Plan Review Details - Permit 21011138
Plan Review Stops For Permit 21011138
Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2021-02-03 Cont ID  
Sent By lcrespo Date 2021-02-03 Time 10:29 Rev Time 0.00
Received By lcrespo Date 2021-02-02 Time 11:37 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2021-02-04 Cont ID  
Sent By lcrespo Date 2021-02-04 Time 13:32 Rev Time 0.00
Received By lcrespo Date 2021-02-04 Time 13:32 Sent To  
Notes
2021-02-04 13:33:1902/04/21 REVIEWED FOR CODE COMPLIANCE (PLUMBING)
  
 BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE
 COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN
 PROFESSIONAL, CONTRACTORS, OR THEIR REPRESENTATIVES
 FROM THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL,
 STATE, AND NATIONAL CODES AND STANDARDS IN EFFECT AT
 THE TIME OF PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK
 OF EVERY ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM
 REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES
 / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO
 AVOID VOIDING OF THE PERMIT.
  
 LUIS A. CRESPO
 PLUMBING PLAN EXAMINER / INSPECTOR
 EMAIL: [email protected] OFFICE: 561 805-6720
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2021-02-03 Cont ID  
Sent By lcrespo Date 2021-02-03 Time 10:16 Rev Time 0.00
Received By lcrespo Date 2021-02-03 Time 10:16 Sent To  
Notes
2021-02-03 10:37:5802/03/21 1ST PLUMBING REVIEW**DENIED** WITH COMMENTS
  
 NOTE - A COMPREHENSIVE REVIEW COULD NOT BE DONE AT THIS
 TIME, AND ADDITIONAL PLAN REVIEW COMMENTS MAY BE
 GENERATED UPON THE RE-REVIEW OF SUBMITTED CORRECTIONS.
  
 1. PLEASE PROVIDE FOR PLUMBING REPAIR TUNNEL WORK
  
 A. A CLEAR AND LEGIBLE SANITARY RISER DIAGRAM SHALL BE
 SUBMITTED SHOWING ALL PIPE SIZES, CONNECTION POINTS TO
 EXISTING PIPING, HOW THE NEW PIPE WILL BE SUPPORTED,
 THE TYPE OF ADAPTERS USED FOR THE CONNECTIONS TO THE
 EXISTING PIPE, AND THE LOCATIONS OF REQUIRED CLEANOUTS.
 DETAILS AND BACKFILLING PROCEDURES SHALL BE SUBMITTED
 THAT CLEARLY SHOW HOW THE STRUCTURAL INTEGRITY OF THE
 CONCRETE SLAB WILL BE MAINTAINED DURING EXCAVATION AND
 BACKFILLING. STRUCTURAL FOAM IS NOT PERMITTED BELOW
 GROUND PER THE 2020 FLORIDA BUILDING CODE,
 RESIDENTIAL, AND SECTION 318.8 AND THE 2020 FLORIDA
 BUILDING CODE, BUILDING, SECTION 2603.9.
  
 B. A SIGNED AND SEALED LETTER FROM AN ENGINEER MAY BE
 REQUIRED TO CERTIFY THE STRUCTURAL INTEGRITY OF THE
 EXISTING SLAB.
  
 C. PLEASE INDICATE HOW THE PIPES WILL BE PROPERLY
 SUPPORTED UNDER THE HOME.
  
 D. THE BACKFILL UNDER THE SLAB SHALL BE TREATED FOR
 TERMITES PER THE 2020 FBC B SEC.1816.1 OR 2020 FBC R
 SEC. 318.1. A TERMITE CERTIFICATE SHALL BE ONSITE FOR A
 FINAL INSPECTION.
  
 2. PLEASE SHOW A CLEAN OUT EVERY TIME THE STRUCTURE IS
 ENTERED PER THE 2020 RES 3005.2.3 BUILDING DRAIN AND
 BUILDING SEWER JUNCTION.
  
 3. PLEASE PIPE SIZES IN FLAT DRAWINF PER THE WPB
 AMENDMENTS TO THE FBC SEC. 107.2.1 INFORMATION ON
 CONSTRUCTION DOCUMENTS.
  
 WHEN RESUBMITTING PLANS, PLEASE INDICATE THE REVISION &
 REMOVE ANY VOIDED SHEETS & REPLACE ANY NECESSARY PAGES.
 A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 HTTPS://CODES.ICCSAFE.ORG/CODES/FLORIDA
  
 LUIS A. CRESPO
 PLUMBING PLAN EXAMINER / INSPECTOR
 EMAIL: [email protected] OFFICE: 561 805-6720
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2021-02-03 Cont ID  
Sent By lcrespo Date 2021-02-03 Time 10:29 Rev Time 0.00
Received By lcrespo Date 2021-02-03 Time 10:29 Sent To  
Notes
***NONE***