Plan Review Details - Permit 21020990
Plan Review Stops For Permit 21020990
Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 3 Status P Date 2021-03-25 Cont ID  
Sent By pvalenti Date 2021-03-25 Time 14:53 Rev Time 0.00
Received By pvalenti Date 2021-03-25 Time 14:53 Sent To  
Notes
***NONE***

Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 2 Status F Date 2021-03-23 Cont ID  
Sent By pvalenti Date 2021-03-23 Time 08:19 Rev Time 0.00
Received By pvalenti Date 2021-03-23 Time 08:15 Sent To  
Notes
2021-03-23 08:20:36****CORRECTIONS****
  
 PETER E VALENTI
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6673
  
 FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC R = FBC RESIDENTIAL
  
 ASBESTOS REQUIREMENTS:
  
 PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE
 CONTRACTOR, ON LETTERHEAD, STATING THAT THE
 INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM
 COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH
 COUNTY WILL BE FOLLOWED AND THAT NOTIFICATION WILL BE
 GIVEN TIMELY. ADDITIONAL INFORMATION REGARDING ASBESTOS
 REQUIREMENTS CAN BE FOUND ON THEIR WEBSITE:
 HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE
 S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION-
 RENOVATION.HTML
  
 THE CONTRACTOR ACKNOWLEDGEMENT CAN BE SENT VIA EMAIL TO
 [email protected]. THE INFORMATION SHOULD BE IN PDF
 FORMAT AS AN ATTACHMENT TO THE EMAIL. PLEASE INCLUDE
 THE PERMIT NUMBER AND "ASBESTOS" IN THE SUBJECT LINE.

Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 1 Status F Date 2021-02-22 Cont ID  
Sent By shill Date 2021-02-22 Time 16:05 Rev Time 0.00
Received By shill Date 2021-02-22 Time 16:05 Sent To  
Notes
2021-02-22 16:06:27PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE
 CONTRACTOR, ON LETTERHEAD, STATING THAT THE
 INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM
 COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH
 COUNTY WILL BE FOLLOWED AND THAT NOTIFICATION WILL BE
 GIVEN TIMELY. ADDITIONAL INFORMATION REGARDING ASBESTOS
 REQUIREMENTS CAN BE FOUND ON THEIR WEBSITE:
  
 HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE
 S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION-
 RENOVATION.HTML
  
 THE CONTRACTOR ACKNOWLEDGEMENT CAN BE SENT VIA EMAIL TO
 [email protected]. THE INFORMATION SHOULD BE IN
 PDF FORMAT AS AN ATTACHMENT TO THE EMAIL. PLEASE
 INCLUDE THE PERMIT NUMBER AND "ASBESTOS" IN THE SUBJECT
 LINE.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2021-04-15 Cont ID  
Sent By pvalenti Date 2021-04-15 Time 09:13 Rev Time 0.00
Received By pvalenti Date 2021-04-15 Time 09:13 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2021-04-09 Cont ID  
Sent By pvalenti Date 2021-04-09 Time 16:47 Rev Time 0.00
Received By pvalenti Date 2021-04-09 Time 16:47 Sent To  
Notes
2021-04-09 16:55:25PETER E VALENTI
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6673
  
 FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC R = FBC RESIDENTIAL
  
 BUILDING REVIEW DENIED:
  
 FS 553.79/FBC B 107, SHEET 101.0, SECTIONS PROJECT DATA
 AND CODES FOR REFERENCE INDICATE THE 2017 6TH EDITION
 OF THE FLORIDA BUILDING CODE. THIS NEEDS TO BE CHANGED
 TO THE 2020 7TH EDITION OF THE FLORIDA BUILDING CODE.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2021-04-09 Cont ID  
Sent By pvalenti Date 2021-04-09 Time 16:04 Rev Time 0.00
Received By pvalenti Date 2021-04-09 Time 12:50 Sent To  
Notes
2021-04-09 16:07:23PETER E VALENTI
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6673
  
 FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC R = FBC RESIDENTIAL
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2021-04-09 Cont ID  
Sent By jleahy Date 2021-04-09 Time 14:53 Rev Time 0.00
Received By jleahy Date 2021-04-09 Time 11:41 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2021-03-22 Cont ID  
Sent By pleduc Date 2021-03-22 Time   Rev Time 0.00
Received By pleduc Date 2021-03-22 Time 10:28 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2021-02-23 Cont ID  
Sent By pleduc Date 2021-02-23 Time   Rev Time 0.00
Received By pleduc Date 2021-02-23 Time 14:19 Sent To  
Notes
2021-02-23 14:23:17THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE
 MARSHAL, WITH THE FOLLOWING COMMENTS:
  
 1) THERE ARE INDICATIONS OF FLOOR TILE WORK BUT NO
 SPECIFICATIONS SHEETS THAT INDICATE MEETING THE
 REQUIREMENTS PER NFPA'
  
 PER NFPA 101, CH 32
  
 30.3.3.2 INTERIOR WALL AND CEILING FINISH. INTERIOR
 WALL AND
 CEILING FINISH MATERIALS COMPLYING WITH SECTION 10.2
 SHALL BE
 PERMITTED AS FOLLOWS:
 (1) EXIT ENCLOSURES ? CLASS A
 (2) LOBBIES AND CORRIDORS ? CLASS A OR CLASS B
 (3) OTHER SPACES ? CLASS A, CLASS B, OR CLASS C
  
 30.3.3.3 INTERIOR FLOOR FINISH.
 30.3.3.3.1 INTERIOR FLOOR FINISH SHALL COMPLY WITH
 SECTION 10.2.
 30.3.3.3.2 INTERIOR FLOOR FINISH IN EXIT ENCLOSURES AND
 EXIT ACCESS
 CORRIDORS AND SPACES NOT SEPARATED FROM THEM BY WALLS
 COMPLYING
 WITH 30.3.6 SHALL BE NOT LESS THAN CLASS II.
 30.3.3.3.3 INTERIOR FLOOR FINISH SHALL COMPLY WITH
 10.2.7.1 OR
 10.2.7.2, AS APPLICABLE
  
  
 10.2.1.1 CLASSIFICATION OF INTERIOR FINISH MATERIALS
 SHALL BE IN
 ACCORDANCE WITH TESTS MADE UNDER CONDITIONS SIMULATING
 ACTUAL
 INSTALLATIONS, PROVIDED THAT THE AUTHORITY HAVING
 JURISDICTION IS
 PERMITTED TO ESTABLISH THE CLASSIFICATION OF ANY
 MATERIAL FOR WHICH
 CLASSIFICATION BY A STANDARD TEST IS NOT AVAILABLE,
 UNLESS OTHERWISE
 PROVIDED IN 10.2.1.2 OR 10.2.1.4.
 10.2.1.2 THE PROVISIONS OF 10.2.1.1 SHALL NOT APPLY TO
 MATERIALS HAVING
 A TOTAL THICKNESS OF LESS THAN 1?28 IN. (0.9 MM) THAT
 ARE APPLIED DIRECTLY
 TO THE SURFACE OF WALLS AND CEILINGS WHERE BOTH OF THE
 FOLLOWING
 CONDITIONS ARE MET:
 (1) THE WALL OR CEILING SURFACE IS A NONCOMBUSTIBLE OR
 LIMITED COMBUSTIBLE
 MATERIAL.
 (2) THE MATERIALS APPLIED MEET THE REQUIREMENTS OF
 CLASS A INTERIOR
 WALL OR CEILING FINISH WHEN TESTED IN ACCORDANCE WITH
 10.2.3,
 USING FIBER CEMENT BOARD AS THE SUBSTRATE MATERIAL.
  
 10.2.7* INTERIOR FLOOR FINISH TESTING AND
 CLASSIFICATION.
 10.2.7.1* CARPET AND CARPET LIKE INTERIOR FLOOR
 FINISHES SHALL
 COMPLY WITH ASTM D 2859, STANDARD TEST METHOD FOR
 IGNITION
 CHARACTERISTICS OF FINISHED TEXTILE FLOOR COVERING
 MATERIALS.
 10.2.7.2* FLOOR COVERINGS, OTHER THAN CARPET FOR WHICH
 10.2.2.2
 ESTABLISHES REQUIREMENTS FOR FIRE PERFORMANCE, SHALL
 HAVE A
 MINIMUM CRITICAL RADIANT FLUX OF 0.1 W/CM2.
  
 PLEASE REVIEW AND PROVIDE SPEC SHEETS.
  
  
 2) THERE ARE INDICATIONS OF CEILING, WALL & VANITY
 REPLACEMENT AND PAINTING.
  
 ANY WORK INVOLVING FIRE SPRINKLERS/FIRE ALARM SYSTEMS
 OR EQUIPMENT SHALL BE DONE UNDER SEPARATE PERMITS AND
 SHOP DRAWINGS.
  
 FIRE SPRINKLERS AND FIRE ALARM EQUIPMENT SHALL BE
 PROTECTED FROM PAINTING OR DAMAGE.
  
 THE FIRE SPRINKLER/FIRE ALARM SYSTEMS SHALL BE
 MAINTAINED THROUGHOUT DEMO AND RECONSTRUCTION.
  
 PLEASE INDICATE IF THEIR IS FIRE SPRINKLER HEADS OF
 FIRE ALARM EQUIPMENT WITHIN THE PROPOSED AREA AND
 PROVIDE A NOTE OF ACKNOWLEDGEMENT AND ENSURE
 COMPLIANCE.
  
  
 3) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET
 REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE
 ABOVE.
  
  
 4) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE
 RE-SUBMITTAL OF THE ABOVE.
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date   Cont ID  
Sent By   Date 2021-04-16 Time   Rev Time 0.00
Received By ccarvaja Date 2021-04-02 Time 12:21 Sent To  
Notes
2021-03-24 18:28:31TO BLDG DIV AUDIT
  
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2021-03-24 Cont ID  
Sent By dbattles Date 2021-03-24 Time 09:34 Rev Time 0.00
Received By dbattles Date 2021-03-18 Time 09:07 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2021-03-01 Cont ID  
Sent By shill Date 2021-03-01 Time 07:14 Rev Time 0.00
Received By shill Date 2021-02-19 Time 16:04 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status N Date 2021-02-19 Cont ID  
Sent By shill Date 2021-02-19 Time 14:45 Rev Time 0.00
Received By shill Date 2021-02-19 Time 14:45 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2021-04-09 Cont ID  
Sent By medwards Date 2021-04-09 Time 13:41 Rev Time 0.00
Received By medwards Date 2021-04-09 Time 12:47 Sent To  
Notes
2021-04-09 13:42:29NO MECHANICAL WORK SHOWN ON THE DRAWINGS FOR THIS
 PROJECT. ME

Review Stop P PLUMBING
Rev No 1 Status P Date 2021-04-16 Cont ID  
Sent By ccole Date 2021-04-16 Time 15:59 Rev Time 0.00
Received By ccole Date 2021-04-16 Time 15:40 Sent To  
Notes
***NONE***

Review Stop PRIVATEPRV PRIVATE PROVIDER DOCUMENTS
Rev No 3 Status P Date 2021-04-08 Cont ID  
Sent By shill Date 2021-04-08 Time 08:48 Rev Time 0.00
Received By shill Date 2021-04-08 Time 08:48 Sent To  
Notes
***NONE***

Review Stop PRIVATEPRV PRIVATE PROVIDER DOCUMENTS
Rev No 2 Status F Date 2021-03-24 Cont ID  
Sent By dbattles Date 2021-03-24 Time 09:33 Rev Time 0.00
Received By shill Date 2021-03-24 Time 09:33 Sent To  
Notes
2021-03-24 18:27:38****CORRECTIONS****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 1. FS553, THE PLAN REVIEW AFFIDAVIT DOES NOT INCLUDE
 THE SUPPORTING DOCUMENTS UPLOADED ON 3/18/21. HAVE THE
 PRIVATE PROVIDER REVIEW THE NEW DOCUMENTS AND PROVIDE A
 NEW PLAN REVIEW AFFIDAVIT.
  
 2. FS553.791(4)(B). A RESUME WAS PROVIDED FOR DOUG
 TAYLOR; IT IS NOT CLEAR WHICH TRADE INSPECTIONS THIS
 PRIVATE PROVIDER WILL BE PERFORMING, WILL IT BE ALL
 TRADES? IF THAT IS THE CASE, PROVIDE A STATEMENT TO
 THAT EFFECT. IF NOT, SUBMIT RESUMES FOR THE ALL PRIVATE
 PROVIDERS ON THIS PROJECT.
  
 A COPY OF THE LICENSE FOR RICHARD BENNETT, STANDARD
 INSPECTOR, BUILDING, WAS SUBMITTED. A RESUME WAS NOT
 SUBMITTED. WILL THIS PRIVATE PROVIDER BE PERFORMING
 BUILDING INSPECTIONS FOR THIS PERMIT? IF YES, PROVIDE A
 RESUME AND A STATEMENT TO THAT EFFECT.
  
  
  
  
  
  
  

Review Stop PRIVATEPRV PRIVATE PROVIDER DOCUMENTS
Rev No 1 Status F Date 2021-03-01 Cont ID  
Sent By shill Date 2021-03-01 Time 07:13 Rev Time 0.00
Received By shill Date 2021-03-01 Time 07:13 Sent To  
Notes
2021-03-01 07:14:07NEW AFFIDAVITS REQUIRED, FAILED FIRE
  
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status N Date 2021-03-23 Cont ID  
Sent By pvalenti Date 2021-03-23 Time 08:15 Rev Time 0.00
Received By pvalenti Date 2021-03-23 Time 08:15 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status N Date 2021-02-22 Cont ID  
Sent By medwards Date 2021-02-22 Time 17:16 Rev Time 0.00
Received By medwards Date 2021-02-22 Time 17:14 Sent To  
Notes
***NONE***