Plan Review Details - Permit 21020115
Plan Review Stops For Permit 21020115
Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 3 Status P Date 2021-06-28 Cont ID  
Sent By jwitmer Date 2021-06-28 Time 09:08 Rev Time 0.00
Received By jwitmer Date 2021-06-28 Time 09:03 Sent To  
Notes
***NONE***

Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 2 Status F Date 2021-06-02 Cont ID  
Sent By jwitmer Date 2021-06-02 Time 09:01 Rev Time 0.00
Received By jwitmer Date 2021-06-02 Time 07:59 Sent To  
Notes
2021-06-02 09:01:53TO THE BUILDING CONTRACTOR:
 PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE
 CONTRACTOR, ON LETTERHEAD, STATING THAT THE
 INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM
 COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH
 COUNTY WILL BE FOLLOWED, AND THAT NOTIFICATION WILL BE
 GIVEN TIMELY. ADDITIONAL INFORMATION REGARDING ASBESTOS
 REQUIREMENTS CAN BE FOUND ON THEIR WEBSITE:
  
 HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE
 S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION-
 RENOVATION.HTML
  
 THE CONTRACTOR ACKNOWLEDGEMENT CAN BE SENT VIA EMAIL TO
 [email protected]. THE INFORMATION SHOULD BE IN PDF
 FORMAT AS AN ATTACHMENT TO THE EMAIL. PLEASE INCLUDE
 THE PERMIT NUMBER AND "ASBESTOS" IN THE SUBJECT LINE.
  

Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 1 Status F Date 2021-02-09 Cont ID  
Sent By jwitmer Date 2021-02-09 Time 15:45 Rev Time 0.00
Received By jwitmer Date 2021-02-09 Time 14:17 Sent To  
Notes
2021-02-09 15:44:58TO THE BUILDING CONTRACTOR:
 PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE
 CONTRACTOR, ON LETTERHEAD, STATING THAT THE
 INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM
 COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH
 COUNTY WILL BE FOLLOWED, AND THAT NOTIFICATION WILL BE
 GIVEN TIMELY. ADDITIONAL INFORMATION REGARDING ASBESTOS
 REQUIREMENTS CAN BE FOUND ON THEIR WEBSITE:
  
 HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE
 S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION-
 RENOVATION.HTML
  
 THE CONTRACTOR ACKNOWLEDGEMENT CAN BE SENT VIA EMAIL TO
 [email protected]. THE INFORMATION SHOULD BE IN PDF
 FORMAT AS AN ATTACHMENT TO THE EMAIL. PLEASE INCLUDE
 THE PERMIT NUMBER AND "ASBESTOS" IN THE SUBJECT LINE.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2021-07-13 Cont ID  
Sent By jwitmer Date 2021-07-13 Time 18:44 Rev Time 0.00
Received By jwitmer Date 2021-07-13 Time 18:30 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2021-06-28 Cont ID  
Sent By jwitmer Date 2021-06-28 Time 09:44 Rev Time 0.00
Received By jwitmer Date 2021-06-28 Time 09:02 Sent To  
Notes
2021-06-28 09:41:39WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION
 SERVICES/ BUILDING DIVISION
 2020 FBC- BUILDING PLAN REVIEW
 W. P. B. PERMIT: 21020115
 ADD: 1316 ALAPHA STREET, UNIT # 1
 CONT: GEN-X CONSTRUCTION, INC.
 TEL: 561-963-4490
 E-MAIL: [email protected]
  
 2020 FLORIDA BUILDING CODE W 2020 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2020 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW
 CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES
 SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA
 BUILDING CODE, BUILDING.
  
 3RD REVIEW
 DATE: MON. JUNE 28TH/ 2021
 ACTION: DENIED
 1) 3RD REQUEST. SHEET 1ST FLOOR PLAN. SPOKE WITH THE
 DESIGNER OF RECORD THIS MORNING ABOUT COMMENT
 CORRECTIONS NEEDED.
  
 1A) 3RD REQUEST. THIS SUBMISSION THE PLANS NOW SHOW
 1-INCH THICK PAVERS TO MAKE A ELEVATED LANDING THE SAME
 HEIGHT AS THE INTERIOR FLOOR BUT DOES NOT SHOW THE 2
 REQUIRED RAMPS, ONE TO THE WALKWAY THE OTHER UNDER THE
 COVERED WALK WAY. WHEN VIEWING THE FRONT ENTRY TO UNIT
 # 3 THROUGH MY GEO NAV THE FRONT ENTRY DOORWAY APPEARS
 TO BE BETWEEN A 1 INCH TO 1-INCH 1/2 ABOVE THE
 SIDEWALK. FAIR HOUSING GUIDELINES SECTION 5 (1)(A)
 SEPARATE GROUND FLOOR ENTRANCES. WHEN A GROUND FLOOR
 UNIT OF A BUILDING HAS A SEPARATE ENTRANCE, EACH GROUND
 FLOOR UNIT SHALL BE SERVED BY AN ACCESSIBLE ROUTE. SEE
 SECTION (B) WHERE MULTIPLE DWELLING UNITS ARE ON THE
 1ST FLOOR MORE THAN ONE MANY MAYBE REQUIRED TO BE
 ACCESSIBLE.
 1ST ROUND OF COMMENTS. THE 1ST FLOOR PLAN INDICATES A
 NEW RAMP AT THE EXTERIOR SIDE OF THE FRONT DOOR. THE
 PLANS DO NOT CLEARLY SHOW THE TOP AND BOTTOM LANDINGS.
 PLEASE SHOW COMPLIANCE WITH THE 2020 FBC-BUILDING
 SECTION 1012.6 LANDINGS. RAMPS SHALL HAVE LANDINGS AT
 THE BOTTOM AND TOP OF EACH RAMP, POINTS OF TURNING
 ENTRANCE, EXITS AT DOORS AND IN ACCORDANCE WITH THE
 FLORIDA BUILDING CODE ACCESSIBILITY. LANDINGS SHALL
 COMPLY WITH SECTION 1012.6.1 THROUGH 1012.6.5.
  
 1B) 3RD REQUEST. DOORWAYS AT RAMPS (LANDINGS). 1012.6,5
 OF THE 2020 FBC-BUILDING. FAIR HOUSING ANSI A117.1
 SECTION 4.8. WHERE DOORWAYS ARE LOCATED ADJACENT TO A
 RAMP LANDING, MANEUVERING CLEARANCES REQUIRED BY ICC
 A117.1 ARE PERMITTED TO OVERLAP THE REQUIRED LANDING
 AREA.
  
 1C) 3RD REQUEST. FAIR HOUSING ANSI A117.1 SECTION 4.8.
 SHEET 1ST FLOOR PLAN AT FRONT ENTRY INDICATES THE
 BUILDING OF A NEW RAMP. THERE ARE SOME DIMENSIONS BUT
 THERE IS NO MENTION OR DETAILS FOR BUILDING THE LANDING
 NOR RAMP SECTION ITSELF. PLEASE SHOW COMPLIANCE WITH
 SECTION 1012.7 RAMP CONSTRUCTION. THE PLANS ARE SILENT
 AS TO THE LIVE LOAD DISTRIBUTIONS SEE FBC-B TABLE
 1607.1.
  
 1D) 3RD REQUEST. FAIR HOUSING ANSI A117.1 SECTION 4.8.
 PLEASE SHOW COMPLIANCE WITH THE 2020 FBC-B SECTION
 1012.7.1. RAMP SURFACE. THE SURFACE OF RAMPS SHALL BE
 OF A SLIP-RESISTANT MATERIALS THAT ARE SECURELY
 ATTACHED.
  
 1E) 3RD REQUEST. FAIR HOUSING ANSI A117.1 SECTION 4.8.
 PLEASE SHOW COMPLIANCE WITH THE 2020 FBC-B SECTION
 1012.7.2. OUTDOOR CONDITIONS. OUTDOOR RAMPS AND OUTDOOR
 APPROACHES TO RAMPS SHALL BE DESIGNED SO THAT WATER
 WILL NOT ACCUMULATE ON THE WALKING SURFACES.
  
  
 1F-1I) COMPLIED.
  
 2) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 PLEASE NOTE WITH THE LACK OF INFORMATION FOR THIS
 REVIEW, SUBSEQUENT REMARKS MAYBE MADE IN THE NEXT
 REVIEW CYCLE.
  
 PLEASE NOTE WE ARE WORKING FROM HOME BECAUSE OF COVID
 19
 IF YOU WOULD LIKE TO CONTACT ME, MY CELL NUMBER IS
 561-718-9724.
 WORKING HOURS ARE MON.- WED. 8:00 AM- NOON. PART-TIME/
 RETIRED.
  
 JAMES A. WITMER BN, PX, SFP, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2021-06-02 Cont ID  
Sent By jwitmer Date 2021-06-02 Time 08:59 Rev Time 0.00
Received By jwitmer Date 2021-06-02 Time 07:59 Sent To  
Notes
2021-06-02 08:59:21WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION
 SERVICES/ BUILDING DIVISION
 2020 FBC- BUILDING PLAN REVIEW
 W. P. B. PERMIT: 21020115
 ADD: 1316 ALAPHA STREET, UNIT # 1
 CONT: GEN-X CONSTRUCTION, INC.
 TEL: 561-963-4490
 E-MAIL: [email protected]
  
 2020 FLORIDA BUILDING CODE W 2020 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2020 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW
 CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES
 SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA
 BUILDING CODE, BUILDING.
  
 2ND REVIEW
 DATE: WED. JUNE 02ND / 2021
 ACTION: DENIED
 1) SHEET 1ST FLOOR PLAN.
 1A) WHEN VIEWING THE FRONT ENTRY TO UNIT # 3 THROUGH MY
 GEO NAV THE FRONT ENTRY DOORWAY APPEARS TO BE BETWEEN A
 1 ? INCHES TO 1 INCH ABOVE THE SIDEWALK. FAIR HOUSING
 GUIDELINES SECTION 5 (1)(A) SEPARATE GROUND FLOOR
 ENTRANCES. WHEN A GROUND FLOOR UNIT OF A BUILDING HAS A
 SEPARATE ENTRANCE, EACH GROUND FLOOR UNIT SHALL BE
 SERVED BY AN ACCESSIBLE ROUTE. SEE SECTION (B) WHERE
 MULTIPLE DWELLING UNITS ARE ON THE 1ST FLOOR MORE THAN
 ONE MANY MAYBE REQUIRED TO BE ACCESSIBLE.
 1ST ROUND OF COMMENTS. THE 1ST FLOOR PLAN INDICATES A
 NEW RAMP AT THE EXTERIOR SIDE OF THE FRONT DOOR. THE
 PLANS DO NOT CLEARLY SHOW THE TOP AND BOTTOM LANDINGS.
 PLEASE SHOW COMPLIANCE WITH THE 2020 FBC-BUILDING
 SECTION 1012.6 LANDINGS. RAMPS SHALL HAVE LANDINGS AT
 THE BOTTOM AND TOP OF EACH RAMP, POINTS OF TURNING
 ENTRANCE, EXITS AT DOORS AND IN ACCORDANCE WITH THE
 FLORIDA BUILDING CODE ACCESSIBILITY. LANDINGS SHALL
 COMPLY WITH SECTION 1012.6.1 THROUGH 1012.6.5.
  
 1B) 2ND REQUEST. DOORWAYS AT RAMPS (LANDINGS). 1012.6,5
 OF THE 2020 FBC-BUILDING. FAIR HOUSING ANSI A117.1
 SECTION 4.8. WHERE DOORWAYS ARE LOCATED ADJACENT TO A
 RAMP LANDING, MANEUVERING CLEARANCES REQUIRED BY ICC
 A117.1 ARE PERMITTED TO OVERLAP THE REQUIRED LANDING
 AREA.
  
 1C) 2ND REQUEST. FAIR HOUSING ANSI A117.1 SECTION 4.8.
 SHEET 1ST FLOOR PLAN AT FRONT ENTRY INDICATES THE
 BUILDING OF A NEW RAMP. THERE ARE SOME DIMENSIONS BUT
 THERE IS NO MENTION OR DETAILS FOR BUILDING THE LANDING
 NOR RAMP SECTION ITSELF. PLEASE SHOW COMPLIANCE WITH
 SECTION 1012.7 RAMP CONSTRUCTION. THE PLANS ARE SILENT
 AS TO THE LIVE LOAD DISTRIBUTIONS SEE FBC-B TABLE
 1607.1.
  
 1D) 2ND REQUEST. FAIR HOUSING ANSI A117.1 SECTION 4.8.
 PLEASE SHOW COMPLIANCE WITH THE 2020 FBC-B SECTION
 1012.7.1. RAMP SURFACE. THE SURFACE OF RAMPS SHALL BE
 OF A SLIP-RESISTANT MATERIALS THAT ARE SECURELY
 ATTACHED.
  
 1E) 2ND REQUEST. FAIR HOUSING ANSI A117.1 SECTION 4.8.
 PLEASE SHOW COMPLIANCE WITH THE 2020 FBC-B SECTION
 1012.7.2. OUTDOOR CONDITIONS. OUTDOOR RAMPS AND OUTDOOR
 APPROACHES TO RAMPS SHALL BE DESIGNED SO THAT WATER
 WILL NOT ACCUMULATE ON THE WALKING SURFACES.
  
 1G) 2ND REQUEST. FAIR HOUSING ANSI A117.1 SECTION 4.8.
 THIS PROPOSED RAMP IS INDICATED TO BE 1 ? INCHES IN
 HEIGHT. HANDRAILS REQUIRED BY 1012.8 ARE NOT REQUIRED
 FOR RAMPS LESS THAN 6 INCHES. GUARDS REQUIRED BY 1012.9
 WHERE REQUIRED BY 1015.2 RAMPS AND LANDINGS LOCATED 30
 INCHES ABOVE GRADE, ALSO NOT REQUIRED. EDGE PROTECTION
 REQUIRED BY SECTION 1012.10 IS NOT INDICATED ON THE
 PLANS.
  
 1H-K) N/A, NOT APPLICABLE.
  
 1L) BATHROOM GRAB BARS FOR THE WATER CLOSET. 2021
 FBC-ACCESSIBILITY CODE SECTION 609.4 POSITION OF GRAB
 BARS. GRAB BARS SHALL BE INSTALLED IN A HORIZONTAL
 POSITION, 33 INCHES MINIMUM AND 36 INCHES MAXIMUM ABOVE
 THE FINISH FLOOR MEASURED TO THE TOP OF THE GRIPPING
 SURFACE, NOT CENTERLINE.
  
 2) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 PLEASE NOTE WITH THE LACK OF INFORMATION FOR THIS
 REVIEW, SUBSEQUENT REMARKS MAYBE MADE IN THE NEXT
 REVIEW CYCLE.
  
 PLEASE NOTE WE ARE WORKING FROM HOME BECAUSE OF COVID
 19
 IF YOU WOULD LIKE TO CONTACT ME, MY CELL NUMBER IS
 561-718-9724.
 WORKING HOURS ARE MON.- WED. 8:00 AM- NOON. PART-TIME/
 RETIRED.
  
 JAMES A. WITMER BN, PX, SFP, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 DEVELOPMENT SERVICES HOME PAGE
 HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP
  
 PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS
 LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS
 REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO
 THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE
 THEREFORE SUBJECT TO PUBLIC DISCLOSURE.
  
 MEMBER OF BOAF: BUILDING OFFICIALS ASSOCIATION OF
 FLORIDA SAVING LIVES AND PROPERTY SINCE 1953
  
  
  
  
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2021-02-09 Cont ID  
Sent By jwitmer Date 2021-02-09 Time 15:45 Rev Time 0.00
Received By jwitmer Date 2021-02-09 Time 14:17 Sent To  
Notes
2021-02-09 15:43:06WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION
 SERVICES/ BUILDING DIVISION
 2020 FBC- BUILDING PLAN REVIEW
 W. P. B. PERMIT: 21020115
 ADD: 1316 ALAPHA STREET, UNIT # 1
 CONT: GEN-X CONSTRUCTION, INC.
 TEL: 561-963-4490
 E-MAIL: [email protected]
  
 2020 FLORIDA BUILDING CODE W 2020 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2020 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW
 CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES
 SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA
 BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: TUES. FEB. 09TH/ 2021
 ACTION: DENIED
  
 1) SHEET 1ST FLOOR PLAN.
 1A) THE 1ST FLOOR PLAN INDICATES A NEW RAMP AT THE
 EXTERIOR SIDE OF THE FRONT DOOR. THE PLANS DO NOT
 CLEARLY SHOW THE TOP AND BOTTOM LANDINGS. PLEASE SHOW
 COMPLIANCE WITH THE 2020 FBC-BUILDING SECTION 1012.6
 LANDINGS. RAMPS SHALL HAVE LANDINGS AT THE BOTTOM AND
 TOP OF EACH RAMP, POINTS OF TURNING ENTRANCE, EXITS AT
 DOORS AND IN ACCORDANCE WITH THE FLORIDA BUILDING CODE
 ACCESSIBILITY. LANDINGS SHALL COMPLY WITH SECTION
 1012.6.1 THROUGH 1012.6.5.
  
 1B) DOORWAYS AT RAMPS (LANDINGS). 1012.6,5 OF THE 2020
 FBC-BUILDING. WHERE DOORWAYS ARE LOCATED ADJACENT TO A
 RAMP LANDING, MANEUVERING CLEARANCES REQUIRED BY ICC
 A117.1 ARE PERMITTED TO OVERLAP THE REQUIRED LANDING
 AREA.
  
 1C) SHEET 1ST FLOOR PLAN AT FRONT ENTRY INDICATES THE
 BUILDING OF A NEW RAMP. THERE ARE SOME DIMENSIONS BUT
 THERE IS NO MENTION OR DETAILS FOR BUILDING THE LANDING
 NOR RAMP SECTION ITSELF. PLEASE SHOW COMPLIANCE WITH
 SECTION 1012.7 RAMP CONSTRUCTION. THE PLANS ARE SILENT
 AS TO THE LIVE LOAD DISTRIBUTIONS SEE FBC-B TABLE
 1607.1.
  
 1D) PLEASE SHOW COMPLIANCE WITH THE 2020 FBC-B SECTION
 1012.7.1. RAMP SURFACE. THE SURFACE OF RAMPS SHALL BE
 OF A SLIP-RESISTANT MATERIALS THAT ARE SECURELY
 ATTACHED.
  
 1E) PLEASE SHOW COMPLIANCE WITH THE 2020 FBC-B SECTION
 1012.7.2. OUTDOOR CONDITIONS. OUTDOOR RAMPS AND OUTDOOR
 APPROACHES TO RAMPS SHALL BE DESIGNED SO THAT WATER
 WILL NOT ACCUMULATE ON THE WALKING SURFACES.
  
 1G) THIS PROPOSED RAMP IS INDICATED TO BE 5 INCHES IN
 HEIGHT. HANDRAILS REQUIRED BY 1012.8 ARE NOT REQUIRED
 FOR RAMPS LESS THAN 6 INCHES. GUARDS REQUIRED BY 1012.9
 WHERE REQUIRED BY 1015.2 RAMPS AND LANDINGS LOCATED 30
 INCHES ABOVE GRADE, ALSO NOT REQUIRED. EDGE PROTECTION
 REQUIRED BY SECTION 1012.10 IS NOT INDICATED ON THE
 PLANS.
  
 1H) SHEET 1ST DEMOLITION FLOOR PLAN SHOWS THE REMOVAL
 OF THE FRONT DOOR ASSEMBLY. THE PROPOSED FLOOR PLAN
 INDICATES THE INSTALLATION OF AN EXTERIOR OUTSWING DOOR
 W/ MAXIMUM ? INCH THRESHOLD. THE FLOOR PLAN IS SILENT
 AS TO THE WIND DESIGN CRITERIA AND COMPONENTS AND
 CLADDING PRESSURES.
 2020 FBC-B 1603.1.4 WIND DESIGN DATA.
 THE FOLLOWING INFORMATION RELATED TO WIND LOADS SHALL
 BE SHOWN, REGARDLESS OF WHETHER WIND LOADS GOVERN THE
 DESIGN OF THE LATERAL FORCE-RESISTING SYSTEM OF THE
 STRUCTURE:
  
 1H)(1). ULTIMATE DESIGN WIND SPEED, VULT, (3-SECOND
 GUST), MILES PER HOUR AND NOMINAL DESIGN WIND SPEED,
 VASD, AS DETERMINED IN ACCORDANCE WITH SECTION
 1609.3.1.
  
 1H)(2.) RISK CATEGORY.
  
 1H)(3.) WIND EXPOSURE. APPLICABLE WIND DIRECTION IF
 MORE THAN ONE WIND EXPOSURE IS UTILIZED. TABLE
 1609.7.2. HEIGHT AND EXPOSURE. ASCE 7-10 TABLE 30.3.1.
  
 1H)(4.) APPLICABLE INTERNAL PRESSURE COEFFICIENT.
  
 1H)(5.) DESIGN WIND PRESSURES TO BE USED FOR EXTERIOR
 COMPONENTS AND CLADDING MATERIALS SPECIFICALLY DESIGNED
 BY THE REGISTERED DESIGN PROFESSIONAL RESPONSIBLE FOR
 THE DESIGN OF THE STRUCTURE, PSF.
  
 1H)(6.) TABLE 1609.7(2) ADJUSTMENT FACTORS FOR HEIGHT &
 EXPOSURE. PROVIDE THE MEAN ROOF HEIGHT FOR THE
 BUILDING.. ASCE 7-10 TABLE 30.3.1. 1609.3.1 WIND SPEED
 CONVERSION VULT TO VASD.
  
  
 1I) 2020 FBC-B 1609.1.2 PROTECTION OF OPENINGS,
 1609.6.4.4.1 COMPONENTS & CLADDING. FLORIDA DEPARTMENT
 OF COMMUNITY AFFAIRS, ADMINISTRATIVE CODE 61G20-3.005,
 RULE 9N-3 NOV. 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS
 OR CONSTRUCTION SYSTEMS THAT WILL REQUIRE PRODUCT
 APPROVALS: (31)(A) EXTERIOR DOORS.
  
 1J) W. P. B. 107.3.4. PRODUCT APPROVALS. THOSE PRODUCTS
 WHICH ARE REGULATED BY FLORIDA ADMINISTRATIVE CODE RULE
 61G20 SHALL BE REVIEWED AND APPROVED IN WRITING (SHOP
 DRAWING STAMP OF APPROVAL) BY THE DESIGNER OF RECORD
 PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL.
 FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR
 SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS,
 SHOP DRAWINGS ETC.
  
 1K) 2020 FBC-B HABITAL SPACES/ 1709.5.1.1FBC-B EXTERIOR
 WINDOWS AND DOORS. (EXCEPTION) 2. DOOR ASSEMBLIES
 INSTALLED WHERE THE OVERHANG (OH) RATIO IS EQUAL TO OR
 MORE THAN 1 NEED NOT BE TESTED FOR WATER INFILTRATION.
  
 1L) BATHROOM GRAB BARS FOR THE WATER CLOSET. 2021
 FBC-ACCESSIBILITY CODE SECTION 609.4 POSITION OF GRAB
 BARS. GRAB BARS SHALL BE INSTALLED IN A HORIZONTAL
 POSITION, 33 INCHES MINIMUM AND 36 INCHES MAXIMUM ABOVE
 THE FINISH FLOOR MEASURED TO THE TOP OF THE GRIPPING
 SURFACE, NOT CENTERLINE.
  
 2) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 PLEASE NOTE WITH THE LACK OF INFORMATION FOR THIS
 REVIEW, SUBSEQUENT REMARKS MAYBE MADE IN THE NEXT
 REVIEW CYCLE.
  
 PLEASE NOTE WE ARE WORKING FROM HOME BECAUSE OF COVID
 19
 IF YOU WOULD LIKE TO CONTACT ME, MY CELL NUMBER IS
 561-718-9724.
 WORKING HOURS ARE MON.- WED. 8:00 AM- NOON. PART-TIME/
 RETIRED.
  
 JAMES A. WITMER BN, PX, SFP, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 DEVELOPMENT SERVICES HOME PAGE
 HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP
  
 PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS
 LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS
 REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO
 THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE
 THEREFORE SUBJECT TO PUBLIC DISCLOSURE.
  
 MEMBER OF BOAF: BUILDING OFFICIALS ASSOCIATION OF
 FLORIDA SAVING LIVES AND PROPERTY SINCE 1953
  
  
  
  
  
  
  

Review Stop E ELECTRICAL
Rev No 4 Status P Date 2021-06-29 Cont ID  
Sent By jleahy Date 2021-06-29 Time 12:54 Rev Time 0.00
Received By jleahy Date 2021-06-29 Time 12:51 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2021-06-04 Cont ID  
Sent By jleahy Date 2021-06-04 Time 08:43 Rev Time 0.00
Received By jleahy Date 2021-06-04 Time 08:38 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2021-03-25 Cont ID  
Sent By jleahy Date 2021-03-25 Time 08:32 Rev Time 0.00
Received By jleahy Date 2021-03-25 Time 08:32 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2021-02-16 Cont ID  
Sent By jleahy Date 2021-02-16 Time 16:00 Rev Time 0.00
Received By jleahy Date 2021-02-16 Time 15:39 Sent To  
Notes
2021-02-16 16:02:20ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 FLORIDA BUILDING CODE 2017 6TH EDITION
 FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 6TH ED
 NFPA 70 2014 EDITION
  
 JAKE LEAHY BN, BU, PX
 ELECTRICAL PLANS EXAMINER II
 561-805-6713
 [email protected]
  
 PROVIDE ELECTRICAL PLAN FOR REVIEW, SIGNED AND SEALED
 BY A LICENSED DESIGN PROFESSIONAL OR THE ELECTRICAL
 CONTRACTOR QUALIFIER. IF THERE IS NOT ANY ELECTRICAL
 WORK INCLUDED WITH THIS PERMIT, STATE THAT ON PLAN. FS
 471.003(2)(H); 471.025; FBC 107.2.1, 107.3.5

Review Stop FIRE FIRE DEPARTMENT
Rev No 4 Status P Date 2021-07-13 Cont ID  
Sent By pleduc Date 2021-07-13 Time   Rev Time 0.00
Received By pleduc Date 2021-07-13 Time 09:55 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2021-06-24 Cont ID  
Sent By pleduc Date 2021-06-24 Time   Rev Time 0.00
Received By pleduc Date 2021-06-24 Time 13:25 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2021-06-03 Cont ID  
Sent By pleduc Date 2021-06-03 Time   Rev Time 0.00
Received By pleduc Date 2021-06-03 Time 10:22 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2021-02-12 Cont ID  
Sent By pleduc Date 2021-02-12 Time   Rev Time 0.00
Received By pleduc Date 2021-02-09 Time 16:19 Sent To  
Notes
2021-02-12 12:15:23THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE
 MARSHAL, WITH THE FOLLOWING COMMENTS:
  
 1) THERE IS NO SLOPE INDICATED FOR THE DORRWAY RAMP.
  
 PER NFPA 101, CH 7 MEANS OF EGRESS
  
 7.2.5.3 DIMENSIONAL CRITERIA. THE FOLLOWING DIMENSIONAL
 CRITERIA SHALL
 APPLY TO RAMPS:
 (1) NEW RAMPS SHALL BE IN ACCORDANCE WITH TABLE
 7.2.5.3(A), UNLESS
 OTHERWISE PERMITTED BY THE FOLLOWING:
 (A) TABLE 7.2.5.3(A) SHALL NOT APPLY TO INDUSTRIAL
 EQUIPMENT ACCESS
 AREAS AS PROVIDED IN 40.2.5.3.
  
 1 IN 12
  
 PLEASE REVIEW AND CORRECT.
  
  
 2) THERE IS NO RAMP MATERIAL TYPE INDICATED.
  
 PER NFPA 101, CH 7 MEANS OF EGRESS
  
 7.2.5.4.1 CONSTRUCTION. RAMP CONSTRUCTION SHALL BE AS
 FOLLOWS:
 (1) ALL RAMPS SERVING AS REQUIRED MEANS OF EGRESS SHALL
 BE OF PERMANENT
 FIXED CONSTRUCTION.
 (2) EACH RAMP IN BUILDINGS REQUIRED BY THIS CODE TO BE
 OF TYPE I OR
 TYPE II CONSTRUCTION SHALL BE ANY COMBINATION OF
 NONCOMBUSTIBLE
 OR LIMITED-COMBUSTIBLE MATERIAL OR
 FIRE-RETARDANT?TREATED WOOD.
 (3) RAMPS CONSTRUCTED WITH FIRE-RETARDANT?TREATED WOOD
 SHALL BE NOT
 MORE THA
  
 N 30 IN. (760 MM) HIGH, SHALL HAVE AN AREA OF NOT MORE
 THAN 3000 FT2 (277 M2), AND SHALL NOT OCCUPY MORE THAN
 50 PERCENT
 OF THE ROOM AREA.
 (4) THE RAMP FLOOR AND LANDINGS SHALL BE SOLID AND
 WITHOUT
 PERFORATIONS.
  
 PLEASE REVIEW AND PROVIDE DETAILS IN COMPLIANCE.
  
  
 3) THERE IS AN INDICATION OF THE NEW BATHROOM DOOR
 OPENING INTO THE CORRIDOR RESTRICTING THE MEANS OF
 EGRESS FROM THE TWO BEDROOMS.
  
 PER NFPA 101, CH 7 MEANS OF EGRESS
  
 7.2.1.4.3 DOOR LEAF ENCROACHMENT
  
 7.2.1.4.3.1 DURING ITS SWING, ANY DOOR LEAF IN A MEANS
 OF EGRESS SHALL
 LEAVE NOT LESS THAN ONE-HALF OF THE REQUIRED WIDTH OF
 AN AISLE, A CORRIDOR,
 A PASSAGEWAY, OR A LANDING UNOBSTRUCTED, UNLESS BOTH OF
 THE FOLLOWING
 CONDITIONS ARE MET:
 (1) THE DOOR OPENING PROVIDES ACCESS TO A STAIR IN AN
 EXISTING
 BUILDING.
 (2) THE DOOR OPENING MEETS THE REQUIREMENT OF
 7.2.1.4.3.2.
  
 7.2.1.4.3.2 WHEN FULLY OPEN, ANY DOOR LEAF IN A MEANS
 OF EGRESS SHALL
 NOT PROJECT MORE THAN 7 IN. (180 MM) INTO THE REQUIRED
 WIDTH OF AN AISLE,
 A CORRIDOR, A PASSAGEWAY, OR A LANDING, UNLESS THE DOOR
 LEAF IS EQUIPPED
 WITH AN APPROVED SELF-CLOSING DEVICE AND IS NOT
 REQUIRED BY THE PROVISIONS
 OF 7.2.1.4.2 TO SWING IN THE DIRECTION OF EGRESS
 TRAVEL.
  
 PLEASE REVIEW AND CORRECT OR PROVIDE DIMENSIONS IN
 COMPLIANCE
  
  
  
 4) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET
 REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE
 ABOVE.
  
  
 5) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE
 RE-SUBMITTAL OF THE ABOVE.
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date   Cont ID  
Sent By   Date 2021-07-23 Time   Rev Time 0.00
Received By aoliver Date 2021-07-12 Time 10:29 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date   Cont ID  
Sent By   Date 2021-07-02 Time   Rev Time 0.00
Received By aoliver Date 2021-06-23 Time 16:09 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date   Cont ID  
Sent By   Date 2021-06-11 Time   Rev Time 0.00
Received By aoliver Date 2021-05-27 Time 13:37 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date   Cont ID  
Sent By   Date 2021-02-22 Time   Rev Time 0.00
Received By ccarvaja Date 2021-02-04 Time 12:41 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status N Date 2021-02-09 Cont ID  
Sent By jwitmer Date 2021-02-09 Time 15:46 Rev Time 0.00
Received By jwitmer Date 2021-02-09 Time 14:17 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 4 Status P Date 2021-07-23 Cont ID  
Sent By ccole Date 2021-07-23 Time 11:00 Rev Time 0.00
Received By ccole Date 2021-07-23 Time 08:11 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status F Date 2021-07-02 Cont ID  
Sent By ccole Date 2021-07-02 Time 16:44 Rev Time 0.00
Received By ccole Date 2021-07-02 Time 15:28 Sent To  
Notes
2021-07-02 16:44:563RD REVIEW FBC-2020 PLUMBING
 PERMIT-21020115
 7/2/2021
  
 CODES IN EFFECT:
 FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020
 FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020
 FBC B- FLORIDA BUILDING CODE 7TH EDITION 2020
 FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION
 2020
 FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SHEETS F1 & F2: BASED ON TELEPHONE CALL WITH THE
 ENGINEER OF RECORD, THE BATHROOM IS BEING DESIGNED TO
 MEET FULL COMPLIANCE WITH THE FBC ACC AND NOT THE FAIR
 HOUSING ACT DESIGN MANUAL. IF DESIGNED A AS A
 TRANSFER-TYPE SHOWER UNDER SECTIONS 608.2 & 608.2.1 FBC
 ACC THE SHOWER SHALL BE 36 INCHES BY 36 INCHES CLEAR
 INSIDE DIMENSIONS MEASURED AT THE CENTER POINTS OF
 OPPOSING SIDES AND SHALL HAVE A 36 INCH-WIDE MINIMUM
 ENTRY ON THE FACE OF THE SHOWER COMPARTMENT. CLEARANCE
 MEANING A CLEAR FLOOR SPACE OF 36 INCHES WIDE MINIMUM
 BY 48 INCHES LONG MINIMUM MEASURED FROM THE CONTROL
 WALL SHALL BE PROVIDED. IF DESIGNED AS A STANDARD
 ROLL-IN TYPE SHOWER COMPARTMENT UNDER SECTION 608.2.2,
 IT SHALL BE 30 INCHES WIDE MINIMUM BY 60 INCHES DEEP
 MINIMUM CLEAR INSIDE DIMENSIONS MEASURED AT CENTER
 POINTS OF OPPOSING SIDES AND SHALL HAVE A 60 INCHES
 (1525 MM) WIDE MINIMUM ENTRY ON THE FACE OF THE SHOWER
 COMPARTMENT.
  
 THE CURRENT PLAN SHOWS A 36 IN. X 48 IN. SHOWER WHICH
 DOES NOT MEET FBC ACC COMPLIANCE, BUT DOES MEET
 COMPLIANCE WITH THE FAIR HOUSING DESIGN MANUAL
 SPECIFICATIONS AS INDICATED ON PAGES 7.56 AND 7.58 OF
 THE MANUAL.
  
 2) F2, DETAILS B & F: PLEASE INDICATE THE CONTROL SHALL
 BE LOCATED ON THE CONTROL WALL 15 INCHES MAXIMUM FROM
 THE CENTERLINE OF THE SEAT TOWARD THE SHOWER OPENING.
 PLEASE MATCH THE LOCATION OF THE FAUCET AS SHOWN IN THE
 NORTH WALL DETAIL WITH DETAILS B & F, OR REMOVE THE 18"
 MEASUREMENT- SECTION 608.5.1 FBC ACC.
  
 3) F2: PLEASE PROVIDE THE TOE CLEARANCES FOR THE
 ACCESSIBLE LAVATORY AND SINK AS SHOWN IN FIGURE 306.2
 FBC ACC.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop P PLUMBING
Rev No 2 Status F Date 2021-06-08 Cont ID  
Sent By ccole Date 2021-06-08 Time 18:08 Rev Time 0.00
Received By ccole Date 2021-06-08 Time 07:50 Sent To  
Notes
2021-06-08 18:08:552ND REVIEW FBC-2020 PLUMBING
 PERMIT-21020115
 6/8/2021
  
 CODES IN EFFECT:
 FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020
 FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020
 FBC B- FLORIDA BUILDING CODE 7TH EDITION 2020
 FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION
 2020
 FBC FG- FLORIDA FUEL GAS CODE 7TH EDITION 2020
 FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
 FAILED COMMENTS FROM THE 1ST REVIEW ARE LISTED BELOW
 WITH ADDITIONAL NOTES.
  
 1) SHEET F1, BATHROOM DETAILS- FBC ACC COMPLIANCES:
  
 A) FAILED- F2: PROVIDE THE CLEAR FLOOR SPACE DIAGRAMS
 AND DIMENSIONS FOR THE WATER CLOSET, LAVATORY SINK, AND
 THE SHOWER- SECTIONS 604.3, 606.2, AND 608.2.2. THE 30
 X 48 INCH CLEAR FLOOR SPACE FOR THE SHOWER NOT
 PROVIDED. THE DOOR SHALL NOT SWING INTO THE CLEAR FLOOR
 SPACE FOR THE LAVATORY UNLESS A 30X48 INCH CLEAR FLOOR
 SPACE IS PROVIDED BEYOND THE ARC OF THE DOOR- SECTION
 603.2.3 (2) FBC ACC.
 D) FAILED- F2: LOCATIONS, LENGTHS, AND MOUNTING HEIGHTS
 OF GRAB BARS FOR THE WATER CLOSET- 604.5 & 609.4,
 FIGURES 604.5.1 & 604.5.2. IT IS ACKNOWLEDGED THAT ONLY
 THE REINFORCEMENT IS REQUIRED HOWEVER THE GRAB BARS
 SHALL BE POSITIONED 33 INCHES MINIMUM AND 36 INCHES
 MAXIMUM ABOVE THE FINISH FLOOR MEASURED TO THE TOP OF
 THE GRIPPING SURFACES- NOT TO THE CENTERS OF THE BARS.
 G) FAILED- F2: COMPLETE KNEE AND TOE CLEARANCES FOR THE
 LAVATORY- 606.2. PLEASE SEE FIGURE 306.3 AND CORRECT
 THE KNEE AND TOE CLEARANCE DRAWINGS FOR THE LAV AND
 KITCHEN SINK.THE KNEE CLEARANCE SHALL EXTEND A MINIMUM
 OF 8 INCHES BELOW THE SINK MEASURED FROM THE FRONT
 EDGE.
 H) FAILED- F2: LOCATIONS, LENGTHS, AND MOUNTING HEIGHTS
 OF GRAB BARS FOR THE ACCESSIBLE SHOWER- SECTION 608.3
 AND 608.3.1. IT IS ACKNOWLEDGED THAT ONLY THE
 REINFORCEMENT IS REQUIRED HOWEVER THE GRAB BARS SHALL
 BE POSITIONED 33 INCHES MINIMUM AND 36 INCHES MAXIMUM
 ABOVE THE FINISH FLOOR MEASURED TO THE TOP OF THE
 GRIPPING SURFACES- NOT TO THE CENTERS OF THE BARS.
 I) FAILED- F2: LOCATION OF CONTROL, FAUCET, AND SHOWER
 SPRAY IN THE SHOWER- SECTION 608.5.1. THE CONTROL,
 FAUCET, AND SHOWER SPRAY SHALL BE LOCATED ON THE
 CONTROL WALL 15 INCHES MAXIMUM FROM THE CENTERLINE OF
 THE SEAT TOWARD THE SHOWER OPENING.
 K) FAILED- F2: LOCATION OF ACCESSIBLE SHOWER SEAT-
 SECTIONS 610.3 & 610.3.2. THE LOCATION OF THE SEAT IS
 CORRECT HOWEVER THE ACTUAL SEAT DIMENSIONS ARE NOT
 SHOWN IN ACCORDANCE WITH FIGURE 610.3.2.
 L) FAILED- F2: SHOW THE CLEAR FLOOR SPACE DIAGRAM AND
 DIMENSIONS FOR THE KITCHEN SINK- SECTION 606.2. THE
 CLEAR FLOOR SPACE DIAGRAM DOES NOT APPEAR TO EXTEND
 INTO THE KNEE AND TOE SPACE- FIGURE 306.2.
  
 5) FAILED- F1: SHOW THE SOURCE OF HOT WATER AND
 INDICATE IF COLD OR TEMPERED WATER WILL BE PROVIDED TO
 THE LAVATORY SINK- SECTIONS 419.5 AND 607.1 FBC P.
 BECAUSE HOT WATER IS BEING PROVIDED IT SHALL BE
 TEMPERED.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2021-02-22 Cont ID  
Sent By ccole Date 2021-02-22 Time 09:41 Rev Time 0.00
Received By ccole Date 2021-02-18 Time 17:03 Sent To  
Notes
2021-02-22 09:41:541ST REVIEW FBC-2020 PLUMBING
 PERMIT-21020115
 2/22/2021
  
 CODES IN EFFECT:
 FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020
 FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020
 FBC B- FLORIDA BUILDING CODE 7TH EDITION 2020
 FBC M- FLORIDA MECHANICAL CODE 7TH EDITION 2020
 FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION
 2020
 FBC FG- FLORIDA FUEL GAS CODE 7TH EDITION 2020
 FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) COVER SHEET: PLEASE UPDATE THE CODE REFERENCES- THE
 FBC- 2020 7TH EDITION CODES WENT INTO EFFECT ON
 12/31/20.
  
 2) COVER SHEET: PROVIDE THE OCCUPANCY CLASSIFICATION OF
 THE SPACE AND PLUMBING FIXTURE CALCULATIONS IN
 ACCORDANCE WITH TABLE 403.1 FBC P. PROVIDE A SCHEDULE
 THAT INDICATES THE REQUIRED AND PROVIDED NUMBER OF
 PLUMBING FIXTURES.
  
 3) COVER SHEET: PLEASE CLARIFY THE SCOPE OF WORK. THE
 FBC ACC IS THE GOVERNING ACCESSIBILITY CODE. REFER TO
 SECTION 101.1.2- ALL NEW OR ALTERED PUBLIC BUILDINGS
 AND FACILITIES, PRIVATE BUILDINGS AND FACILITIES,
 PLACES OF PUBLIC ACCOMMODATION, AND COMMERCIAL
 FACILITIES SUBJECT TO THIS CODE SHALL COMPLY WITH THIS
 CODE. PLEASE MAKE CORRECTIONS TO THE DRAWINGS PER THE
 FBC ACC SECTIONS LISTED BELOW.
  
 SHEET F1, BATHROOM DETAILS- FBC ACC COMPLIANCES:
 A) PROVIDE THE CLEAR FLOOR SPACE DIAGRAMS AND
 DIMENSIONS FOR THE WATER CLOSET, LAVATORY SINK, AND THE
 SHOWER- SECTIONS 604.3, 606.2, AND 608.2.2.
 B) PROVIDE THE HEIGHT OF THE TOILET SEAT MEASURED FROM
 THE FINISHED FLOOR- 604.4.
 C) HEIGHT OF THE MIRROR FROM THE FINISHED FLOOR TO THE
 REFLECTIVE SURFACE- 603.3
 D) LOCATIONS, LENGTHS, AND MOUNTING HEIGHTS OF GRAB
 BARS FOR THE WATER CLOSET- 604.5 & 609.4, FIGURES
 604.5.1 & 604.5.2.
 E) LOCATION OF THE WATER CLOSET FLUSH CONTROL- 604.6.
 F) CENTERLINE OF THE TOILET PAPER DISPENSER MEASURED
 FROM THE FRONT OF THE WATER CLOSET- 604.7.
 G) COMPLETE KNEE AND TOE CLEARANCES FOR THE LAVATORY-
 606.2.
 H) LOCATIONS, LENGTHS, AND MOUNTING HEIGHTS OF GRAB
 BARS FOR THE ACCESSIBLE SHOWER- SECTION 608.3 AND
 608.3.1
 I) LOCATION OF CONTROL, FAUCET, AND SHOWER SPRAY IN THE
 SHOWER- SECTION 608.5.1.
 J) SHOWER SPRAY UNIT SPECIFICATIONS PER SECTION 608.6.
 K) LOCATION OF ACCESSIBLE SHOWER SEAT- SECTIONS 610.3 &
 610.3.2.
 L) SHOW THE CLEAR FLOOR SPACE DIAGRAM AND DIMENSIONS
 FOR THE KITCHEN SINK- SECTION 606.2.
  
 4) F1: PROVIDE A WATER RISER DRAWING- SECTION
 107.3.5.1.3 WPB.
  
 5) F1: SHOW THE SOURCE OF HOT WATER AND INDICATE IF
 COLD OR TEMPERED WATER WILL BE PROVIDED TO THE LAVATORY
 SINK- SECTIONS 419.5 AND 607.1 FBC P.
  
 6) F1: PROVIDE A SHOWER PAN DETAIL- SECTIONS 421.4.1-
 421.5.2 FBC P.
  
 7) PROVIDE A PLUMBING FIXTURE SCHEDULE- SECTIONS 404,
 405, 409, 412, 419, 420, & 422- FBC P.
  
 8) F1: PROVIDE A SLAB REPAIR DETAIL- SECTION 107.2.1
 WPB.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 4 Status P Date 2021-07-13 Cont ID  
Sent By jwitmer Date 2021-07-13 Time 18:44 Rev Time 0.00
Received By jwitmer Date 2021-07-13 Time 18:30 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status P Date 2021-07-02 Cont ID  
Sent By ccole Date 2021-07-02 Time 15:52 Rev Time 0.00
Received By ccole Date 2021-07-02 Time 15:28 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2021-06-08 Cont ID  
Sent By ccole Date 2021-06-08 Time 18:12 Rev Time 0.00
Received By ccole Date 2021-06-08 Time 18:12 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2021-02-22 Cont ID  
Sent By ccole Date 2021-02-22 Time 09:51 Rev Time 0.00
Received By ccole Date 2021-02-22 Time 09:51 Sent To  
Notes
2021-02-22 09:51:33SIGNATURE REVIEW
 PERMIT-21020115
 2/22/2021
  
 1) THE PLANS ARE NOT DIGITALLY SIGNED AND SEALED BY THE
 ENGINEER OF RECORD- FL. STATUTE 471.025 AND SECTION
 61G15-23.005 FAC.
  
 FLORIDA BOARD OF PROFESSIONAL ENGINEERS GUIDELINES FOR
 ELECTRONIC OR DIGITALLY SIGNED AND SEALED PLANS AND
 DOCUMENTS.
 A DIGITAL SIGNATURE MUST BE UNIQUE TO THE PROFESSIONAL
 ENGINEER USING IT, OBTAINED FROM A THIRD-PARTY
 CERTIFICATION AUTHORITY, AND CAPABLE OF VERIFICATION.
 THE CERTIFICATION AUTHORITY WILL VET THE PE AND PROVIDE
 A PASSWORD-PROTECTED DIGITAL SIGNATURE FILE. (FBPE DOES
 NOT APPROVE OR PROVIDE A LIST OF AUTHORITIES.)
 YOU MAY NOT USE THE DIGITAL OPTION PROVIDED IN ADOBE
 ACROBAT, SINCE IT IS SELF-AUTHENTICATED AND DOES NOT
 USE A THIRD PARTY.
 YOUR DIGITAL SIGNATURE MUST BE LINKED TO THE DOCUMENT
 IN SUCH A WAY THAT ANY CHANGE INVALIDATES THE SIGNATURE
 AND DOCUMENT.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  
  

Review Stop Z ZONING
Rev No 2 Status P Date 2021-06-09 Cont ID  
Sent By rthermid Date 2021-06-09 Time   Rev Time 0.00
Received By rthermid Date 2021-06-09 Time   Sent To I
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2021-02-17 Cont ID  
Sent By rthermid Date 2021-02-17 Time   Rev Time  
Received By rthermid Date 2021-02-17 Time   Sent To I
Notes
***NONE***