| 2021-09-04 08:59:40 | BUILDING PLAN REVIEW |
| | |
| | CHRISTOPHER S. THROOP, C.B.O., CFM |
| | PLANS EXAMINER II PX3169/RPX306 |
| | INSPECTOR BN4338 |
| | BUILDING OFFICIAL BU1635 |
| | ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935 |
| | DEVELOPMENT SERVICES DEPARTMENT |
| | CITY OF WEST PALM BEACH |
| | (561) 805-6726 |
| | [email protected] |
| | |
| | CODES IN EFFECT: |
| | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST |
| | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, |
| | CHAPTER 1 ADMINISTRATION |
| | 2017 NEC |
| | |
| | 3RD REVIEW |
| | |
| | RESULTS: DENIED |
| | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT |
| | |
| | SOW: INSTALL NON-IMPACT RATED WINDOWS. SHUTTER PANEL |
| | PRODUCT APPROVAL AND SHUTTER SCHEDULE SUBMITTED FOR |
| | REVIEW. |
| | |
| | 1. STORM PANEL NOA NO. 17-0925.04 AND PRODUCT APPROVAL |
| | FL 11968-R5 HAVE BEEN SUBMITTED FOR REVIEW. |
| | TWO PRODUCT COMPLIANCE REPORTS ARE NOT REQUIRED. REMOVE |
| | EITHER THE NOA OR PRODUCT APPROVAL. |
| | 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS |
| | SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH |
| | 107.2.5. |
| | |
| | 2. DESIGNER SHALL HIGHLIGHT CONNECTION TYPE, ANCHOR |
| | TYPE AND SPACING ON STORM PANEL NOA OR PRODUCT |
| | APPROVAL. |
| | FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE |
| | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED |
| | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. |
| | |
| | |
| | REF. SHUTTER SCHEDULE FOR THE FOLLOWING COMMENTS: |
| | |
| | 3. PRODUCT COMPLIANCE REPORTS ARE INDICATED AS FL419 |
| | AND NOA NO. 15-07142.22. THESE REPORTS HAVE NOT BEEN |
| | SUBMITTED FOR REVIEW. |
| | FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE |
| | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED |
| | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. |
| | |
| | 4. WALL PRESSURE DATA IS MISSING. |
| | 5. SHUTTER MOUNTING CONNECTION TYPE IS INDICATED AS |
| | ANCHOR BOLOTS. DESIGNER SHALL HIGHLIGHT THE CONNECTION |
| | TYPE FROM THE SELECTED AND REVIEWED PRODUCT APPROVAL. |
| | 6. SHUTTER GLASS SEPERATION INDICATED AS 4". DESIGNER |
| | SHALL HIGHLIGHT THIS ON PRODUCT APPROVAL. |
| | 7. SHUTTER SPANS ARE LESS THAN SHUTTER HEIGHT. SHUTTERS |
| | ARE INSTALLED VERTICALLY. SHUTTER SPAN CANNOT BE LESS |
| | THAN SHUTTER HEIGHT PLUS ANCHOR BOLT EDGE DISTANCE. |
| | 8. MINIMUM EDGE DISTANCE. DESIGNER SHALL HIGHLIGHT |
| | THESE ON PRODUCT APPROVAL. |
| | 9. ANCHOR SPACING. DESIGNER SHALL HIGHLIGHT THESE ON |
| | PRODUCT APPROVAL. |
| | 10. ANCHOR TYPE IS INDICATED AS PANEL MATE. ANCHORS |
| | SHALL BE SPECIFIC PER NOTE # 1 ON SHUTTER SCHEDULE. |
| | DESIGNER SHALL HIGHLIGHT THESE ON PRODUCT APPROVAL. |
| | 11. CENTER BOLTS OR RE-INFORCING. ENTER EITHER YES OR |
| | NO AND HIGHLIGHT ON PRODUCT APPROVAL. |
| | 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS |
| | SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH |
| | 107.2.5. |
| | |
| | 12. INCREASE VALUE BASED ON THE ADDITIONAL SOW. (STORM |
| | PANELS) |
| | CITY OF WPB CHPT109.3 BUILDING PERMIT VALUATIONS. |
| | |
| | 1A. VALUE APPEARS LOW FOR THE PROPOSED SCOPE OF WORK. |
| | 1B. THE PERMIT VALUATION AND PERMIT FEE MUST BE |
| | COMMENSURATE WITH THE VALUATION AND FEE THAT A LICENSED |
| | CONTRACTOR WOULD PROVIDE. THIS INCLUDES ALL LABOR, |
| | MATERIALS AND RENTALS OF EQUIPMENT TO PERFORM THE SCOPE |
| | OF WORK. |
| | 1C. YOU MAY PROVIDE A COPY OF THE CONTRACT SIGNED BY |
| | THE OWNER OR A LIST OF LABOR, MATERIALS AND EQUIPMENT |
| | RENTAL TO VERIFY VALUE. |
| | FINAL BUILDING PERMIT VALUATION SHALL BE SET BY THE |
| | BUILDING OFFICIAL |
| | |
| | |
| | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED |
| | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. |
| | |
| | WHEN RESUBMITING, IT IS HELPFUL TO PROVIDE A RESPONSE |
| | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY |
| | RE-SUBMITTAL FORM. |
| | |
| | |
| | |
| | |