Plan Review Details - Permit 21020261
Plan Review Stops For Permit 21020261
Review Stop E ELECTRICAL
Rev No 2 Status P Date 2021-03-22 Cont ID  
Sent By ppetty Date 2021-03-22 Time 09:19 Rev Time 0.00
Received By ppetty Date 2021-03-22 Time 08:59 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2021-02-18 Cont ID  
Sent By ppetty Date 2021-02-18 Time 12:31 Rev Time 0.00
Received By ppetty Date 2021-02-18 Time 12:31 Sent To  
Notes
2021-02-18 12:32:12PLEASE SEE F/D NOTES

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2021-03-12 Cont ID  
Sent By pleduc Date 2021-03-12 Time   Rev Time 0.00
Received By pleduc Date 2021-03-12 Time 13:59 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2021-02-16 Cont ID  
Sent By pleduc Date 2021-02-16 Time   Rev Time 0.00
Received By pleduc Date 2021-02-16 Time 14:32 Sent To  
Notes
2021-02-16 15:01:17THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE
 MARSHAL, WITH THE FOLLOWING COMMENTS:
  
  
 1) SHEET FA 1 - THERE ARE INDICATIONS OF CIRCUITS AND
 DEVICES ARE CLASS B.
  
 PLEASE REVIEW AND EXPLAIN WHAT HAPPENS IF A BREAK
 OCCURS, DO THE DEVICES DOWN LINE CONTINUE TO FUNCTION
 OR DOES IT SIMPLY GO TO TROUBLE?
  
 IT IS IMPERAIVE IN A HIGH RISE BUILDING THAT THE FA
 DEVICES ARE CLASS A OR THAT NO DEVICE IS NOT FUNCTIONAL
 DUE TO A BREAK OR TROUBLE?
  
  
  
 2) THERE ARE INDICATIONS OF TWO NFPA 72 CODE REFERENCES
 THAT DO NOT APPEAR TO BE RELATED TO THE INTENT.
  
 UNDER EXISTING POWER SUPPLY #N8 IT STATES REQUIRED
 OPERATION TIME FROM NFPA 72 10.2.6.2.2 & 10.5.6.3.1.
  
 I AM NOT SURE WHAT CODE EDITION IT IS CITING BUT NFPA
 72 2013 , DOES NOT HAVE THOSE REFERENCES.
  
 PLEASE REVIEW AND CORRECT.
  
  
  
 3) THERE ARE INDICATIONS OF TWO NFPA 72 CODE REFERENCES
 THAT DO NOT APPEAR TO BE RELATED TO THE INTENT.
  
 UNDER EXISTING NFS - 3030 FACP IT STATES REQUIRED
 OPERATION TIME FROM NFPA 72 4.4.1.5.2.2(1) &
 4.4.1.5.3.1
  
 I AM NOT SURE WHAT CODE EDITION IT IS CITING BUT NFPA
 72 2013 , DOES NOT HAVE THOSE REFERENCES.
  
 PLEASE REVIEW AND CORRECT.
  
  
 4) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET
 REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE
 ABOVE.
  
  
 5) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE
 RE-SUBMITTAL OF THE ABOVE.
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2021-03-25 Cont ID  
Sent By medwards Date 2021-03-25 Time 11:17 Rev Time 0.00
Received By medwards Date 2021-03-11 Time 07:16 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2021-02-26 Cont ID  
Sent By medwards Date 2021-02-26 Time 11:20 Rev Time 0.00
Received By medwards Date 2021-02-12 Time 14:04 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2021-03-25 Cont ID  
Sent By medwards Date 2021-03-25 Time 11:17 Rev Time 0.00
Received By medwards Date 2021-03-25 Time 11:13 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2021-02-26 Cont ID  
Sent By medwards Date 2021-02-26 Time 11:18 Rev Time 0.00
Received By medwards Date 2021-02-26 Time 11:06 Sent To  
Notes
2021-02-26 11:18:48SEE FIRE REVIEWERS NOTES.
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2021-03-25 Cont ID  
Sent By medwards Date 2021-03-25 Time 11:17 Rev Time 0.00
Received By medwards Date 2021-03-25 Time 11:17 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2021-02-26 Cont ID  
Sent By medwards Date 2021-02-26 Time 11:19 Rev Time 0.00
Received By medwards Date 2021-02-26 Time 11:19 Sent To  
Notes
***NONE***