| Plan Review Stops For Permit 21020260 |
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2021-05-13 |
|
|
Cont ID |
|
| Sent By |
equinone |
Date |
2021-05-13 |
Time |
07:57 |
Rev Time |
0.00 |
| Received By |
equinone |
Date |
2021-05-13 |
Time |
07:57 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2021-03-16 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2021-03-16 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2021-03-16 |
Time |
11:31 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2021-02-10 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2021-02-10 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2021-02-10 |
Time |
10:16 |
Sent To |
|
|
| Notes |
| 2021-02-10 11:01:00 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | | | | 1) SHEET FA 2 - THERE ARE INDICATIONS OF CIRCUITS AND | | | DEVICES ARE CLASS B. | | | | | | PLEASE REVIEW AND EXPLAIN WHAT HAPPENS IF A BREAK | | | OCCURS, DO THE DEVICES DOWN LINE CONTINUE TO FUNCTION | | | OR DOES IT SIMPLY GO TO TROUBLE? | | | | | | IT IS IMPERAIVE IN A HIGH RISE BUILDING THAT THE FA | | | DEVICES ARE CLASS A OR THAT NO DEVICE IS NOT FUNCTIONAL | | | DUE TO A BREAK OR TROUBLE? | | | | | | | | | | | | 2) THERE ARE INDICATIONS OF TWO NFPA 72 CODE NUMBER | | | THAT DO NOT APPEAR TO BE RELATED TO THE INTENT. | | | | | | UNDER EXISTING POWER SUPPLY #N8 IT STATES REQUIRED | | | OPERATION TIME FROM NFPA 72 10.2.6.2.2 & 10.5.6.3.1. | | | | | | I AM NOT SURE WHAT CODE EDITION IT IS CITING BUT NFPA | | | 72 2013 , DOES NOT HAVE THOSE REFERENCES. | | | | | | PLEASE REVIEW AND CORRECT. | | | | | | | | | | | | 3) THERE ARE INDICATIONS OF TWO NFPA 72 CODE REFERENCES | | | THAT DO NOT APPEAR TO BE RELATED TO THE INTENT. | | | | | | UNDER EXISTING NFS - 3030 FACP IT STATES REQUIRED | | | OPERATION TIME FROM NFPA 72 4.4.1.5.2.2(1) & | | | 4.4.1.5.3.1 | | | | | | I AM NOT SURE WHAT CODE EDITION IT IS CITING BUT NFPA | | | 72 2013 , DOES NOT HAVE THOSE REFERENCES. | | | | | | PLEASE REVIEW AND CORRECT. | | | | | | | | | | | | 4) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET | | | REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE | | | ABOVE. | | | | | | | | | | | | 5) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE | | | RE-SUBMITTAL OF THE ABOVE. | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2021-05-13 |
|
|
Cont ID |
|
| Sent By |
equinone |
Date |
2021-05-13 |
Time |
07:59 |
Rev Time |
0.00 |
| Received By |
equinone |
Date |
2021-04-23 |
Time |
10:03 |
Sent To |
|
|
| Notes |
| 2021-04-27 18:18:01 | TO BLDG DIV AUDIT | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2021-04-10 |
Time |
|
Rev Time |
0.00 |
| Received By |
aoliver |
Date |
2021-04-08 |
Time |
11:48 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2021-03-22 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2021-03-22 |
Time |
10:14 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2021-03-17 |
Time |
15:14 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2021-03-17 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-03-17 |
Time |
07:09 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-03-15 |
Time |
17:37 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2021-02-13 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2021-02-13 |
Time |
06:04 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2021-02-05 |
Time |
00:18 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2021-05-13 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-05-13 |
Time |
06:43 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-05-13 |
Time |
06:26 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
PRIVATEPRV |
PRIVATE PROVIDER DOCUMENTS |
| Rev No |
4 |
Status |
P |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2021-04-27 |
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
2021-04-27 |
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
PRIVATEPRV |
PRIVATE PROVIDER DOCUMENTS |
| Rev No |
3 |
Status |
F |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2021-04-10 |
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
2021-04-10 |
Time |
|
Sent To |
|
|
| Notes |
| 2021-04-10 14:57:57 | 1. FS553.791, THE AFFIDAVIT IS FOR PERMIT 21020260, | | | SUITE 1010. PERMIT APPLICATION 21020260 IS FOR SUITE | | | 1030. | | | | | | 2. FS553.791, THE AFFIDAVIT INCLUDES PAGE FA1, BUT TWO | | | PAGES WERE UPLAODED, FA1 AND FA2. | | | | | | DETERMINE WHAT DOCUMENTS ARE REQUIRED FOR THIS PERMIT, | | | CORRELATE PLANS UPLOADED WITH PLANS REVIEWED BY PRIVATE | | | PROVIDER, REVISE AFFIDAVIT ACCORDINGLY. | | | | | | |
|
|
| Review Stop |
PRIVATEPRV |
PRIVATE PROVIDER DOCUMENTS |
| Rev No |
2 |
Status |
F |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2021-03-19 |
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
2021-03-19 |
Time |
|
Sent To |
|
|
| Notes |
| 2021-03-19 17:48:00 | PLAN REVIEW AFFIDAVIT DOES NOT INCLUDE SUPPORTING | | | DOCUMENTS WHICH ARE A PART OF THIS PERMIT SUBMITTAL | | | |
|
|
| Review Stop |
PRIVATEPRV |
PRIVATE PROVIDER DOCUMENTS |
| Rev No |
1 |
Status |
F |
Date |
2021-02-12 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2021-02-12 |
Time |
08:27 |
Rev Time |
0.00 |
| Received By |
rgathrig |
Date |
2021-02-12 |
Time |
08:26 |
Sent To |
|
|
| Notes |
| 2021-02-12 08:27:31 | THE PRIVATE PROVIDER REVIEW IS FAILED | | | THIS INTERIOR BUILDOUT IS PRIVATE PROVIDER PLAN REVIEW | | | THE AFFIDAVITS FOR PLAN REVIEW CODE COMPLIANCE DOES NOT | | | MENTION THESE DOCUMENTS AND | | | AN AFFIDAVIT FOR THIS SCOPE OF WORK IS NOT INCLUDED | | | WITH THIS SUBMITTAL | | | PLEASE PROVIDE AFFIDAVITS FROM PRIVATE PROVIDER | | | RICHARD GATHRIGHT | | | ASSISTANT BUILDING OFFICIAL | | | 561 805 6679 | | | | | 2021-02-11 18:44:26 | | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2021-03-17 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-03-17 |
Time |
07:09 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-03-17 |
Time |
07:09 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
N |
Date |
2021-02-13 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2021-02-13 |
Time |
06:04 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2021-02-13 |
Time |
06:03 |
Sent To |
|
|
| Notes |
| 2021-02-13 06:04:41 | FA PLANS ARE SIGNED BY ELEC CONTRACTOR | | | |
|
|