| Plan Review Stops For Permit 21020639 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2021-04-16 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-04-16 |
Time |
10:36 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-04-16 |
Time |
10:36 |
Sent To |
|
|
| Notes |
| 2021-04-16 10:39:01 | UNABLE TO ADD APPROVAL STAMP |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2021-04-08 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-04-08 |
Time |
09:46 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-04-08 |
Time |
09:46 |
Sent To |
|
|
| Notes |
| 2021-04-08 09:50:05 | ELEVATOR | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected] | | | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 | | | AMENDMENTS | | | | | | NO CHANGES SINCE LAST REVIEW - REVIEW #3 | | | | | | CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107 | | | 1) PLEASE PROVIDE A FLOOR PLAN SHOWING THE LOCATION OF | | | THE ELEVATOR. | | | 2) PLEASE SHOW WALL FRAMING DETAILS AROUND THE | | | ELEVATOR. | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2021-03-29 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-03-29 |
Time |
13:32 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-03-29 |
Time |
13:32 |
Sent To |
|
|
| Notes |
| 2021-03-29 13:32:51 | ELEVATOR | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected] | | | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 | | | AMENDMENTS | | | | | | NO CHANGES SINCE LAST REVIEW | | | | | | CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107 | | | 1) PLEASE PROVIDE A FLOOR PLAN SHOWING THE LOCATION OF | | | THE ELEVATOR. | | | 2) PLEASE SHOW WALL FRAMING DETAILS AROUND THE | | | ELEVATOR. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2021-03-11 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-03-11 |
Time |
13:00 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-03-11 |
Time |
12:39 |
Sent To |
|
|
| Notes |
| 2021-03-11 13:00:28 | ELEVATOR | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected] | | | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 | | | AMENDMENTS | | | | | | CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107 | | | 1) PLEASE PROVIDE A FLOOR PLAN SHOWING THE LOCATION OF | | | THE ELEVATOR. | | | 2) PLEASE SHOW WALL FRAMING DETAILS AROUND THE | | | ELEVATOR. | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2021-04-06 |
|
|
Cont ID |
|
| Sent By |
fgiaquin |
Date |
2021-04-06 |
Time |
21:14 |
Rev Time |
0.00 |
| Received By |
fgiaquin |
Date |
2021-04-06 |
Time |
20:01 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2021-03-23 |
|
|
Cont ID |
|
| Sent By |
fgiaquin |
Date |
2021-03-23 |
Time |
22:40 |
Rev Time |
0.00 |
| Received By |
fgiaquin |
Date |
2021-03-23 |
Time |
21:33 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2021-02-20 |
|
|
Cont ID |
|
| Sent By |
fgiaquin |
Date |
2021-02-20 |
Time |
21:42 |
Rev Time |
0.00 |
| Received By |
fgiaquin |
Date |
2021-02-20 |
Time |
21:06 |
Sent To |
|
|
| Notes |
| 2021-02-20 21:42:33 | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. PROVIDE CLEAR ELECTRICAL DRAWING OF WHERE REQUIRED | | | ELECTRICAL WORK IS LOCATED IN HOME. FBC 107.2.1 | | | | | | 2. PROVIDE LOAD CACLUATION OF EXISTING SERVICE TO | | | INCLUDE BOTH NEW AND EXISTING LOADS. NEC 220 FBC | | | 107.2.1 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | CODES IN EFFECT: | | | | | | HTTP://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/B | | | UILDING-PERMIT-FORMS | | | | | | FBC = FLORIDA BUILDING CODE 2020 7TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE 2020 7TH ED. | | | FBC EB = FLORIDA BUILDING CODE EXISTING BUILDING 2020 | | | 7TH EDITION | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 | | | 7TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2020 7TH EDITION | | | NEC = NFPA 70 2017 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | V/R, | | | | | | FRANK GIAQUINTO III | | | ELECTRICAL INSPECTOR | | | ELECTRICAL PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | [email protected] | | | CELL: 561-657-1653 | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2021-04-16 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-04-16 |
Time |
10:39 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-04-14 |
Time |
12:49 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2021-04-08 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-04-08 |
Time |
09:50 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-04-05 |
Time |
12:49 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2021-03-29 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-03-29 |
Time |
13:33 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-03-15 |
Time |
15:53 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2021-03-11 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-03-11 |
Time |
13:01 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-02-16 |
Time |
08:33 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
4 |
Status |
P |
Date |
2021-04-16 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-04-16 |
Time |
10:36 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-04-16 |
Time |
10:36 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
P |
Date |
2021-04-08 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-04-08 |
Time |
09:50 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-04-08 |
Time |
09:50 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
F |
Date |
2021-03-29 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-03-29 |
Time |
13:33 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-03-29 |
Time |
13:33 |
Sent To |
|
|
| Notes |
| 2021-03-29 13:33:24 | SIGNED AND SEALED DRAWINGS IN PROJECTDOX NEED TO BE | | | DIGITALLY/ELECTRONICALLY SIGNED BY THE ENGINEER OR | | | ARCHITECT TO BE USED IN ELECTRONIC PLAN REVIEW. | | | DRAWINGS DO NOT SHOW IN "ADOBE READER" AS | | | DIGITALLY/ELECTRONICALLY SIGNED. - OR - IF YOUR | | | ARCHITECT OR ENGINEER DOES NOT HAVE AN ELECTRONIC OR | | | DIGITAL SIGNATURE ? YOU CAN MAIL IN OR DROP OFF THE | | | ORIGINAL SIGNED AND SEALED DRAWINGS/DOCUMENTS TO THE | | | FRONT DESK IN THE BUILDING DEPT. AT THE CITY HALL |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2021-03-11 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-03-11 |
Time |
13:00 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-03-11 |
Time |
13:00 |
Sent To |
|
|
| Notes |
| 2021-03-11 13:01:32 | SIGNED AND SEALED DRAWINGS IN PROJECTDOX NEED TO BE | | | DIGITALLY/ELECTRONICALLY SIGNED BY THE ENGINEER OR | | | ARCHITECT TO BE USED IN ELECTRONIC PLAN REVIEW. | | | DRAWINGS DO NOT SHOW IN "ADOBE READER" AS | | | DIGITALLY/ELECTRONICALLY SIGNED. - OR - IF YOUR | | | ARCHITECT OR ENGINEER DOES NOT HAVE AN ELECTRONIC OR | | | DIGITAL SIGNATURE ? YOU CAN MAIL IN OR DROP OFF THE | | | ORIGINAL SIGNED AND SEALED DRAWINGS/DOCUMENTS TO THE | | | FRONT DESK IN THE BUILDING DEPT. AT THE CITY HALL |
|
|