| Plan Review Stops For Permit 21020594 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2021-04-27 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-04-27 |
Time |
13:42 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-04-27 |
Time |
13:42 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2021-04-14 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-04-14 |
Time |
16:47 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-04-14 |
Time |
15:38 |
Sent To |
|
|
| Notes |
| 2021-04-14 16:49:35 | PLAN REVIEW BUILDING | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | PLANS EXAMINER PX3169 1&2 FAMILY - SFP306 | | | INSPECTOR BN4338 | | | BUILDING OFFICIAL BU1635 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | CODES IN EFFECT: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | 2017 NEC | | | | | | 1ST REVIEW | | | | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. PROVIDE A SITE DRAINAGE PLAN. | | | | | | FBC R401.3 SITE DRAINAGE | | | PROVIDE A SITE DRAINAGE PLAN SHOWING COMPLIANCE WITH | | | FBC R401.3 DRAINAGE. | | | SURFACE DRAINAGE SHALL BE DIVERTED TO A STORM SEWER | | | CONVEYANCE OR OTHER APPROVED POINT OF COLLECTION THAT | | | DOES NOT CREATE A HAZARD. | | | LOTS SHALL BE GRADED TO DRAIN SURFACE WATER AWAY FROM | | | FOUNDATION WALLS. THE GRADE SHALL FALL A MINIMUM OF 6 | | | INCHES WITHIN THE FIRST 10 FEET. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2021-03-09 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-03-09 |
Time |
10:24 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-03-09 |
Time |
06:28 |
Sent To |
|
|
| Notes |
| 2021-02-25 15:04:46 | PLAN REVIEW / BUILDING | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | PLANS EXAMINER PX3169 / 1&2 FAMILY SFP306 | | | INSPECTOR BN4338 | | | BUILDING OFFICIAL BU1635 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | CODES IN EFFECT: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | 2017 NEC | | | | | | 1ST REVIEW | | | | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. PROVIDE COMPLETE NOA 20-0723.14. ONLY PAGE 1 | | | SUBMITTED. | | | 2. PROVIDE COVER PAGE FOR FL15180.6 | | | 3. PROVIDE NOA 17-0614.15 FOR PICTURE WINDOW. | | | 4. PROVIDE NOA15-180.1 FOR EXT. DOORS. | | | FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE | | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2021-02-22 |
|
|
Cont ID |
|
| Sent By |
fgiaquin |
Date |
2021-02-22 |
Time |
21:00 |
Rev Time |
0.00 |
| Received By |
fgiaquin |
Date |
2021-02-22 |
Time |
20:02 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
P |
Date |
2021-04-14 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-04-14 |
Time |
16:49 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-04-14 |
Time |
15:38 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2021-02-25 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-02-25 |
Time |
14:15 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-02-25 |
Time |
10:38 |
Sent To |
|
|
| Notes |
| 2021-02-25 14:25:51 | PLAN REVIEW FUEL GAS | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | PLANS EXAMINER PX3169 / 1&2 FAMILY SFP306 | | | INSPECTOR BN4338 | | | BUILDING OFFICIAL BU1635 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | CODES IN EFFECT: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | 2017 NEC | | | | | | 1ST REVIEW | | | | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | | | | 1. SUBMIT MANUFACTURERS SPECIFICATION | | | SHEETS/INSTALLATION MANUAL FOR ALL GAS EQUIPMENT TO | | | VERIFY COMPLIANCE WITH 2017 FBC FUEL GAS SEC.305.1 OR | | | 2017 FBC FUEL GAS RES. SEC. G2408.1. | | | | | | 2. SUBMIT LOW PRESSURE GAS REGULATOR SPECIFICATIONS. | | | 2017 FBC FUEL GAS SEC.305.1 OR 2017 FBC FUEL GAS RES. | | | SEC. G2408.1. | | | | | | 3. REGULATORS SHALL HAVE A UNION INSTALLED WITHIN 1 | | | FOOT OF EITHER SIDE OF THE REGULATOR FBC FG 410.2 | | | | | | 4. PER TABLE 402.4 (15) THE CSST SHOULD BE SIZE 25. | | | 180,000 BTUH / LONGEST RUN OF 10 FEET = SIZE 25. | | | CORRECT GAS PIPE SIZING TABLE. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2021-04-28 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2021-04-28 |
Time |
10:47 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2021-04-27 |
Time |
16:11 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2021-04-27 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-04-27 |
Time |
13:44 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-04-19 |
Time |
14:19 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2021-04-14 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2021-04-14 |
Time |
17:06 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2021-03-31 |
Time |
09:16 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2021-03-26 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2021-03-26 |
Time |
07:01 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2021-02-17 |
Time |
04:42 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
P |
Date |
2021-05-09 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2021-05-09 |
Time |
08:32 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2021-04-27 |
Time |
15:36 |
Sent To |
|
|
| Notes |
| 2021-05-04 09:01:37 | RECEIPT MU-2021-20831 - $2491.56 - PAID | | 2021-04-27 15:36:37 | 4/27/21 EMAILED IMPACT OFFICE FOR REVIEW. LEM |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2021-02-25 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-02-25 |
Time |
14:39 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-02-25 |
Time |
14:39 |
Sent To |
|
|
| Notes |
| 2021-02-25 14:41:22 | PALM BEACH COUNTY IMPACT FEES - DIGITAL SUBMITTALS | | | | | | PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE | | | DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS | | | OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST | | | FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE | | | OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL | | | IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME | | | THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM | | | CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS | | | TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF UPON | | | APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE RECEIPT TO | | | YOUR PROJECT OR EMAIL IT TO [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2021-04-28 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-04-28 |
Time |
08:59 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-04-28 |
Time |
08:59 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
F |
Date |
2021-04-27 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-04-27 |
Time |
13:43 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-04-27 |
Time |
13:42 |
Sent To |
|
|
| Notes |
| 2021-04-27 13:44:16 | OWNER WILL UPLOAD NEW MECH PLAN WITH VALID DIGITAL | | | SIGNATURE. CT |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2021-04-12 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-04-08 |
Time |
12:48 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-04-08 |
Time |
12:41 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2021-02-23 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-02-23 |
Time |
13:41 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-02-23 |
Time |
13:31 |
Sent To |
|
|
| Notes |
| 2021-02-23 13:42:07 | 1ST REVIEW FBC-2020 MECHANICAL | | | PERMIT21020594 | | | | | | CODES IN EFFECT: | | | | | | FBC B- FLORIDA BUILDING CODE | | | FBC M- FLORIDA MECHANICAL CODE | | | FBC EC- FLORIDA ENERGY CONSERVATION | | | FBC FG- FLORIDA FUEL GAS | | | FBC EX- FLORIDA EXISTING BUILDING CODE | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) PLEASE PROVIDE A DRAWING OF THE ADDITION WITH THE | | | MECHANICAL SYSTEM ON IT. THE ONES SUBMITTED DO NOT SHOW | | | IF THERE IS AN OPEN STAIRWAY FOR THE RETURN AIR PATH. | | | IS THE AHU LOCATED IN THE ATTIC? IF SO PLEASE SHOW THE | | | ATTIC ACCESS. NOTES ON LEVEL 1 INDICATE AN AC CLOSET, | | | PLEASE SHOW THIS A/C CLOSET WITH THE AHU INSIDE IT. | | | | | | 2) PLEASE PROVIDE ANCHORAGE DETAILS FOR THE CONDENSING | | | UNIT. FBC RES M1307.2 | | | | | | 3) PLEASE SHOW THE CONDENSATE PIPING ALONG WITH THE | | | DISPOSAL LOCATION. FBC RES M1411.3 | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE OLD | | | SHEETS FROM THE PLAN SETS, BIND THEM TOGETHER | | | SEPARATELY AND MARK VOID OR OLD ON THEM. PLEASE RETAIN | | | THEM FOR REFERENCE WITH THE NEW SUBMITTED PLANS. THIS | | | PROCESS WILL ALSO APPLY TO ANY DOCUMENTS SUCH AS | | | PRODUCT APPROVALS OR CALCULATIONS BEING REPLACED OR | | | UPDATED. | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2021-04-14 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-04-14 |
Time |
16:49 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-04-14 |
Time |
15:38 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2021-02-25 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-02-25 |
Time |
14:50 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-02-25 |
Time |
07:11 |
Sent To |
|
|
| Notes |
| 2021-02-25 15:00:25 | PROVISO: TUB/SHOWER CONTROL VALVES SHALL COMPLY WITH | | | P2708.4. CT |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
2 |
Status |
P |
Date |
2021-04-14 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-04-14 |
Time |
16:16 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-04-14 |
Time |
15:38 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2021-03-09 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-03-09 |
Time |
12:01 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-03-09 |
Time |
06:28 |
Sent To |
|
|
| Notes |
| 2021-03-09 12:05:34 | PLAN REVIEW / ROOFING | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | PLANS EXAMINER PX3169 / 1&2 FAMILY SFP306 | | | INSPECTOR BN4338 | | | BUILDING OFFICIAL BU1635 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | CODES IN EFFECT: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | 2017 NEC | | | | | | 1ST REVIEW | | | | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. PROVIDE COMPLETE NOA20-0723.14. (ONLY COVER PAGE | | | SUBMITTED) | | | 2. PROVIDE COMPLETE NOA 19-1118.07. (ONLY COVER PAGE | | | SUBMITTED) | | | | | | FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE | | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
6 |
Status |
P |
Date |
2021-04-28 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2021-04-28 |
Time |
10:45 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2021-04-28 |
Time |
10:33 |
Sent To |
|
|
| Notes |
| 2021-04-28 10:46:36 | SOIL TEST REPORT WITH ENGINEER'S EMBOSSED SEAL AND | | | ORIGINAL SIGNATURE. JG. |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
5 |
Status |
P |
Date |
2021-04-28 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-04-28 |
Time |
08:59 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-04-28 |
Time |
08:59 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
4 |
Status |
F |
Date |
2021-04-20 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2021-04-20 |
Time |
16:35 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2021-04-20 |
Time |
15:33 |
Sent To |
|
|
| Notes |
| 2021-04-20 16:36:07 | SIGNATURE REVIEW COMMENTS: | | | | | | 1- A/C HOLD DOWN ANCHORS ENGINEERING SUBMITTED WITH | | | ENGINEER'S ORIGINAL SEAL/SIGNATURE IS NOT THE SAME | | | ENGINEER SHOWN ON THE TITLE BLOCK. THE ENGINEER'S | | | SEAL/SIGNATURE CORRESPONDS TO FRANK L BENNARDO LICENSE | | | #46549. THE ENGINEER SHOWN IN THE TITLE BLOCK IS | | | RICHARD NEET LICENSE #86488. DOCUMENTS NEEDS TO BE | | | SIGNED/SEALED BY THE ENGINEER LISTED IN THE TITLE | | | BLOCK. | | | NOTE: | | | PLANS/DOCUMENTS TO HAVE THE ENGINEER'S ORIGINAL | | | SEAL/SIGNATURE AS REQUIRED BY 471 F.S. WHEN SUBMITTING | | | PLANS /DOCUMENTS FOR PUBLIC RECORDS. PLANS CAN BE | | | UPLOADED TO PROJECTDOX WITH DIGITAL SIGNATURE OR HARD | | | COPIES WITH ENGINEER'S ORIGINAL SIGNATURE/SEAL MAY BE | | | DROPPED OFF IN CITY HALL. | | | | | | 2- SOIL TEST REPORT UPLOADED TO PROJECTDOX IN THE | | | SUPPORTING DOCUMENTS HAVE A COPY OF THE ENGINEER'S | | | SIGNATURE. NEED TO HAVE THE ORIGINAL SEAL AND SIGNATURE | | | OF THE ENGINEER OF RECORD AS REQUIRED BY 471 F.S. WHEN | | | SUBMITTING PLANS/DOCUMENTS FOR PUBLIC RECORDS. | | | | | | NOTE: | | | PLANS/DOCUMENTS TO HAVE THE ENGINEER'S ORIGINAL | | | SEAL/SIGNATURE AS REQUIRED BY 471 F.S. WHEN SUBMITTING | | | PLANS /DOCUMENTS FOR PUBLIC RECORDS. PLANS CAN BE | | | UPLOADED TO PROJECTDOX WITH DIGITAL SIGNATURE OR HARD | | | COPIES WITH ENGINEER'S ORIGINAL SIGNATURE/SEAL MAY BE | | | DROPPED OFF IN CITY HALL. | | | | | | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY | | | QUESTIONS REGARDING THESE COMMENTS, | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
F |
Date |
2021-04-20 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2021-04-20 |
Time |
09:59 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2021-04-20 |
Time |
09:59 |
Sent To |
|
|
| Notes |
| 2021-04-20 10:27:38 | SIGNATURE REVIEW COMMENTS: | | | | | | 1- A/C HOLD DOWN ANCHORS ENGINEERING SUBMITTED WITH | | | ENGINEER'S ORIGINAL SEAL/SIGNATURE IS NOT THE SAME | | | ENGINEER SHOWN ON THE TITLE BLOCK. THE ENGINEER'S | | | SEAL/SIGNATURE CORRESPONDS TO FRANK L BENNARDO LICENSE | | | #46549. THE ENGINEER SHOWN IN THE TITLE BLOCK IS | | | RICHARD NEET LICENSE #86488. DOCUMENTS NEEDS TO BE | | | SIGNED/SEALED BY THE ENGINEER LISTED IN THE TITLE | | | BLOCK. | | | NOTE: | | | PLANS/DOCUMENTS TO HAVE THE ENGINEER'S ORIGINAL | | | SEAL/SIGNATURE AS REQUIRED BY 471 F.S. WHEN SUBMITTING | | | PLANS /DOCUMENTS FOR PUBLIC RECORDS. PLANS CAN BE | | | UPLOADED TO PROJECTDOX WITH DIGITAL SIGNATURE OR HARD | | | COPIES WITH ENGINEER'S ORIGINAL SIGNATURE/SEAL MAY BE | | | DROPPED OFF IN CITY HALL. | | | | | | 2- SOIL TEST REPORT UPLOADED TO PROJECTDOX IN THE | | | SUPPORTING DOCUMENTS HAVE A COPY OF THE ENGINEER'S | | | SIGNATURE. NEED TO HAVE THE ORIGINAL SEAL AND SIGNATURE | | | OF THE ENGINEER OF RECORD AS REQUIRED BY 471 F.S. WHEN | | | SUBMITTING PLANS/DOCUMENTS FOR PUBLIC RECORDS. | | | | | | NOTE: | | | PLANS/DOCUMENTS TO HAVE THE ENGINEER'S ORIGINAL | | | SEAL/SIGNATURE AS REQUIRED BY 471 F.S. WHEN SUBMITTING | | | PLANS /DOCUMENTS FOR PUBLIC RECORDS. PLANS CAN BE | | | UPLOADED TO PROJECTDOX WITH DIGITAL SIGNATURE OR HARD | | | COPIES WITH ENGINEER'S ORIGINAL SIGNATURE/SEAL MAY BE | | | DROPPED OFF IN CITY HALL. | | | | | | 3- MECHANICAL PLANS FOR LEVEL 1 AND LEVEL 2 HAVE A COPY | | | OF THE ARCHITECT'S SEAL/SIGNATURE. PLANS NEED TO HAVE | | | ARCHITECT'S ORIGINAL SEAL AND SIGNATURE WHEN SUBMITTING | | | DOCUMENTS FOR PUBLIC RECORDS AS REQUIRED BY 61G1-16.003 | | | FAC. PLANS WERE SUBMITTED ELECTRONICALLY. ARCHITECT TO | | | PROVIDE PLANS WITH DIGITAL SIGNATURE OR PROVIDE HARD | | | COPY PLANS WITH THE ORIGINAL SEAL AND SIGNATURE. | | | NOTE: PLEASE UPLOAD THESE DRAWINGS IN THE "DRAWINGS" | | | FOLDER NOT IN THE SUPPORTING DOCUMENTS FOLDER AS | | | REQUIRED BY CITY PROCEDURES FOR DIGITAL PLAN REVIEW | | | GUIDELINES. | | | | | | | | | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY | | | QUESTIONS REGARDING THESE COMMENTS, | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
F |
Date |
2021-04-08 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-04-08 |
Time |
13:06 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-04-08 |
Time |
13:06 |
Sent To |
|
|
| Notes |
| 2021-04-08 13:09:31 | THE ORIGINAL A/C TIED DOWN DOCUMENTATION MUST BE | | | SUBMITTED WITH THE ORIGINAL DIGITAL SIGNATURE. F.S. | | | 471.003 | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | | | | | | | | | | | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2021-02-23 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-02-23 |
Time |
13:48 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-02-23 |
Time |
13:48 |
Sent To |
|
|
| Notes |
| 2021-02-23 13:53:14 | THE DUCT LAYOUT SHEETS APPEAR TO HAVE A COPY OF THE | | | ARCHITECT SEAL AND SIGNATURE. PLEASE SUBMIT THE | | | ORIGINAL DIGITAL SIGNATURE AND SEAL OF THE ARCHITECT'S | | | OR YOU CAN BRING THE ORIGINAL SIGNED AND SEALED | | | DRAWINGS TO OUR OFFICE. | | | | | | PER THE WPB AMENDMENTS TO THE FBC, EACH SHEET OF PLAN | | | (INCLUDING THE SUPPORTING DOCUMENTS) IS REQUIRED TO BE | | | SIGNED AND SEALED BY THE PERSON RESPONSIBLE FOR THE | | | DESIGN. A DIGITAL PLAN REQUIRES A DIGITAL SIGNATURE | | | WITH THE PROPER THIRD PARTY VERIFICATION. PROVIDE | | | CORRECTION. ALTERNATIVELY, A SIGNED/SEALED PAPER SET | | | MAY BE SUPPLIED TO THE BUILDING DEPARTMENT WHEN ALL | | | TRADES ARE APPROVED. WPB FBC 107.1; FS 471/481 | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2021-03-25 |
|
|
Cont ID |
|
| Sent By |
kalexand |
Date |
2021-03-25 |
Time |
|
Rev Time |
|
| Received By |
rthermid |
Date |
2021-03-25 |
Time |
|
Sent To |
I |
|
| Notes |
|
|