| Plan Review Stops For Permit 21020360 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2021-06-30 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-06-30 |
Time |
07:58 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-06-30 |
Time |
07:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2021-06-21 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-06-21 |
Time |
14:34 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-06-21 |
Time |
14:34 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2021-04-22 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-04-22 |
Time |
12:58 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-04-22 |
Time |
12:58 |
Sent To |
|
|
| Notes |
| 2021-04-22 13:00:42 | SFR REMODEL | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected] | | | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 | | | AMENDMENTS | | | | | | 2ND REVIEW - NO NEW DRAWINGS OR ROOFING PRODUCT | | | APPROVAL WAS ADDED. | | | | | | CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107 | | | 1) PLEASE SHOW THE REQUIRED EXERIOR WALL WATER BARRIER | | | FBC R703.2 WATER-RESISTIVE BARRIER. | | | ONE LAYER OF NO. 15 ASPHALT FELT, FREE FROM HOLES AND | | | BREAKS, COMPLYING WITH ASTM D226 FOR TYPE 1 FELT OR | | | OTHER APPROVED WATER-RESISTIVE BARRIER SHALL BE APPLIED | | | OVER STUDS OR SHEATHING OF ALL EXTERIOR WALLS. | | | 2) CODE IN EFFECT HAS CHANGED ON 1/1/2021 - PLEASE | | | REVISE THE DRAWINGS TO SHOW THE DESIGN PER THE CODE IN | | | EFFECT (2020 FBC AND ASCE 7-16) | | | 3) ROOF PRODUCT APPROVAL PROVIDED - THE ROOFING SYSTEM | | | CHOSEN HAS A WIND DESIGN PRESSURE OF (-90) - PER 2020 | | | FBC TABLE TABLE R301.2(2) AND TABLE R301.2(3) ROOF ZONE | | | 3 REQUIRES A WIND DESIGN PRESSURE OF (-108.17) THIS | | | SYSTEM CANNOT BE USED UNLESS PROVIDED WITH SITE | | | SPECIFIC WIND DESIGN PRESSURES FROM A QUALIFIED DESIGN | | | PROFESSIONAL THAT SHOW THE WIND DESIGN BELOW THE (-90) | | | - SEE NOTE NUMBER 10 ON THE PRODUCT APPROVAL. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2021-03-18 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-03-18 |
Time |
09:18 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-03-18 |
Time |
08:05 |
Sent To |
|
|
| Notes |
| 2021-03-18 09:18:01 | SFR REMODEL | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected] | | | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 | | | AMENDMENTS | | | | | | CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107 | | | 1) PLEASE SHOW THE REQUIRED EXERIOR WALL WATER BARRIER | | | FBC R703.2 WATER-RESISTIVE BARRIER. | | | ONE LAYER OF NO. 15 ASPHALT FELT, FREE FROM HOLES AND | | | BREAKS, COMPLYING WITH ASTM D226 FOR TYPE 1 FELT OR | | | OTHER APPROVED WATER-RESISTIVE BARRIER SHALL BE APPLIED | | | OVER STUDS OR SHEATHING OF ALL EXTERIOR WALLS. | | | 2) CODE IN EFFECT HAS CHANGED ON 1/1/2021 - PLEASE | | | REVISE THE DRAWINGS TO SHOW THE DESIGN PER THE CODE IN | | | EFFECT (2020 FBC AND ASCE 7-16) | | | 3) ROOF PRODUCT APPROVAL PROVIDED - THE ROOFING SYSTEM | | | CHOSEN HAS A WIND DESIGN PRESSURE OF (-90) - PER 2020 | | | FBC TABLE TABLE R301.2(2) AND TABLE R301.2(3) ROOF ZONE | | | 3 REQUIRES A WIND DESIGN PRESSURE OF (-108.17) THIS | | | SYSTEM CANNOT BE USED UNLESS PROVIDED WITH SITE | | | SPECIFIC WIND DESIGN PRESSURES FROM A QUALIFIED DESIGN | | | PROFESSIONAL THAT SHOW THE WIND DESIGN BELOW THE (-90) | | | - SEE NOTE NUMBER 10 ON THE PRODUCT APPROVAL. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2021-06-28 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2021-06-28 |
Time |
11:25 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2021-06-28 |
Time |
10:42 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2021-06-15 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2021-06-15 |
Time |
13:50 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2021-06-15 |
Time |
13:40 |
Sent To |
|
|
| Notes |
| 2021-06-15 13:54:16 | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | FLORIDA BUILDING CODE 2020 7TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 7TH ED | | | NFPA 70 2017 EDITION | | | | | | JAKE LEAHY BN, BU, PX | | | ELECTRICAL PLANS EXAMINER II | | | 561-805-6713 | | | [email protected] | | | | | | WORK SURFACE COUNTER TOP IN LAUNDRY ROOM REQUIRES | | | OUTLETS PER 210.52(C)(1) | | | | | | 210.52(C)(1) WALL COUNTERTOP AND WORK SURFACE. A | | | RECEPTACLE OUTLET SHALL BE INSTALLED AT EACH WALL | | | COUNTERTOP AND WORK SURFACE THAT IS 300 MM (12 IN.) OR | | | WIDER. RECEPTACLE OUTLETS SHALL BE INSTALLED SO THAT NO | | | POINT ALONG THE WALL LINE IS MORE THAN 600 MM (24 IN.) | | | MEASURED HORIZONTALLY FROM A RECEPTACLE OUTLET IN THAT | | | SPACE. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2021-04-23 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2021-04-23 |
Time |
07:53 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2021-04-23 |
Time |
07:48 |
Sent To |
|
|
| Notes |
| 2021-04-23 07:55:21 | SEE REVIEW NOTES FROM FIRST REVIEW JLEAHY |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2021-03-11 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2021-03-11 |
Time |
09:32 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2021-03-11 |
Time |
09:27 |
Sent To |
|
|
| Notes |
| 2021-03-11 09:36:21 | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | FLORIDA BUILDING CODE 2017 6TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 6TH ED | | | NFPA 70 2014 EDITION | | | | | | JAKE LEAHY BN, BU, PX | | | ELECTRICAL PLANS EXAMINER II | | | 561-805-6713 | | | [email protected] | | | | | | 1) NOTES ON PLANS REFERNCE 2014 NEC THIS PERMIT IS | | | UNDER THE 2017 NEC AND THE 2020FBC, PLEASE CORRECT THE | | | CODE EDITIONS BEING USE. | | | | | | 2) RISER SHOWS TWO PANEL A'S PLEASE CORRECT TO A AND B | | | | | | 3) WIRE SIZES NOT SHOWN TO ONE OF THE PANELS | | | | | | 4) WHICH TAP RULE ARE YOU USING FOR THE FEEDERS? | | | | | | 5) ARC FAULT CIRCUITS ARE REQUIRED IN MORE AREAS THAN | | | NOTED PLEASE CORRECT. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2021-06-30 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-06-30 |
Time |
07:58 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-06-25 |
Time |
13:40 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2021-06-21 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-06-21 |
Time |
14:56 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-06-09 |
Time |
16:24 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2021-04-23 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2021-04-23 |
Time |
07:55 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2021-04-15 |
Time |
11:35 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2021-03-18 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-03-18 |
Time |
09:18 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-03-05 |
Time |
11:26 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2021-06-14 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-06-14 |
Time |
16:07 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-06-14 |
Time |
16:07 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2021-04-20 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-04-20 |
Time |
12:45 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-04-20 |
Time |
12:45 |
Sent To |
|
|
| Notes |
| 2021-04-20 12:45:44 | 1ST REVIEW FBC-2020 MECHANICAL | | | PERMIT-21020360 2ND CYCLE | | | | | | CODES IN EFFECT: | | | | | | FBC B- FLORIDA BUILDING CODE | | | FBC M- FLORIDA MECHANICAL CODE | | | FBC EC- FLORIDA ENERGY CONSERVATION | | | FBC FG- FLORIDA FUEL GAS | | | FBC EX- FLORIDA EXISTING BUILDING CODE | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) A MECHANICAL SUB-PERMIT IS REQUIRED. | | | | | | 2) FS 471.003 (H): THE MECHANICAL EQUIPMENT SIZING | | | CALCULATIONS ALONG WITH THE MECHANICAL SYSTEM DESIGN | | | MUST BE DESIGNED BY A FLORIDA LICENSED ENGINEER OR THE | | | MECHANICAL CONTRACTOR THAT HOLDS THE PERMIT FOR THE | | | SPECIFIC PROJECT WHICH HE OR SHE INSTALLS. | | | PLEASE, HAVE EITHER A LICENSED ENGINEER, PROVIDE A | | | SIGNED AND SEALED MECHANICAL EQUIPMENT SIZING | | | CALCULATION AND A SIGNED AND SEALED MECHANICAL DRAWING, | | | OR | | | THE MECHANICAL CONTRACTOR INSTALLING THE SYSTEM SHALL | | | PROVIDE THE EQUIPMENT SIZING CALCULATIONS AND A CODE | | | COMPLIANT DESIGN. CONTRACTOR SHALL INCLUDE HIS OR HER | | | PRINTED NAME AND SIGNATURE PER 2017 WPB AMENDMENTS TO | | | THE FLORIDA BUILDING CODE, CHAPTER 1, SECTION 107.2.1. | | | FBC 107.2.1 ALL INFORMATION, DRAWINGS, SPECIFICATIONS | | | AND ACCOMPANYING DATA SHALL BEAR THE NAME AND SIGNATURE | | | OF THE PERSON RESPONSIBLE FOR THE DESIGN. | | | 3) PER THE WPB AMENDMENTS TO THE FBC, EACH SHEET OF | | | PLAN (INCLUDING THE SUPPORTING DOCUMENTS) IS REQUIRED | | | TO BE SIGNED AND SEALED BY THE PERSON RESPONSIBLE FOR | | | THE DESIGN. A DIGITAL PLAN REQUIRES A DIGITAL SIGNATURE | | | WITH THE PROPER THIRD PARTY VERIFICATION. PROVIDE | | | CORRECTION. ALTERNATIVELY, A SIGNED/SEALED PAPER SET | | | MAY BE SUPPLIED TO THE BUILDING DEPARTMENT WHEN ALL | | | TRADES ARE APPROVED. WPB FBC 107.1; FS 471/481 | | | | | | | | | THERE IS NO MECHANICAL SUB PERMIT FOR THIS JOB. | | | | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM. | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2021-03-12 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-03-12 |
Time |
06:17 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-03-12 |
Time |
06:03 |
Sent To |
|
|
| Notes |
| 2021-03-12 06:18:06 | 1ST REVIEW FBC-2020 MECHANICAL | | | PERMIT-21020360 | | | | | | CODES IN EFFECT: | | | | | | FBC B- FLORIDA BUILDING CODE | | | FBC M- FLORIDA MECHANICAL CODE | | | FBC EC- FLORIDA ENERGY CONSERVATION | | | FBC FG- FLORIDA FUEL GAS | | | FBC EX- FLORIDA EXISTING BUILDING CODE | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) PLEASE PROVIDE THE ENERGY CALCULATIONS FOR THIS | | | PROJECT. FBC EC 101.5.1.1.2 | | | | | | 2) PLEASE PROVIDE MECHANICAL EQUIPMENT SIZING | | | CALCULATIONS. FBC RES EC R403.7, FBC EC M1401.3 | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE OLD | | | SHEETS FROM THE PLAN SETS, BIND THEM TOGETHER | | | SEPARATELY AND MARK VOID OR OLD ON THEM. PLEASE RETAIN | | | THEM FOR REFERENCE WITH THE NEW SUBMITTED PLANS. THIS | | | PROCESS WILL ALSO APPLY TO ANY DOCUMENTS SUCH AS | | | PRODUCT APPROVALS OR CALCULATIONS BEING REPLACED OR | | | UPDATED. | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2021-03-16 |
|
|
Cont ID |
|
| Sent By |
abelisle |
Date |
2021-03-16 |
Time |
17:22 |
Rev Time |
0.00 |
| Received By |
abelisle |
Date |
2021-03-16 |
Time |
17:22 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
4 |
Status |
P |
Date |
2021-06-30 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-06-30 |
Time |
07:58 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-06-30 |
Time |
07:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
3 |
Status |
N |
Date |
2021-06-21 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-06-21 |
Time |
14:54 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-06-21 |
Time |
14:54 |
Sent To |
|
|
| Notes |
| 2021-06-21 14:54:36 | NO ROOFING SHOWN ON THE DRAWINGS |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
2 |
Status |
F |
Date |
2021-04-22 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-04-22 |
Time |
13:01 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-04-22 |
Time |
13:01 |
Sent To |
|
|
| Notes |
| 2021-04-22 13:01:19 | SEE BUILDING PLAN REVIEW |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2021-03-18 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-03-18 |
Time |
09:18 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-03-18 |
Time |
09:18 |
Sent To |
|
|
| Notes |
| 2021-03-18 09:18:35 | SEE BUILDING PLAN REVIEW |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
P |
Date |
2021-06-10 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-06-10 |
Time |
15:38 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-06-10 |
Time |
15:38 |
Sent To |
|
|
| Notes |
| 2021-06-10 15:44:39 | ORIGINAL SIGNED AND SEALED PAPER DOCUMENTS ROUTED TO | | | STORAGE. ME |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
F |
Date |
2021-04-20 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-04-20 |
Time |
12:45 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-04-20 |
Time |
12:45 |
Sent To |
|
|
| Notes |
| 2021-04-20 12:47:20 | DESIGNER OF DRAWINGS MUST DIGITALLY ISGN AND SEAL OR | | | YOU MAY BRING ORIGINAL SIGNED AND SEALED PAPER DRAWINGS | | | TO OUR OFFICE. | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2021-03-12 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-03-12 |
Time |
06:20 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-03-12 |
Time |
06:20 |
Sent To |
|
|
| Notes |
| 2021-03-12 06:22:15 | THE DRAWINGS APPEAR TO HAVE A COPY OF A SEAL AND | | | SIGNATURE. THE DOCUMENTS WILL NEED TO BE DIGITALLY | | | SIGNED AND SEALED. | | | | | | PER THE WPB AMENDMENTS TO THE FBC, EACH SHEET OF PLAN | | | (INCLUDING THE SUPPORTING DOCUMENTS) IS REQUIRED TO BE | | | SIGNED AND SEALED BY THE PERSON RESPONSIBLE FOR THE | | | DESIGN. A DIGITAL PLAN REQUIRES A DIGITAL SIGNATURE | | | WITH THE PROPER THIRD PARTY VERIFICATION. PROVIDE | | | CORRECTION. ALTERNATIVELY, A SIGNED/SEALED PAPER SET | | | MAY BE SUPPLIED TO THE BUILDING DEPARTMENT WHEN ALL | | | TRADES ARE APPROVED. WPB FBC 107.1; FS 471/481 | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|