| Plan Review Stops For Permit 21020238 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2021-07-21 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2021-07-21 |
Time |
16:35 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2021-07-21 |
Time |
16:20 |
Sent To |
|
|
| Notes |
| 2021-07-21 16:39:22 | ****CORRECTIONS**** | | | | | | PETER E VALENTI | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6673 | | | | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | BUILDING REVIEW APPROVED WITH PROVISO: | | | | | | AT TIME OF INSPECTION, FOR THE REINFORCEMENT OF THE | | | STEEL ROOF FRAMING, THE CONTRACTOR IS REQUIRED TO | | | PROVIDE: | | | | | | 1) WELD PROCEDURE SPECIFICATIONS | | | 2) QUALIFICATION OF WELDING PERSONNEL |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
F |
Date |
2021-07-09 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2021-07-09 |
Time |
08:48 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2021-07-09 |
Time |
06:34 |
Sent To |
|
|
| Notes |
| 2021-07-09 09:06:21 | ****CORRECTIONS**** | | | | | | PETER E VALENTI | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6673 | | | | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | BUILDING REVIEW DENIED: | | | | | | FBC B 107, PLEASE RESUBMIT THE FOLLOWING SHOP DRAWING | | | PAGES: RF-1 FROM TITAN WELDING (XUAN CHEN P.E.) & | | | 21058-1 FROM SRM (SAMUEL MARTIN P.E.) WITH THE REVIEW | | | STAMP APPROVALS FROM CURRENT ENGINEER OF RECORD (JASON | | | D. BARBER P.E.). |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2021-04-21 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2021-04-21 |
Time |
14:36 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2021-04-20 |
Time |
13:38 |
Sent To |
|
|
| Notes |
| 2021-04-21 14:50:45 | PETER E VALENTI | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6673 | | | | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | BUILDING REVIEW DENIED: | | | | | | FBC B 107.2.1, PLEASE PROVIDE MORE INFORMATION FOR THE | | | NEW OUTSIDE AIR ROOF TOP UNITS. THE SUBMITTED SHOP | | | DRAWING RF-1 SIGNED & SEALED BY XUAN CHEN P.E. DOES NOT | | | INCLUDE THE (2) OUTSIDE AIR UNITS(OARTU1 & OARTU2). | | | | | | ALSO, PLEASE CLARIFY THE NOTE FOR OPERATING WEIGHT | | | POUNDS FROM WITHIN THE 100% OA PACKAGED ROOFTOP A/C | | | EQUIPMENT SCHEDULE ON SHEET M6-1. DOES THIS NUMBER | | | (4,450) REPRESENT THE WEIGHT OF EACH UNIT OR A COMBINED | | | TOTALWEIGHT. | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2021-03-24 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2021-03-24 |
Time |
14:23 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2021-03-24 |
Time |
11:28 |
Sent To |
|
|
| Notes |
| 2021-03-24 14:26:13 | ****CORRECTIONS**** | | | PETER E VALENTI | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6673 | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | BUILDING REVIEW DENIED: | | | | | | FBC B 107.2, PLEASE PROVIDE ENGINEER APPROVED | | | STRUCTURAL ROOF DECK INFORMATION INCLUDING PROPOSED | | | EQUIPMENT LOCATION AND CONNECTION DETAILS SUCH AS | | | REINFORCEMENT OF ROOF FRAMING IF NECESSARY AND WINDLOAD | | | RESISTANCE, AS THERE ARE NO ARCHITECTURAL OR STRUCTURAL | | | SUBMITTED SHEETS. | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2021-02-26 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2021-02-26 |
Time |
09:33 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2021-02-26 |
Time |
08:53 |
Sent To |
|
|
| Notes |
| 2021-02-26 09:48:52 | ****CORRECTIONS**** | | | | | | PETER E VALENTI | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6673 | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | BUILDING REVIEW DENIED: | | | | | | FBC B 107.2, PLEASE PROVIDE ENGINEER APPROVED | | | STRUCTURAL ROOF DECK INFORMATION INCLUDING PROPOSED | | | EQUIPMENT LOCATION AND CONNECTION DETAILS SUCH AS | | | REINFORCEMENT OF ROOF FRAMING IF NECESSARY AND WINDLOAD | | | RESISTANCE, AS THERE ARE NO ARCHITECTURAL OR STRUCTURAL | | | SUBMITTED SHEETS. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
P |
Date |
2021-07-21 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2021-07-21 |
Time |
16:33 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2021-07-21 |
Time |
16:33 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2021-07-08 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2021-07-08 |
Time |
14:19 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2021-07-08 |
Time |
14:15 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2021-04-09 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2021-04-09 |
Time |
08:04 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2021-04-09 |
Time |
07:40 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2021-03-16 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2021-03-16 |
Time |
14:48 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2021-03-16 |
Time |
14:45 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2021-02-25 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2021-02-25 |
Time |
15:24 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2021-02-24 |
Time |
16:31 |
Sent To |
|
|
| Notes |
| 2021-02-25 15:27:30 | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | FLORIDA BUILDING CODE 2020 7TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 7TH ED | | | NFPA 70 2017 EDITION | | | | | | JAKE LEAHY BN, BU, PX | | | ELECTRICAL PLANS EXAMINER II | | | 561-805-6713 | | | [email protected] | | | | | | PANEL B IS TO BE INSTALLED IN AN CLASSIFIED AREA PLEASE | | | INDICATE ON THE PLANS THE AREA OF CLASSIFICATION IN | | | RELATION TO THE PANEL. NEC 501,502, 511 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2021-07-21 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2021-07-21 |
Time |
16:40 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2021-07-14 |
Time |
10:18 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2021-07-12 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-07-12 |
Time |
13:09 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-07-06 |
Time |
11:24 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2021-04-21 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2021-04-21 |
Time |
14:50 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2021-04-06 |
Time |
11:03 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2021-03-24 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2021-03-24 |
Time |
14:26 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2021-03-12 |
Time |
15:49 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2021-02-26 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2021-02-26 |
Time |
09:48 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2021-02-18 |
Time |
08:13 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
5 |
Status |
P |
Date |
2021-07-19 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-07-19 |
Time |
15:03 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-07-19 |
Time |
15:02 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
F |
Date |
2021-07-09 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-07-09 |
Time |
07:49 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-07-09 |
Time |
07:49 |
Sent To |
|
|
| Notes |
| 2021-07-09 07:49:59 | 1ST REVIEW FBC-2020 MECHANICAL | | | PERMIT-21020238 | | | | | | CODES IN EFFECT: | | | | | | FBC B- FLORIDA BUILDING CODE | | | FBC M- FLORIDA MECHANICAL CODE | | | FBC EC- FLORIDA ENERGY CONSERVATION | | | FBC FG- FLORIDA FUEL GAS | | | FBC EX- FLORIDA EXISTING BUILDING CODE | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) PLEASE NOTE THAT THIS PROJECT IS UNDER THE 2020 | | | FLORIDA BUILDING CODE. | | | | | | 2) THE NEW DESIGNER OF RECORD NEEDS TO PROVIDE THE | | | MECHANICAL EQUIPMENT SIZING CALCULATIONS BASED ON THIS | | | NEW DESIGN. FBC EC C403.2.1 | | | | | | 3) THE NEW DESIGNER OF RECORD NEEDS TO PROVIDE THE | | | ENERGY CALCULATIONS. FBC EC C402 | | | | | | 4) PLEASE PROVIDE AN UPDATED SHEET FA0.1 WITH THE NEW | | | DESIGNER?S DIGITAL SIGNATURE. FBC 107.2.1 | | | | | | 5) PLEASE PROVIDE AN UPDATED SHEET FA2.1 WITH THE NEW | | | DESIGNER?S DIGITAL SIGNATURE. FBC 107.2.1 | | | | | | 6) PLEASE PROVIDE AN UPDATED SHEET FA2-1 WITH THE NEW | | | DESIGNER?S DIGITAL SIGNATURE. FBC 107.2.1 | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM. | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2021-04-08 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-04-08 |
Time |
16:03 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-04-08 |
Time |
16:00 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2021-03-15 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-03-15 |
Time |
14:59 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-03-15 |
Time |
14:59 |
Sent To |
|
|
| Notes |
| 2021-03-15 15:00:43 | 2ND REVIEW FBC-2020 MECHANICAL | | | PERMIT-21020238 | | | | | | CODES IN EFFECT: | | | | | | FBC B- FLORIDA BUILDING CODE | | | FBC M- FLORIDA MECHANICAL CODE | | | FBC EC- FLORIDA ENERGY CONSERVATION | | | FBC FG- FLORIDA FUEL GAS | | | FBC EX- FLORIDA EXISTING BUILDING CODE | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) TABLE 403.3.1.1 OF THE FBC M ONLY ADDRESSES EXHAUST | | | IN REPAIR GARAGES. THE MINIMUM REQUIRED EXHAUST RATE | | | FOR A REPAIR GARAGE IS .75 CFM X SQ.FT. OF THE SPACE. | | | THE SYSTEM YOU ARE PROPOSING IS MORE IN LINE OF AN | | | ENCLOSED PARKING GARAGE. THESE ARE 2 VERY DIFFERENT | | | OCCUPANCIES, A PARKING GARAGE VENTILATION IS NOT | | | DESIGNED WITH PEOPLE BEING INSIDE THIS SPACE FOR AN 8 | | | HOUR SHIFT. THE EXHAUST VENTILATION CALCULATION FOR A | | | REPAIR GARAGE DOES TAKE THIS INTO CONSIDERATION. THIS | | | DESIGN FOR CONDITIONING THIS REPAIR GARAGE DOES NOT | | | SHOW THE REQUIRED EXHAUST AIR OF 5160 CFM. I WOULD | | | SUGGEST AN AHU WITH 100% OUTDOOR AIR WHICH WOULD NEED | | | TO BRING IN THE 5160 CFM AND RETURN OUTDOORS THE 5160 | | | CFM. SECTION 401.3 OF THE FBCM STATES VENTILATION SHALL | | | BE PROVIDED DURING THE PERIODS THAT THE ROOM OR SPACE | | | IS OCCUPIED. TABLE 403.3.1.1 OF THE FBC M SPECIFIES | | | THAT THE 6180 SQ FT X .75 = 5,160 CFM OF EXHAUST AIR | | | WHILE THE SPACE IS OCCUPIED. | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE OLD | | | SHEETS FROM THE PLAN SETS, BIND THEM TOGETHER | | | SEPARATELY AND MARK VOID OR OLD ON THEM. PLEASE RETAIN | | | THEM FOR REFERENCE WITH THE NEW SUBMITTED PLANS. THIS | | | PROCESS WILL ALSO APPLY TO ANY DOCUMENTS SUCH AS | | | PRODUCT APPROVALS OR CALCULATIONS BEING REPLACED OR | | | UPDATED. | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2021-02-26 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-02-26 |
Time |
08:19 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-02-25 |
Time |
15:55 |
Sent To |
|
|
| Notes |
| 2021-02-26 08:19:24 | 1ST REVIEW FBC-2020 MECHANICAL | | | PERMIT-21020238 | | | | | | CODES IN EFFECT: | | | | | | FBC B- FLORIDA BUILDING CODE | | | FBC M- FLORIDA MECHANICAL CODE | | | FBC EC- FLORIDA ENERGY CONSERVATION | | | FBC FG- FLORIDA FUEL GAS | | | FBC EX- FLORIDA EXISTING BUILDING CODE | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | | | | 1) THE ADDRESS ON THE ENERGY GAUGE REPORT DOES NOT | | | MATCH THE ADDRESS ON THE PERMIT APPLICATION. PLEASE | | | SUBMIT AN ENERGY GAUGE REPORT FOR THE ADDRESS OF THE | | | PROJECT. FBC 107.2.1 | | | | | | 2) PLEASE SHOW THAT THIS REPAIR GARAGE WILL MEET TABLE | | | 403.3.1.1 OF THE FBC M FOR THE .75 CFM/SQ.FT. EXHAUST | | | AIRFLOW RATE. | | | | | | 3) SHEET M7-1 SHOWS A GREENHECK/EVH-660D LOUVER, PLEASE | | | SHOW THE LOCATION OF THIS LOUVER ON SHEET M2-1. FBC | | | 107.2.1 | | | | | | 4) PLEASE PROVIDE THE NOA FOR THE GREENHECK/EVH-660D | | | LOUVER. FBC 107.2.1 | | | | | | 5) PLEASE PROVIDE THE NOA FOR THE ROOF MOUNTED EXH. FAN | | | FBC 107.2.1 | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE OLD | | | SHEETS FROM THE PLAN SETS, BIND THEM TOGETHER | | | SEPARATELY AND MARK VOID OR OLD ON THEM. PLEASE RETAIN | | | THEM FOR REFERENCE WITH THE NEW SUBMITTED PLANS. THIS | | | PROCESS WILL ALSO APPLY TO ANY DOCUMENTS SUCH AS | | | PRODUCT APPROVALS OR CALCULATIONS BEING REPLACED OR | | | UPDATED. | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
5 |
Status |
P |
Date |
2021-07-20 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-07-19 |
Time |
15:05 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-07-19 |
Time |
15:05 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
4 |
Status |
P |
Date |
2021-07-09 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-07-09 |
Time |
07:54 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-07-09 |
Time |
07:54 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
P |
Date |
2021-04-09 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2021-04-09 |
Time |
08:04 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2021-04-09 |
Time |
08:04 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2021-03-15 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-03-15 |
Time |
15:06 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-03-15 |
Time |
15:06 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2021-02-26 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-02-26 |
Time |
08:35 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-02-26 |
Time |
08:35 |
Sent To |
|
|
| Notes |
|
|