Plan Review Details - Permit 21020139
Plan Review Stops For Permit 21020139
Review Stop E ELECTRICAL
Rev No 2 Status P Date 2021-03-02 Cont ID  
Sent By equinone Date 2021-03-02 Time 16:06 Rev Time 0.00
Received By equinone Date 2021-03-02 Time 16:05 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2021-02-19 Cont ID  
Sent By jleahy Date 2021-02-19 Time 09:37 Rev Time 0.00
Received By equinone Date 2021-02-18 Time 16:22 Sent To  
Notes
2021-02-19 09:38:17CODES IN EFFECT
 CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2020 7TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2020
 7TH ED, CHAPTER 1.
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020
 7TH EDITION
 FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2020
 7TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2020 7TH EDITION
 NEC = NFPA 70 2017 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
 FAC = FLORIDA ADMINISTRATIVE CODE
  
 ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 IT SEEMS THERE ARE SOME INCONSISTENCIES BETWEEN RISER
 DIAGRAM AND PANEL SCHEDULES THAT NEED CLARIFICATION OR
 CORRECTIONS
  
 1) RAYCAP BREAKER PANEL SCHEDULE SHOWS ONE 60 AMPS MAIN
 BREAKER BUT POWER PANEL BREAKER SCHEDULE SHOWS TWO 30
 AMPS BREAKERS FOR RAYCAP FEEDERS. PLEASE CLARIFY AND
 CORRECT AS NEEDED.
 2) RISER DIAGRAM SHOWS ONE RAYCAP PANEL, BUT POWER
 PANEL BREAKER SCHEDULE SHOWS TWO 30 AMPS RAYCAP
 FEEDERS. POWER PANEL BREAKER LISTS THE TWO CIRCUITS AS
 ONE POLE BREAKER, BUT RISER APPEARS TO INDICATE THAT IS
 ONE CIRCUIT WITH A 2-POLE BREAKER. PLEASE CLARIFY AND
 CORRECT AS NEEDED.
 3) RISER DIAGRAM, NOTE 2, SHOWS 1#3-10 SEOW CONDUCTOR
 FOR RAYCAP PANEL. DOES THIS MEAN 2#3 + 1#10 G OR DOES
 IT MEAN 2#10 + 1#10 G CONDUCTORS? PLEASE CLARIFY AND
 CORRECT AS NEEDED.
 4) RISER DIAGRAM SHOWS THREE CIRCUITS FROM RAYCAP PANEL
 TO THREE POWER SUPPLIES. PLEASE INCLUDE THESE CIRCUITS
 IN RAYCAP PANEL SCHEDULE
 5) PLEASE PROVIDE AVAILABLE FAULT CURRENT AT SERVICE
 EQUIPMENT AND MAIN SERVICE POWER PANEL
 6) PLEASE SPECIFY AIC RATINGS FOR MAIN PANEL AND RAYCAP
 PANEL
  
 END OF COMMENTS.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES
 INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE
 PREVIOUSLY REVIEWED SHEETS.
 CODES IN EFFECT:
  
 IF THE RESUBMITTAL IS NOT PREPARED BY A DESIGN
 PROFESSIONAL (ARCHITECT OR ENGINEER), AND THE PAGES ARE
 11X17 OR SMALLER, YOU MAY RESUBMIT, ALONG WITH A
 COMPLETED RESUBMITTAL FORM, VIA EMAIL TO
 [email protected]. THE EMAIL SHOULD INCLUDE THE PERMIT
 NUMBER AND "RESUBMITTAL" IN THE SUBJECT LINE. THE
 RESUBMITTAL FORM CAN BE FOUND AT THIS WEBSITE:
  
 HTTPS://WWW.WPB.ORG/GOVERNMENT/DEVELOPMENT-SERVICES/FOR
 MS
  
 ENRIQUE QUINONEZ P.E.
 ELECTRICAL PLANS EXAMINER
 561-805-6746
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2021-03-02 Cont ID  
Sent By equinone Date 2021-03-02 Time 16:06 Rev Time 0.00
Received By equinone Date 2021-03-01 Time 14:10 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2021-02-19 Cont ID  
Sent By equinone Date 2021-02-19 Time 09:39 Rev Time 0.00
Received By equinone Date 2021-02-05 Time 16:15 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2021-03-02 Cont ID  
Sent By equinone Date 2021-03-02 Time 16:06 Rev Time 0.00
Received By equinone Date 2021-03-02 Time 16:06 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2021-02-19 Cont ID  
Sent By equinone Date 2021-02-19 Time 09:39 Rev Time 0.00
Received By equinone Date 2021-02-19 Time 09:39 Sent To  
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved