Plan Review Details - Permit 21021133
| Plan Review Stops For Permit 21021133 |
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2021-04-26 |
|
|
Cont ID |
|
| Sent By |
ppetty |
Date |
2021-04-26 |
Time |
11:18 |
Rev Time |
0.00 |
| Received By |
ppetty |
Date |
2021-04-26 |
Time |
10:46 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2021-02-26 |
|
|
Cont ID |
|
| Sent By |
ppetty |
Date |
2021-02-26 |
Time |
10:22 |
Rev Time |
0.00 |
| Received By |
ppetty |
Date |
2021-02-26 |
Time |
10:22 |
Sent To |
|
|
| Notes |
| 2021-02-26 10:45:54 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2020 7TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2020 | | | 7TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 | | | 7TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2020 | | | 7TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2020 7TH EDITION | | | NEC = NFPA 70 2017 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | FAC = FLORIDA ADMINISTRATIVE CODE | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1.PROVIDE LOAD CALCULATION FOR SERVICE, INCLUDE | | | EXISTING AND NEW LOADS TO CONFIRM CAPACITY OF SERVICE | | | IS ADEQUATE. NEC 215.2, 220, 408.30; FBC RE E3602.2 | | | 2.NO INFORMATION ABOUT PANEL B ON PLAN | | | 3.PROVIDE PANEL SCHEDULE INDICATING ANY NEW OR ALTERED | | | CIRCUITS, THE WIRE AND BREAKER SIZE FOR THESE CIRCUITS, | | | AND AFCI OR GFCI PROTECTION WHERE APPLICABLE TO COMPLY | | | WITH CODE. NEC 210.8, 210.12, 210.19, 210.20, 215.5, | | | 408.4; WPB FBC 107.3.5; FBC RE E3706.2, E3902 | | | | | | | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. | | | | | | SINCERELY, | | | | | | PHIL PETTY | | | CHIEF ELECTRICAL INSPECTOR , ELECTRICAL PLANS EXAMINER | | | | | | 561-805-6742 | | | [email protected] | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2021-04-26 |
|
|
Cont ID |
|
| Sent By |
ppetty |
Date |
2021-04-26 |
Time |
11:19 |
Rev Time |
0.00 |
| Received By |
ppetty |
Date |
2021-04-20 |
Time |
13:26 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2021-02-26 |
|
|
Cont ID |
|
| Sent By |
ppetty |
Date |
2021-02-26 |
Time |
10:47 |
Rev Time |
0.00 |
| Received By |
ppetty |
Date |
2021-02-24 |
Time |
09:36 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2021-04-26 |
|
|
Cont ID |
|
| Sent By |
ppetty |
Date |
2021-04-26 |
Time |
11:18 |
Rev Time |
0.00 |
| Received By |
ppetty |
Date |
2021-04-26 |
Time |
11:18 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2021-03-01 |
|
|
Cont ID |
|
| Sent By |
ppetty |
Date |
2021-02-26 |
Time |
10:47 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-03-01 |
Time |
05:57 |
Sent To |
|
|
| Notes |
| 2021-03-01 05:59:20 | ORIGINAL SIGNED AND SEALED PAPER DRAWING ROUTED TO | | | STORAGE.ME |
|
|
|