| Plan Review Stops For Permit 21020885 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2021-04-07 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-04-07 |
Time |
10:48 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-04-07 |
Time |
09:54 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2021-03-25 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2021-03-25 |
Time |
14:04 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2021-03-25 |
Time |
12:13 |
Sent To |
|
|
| Notes |
| 2021-03-25 14:04:41 | JONATHAN BROOKS JR. | | | BUILDING PLANS EXAMINER | | | WORK HOURS TUESDAY, THURSDAY & FRIDAY 7:00 AM TO 3:00 | | | PM | | | PHONE (561) 805-6656 | | | EMAIL: [email protected] | | | | | | 1ST REVIEW: FBC 2020 7TH EDITION | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC R = FBC RESIDENTIAL | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT | | | CITY HALL, OR EMAIL [email protected] AND REQUEST | | | THAT IT BE CONVERTED TO PROJECTDOX. | | | | | | 1 FBC R 301 FAC9N-3 FLORIDA STATE PRODUCT APPROVAL | | | FL477-R9 SELECTED SYSTEM TYPE E W-21 MPD IS -60.0. | | | PROVIDE ENGINEER'S SIGNED AND SEALED FASTENER SPACING | | | DETAIL WITH CALCULATIONS FOR PERIMETERS AND CORNERS AS | | | PER PRODUCT APPROVAL LIMITATIONS #5.7.2. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2021-03-19 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2021-03-19 |
Time |
14:37 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2021-03-19 |
Time |
13:38 |
Sent To |
|
|
| Notes |
| 2021-03-19 14:38:07 | JONATHAN BROOKS JR. | | | BUILDING PLANS EXAMINER | | | WORK HOURS TUESDAY, THURSDAY & FRIDAY 7:00 AM TO 3:00 | | | PM | | | PHONE (561) 805-6656 | | | EMAIL: [email protected] | | | | | | 1ST REVIEW: FBC 2020 7TH EDITION | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC R = FBC RESIDENTIAL | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT | | | CITY HALL, OR EMAIL [email protected] AND REQUEST | | | THAT IT BE CONVERTED TO PROJECTDOX. | | | | | | 1. FBC R 301 FAC9N-3 SUBMITTED FLORIDA DBPR PRODUCT | | | APPROVAL FL477-R9 COVERS MULTIPLE ROOF SYSTEMS FOR WOOD | | | DECKS; SYSTEM NO. W-1 THRU W-39. PLEASE SELECT SYSTEM | | | NO. USED. ALL APPLICABLE DETAILS AND ATTACHMENTS MUST | | | BE CLEARLY IDENTIFIED ON THE PRODUCT APPROVAL DRAWINGS. | | | DETAILS AND ATTACHMENTS NOT SPECIFICALLY COVERED IN | | | PRODUCT APPROVALS WILL NEED SITE-SPECIFIC ENGINEERING | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2021-03-09 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2021-03-09 |
Time |
09:49 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2021-03-09 |
Time |
07:50 |
Sent To |
|
|
| Notes |
| 2021-03-09 09:50:03 | JONATHAN BROOKS JR. | | | BUILDING PLANS EXAMINER | | | WORK HOURS TUESDAY & THURSDAY 7:00 AM TO 3:00 PM | | | PHONE (561) 805-6656 | | | EMAIL: [email protected] | | | | | | 1ST REVIEW: FBC 2020 7TH EDITION | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC R = FBC RESIDENTIAL | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT | | | CITY HALL, OR EMAIL [email protected] AND REQUEST | | | THAT IT BE CONVERTED TO PROJECTDOX. | | | | | | 1. FBC B 107.2.1. SUBMITTED FLORIDA DBPR PRODUCT | | | APPROVAL FL11288 R-17 IS THE 2017 CODE VERSION AND IS | | | NO LONGER VALID. PLEASE PROVIDE A COMPLETE SET OF 2020 | | | CODE VERSION PRODUCT APPROVALS/NOA?S FOR THE PROPOSED | | | ROOF UNDERLAYMENT USED. INCLUDE COVER PAGE, EVALUATION | | | REPORTS AND INSTALLATION INSTRUCTIONS FOR SYSTEM USED. | | | 2. FBC B 107.2.1. SUBMITTED FLORIDA DBPR PRODUCT | | | APPROVAL FL6332-R8 IS THE 2017 CODE VERSION AND IS NO | | | LONGER VALID. PLEASE PROVIDE A COMPLETE SET OF 2020 | | | CODE VERSION PRODUCT APPROVALS/NOA?S FOR THE PROPOSED | | | ADHESIVE USED. INCLUDE COVER PAGE, EVALUATION REPORTS | | | AND INSTALLATION INSTRUCTIONS FOR SYSTEM USED. | | | 3. PROVIDE A COMPLETE SET OF 2020 CODE VERSION PRODUCT | | | APPROVALS/NOA'S FOR THE PROPOSED FLAT ROOF SYSTEM TO BE | | | USED. INCLUDE COVER PAGE, EVALUATION REPORTS AND | | | INSTALLATION INSTRUCTIONS FOR SYSTEM USED. ALL | | | APPLICABLE DETAILS AND ATTACHMENTS MUST BE CLEARLY | | | IDENTIFIED ON THE PRODUCT APPROVAL DRAWINGS. DETAILS | | | AND ATTACHMENTS NOT SPECIFICALLY COVERED IN PRODUCT | | | APPROVALS WILL NEED SITE-SPECIFIC ENGINEERING. | | | 4. FBC R 301 FAC9N-3. PROVIDE A COMPLETE SET OF 2020 | | | CODE VERSION PRODUCT APPROVALS/NOA'S FOR THE PROPOSED | | | HIP & RIDGE METAL/PLASTIC/WOOD TO BE USED. | | | 5. FBC B 107.2.1. SUBMITTED FLORIDA DBPR PRODUCT | | | APPROVAL FL17152 IS THE 2010 CODE VERSION AND IS NO | | | LONGER VALID. PLEASE PROVIDE A COMPLETE SET OF 2020 | | | CODE VERSION PRODUCT APPROVALS/NOA?S FOR THE PROPOSED | | | ROOFING TILES USED. INCLUDE COVER PAGE, EVALUATION | | | REPORTS AND INSTALLATION INSTRUCTIONS FOR SYSTEM USED. | | | |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
2 |
Status |
P |
Date |
2021-03-19 |
|
|
Cont ID |
|
| Sent By |
aborngra |
Date |
2021-03-19 |
Time |
11:26 |
Rev Time |
0.00 |
| Received By |
aborngra |
Date |
2021-03-19 |
Time |
11:26 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
P |
Date |
2021-03-05 |
|
|
Cont ID |
|
| Sent By |
aborngra |
Date |
2021-03-05 |
Time |
16:47 |
Rev Time |
0.00 |
| Received By |
aborngra |
Date |
2021-03-05 |
Time |
16:36 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2021-04-07 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-04-07 |
Time |
10:48 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-04-01 |
Time |
16:47 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2021-03-25 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2021-03-25 |
Time |
14:04 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2021-03-22 |
Time |
16:41 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2021-03-19 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2021-03-19 |
Time |
14:38 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2021-03-17 |
Time |
16:57 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2021-03-09 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2021-03-09 |
Time |
09:50 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2021-03-01 |
Time |
08:30 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
4 |
Status |
N |
Date |
2021-04-07 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-04-07 |
Time |
10:46 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-04-07 |
Time |
10:20 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
F |
Date |
2021-03-25 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2021-03-25 |
Time |
14:03 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2021-03-25 |
Time |
12:13 |
Sent To |
|
|
| Notes |
| 2021-03-25 14:03:29 | JONATHAN BROOKS JR. | | | BUILDING PLANS EXAMINER | | | WORK HOURS TUESDAY, THURSDAY & FRIDAY 7:00 AM TO 3:00 | | | PM | | | PHONE (561) 805-6656 | | | EMAIL: [email protected] | | | | | | 1ST REVIEW: FBC 2020 7TH EDITION | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC R = FBC RESIDENTIAL | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT | | | CITY HALL, OR EMAIL [email protected] AND REQUEST | | | THAT IT BE CONVERTED TO PROJECTDOX. | | | | | | FS471, DOCUMENTS PREPARED BY AN ENGINEER AND SUBMITTED | | | FOR PUBLIC RECORD ARE TO BE SIGNED, SEALED, DATED | | | ORIGINALS. A SCAN OF A SIGNED PLAN IS NOT CONSIDERED AN | | | ORIGINAL. | | | EITHER EMAIL A DIGITALLY OR ELECTRONICALLY SIGNED PLAN | | | TO ME, OR YOU CAN MAIL ONE ORIGINAL SIGNED AND SEALED | | | PAPER ORIGINAL WITH A WET SIGNATURE TO: | | | PETER VALENTI | | | BUILDING PLANS EXAMINER II | | | BUILDING DIVISION | | | CITY OF WEST PALM BEACH | | | 401 CLEMATIS STREET, 1ST FLOOR | | | WEST PALM BEACH, FL 33401 | | | FEEL FREE TO CONTACT ME IF YOU WISH TO DISCUSS, | | | 561-805-6673. | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
F |
Date |
2021-03-19 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2021-03-19 |
Time |
14:36 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2021-03-19 |
Time |
13:39 |
Sent To |
|
|
| Notes |
| 2021-03-19 14:37:17 | JONATHAN BROOKS JR. | | | BUILDING PLANS EXAMINER | | | WORK HOURS TUESDAY, THURSDAY & FRIDAY 7:00 AM TO 3:00 | | | PM | | | PHONE (561) 805-6656 | | | EMAIL: [email protected] | | | | | | 1ST REVIEW: FBC 2020 7TH EDITION | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC R = FBC RESIDENTIAL | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC | | | RESULTS: DENIED | | | | | | FS471, DOCUMENTS PREPARED BY AN ENGINEER AND SUBMITTED | | | FOR PUBLIC RECORD ARE TO BE SIGNED, SEALED, DATED | | | ORIGINALS. A SCAN OF A SIGNED PLAN IS NOT CONSIDERED AN | | | ORIGINAL. | | | EITHER EMAIL A DIGITALLY OR ELECTRONICALLY SIGNED PLAN | | | TO ME, OR YOU CAN MAIL ONE ORIGINAL SIGNED AND SEALED | | | PAPER ORIGINAL WITH A WET SIGNATURE TO: | | | PETER VALENTI | | | BUILDING PLANS EXAMINER II | | | BUILDING DIVISION | | | CITY OF WEST PALM BEACH | | | 401 CLEMATIS STREET, 1ST FLOOR | | | WEST PALM BEACH, FL 33401 | | | FEEL FREE TO CONTACT ME IF YOU WISH TO DISCUSS, | | | 561-805-6673. | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2021-03-09 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2021-03-09 |
Time |
09:48 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2021-03-09 |
Time |
09:25 |
Sent To |
|
|
| Notes |
| 2021-03-09 09:48:55 | JONATHAN BROOKS JR. | | | BUILDING PLANS EXAMINER | | | WORK HOURS TUESDAY & THURSDAY 7:00 AM TO 3:00 PM | | | PHONE (561) 805-6656 | | | EMAIL: [email protected] | | | | | | 1ST REVIEW: FBC 2020 7TH EDITION | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC R = FBC RESIDENTIAL | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC | | | RESULTS: DENIED | | | | | | FS471, DOCUMENTS PREPARED BY AN ENGINEER AND SUBMITTED | | | FOR PUBLIC RECORD ARE TO BE SIGNED, SEALED, DATED | | | ORIGINALS. A SCAN OF A SIGNED PLAN IS NOT CONSIDERED AN | | | ORIGINAL. | | | EITHER EMAIL A DIGITALLY OR ELECTRONICALLY SIGNED PLAN | | | TO ME, OR YOU CAN MAIL ONE ORIGINAL SIGNED AND SEALED | | | PAPER ORIGINAL WITH A WET SIGNATURE TO: | | | PETER VALENTI | | | BUILDING PLANS EXAMINER II | | | BUILDING DIVISION | | | CITY OF WEST PALM BEACH | | | 401 CLEMATIS STREET, 1ST FLOOR | | | WEST PALM BEACH, FL 33401 | | | FEEL FREE TO CONTACT ME IF YOU WISH TO DISCUSS, | | | 561-805-6673. | | | |
|
|