Plan Review Details - Permit 21020567
Plan Review Stops For Permit 21020567
Review Stop AD ADDRESSING
Rev No 1 Status P Date 2021-05-10 Cont ID  
Sent By cpuell Date 2021-05-10 Time 10:03 Rev Time 0.00
Received By cpuell Date 2021-05-10 Time 10:03 Sent To  
Notes
2021-05-10 10:04:33ADDRESS CHANGED FROM 315 PILGRIM TO 301 PILGRIM,
 PROPERTY WAS OUT OF SEQUENCE. OK PER OWNER.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2021-04-26 Cont ID  
Sent By rmcphers Date 2021-04-26 Time 16:37 Rev Time 0.00
Received By rmcphers Date 2021-04-26 Time 16:37 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2021-03-15 Cont ID  
Sent By rmcphers Date 2021-03-15 Time 13:25 Rev Time 0.00
Received By rmcphers Date 2021-03-15 Time 12:21 Sent To  
Notes
2021-03-15 13:22:13SFR ADDITION/REMODEL
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected]
 CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1
 AMENDMENTS
  
 CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107
 1) ALL PRODUCT APPROVALS NEED TO BE REVIEWED AND MARKED
 APPROVED BY THE BUILDING DESIGNER OF RECORD FBC WPB
 AMENDMENTS 107.3.4
 2) PLEASE PROVIDE A COMPLETE MIAMI DADE OR FLORIDA
 STATE GARAGE OVERHEAD DOOR PRODUCT APPROVAL.
 3) DRAWING A/B-1 SHOWS WIND DESIGN CALCULATED PER ASCE
 7-10 - SHOULD BE CALCULATED PER ASCE 7-16 PER 2020 FBC.
  
2021-03-02 06:23:253/1/21 SEPERATE PERMIT REQUIRED FOR DETACHED GARAGE.
 PROVISO ON PLAN SHEET A/B-1. VALUE OF GARAGE, TYPE IIIB
 CONSTR. IS $16,918. ADJUST VALUE OF MAIN DWELLING UNIT
 FROM $250,000.00 TO $233,082.00. ALL FEES ARE PAID. CT

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2021-04-22 Cont ID  
Sent By equinone Date 2021-04-22 Time 14:07 Rev Time 0.00
Received By equinone Date 2021-04-22 Time 10:03 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2021-03-01 Cont ID  
Sent By equinone Date 2021-03-01 Time 16:43 Rev Time 0.00
Received By equinone Date 2021-03-01 Time 15:48 Sent To  
Notes
2021-03-01 16:44:00CODES IN EFFECT
 CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2020 7TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2020
 7TH ED, CHAPTER 1.
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020
 7TH EDITION
 FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2020
 7TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2020 7TH EDITION
 NEC = NFPA 70 2017 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
 FAC = FLORIDA ADMINISTRATIVE CODE
  
 ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 1) GROUNDING ELECTRODE CONDUCTOR FOR DETACHED HOUSE
 PANEL A IS TOO SMALL. IT NEEDS TO BE AT LEAST #2 CU.
 NEC 250.32 AND NEC 250.66
 2) PLEASE PROVIDE AVAILABLE SHORT CIRCUIT CURRENT AT
 METER, SERVICE EQUIPMENT AND PANELS. FBC 107
 3) PROVIDE COMPLIANCE: "NOT LESS THAN 90 PERCENT OF THE
 LAMPS IN PERMANENTLY INSTALLED LUMINAIRES SHALL HAVE AN
 EFFICACY OF AT LEAST 45 LUMENS-PER-WATT OR SHALL
 UTILIZE LAMPS WITH AN EFFICACY OF NOT LESS THAN 65
 LUMENS-PER-WATT?. A NOTE WILL SUFFICE. FBC EC R404.1
 4) ADD NOTE SPECIFYING COMPLIANCE WITH ELECTRICAL AND
 BUILDING CODES LISTED ABOVE.
 END OF COMMENTS.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES
 INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE
 PREVIOUSLY REVIEWED SHEETS.
 CODES IN EFFECT:
  
 IF THE RESUBMITTAL IS NOT PREPARED BY A DESIGN
 PROFESSIONAL (ARCHITECT OR ENGINEER), AND THE PAGES ARE
 11X17 OR SMALLER, YOU MAY RESUBMIT, ALONG WITH A
 COMPLETED RESUBMITTAL FORM, VIA EMAIL TO
 [email protected]. THE EMAIL SHOULD INCLUDE THE PERMIT
 NUMBER AND "RESUBMITTAL" IN THE SUBJECT LINE. THE
 RESUBMITTAL FORM CAN BE FOUND AT THIS WEBSITE:
  
 HTTPS://WWW.WPB.ORG/GOVERNMENT/DEVELOPMENT-SERVICES/FOR
 MS
  
  
 ENRIQUE QUINONEZ P.E.
 ELECTRICAL PLANS EXAMINER
 561-805-6746
 [email protected]
  

Review Stop HIST HISTORICAL
Rev No 2 Status P Date 2021-04-29 Cont ID  
Sent By fmittner Date 2021-04-23 Time 11:01 Rev Time 0.00
Received By fmittner Date 2021-04-29 Time 14:42 Sent To  
Notes
2021-04-28 15:11:03HPB APPROVED.
2021-04-23 11:01:40WAITING ON HPB MEETING 4/27

Review Stop HIST HISTORICAL
Rev No 1 Status F Date 2021-03-26 Cont ID  
Sent By fmittner Date 2021-03-26 Time 16:14 Rev Time 0.00
Received By fmittner Date 2021-03-26 Time 16:14 Sent To  
Notes
2021-03-26 16:15:04NEED COA SUBMITTAL. E-MAILED OWNER.

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2021-04-26 Cont ID  
Sent By rmcphers Date 2021-04-26 Time 16:46 Rev Time 0.00
Received By rmcphers Date 2021-04-12 Time 10:27 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2021-03-27 Cont ID  
Sent By pvalenti Date 2021-03-27 Time 07:52 Rev Time 0.00
Received By pvalenti Date 2021-02-17 Time 08:29 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status P Date 2021-05-11 Cont ID  
Sent By lmarchan Date 2021-05-11 Time 09:52 Rev Time 0.00
Received By lmarchan Date 2021-04-28 Time 16:07 Sent To  
Notes
2021-05-06 16:22:03RECEIPT MU 2021-21645 - $2491.56 - PAID
2021-04-28 16:07:424/28/21 EMAILED IMPACT FOR REVIEW. LEM

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2021-03-01 Cont ID  
Sent By cthroop Date 2021-03-01 Time 16:25 Rev Time 0.00
Received By cthroop Date 2021-03-01 Time 16:25 Sent To  
Notes
2021-03-01 16:25:55PALM BEACH COUNTY IMPACT FEES - DIGITAL SUBMITTALS
  
 PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE
 DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS
 OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST
 FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE
 OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL
 IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME
 THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM
 CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS
 TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF UPON
 APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE RECEIPT TO
 YOUR PROJECT OR EMAIL IT TO [email protected]
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2021-03-03 Cont ID  
Sent By medwards Date 2021-03-03 Time 07:09 Rev Time 0.00
Received By medwards Date 2021-03-03 Time 06:46 Sent To  
Notes
2021-03-03 07:17:43PRIVISO:
  
 THE CONDENSING UNITS MUST BE ANCHORED ACCORDING TO FBC
 RES M1307.2
  
 THE CONDENSATE MUST BE DISPOSED OF ACCORDING TO FBC RES
 M1411.3
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop P PLUMBING
Rev No 2 Status P Date 2021-04-22 Cont ID  
Sent By abelisle Date 2021-04-22 Time 20:50 Rev Time 0.00
Received By abelisle Date 2021-04-22 Time 20:39 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2021-03-01 Cont ID  
Sent By cthroop Date 2021-03-01 Time 16:48 Rev Time 0.00
Received By cthroop Date 2021-03-01 Time 15:07 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status P Date 2021-03-15 Cont ID  
Sent By rmcphers Date 2021-03-15 Time 13:26 Rev Time 0.00
Received By rmcphers Date 2021-03-15 Time 13:26 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2021-04-26 Cont ID  
Sent By rmcphers Date 2021-04-26 Time 16:46 Rev Time 0.00
Received By rmcphers Date 2021-04-26 Time 16:46 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2021-03-03 Cont ID  
Sent By medwards Date 2021-03-03 Time 07:19 Rev Time 0.00
Received By medwards Date 2021-03-03 Time 07:19 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status P Date 2021-04-28 Cont ID  
Sent By fmittner Date 2021-04-23 Time 11:01 Rev Time 0.00
Received By fmittner Date 2021-04-28 Time 15:10 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2021-03-26 Cont ID  
Sent By fmittner Date 2021-03-26 Time 16:15 Rev Time 0.00
Received By fmittner Date 2021-03-26 Time 16:15 Sent To  
Notes
2021-03-26 16:17:22NEEDS A SEPERATE LANDSCAPE PERMIT AND DRIVEWAY NEEDS
 DIMENSIONS.