAL. | | | WHERE SHALLOW FOUNDATIONS WILL BEAR ON COMPACTED FILL | | | MATERIAL MORE THAN 12 INCHES (305 MM) IN DEPTH, A | | | GEOTECHNICAL INVESTIGATION SHALL BE CONDUCTED AND SHALL | | | INCLUDE ALL OF THE FOLLOWING: | | | 1. 1.SPECIFICATIONS FOR THE PREPARATION OF THE SITE | | | PRIOR TO PLACEMENT OF COMPACTED FILL MATERIAL. | | | 2. 2.SPECIFICATIONS FOR MATERIAL TO BE USED AS | | | COMPACTED FILL. | | | 3. 3.TEST METHODS TO BE USED TO DETERMINE THE MAXIMUM | | | DRY DENSITY AND OPTIMUM MOISTURE CONTENT OF THE | | | MATERIAL TO BE USED AS COMPACTED FILL. | | | 4. 4.MAXIMUM ALLOWABLE THICKNESS OF EACH LIFT OF | | | COMPACTED FILL MATERIAL. | | | 5. 5.FIELD TEST METHOD FOR DETERMINING THE IN-PLACE DRY | | | DENSITY OF THE COMPACTED FILL. | | | 6. 6.MINIMUM ACCEPTABLE IN-PLACE DRY DENSITY EXPRESSED | | | AS A PERCENTAGE OF THE MAXIMUM DRY DENSITY DETERMINED | | | IN ACCORDANCE WITH ITEM 3. | | | 7. 7.NUMBER AND FREQUENCY OF FIELD TESTS REQUIRED TO | | | DETERMINE COMPLIANCE WITH ITEM 6. | | | | | | | | | 3. PROVIDE FINISHED FLOOR ELEVATION. | | | R403.1.7.3 FOUNDATION ELEVATION. | | | ON GRADED SITES, THE TOP OF ANY EXTERIOR FOUNDATION | | | SHALL EXTEND ABOVE THE ELEVATION OF THE STREET GUTTER | | | AT POINT OF DISCHARGE OR THE INLET OF AN APPROVED | | | DRAINAGE DEVICE A MINIMUM OF 12 INCHES (305 MM) PLUS 2 | | | PERCENT. ALTERNATE ELEVATIONS ARE PERMITTED SUBJECT TO | | | THE APPROVAL OF THE BUILDING OFFICIAL, PROVIDED IT CAN | | | BE DEMONSTRATED THAT REQUIRED DRAINAGE TO THE POINT OF | | | DISCHARGE AND AWAY FROM THE STRUCTURE IS PROVIDED AT | | | ALL LOCATIONS ON THE SITE. | | | | | | ADDITIONAL COMMENTS FOR # 3 ABOVE: | | | 3(A) THE OVERALL DRAINAGE PLAN, SHEET 2A, STATES A | | | MINIMUM FINISHED FLOOR ELEVATION OF 21.60 FOR THE SITE. | | | PROVIDE A SITE PLAN AND AN ACCURATE AND INCLUDED | | | BOUNDARY LINE SURVEY STATING THE PROPOSED FINISHED | | | FLOOR ELEVATION FOR EACH LOT PER 107.2.5. AND | | | R403.1.7.3. | | | | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2021-03-18 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-03-18 |
Time |
15:53 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-03-16 |
Time |
13:05 |
Sent To |
|
|
| Notes |
| 2021-03-18 16:10:13 | PLAN REVIEW BUILDING | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | PLANS EXAMINER PX3169 1&2 FAMILY SFP306 | | | INSPECTOR BN4338 | | | BUILDING OFFICIAL BU1635 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | CODES IN EFFECT: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | 2017 NEC | | | | | | 1ST REVIEW | | | | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. PROVIDE A SURVEY, A SITE PLAN AND SITE DRAINAGE | | | PLAN. | | | | | | FBC R 401.3 (DRAINAGE) | | | FBC 107.2.5 (SITE PLAN) CITY AMENDMENTS | | | | | | PROVIDE A SITE PLAN. DRAINAGE/SURVEY | | | 107.2.5 SITE PLAN. THE CONSTRUCTION DOCUMENTS SUBMITTED | | | WITH THE APPLICATION FOR PERMIT SHALL BE ACCOMPANIED BY | | | A SITE PLAN SHOWING TO SCALE THE SIZE AND LOCATION OF | | | NEW CONSTRUCTION AND EXISTING STRUCTURES ON THE SITE, | | | DISTANCES FROM LOT LINES, THE ESTABLISHED STREET GRADES | | | AND THE PROPOSED FINISHED GRADES, DEPICTING THE | | | PROPOSED LOT DRAINAGE AND, AS APPLICABLE, FLOOD HAZARD | | | AREAS, FLOODWAYS, AND DESIGN FLOOD ELEVATIONS; AND IT | | | SHALL BE DRAWN IN ACCORDANCE WITH AN ACCURATE AND | | | INCLUDED BOUNDARY LINE SURVEY. | | | | | | FBC R401.3 SITE DRAINAGE | | | | | | PROVIDE A SITE DRAINAGE PLAN SHOWING COMPLIANCE WITH | | | FBC R401.3 DRAINAGE. | | | SURFACE DRAINAGE SHALL BE DIVERTED TO A STORM SEWER | | | CONVEYANCE OR OTHER APPROVED POINT OF COLLECTION THAT | | | DOES NOT CREATE A HAZARD. | | | LOTS SHALL BE GRADED TO DRAIN SURFACE WATER AWAY FROM | | | FOUNDATION WALLS. THE GRADE SHALL FALL A MINIMUM OF 6 | | | INCHES WITHIN THE FIRST 10 FEET. | | | | | | 2. PROVIDE A SOILS REPORT OR A COPY OF THE BUILDING PAD | | | CERTIFICATION FROM THE PROJECT GEO-TECHNICAL ENGINEER. | | | | | | FBC 1803.1 GENERAL. GEOTECHNICAL INVESTIGATIONS SHALL | | | BE CONDUCTED IN ACCORDANCE WITH SECTION 1803.2 AND | | | REPORTED IN ACCORDANCE WITH SECTION 1803.6. | | | | | | 1803.2 INVESTIGATIONS REQUIRED. | | | GEOTECHNICAL INVESTIGATIONS SHALL BE CONDUCTED IN | | | ACCORDANCE WITH SECTIONS 1803.3 THROUGH 1803.5. | | | EXCEPTION: THE BUILDING OFFICIAL SHALL BE PERMITTED TO | | | WAIVE THE REQUIREMENT FOR A GEOTECHNICAL INVESTIGATION | | | WHERE SATISFACTORY DATA FROM ADJACENT AREAS IS | | | AVAILABLE THAT DEMONSTRATES AN INVESTIGATION IS NOT | | | NECESSARY FOR ANY OF THE CONDITIONS IN SECTIONS | | | 1803.5.1 THROUGH 1803.5.6 AND SECTIONS 1803.5.10 AND | | | 1803.5.11. | | | | | | 3. PROVIDE FINISHED FLOOR ELEVATION. | | | R403.1.7.3 FOUNDATION ELEVATION. | | | ON GRADED SITES, THE TOP OF ANY EXTERIOR FOUNDATION | | | SHALL EXTEND ABOVE THE ELEVATION OF THE STREET GUTTER | | | AT POINT OF DISCHARGE OR THE INLET OF AN APPROVED | | | DRAINAGE DEVICE A MINIMUM OF 12 INCHES (305 MM) PLUS 2 | | | PERCENT. ALTERNATE ELEVATIONS ARE PERMITTED SUBJECT TO | | | THE APPROVAL OF THE BUILDING OFFICIAL, PROVIDED IT CAN | | | BE DEMONSTRATED THAT REQUIRED DRAINAGE TO THE POINT OF | | | DISCHARGE AND AWAY FROM THE STRUCTURE IS PROVIDED AT | | | ALL LOCATIONS ON THE SITE. | | | | | | | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2021-04-19 |
|
|
Cont ID |
|
| Sent By |
equinone |
Date |
2021-04-19 |
Time |
15:10 |
Rev Time |
0.00 |
| Received By |
equinone |
Date |
2021-04-19 |
Time |
15:10 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2021-03-04 |
|
|
Cont ID |
|
| Sent By |
equinone |
Date |
2021-03-04 |
Time |
16:45 |
Rev Time |
0.00 |
| Received By |
equinone |
Date |
2021-03-04 |
Time |
16:45 |
Sent To |
|
|
| Notes |
| 2021-03-04 16:45:59 | CODES IN EFFECT | | | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2020 7TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2020 | | | 7TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 | | | 7TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2020 | | | 7TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2020 7TH EDITION | | | NEC = NFPA 70 2017 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | FAC = FLORIDA ADMINISTRATIVE CODE | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1) SHEET C1 -ELECTRICAL NOTE 20: NEW FBC EC R404 | | | REQUIRES: | | | | | | "NOT LESS THAN 90 PERCENT OF THE LAMPS IN PERMANENTLY | | | INSTALLED LUMINAIRES SHALL HAVE AN EFFICACY OF AT LEAST | | | 45 LUMENS-PER-WATT OR SHALL UTILIZE LAMPS WITH AN | | | EFFICACY OF NOT LESS THAN 65 LUMENS-PER-WATT?. | | | | | | PLEASE CHANGE NOTE AS INDICATED. FBC EC R404.1 | | | | | | 2) GFCI/WP RECEPTACLE IS REQUIRED AT BACK OF DWELLING | | | UNIT 210.52(E)(1) | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | CODES IN EFFECT: | | | | | | IF THE RESUBMITTAL IS NOT PREPARED BY A DESIGN | | | PROFESSIONAL (ARCHITECT OR ENGINEER), AND THE PAGES ARE | | | 11X17 OR SMALLER, YOU MAY RESUBMIT, ALONG WITH A | | | COMPLETED RESUBMITTAL FORM, VIA EMAIL TO | | | [email protected]. THE EMAIL SHOULD INCLUDE THE PERMIT | | | NUMBER AND "RESUBMITTAL" IN THE SUBJECT LINE. THE | | | RESUBMITTAL FORM CAN BE FOUND AT THIS WEBSITE: | | | | | | HTTPS://WWW.WPB.ORG/GOVERNMENT/DEVELOPMENT-SERVICES/FOR | | | MS | | | | | | ENRIQUE QUINONEZ P.E. | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
E-LOWVOLT |
ELECTRICAL LOW VOLTAGE |
| Rev No |
1 |
Status |
P |
Date |
2021-03-18 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-03-18 |
Time |
15:32 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-03-16 |
Time |
13:06 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
4 |
Status |
P |
Date |
2021-05-11 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2021-05-11 |
Time |
10:39 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2021-05-11 |
Time |
10:39 |
Sent To |
|
|
| Notes |
| 2021-05-11 10:39:47 | 05/11/21 REVIEWED FOR CODE COMPLIANCE (GAS) | | | | | | BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE | | | COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN | | | PROFESSIONAL, CONTRACTORS, OR THEIR REPRESENTATIVES | | | FROM THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL, | | | STATE, AND NATIONAL CODES AND STANDARDS IN EFFECT AT | | | THE TIME OF PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK | | | OF EVERY ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM | | | REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES | | | / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO | | | AVOID VOIDING OF THE PERMIT. | | | | | | LUIS A. CRESPO | | | PLUMBING PLAN EXAMINER / INSPECTOR | | | EMAIL: [email protected] OFFICE: 561 805-6720 | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
3 |
Status |
F |
Date |
2021-04-22 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2021-04-22 |
Time |
08:13 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2021-04-22 |
Time |
08:13 |
Sent To |
|
|
| Notes |
| 2021-04-22 08:14:12 | 04/22/21 1ST GAS REVIEW**DENIED** WITH COMMENTS | | | | | | NOTE - A COMPREHENSIVE REVIEW COULD NOT BE DONE AT THIS | | | TIME, AND ADDITIONAL PLAN REVIEW COMMENTS MAY BE | | | GENERATED UPON THE RE-REVIEW OF SUBMITTED CORRECTIONS. | | | | | | 1. PLEASE SUBMIT CALCULATIONS FOR COMBUSTION AIR PER | | | THE 2020 FBC RES. SEC. G2407.1 AND G2439.4 (CLOTHES | | | DRYERS). IF LOUVER WILL BE USED. PLEASE SHOW THE | | | LOCATION AND SIZE OF THE LOUVER(S) ON THE PLANS PER THE | | | WPB AMENDMENTS TO THE FBC SEC. 107.2.1 INFORMATION ON | | | CONSTRUCTION DOCUMENTS. | | | | | | 2. PLEASE SUBMIT MANUFACTURER'S SPECIFICATIONS FOR THE | | | PRESSURE REGULATORS. REGULATORS INSTALLED ON THE | | | BUILDING'S EXTERIOR SHALL BE APPROVED FOR OUTDOOR | | | INSTALLATION PER THE 2020 FBC RES. SEC. G2421.1. | | | | | | 3. PLEASE SHOW THE CORRESPONDING EHD NUMBER OF THE | | | CORRUGATED STAINLESS-STEEL TUBING (IF APPLICABLE) FOR | | | EACH PIPE SIZE PER THE WPB AMENDMENTS TO THE FBC | | | SEC.107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. | | | | | | 4. PLEASE SUBMIT MANUFACTURER'S SPECIFICATION | | | SHEETS/INSTALLATION MANUAL FOR ALL GAS EQUIPMENT TO | | | VERIFY COMPLIANCE WITH 2020 FBC RES. SEC. G2408.1. | | | | | | 5. PLEASE LIST THE BTU LOAD OF EACH APPLIANCE AND THE | | | TOTAL BTU LOAD ON THE SYSTEM. REFER TO THE 2020 FBC | | | RES. SEC. G2413. | | | | | | 6. PLEASE SHOW THE DISTANCE FROM THE POINT OF DELIVERY | | | (GAS METER / MP REGULATOR / LP TANK) TO THE MOST REMOTE | | | OUTLET IN THE BUILDING AND/OR SYSTEM PER THE 2020 FBC | | | RES. SEC. G2413.4.1. | | | | | | 7. GAS APPLIANCES SHALL BE LISTED AND LABELED. THE | | | INSTALLATION MANUALS FOR ALL GAS APPLIANCES/EQUIPMENT | | | SHALL BE ONSITE AT THE TIME OF INSPECTION PER THE 2020 | | | FBC RES. SEC. G2413.2 AND G2404.3. | | | | | | 8. THE GAS GRILL AND IT SEEMS TO BE IN A COVERED PATIO, | | | IF SO PLEASE PROVIDE THE MANUFACTURE'S RECOMMENDATION | | | FOR A VENTILATION HOOD PER THE 2020 FBC RES. SEC. | | | G2408.1. | | | | | | 9. NEED A HARD CAP FOR FUTURE RANGE SHOW ON GAS | | | ISOMERIC PER THE 2020 FBC RES. SEC. G2401.1.3. | | | | | | 10. IF THIS UNIT REQUIRES A CONDENSATE, IT WILL NEED TO | | | BE 1' AWAY FROM STRUCTURE PER THE 2020 FBC SEC R318.5. | | | | | | 11. PLEASE SHOW THE LOCATION OF THE TANK-LESS WATER | | | HEATER AND THE LOCATION AND DISTANCE OF ANY OPERABLE | | | DOORS OR WINDOWS IN RELATION TO THE WATER HEATER. THE | | | LOCATION OF THE WATER HEATER SHALL COMPLY WITH THE | | | MANUFACTURER'S INSTALLATION INSTRUCTIONS. THE HOUSE | | | PLAN CAN BE HAND-DRAWN PER THE WPB AMENDMENTS TO THE | | | FBC SEC. 107.2.1. INFORMATION ON CONSTRUCTION | | | DOCUMENTS. | | | | | | 12. PLEASE SHOW AND LABEL ALL UNIONS IN FRONT OF | | | REGULATOR 1' OF EITHER SIDE PER THE 2020 FBC RES. SEC | | | G2421.2. | | | | | | 13. PLEASE LABEL THE SHUT-OFF VALVE ON GAS ISOMERIC AND | | | THEY SHALL HAVE ACCESS TO THEM PER THE 2020 FBC RES. | | | SEC. G2420.5. | | | | | | WHEN RESUBMITTING PLANS, PLEASE INDICATE THE REVISION & | | | REMOVE ANY VOIDED SHEETS & REPLACE ANY NECESSARY PAGES. | | | A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW | | | COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | | THE CHANGES CAN BE FOUND WILL HELP EXPEDITE YOUR | | | PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | HTTPS://CODES.ICCSAFE.ORG/CODES/FLORIDA | | | | | | LUIS A. CRESPO | | | PLUMBING PLAN EXAMINER / INSPECTOR | | | EMAIL: [email protected] OFFICE: 561 805-6720 | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
N |
Date |
2021-04-13 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2021-04-13 |
Time |
11:14 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2021-04-13 |
Time |
11:13 |
Sent To |
|
|
| Notes |
| 2021-04-13 11:14:38 | GAS PLAN REVIEW, A GAS PLAN HAS NOT BEEN INCLUDED IN | | | THIS SUBMITTAL PACKAGE. A GAS PLAN REVIEW HAS NOT BEEN | | | PERFORMED AT THIS TIME. A SEPARATE GAS PERMIT AND PLANS | | | WILL BE REQUIRED FOR A CONTRACTOR TO PERFORM THE | | | RELATED WORK. PROVIDE COMPLETE PLANS AND GAS RISER THAT | | | REFLECTS THE ENTIRE SCOPE OF GAS WORK TO BE DONE PER | | | THE WPB AMENDMENTS TO FBC SEC. 107.2.1. | | | | | | A SUB GAS PERMIT IS REQUIRED BY A LICENSED CONTRACTOR | | | FOR THE SCOPE OF WORK PER THE WPB AMENDMENTS TO THE FBC | | | SEC. 105.1. | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
N |
Date |
2021-03-19 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2021-03-19 |
Time |
06:34 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2021-03-19 |
Time |
06:34 |
Sent To |
|
|
| Notes |
| 2021-03-19 06:34:46 | GAS PLAN REVIEW, A GAS PLAN HAS NOT BEEN INCLUDED IN | | | THIS SUBMITTAL PACKAGE. A GAS PLAN REVIEW HAS NOT BEEN | | | PERFORMED AT THIS TIME. A SEPARATE GAS PERMIT AND PLANS | | | WILL BE REQUIRED FOR A CONTRACTOR TO PERFORM THE | | | RELATED WORK. PROVIDE COMPLETE PLANS AND GAS RISER THAT | | | REFLECTS THE ENTIRE SCOPE OF GAS WORK TO BE DONE PER | | | THE WPB AMENDMENTS TO FBC SEC. 107.2.1. | | | | | | A SUB GAS PERMIT IS REQUIRED BY A LICENSED CONTRACTOR | | | FOR THE SCOPE OF WORK PER THE WPB AMENDMENTS TO THE FBC | | | SEC. 105.1. | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2021-05-11 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-05-11 |
Time |
13:45 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-05-10 |
Time |
14:29 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2021-04-28 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-04-28 |
Time |
09:25 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-04-09 |
Time |
11:40 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2021-03-23 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2021-03-23 |
Time |
08:12 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2021-02-26 |
Time |
09:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
N |
Date |
2021-05-10 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2021-05-10 |
Time |
09:22 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2021-05-10 |
Time |
09:22 |
Sent To |
|
|
| Notes |
| 2021-05-10 09:30:47 | IMPACT FEES TO BE PAID UNDER BUILDING PERMITS | | | |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2021-03-23 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2021-03-23 |
Time |
08:10 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2021-03-23 |
Time |
08:09 |
Sent To |
|
|
| Notes |
| 2021-03-23 08:11:33 | ****CORRECTIONS**** | | | | | | PETER E VALENTI | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6673 | | | | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | IMPACT FEES - DIGITAL SUBMITTALS | | | | | | PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE | | | DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS | | | OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST | | | FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE | | | OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL | | | IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME | | | THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM | | | CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS | | | TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF UPON | | | APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE RECEIPT TO | | | YOUR PROJECT OR EMAIL IT TO [email protected] . | | | | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2021-03-09 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-03-09 |
Time |
13:39 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-03-09 |
Time |
12:59 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2021-05-11 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2021-05-11 |
Time |
10:39 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2021-05-11 |
Time |
10:39 |
Sent To |
|
|
| Notes |
| 2021-05-11 10:40:32 | 05/11/21 REVIEWED FOR CODE COMPLIANCE (PLUMBING) | | | | | | BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE | | | COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN | | | PROFESSIONAL, CONTRACTORS, OR THEIR REPRESENTATIVES | | | FROM THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL, | | | STATE, AND NATIONAL CODES AND STANDARDS IN EFFECT AT | | | THE TIME OF PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK | | | OF EVERY ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM | | | REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES | | | / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO | | | AVOID VOIDING OF THE PERMIT. | | | | | | LUIS A. CRESPO | | | PLUMBING PLAN EXAMINER / INSPECTOR | | | EMAIL: [email protected] OFFICE: 561 805-6720 | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2021-04-22 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2021-04-22 |
Time |
08:33 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2021-04-22 |
Time |
08:33 |
Sent To |
|
|
| Notes |
| 2021-04-22 08:41:41 | 04/22/21 REVIEWED FOR CODE COMPLIANCE (PLUMBING) | | | | | | BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE | | | COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN | | | PROFESSIONAL, CONTRACTORS, OR THEIR REPRESENTATIVES | | | FROM THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL, | | | STATE, AND NATIONAL CODES AND STANDARDS IN EFFECT AT | | | THE TIME OF PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK | | | OF EVERY ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM | | | REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES | | | / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO | | | AVOID VOIDING OF THE PERMIT. | | | | | | LUIS A. CRESPO | | | PLUMBING PLAN EXAMINER / INSPECTOR | | | EMAIL: [email protected] OFFICE: 561 805-6720 | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2021-04-13 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2021-04-13 |
Time |
11:13 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2021-04-13 |
Time |
11:13 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2021-03-19 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2021-03-19 |
Time |
06:39 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2021-03-19 |
Time |
06:30 |
Sent To |
|
|
| Notes |
| 2021-03-19 06:40:03 | 03/19/21 2ND PLUMBING REVIEW**DENIED** WITH COMMENTS | | | | | | NOTE - A COMPREHENSIVE REVIEW COULD NOT BE DONE AT THIS | | | TIME, AND ADDITIONAL PLAN REVIEW COMMENTS MAY BE | | | GENERATED UPON THE RE-REVIEW OF SUBMITTED CORRECTIONS. | | | | | | 1. A SUB GAS PERMIT IS REQUIRED BY A LICENSED | | | CONTRACTOR FOR THE SCOPE OF WORK PER THE WPB AMENDMENTS | | | TO THE FBC SEC. 105.1. | | | | | | 2. ON PAGE A-1L; | | | A. IT SHOWS A GAS TANK-LESS. PLEASE PROVIDE A NOTE ON | | | PLANS THAT A SEPARATE PERMIT SHALL BE SUBMITTED FOR GAS | | | PER THE WPB AMENDMENTS TO THE FBC SEC. 105.1. | | | | | | B. THE TANKLESS HOT WATER LINES ON THE OUTSIDE SHALL | | | HAVE INSULATED MINIMUM R-3 PER THE 2017 FBC SEC. RE | | | 403.5.3. PLEASE PLACE A NOTE. | | | | | | C. IF THIS HAS A CONDENSATE, IT WILL NEED TO BE 1' AWAY | | | FROM THE STRUCTURE PER THE 2017 FBC SEC. R318.5. | | | | | | D. PLEASE SHOW THE TANK-LESS WATER HEATER'S LOCATION | | | AND THE LOCATION AND DISTANCE OF ANY OPERABLE DOORS OR | | | WINDOWS IN RELATION TO THE WATER HEATER. THE LOCATION | | | OF THE WATER HEATER SHALL COMPLY WITH THE | | | MANUFACTURER'S INSTALLATION INSTRUCTIONS. | | | | | | 3. ON SHEET S1L AND S1R; | | | A. THE LAUNDRY TRAY IS NOT SHOW NEXT TO WASHING | | | MACHINE. | | | | | | B. IN BATH THREE THE SINK IS NOT SIZED. | | | | | | PLEASE CORRECT THESE ITEMS PER THE WPB AMENDMENTS TO | | | THE FBC SEC. 107.2.1. INFORMATION ON CONSTRUCTION | | | DOCUMENTS. | | | | | | WHEN RESUBMITTING PLANS, PLEASE INDICATE THE REVISION & | | | REMOVE ANY VOIDED SHEETS & REPLACE ANY NECESSARY PAGES. | | | A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW | | | COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION, | | | MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | | THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR | | | PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | HTTPS://CODES.ICCSAFE.ORG/CODES/FLORIDA | | | | | | LUIS A. CRESPO | | | PLUMBING PLAN EXAMINER / INSPECTOR | | | EMAIL: [email protected] OFFICE: 561 805-6720 | | | |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
P |
Date |
2021-03-18 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-03-18 |
Time |
15:21 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-03-16 |
Time |
13:06 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
P |
Date |
2021-05-11 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-05-11 |
Time |
13:44 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-05-11 |
Time |
13:06 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2021-04-28 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-04-28 |
Time |
09:09 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-04-27 |
Time |
06:22 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2021-03-18 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-03-18 |
Time |
15:21 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-03-16 |
Time |
13:05 |
Sent To |
|
|
| Notes |
| 2021-03-18 15:24:22 | PLAN REVIEW / SIGNATURES | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | PLANS EXAMINER BUILDING - PX3169 | | | PLANS EXAMINER 1&2 FAMILY - SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | CODES IN EFFECT: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | 1ST REVIEW | | | | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | RE: MECHANICAL PLANS | | | | | | | | | 1. THE OWNER/BUILDER, CONTRACTOR OR DESIGNER OF RECORD | | | SHALL PROVIDE THEIR PRINTED NAME AND SIGNATURE ON PLAN | | | SHEETS UNDER THEIR AUTHORITY. | | | 2017 WPB AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1, SECTION 107.2.1. | | | | | | 2. EITHER UPLOAD DOCUMENTS VIA THE PROJECTDOX PORTAL | | | WITH SIGNATURE OF DESIGNER AS APPLICABLE; USE THE | | | REQUIRED NAMING CONVENTION FOR EACH DOCUMENT OR DROP | | | OFF (OR MAIL) ONE PAPER ORIGINAL WITH CONTRACTORS/O/B | | | SIGNATURE TO: | | | | | | BUILDING DIVISION, FIRST FLOOR | | | CITY OF WEST PALM BEACH | | | 401 CLEMATIS ST | | | WEST PALM BEACH, FL 33401 | | | | | | FBC 107.2.1 ALL INFORMATION, DRAWINGS, SPECIFICATIONS | | | AND ACCOMPANYING DATA SHALL BEAR THE NAME AND SIGNATURE | | | OF THE PERSON RESPONSIBLE FOR THE DESIGN. (SEE ALSO | | | SECTION 107.3.5), CHPT. 471, F.S. & 61G15 AND CHPT. | | | 481, F.S. & 61G1. | | | | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2021-04-26 |
|
|
Cont ID |
|
| Sent By |
ajones |
Date |
2021-04-22 |
Time |
10:57 |
Rev Time |
0.00 |
| Received By |
ajones |
Date |
2021-04-22 |
Time |
10:57 |
Sent To |
|
|
| Notes |
| 2021-04-22 10:58:27 | 4/21/21-4/21/21-PASS. AT TIME THE INDIVIDUAL LOTS ARE | | | SUBMITED FOR BUILDING PERMIT ZONING WILL THE SURVEY | | | AND/OR SITE PLAN SHOWING THE LOCATION/SETBACKS OF THE | | | HOME FROM THE PROPERTY LINE. | | | | | | ANGELLA VANN, AICP | | | 561-822-1441 | | | [email protected] | | | | | | ANGELLA VANN, AICP | | | 561-822-1441 | | | [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2021-03-22 |
|
|
Cont ID |
|
| Sent By |
aaponte |
Date |
2021-03-22 |
Time |
10:26 |
Rev Time |
0.00 |
| Received By |
ajones |
Date |
2021-03-22 |
Time |
10:26 |
Sent To |
|
|
| Notes |
| 2021-03-22 10:35:13 | 3/22/21-FAILED- SURVEY/SITE PLAN SHOWING SETBACKS FROM | | | THE PROPERTY LINES FOR THE HOUSE/ADDITION. | | | | | | ANGELLA VANN, AICP | | | [email protected] | | | 561-822-1441 |
|
|