Plan Review Details - Permit 21010992
| Plan Review Stops For Permit 21010992 |
| Review Stop |
AD |
ADDRESSING |
| Rev No |
2 |
Status |
P |
Date |
2021-04-15 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2021-04-15 |
Time |
16:37 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2021-04-15 |
Time |
16:36 |
Sent To |
|
|
| Notes |
| 2021-04-15 16:37:56 | BLDG A GIVEN THE ADDRESS OF 1249 PALM BEACH LAKES BLVD |
|
|
| Review Stop |
AD |
ADDRESSING |
| Rev No |
1 |
Status |
F |
Date |
2021-02-25 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2021-02-25 |
Time |
14:25 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2021-02-25 |
Time |
14:25 |
Sent To |
|
|
| Notes |
| 2021-02-25 14:26:36 | PLEASE INDICATE ON THE PLANS THE PRIMARY ENTRANCE ON | | | THE SITE PLAN, PLEASE EMAIL PLAN TO [email protected] |
|
|
| Review Stop |
AIPP |
ART IN PUBLIC PLACES |
| Rev No |
2 |
Status |
N |
Date |
2021-06-01 |
|
|
Cont ID |
|
| Sent By |
scwelter |
Date |
2021-06-01 |
Time |
15:13 |
Rev Time |
0.00 |
| Received By |
scwelter |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2021-06-01 15:15:05 | DEVELOPMENT IS UNDER THE $500,000. PUBLIC ART | | | REQUIREMENT N/A |
|
|
| Review Stop |
AIPP |
ART IN PUBLIC PLACES |
| Rev No |
1 |
Status |
F |
Date |
2021-03-01 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2021-03-01 |
Time |
10:06 |
Rev Time |
|
| Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2021-03-01 10:06:31 | ART IN PUBLIC PLACES NOW ARTLIFE 1/14/2021 | | | THE CITY OF WEST PALM BEACH ART IN PUBLIC PLACES | | | ORDINANCE REQUIREMENT THAT APPLIES TO ANY REMODEL OR | | | NEW CONSTRUCTION PROJECT FOR WHICH THE PERMIT | | | APPLICATION WAS SUBMITTED AFTER 6/29/14, AND THE TOTAL | | | PROJECT CONSTRUCTION COSTS ARE EQUAL TO OR GREATER THAN | | | $500,000 WILL NEED TO COMPLY WITH THIS ORDINANCE. | | | PER CITY OF WEST PALM BEACH ORDINANCE NO. 4504-14 | | | DIRECTED THAT THIS ORDINANCE BE REVIEWED AFTER ONE YEAR | | | OF IMPLEMENTATION AND THAT A REPORT ON THE | | | IMPLEMENTATION ALONG WITH ANY SUGGESTED REVISIONS TO | | | THE PROGRAM AND ORDINANCE BE BROUGHT BACK TO THE CITY | | | COMMISSION. | | | CHAPTER 78 -STREETS, SIDEWALKS AND PUBLIC PLACES, TO | | | AMEND AND RESTATE ARTICLE V - ART IN PUBLIC PLACES AS | | | ARTICLE V ? PUBLIC ART; AND TO AMEND AND RESTATE | | | ARTICLE I ? IN GENERAL, SECTION 78-10 ? MONUMENTS; | | | PROVIDING A SEVERABILITY AND CODIFICATION CLAUSE; | | | PROVIDING AN EFFECTIVE DATE; AND FOR OTHER PURPOSES. | | | CONSTRUCTION COSTS MEANS THE HARD COSTS ASSOCIATED WITH | | | THE CONSTRUCTION OF A PROJECT EXCLUDING REAL PROPERTY | | | ACQUISITION COSTS, ENVIRONMENTAL REMEDIATION COSTS, | | | DEMOLITION COSTS, GRADING AND SITE PREPARATION COSTS, | | | AND COSTS ASSOCIATED WITH SUBSEQUENT CHANGES IN | | | CONSTRUCTION CONTRACTS. CALCULATIONS SHALL BE BASED ON | | | CONSTRUCTION AND SITE IMPROVEMENT COSTS AS DECLARED ON | | | ALL BUILDING PERMIT APPLICATIONS FOR THE PROJECT. FOR | | | PURPOSES OF CALCULATING THE PUBLIC ART ASSESSMENT, | | | CONSTRUCTION COSTS SHALL INCLUDE, BUT NOT BE LIMITED | | | TO, ALL BUILDING, PLUMBING, MECHANICAL, AND ELECTRICAL | | | PERMIT APPLICATIONS FOR THE PROJECT. | | | EXTERIOR MEANS ANY PLACE, PUBLIC OR PRIVATE, OUTDOOR | | | AND EXTERIOR TO BUILDINGS OR STRUCTURES AND EXPOSED TO | | | PUBLIC VIEW, INCLUDING, BUT NOT LIMITED TO, BUILDINGS, | | | PARKS, RIGHT-OF-WAY MEDIANS AND OPEN SPACES. | | | LOCAL ARTIST IS AN ARTIST, AS DEFINED IN THIS SECTION, | | | WHO RESIDES IN PALM BEACH COUNTY. | | | MASTER PLAN MEANS THE PUBLIC ART MASTER PLAN, AS | | | APPROVED BY THE CITY COMMISSION FROM TIME TO TIME. | | | MURAL MEANS ANY DRAWING, ARTWORK, INSCRIPTION, OR | | | MARKING THAT IS MARKED, ETCHED, DRAWN OR PAINTED ON ANY | | | BUILDING OR STRUCTURE. | | | PROJECT MEANS NEW CONSTRUCTION, RENOVATION WORK, OR | | | FA?ADE IMPROVEMENTS REQUIRING A BUILDING PERMIT WHERE | | | 50 PERCENT OR MORE OF A BUILDING IS BEING MODIFIED, | | | RENOVATED, EXPANDED, REBUILT OR IMPROVED BY | | | CONSTRUCTION. | | | FOR CONTACT INFORMATION PLEASE CONTACT: | | | MS. SYBILLE WELTER ART IN PUBLIC PLACES / ARTLIFE | | | COORDINATOR 822-1515 E-MAIL: [email protected] | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2021-06-24 |
Time |
09:45 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2021-06-24 |
Time |
08:26 |
Sent To |
|
|
| Notes |
| 2021-06-24 09:32:21 | BUILDING PROVISO: RESPONSE LETTER NOTES CIVIL DRAWINGS | | | ARE ALREADY APPROVED. PLEASE NOTE THE ENGINEERING | | | DEPARTMENT DOES NOT HAVE LICENSED REVIEWERS FOR | | | ACCESSIBILITY. IN THE FIELD STRIPPING SHALL COMPLY WITH | | | ACCESSIBLE PARKING SPACE / STALL PAINTING. 2020 | | | ACCESSIBILITY CODE SECTION 502.2 VEHICLE SPACES. EACH | | | PARKING SPACE MUST BE AT LEAST 12 FEET WIDE, SHALL BE | | | MARKED TO DEFINE THE WIDTH, AND SHALL HAVE AN ADJACENT | | | ACCESS AISLE COMPLYING WITH 502.3. | | | ADVISORY 502.3.3MARKING THE METHOD AND MARKING OF COLOR | | | OF MARKING ARE NOT SPECIFIED BY THESE REQUIREMENTS BUT | | | MAY BE ADDRESSED BY STATE OR LOCAL LAWS OR REGULATIONS. | | | WEST PALM MUNI-CODE ARTICLE XV PARKING DETAIL, 94-485 | | | ILLUSTRATES WITH MEASUREMENTS FOR DOUBLE STRIPE STALL | | | PAINTING. | | | 502.4 ACCESS AISLE & PARKING SPACE SAME LEVEL/ 502.4, | | | FLOOR AND GROUND SURFACES. PARKING SPACES AND THE | | | ACCESS AISLES SERVING THEM SHALL COMPLY WITH 302. | | | ACCESS AISLES SHALL BE AT THE SAME LEVEL AS THE PARKING | | | SPACES THEY SERVE. | | | CHANGES IN LEVEL ARE NOT PERMITTED. EXCEPTION: SLOPES | | | NOT GREATER THAN 1:48 SHALL BE PERMITTED. GIVE | | | ELEVATION MARKERS TO SHOW COMPLIANCE. | | | | | | JAMES A. WITMER BN, PX, SFP, CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2021-05-25 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2021-05-25 |
Time |
08:56 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2021-05-24 |
Time |
16:01 |
Sent To |
|
|
| Notes |
| 2021-05-25 08:49:55 | WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION | | | SERVICES/ BUILDING DIVISION | | | 2020 FBC- BUILDING PLAN REVIEW | | | W. P. B. PERMIT: 21010992 | | | ADD: 1225 PALM BEACH LAKES BLVD. | | | CONT: VAN NESS & CALLAWAY CONSTRUCTION | | | TEL: 561-371-0615 | | | E-MAIL: [email protected] | | | | | | 2020 FLORIDA BUILDING CODE W 2020 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION | | | | | | 2ND REVIEW | | | DATE: TUESDAY MAY 25TH/ 2021 | | | ACTION: DENIED | | | | | | 1) 2ND REQUEST. A CURRENT SURVEY DOES NOT SHOW THE | | | LOCATION OF THE PROPOSED BUILDING, WITHOUT THE LOCATION | | | OF THE PROPOSED BUILDING THE SURVEY IS USELESS. WE ARE | | | TRYING TO SEE HOW COMPLIANCE WITH SECTION 503.2.1, | | | 504.4 AND 506.2, TABLE 602, 705, TABLE 705.8, & SECTION | | | 716 OF THE 2020 FBC-B. | | | 1ST ROUND COMMENTS. THE TITLE-SHEET DOES NOT LIST A | | | CURRENT SURVEY, OR SITE PLAN. THE TITLE-SHEET LIST | | | THERE ARE CIVIL PLANS UNDER SEPARATE COVER. THE | | | APPLICATION MYGEONAV SHOWS THERE IS A BUILDING AND | | | PARKING LOT AT THIS LOCATION ALREADY. PLEASE PROVIDE AN | | | UP TO DATE SURVEY SHOWING THE PRESENT BUILDING AND THE | | | LOCATION OF THE PROPOSED BUILDING. PLEASE SHOW HOW | | | COMPLIANCE WITH SECTION 503.2.1 OF THE 2020 | | | FBC-BUILDING ARE GOING TO BE ACCOMPLISHED. TWO | | | BUILDINGS ON THE SAME LOT SHALL BE REGULATED AS | | | SEPARATE BUILDINGS OR SHALL BE CONSIDERED AS PORTIONS | | | OF ONE BUILDING WHERE THE BUILDING HEIGHT, NUMBER OF | | | STORIES OF EACH BUILDING AND THE AGGREGATE BUILDING | | | AREA OF THE BUILDINGS ARE WITHIN THE LIMITATIONS | | | SPECIFIED IN SECTIONS 504.4 AND 506.2. OR. TWO | | | BUILDINGS ON THE SAME LOT ARE CONSIDERED INDEPENDENTLY | | | FOR COMPLIANCE WITH THE REQUIREMENTS OF THE CODE. | | | SECTION 705.3 REQUIRES THAT WHEN TWO BUILDINGS ARE ON | | | THE SAME LOT, AN IMAGINARY LINE IS ASSUMED BETWEEN THE | | | BUILDINGS. THIS IS USED TO DETERMINE THE APPROPRIATE | | | EXTERIOR WALL FIRE-RESISTANCE RATINGS IN TABLE 602, | | | EXTERIOR WALL REQUIREMENTS OF SECTION 705, PROJECTION | | | REQUIREMENTS OF SECTION 705.2 AND OPENING PROTECTIVE | | | RATINGS AND REQUIREMENTS SET FORTH IN TABLE 705.8 AND | | | SECTION 716 (ALSO SEE THE COMMENTARY FOR THE DEFINITION | | | OF FIRE SEPARATION DISTANCE). | | | | | | 2-3) COMPLIED. | | | | | | 4A) 2ND REQUEST. THE PLANS SUBMITTED DO NOT COMPLY WITH | | | THE NORMAL NAMING CONVENTION FOR PLANS. THIS IS THE | | | FIRST TIME I?VE SEEN ALL OF THE 100 SERIES SHEETS | | | GROUPED TOGETHER FOR ALL TRADES THEN ALL 200 SERIES | | | SHEETS FOR ALL TRADES. ALL ARCHITECTURAL PLANS GROUPED | | | TOGETHER NUMERICALLY, ALL ELECTRICAL PLANS GROUPED | | | TOGETHER NUMERICALLY, ALL MECHANICAL PLANS GROUPED | | | TOGETHER NUMERICALLY, PLUMBING AND GAS PLANS GROUPED | | | TOGETHER NUMERICALLY AND THEN LAST THE STRUCTURAL PLANS | | | GROUPED TOGETHER NUMERICALLY. | | | 107.2.1.3. QUALITY OF PLANS. THE BUILDING OFFICIAL MAY | | | ESTABLISH THROUGH DEPARTMENT POLICY OTHER STANDARDS FOR | | | THE PLANS AND SPECIFICATIONS IN ORDER TO PROVIDE | | | CONFORMITY TO ITS RECORD RETENTION PROGRAM. THIS POLICY | | | MAY INCLUDE SUCH THINGS AS MINIMUM SIZE, SHAPE, | | | CONTRAST, CLARITY, OR OTHER ITEMS RELATED TO RECORD | | | MANAGEMENT. ELECTRONIC MEDIA MUST BE COMPATIBLE WITH | | | THE ARCHIVE REQUIREMENTS OF FLORIDA STATUTES. | | | 4B) COMPLIED. 2ND REVIEW NEW COMMENT STRUCTURAL SHEETS | | | IN THIS SUBMISSION. | | | 1ST ROUND OF COMMENTS. THE TITLE SHEET INDICATES IN | | | THIS SUBMISSION OF PLANS INCLUDED IN THIS SET OF PLANS | | | THERE SHOULD BE STRUCTURAL SHEETS S-1.0 -S4.4, 8 | | | STRUCTURAL SHEETS. THESE SHEETS WERE NOT UPLOADED AND | | | COULD NOT BE REVIEWED. 2020 FBC-BUILDING. QUESTIONABLE | | | SOILS. 1803.5.2 QUESTIONABLE SOIL. WHERE THE | | | CLASSIFICATION, STRENGTH OR COMPRESSIBILITY OF THE SOIL | | | IS IN DOUBT OR WHERE A LOAD-BEARING VALUE SUPERIOR TO | | | THAT SPECIFIED IN THIS CODE IS CLAIMED, THE BUILDING | | | OFFICIAL SHALL BE PERMITTED TO REQUIRE THAT A | | | GEOTECHNICAL INVESTIGATION BE CONDUCTED. | | | | | | | | | 5) 2ND REQUEST, PLEASE TELL ME ON WHICH SHEETS THE WIND | | | DESIGN AND ASSOCIATED PRESSURES CAN BE FOUND. MISSING | | | STRUCTURAL SHEETS. 2020 FBC-B 1603.1.4 WIND DESIGN | | | DATA. THE FOLLOWING INFORMATION RELATED TO WIND LOADS | | | SHALL BE SHOWN, REGARDLESS OF WHETHER WIND LOADS GOVERN | | | THE DESIGN OF THE LATERAL FORCE-RESISTING SYSTEM OF THE | | | STRUCTURE: | | | | | | 5.1. ULTIMATE DESIGN WIND SPEED, VULT, (3-SECOND GUST), | | | MILES PER HOUR AND NOMINAL DESIGN WIND SPEED, VASD, AS | | | DETERMINED IN ACCORDANCE WITH SECTION 1609.3.1. | | | | | | 5.2. RISK CATEGORY. | | | | | | 5.3. WIND EXPOSURE. APPLICABLE WIND DIRECTION IF MORE | | | THAN ONE WIND EXPOSURE IS UTILIZED. TABLE 1609.7.2. | | | HEIGHT AND EXPOSURE. ASCE 7-16 TABLE 30.3.1. | | | | | | 5.4. APPLICABLE INTERNAL PRESSURE COEFFICIENT. | | | | | | 5.5. DESIGN WIND PRESSURES TO BE USED FOR EXTERIOR | | | COMPONENTS AND CLADDING MATERIALS SPECIFICALLY DESIGNED | | | BY THE REGISTERED DESIGN PROFESSIONAL RESPONSIBLE FOR | | | THE DESIGN OF THE STRUCTURE, PSF. | | | | | | 5.6. TABLE 1609.7(2) ADJUSTMENT FACTORS FOR HEIGHT & | | | EXPOSURE. PROVIDE THE MEAN ROOF HEIGHT FOR THE | | | BUILDING. ASCE 7-16 TABLE 30.3.1. 1609.3.1 WIND SPEED | | | CONVERSION VULT TO VASD. | | | | | | 6) 2ND REQUEST. MISSING THE SOILS REPORT, IT IS NOT | | | LISTED IN THE DOCUMENT FOLDER. | | | 2020 WEST PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING | | | CODE, CHAPTER 1, ADMINISTRATION 107.3.5 MINIMUM PLAN | | | REVIEW CRITERIA. 107.3.5 MINIMUM PLAN REVIEW CRITERIA | | | FOR BUILDINGS AND OR STRUCTURES. | | | 107.3.5.1 COMMERCIAL BUILDINGS | | | 107.3.5.1.1. BUILDING | | | MISSING CODE DATA: | | | STRUCTURAL REQUIREMENTS SHALL INCLUDE: | | | SOIL CONDITIONS/ANALYSIS | | | TERMITE PROTECTION | | | DESIGN LOADS | | | WIND REQUIREMENTS | | | BUILDING ENVELOPE | | | WALL SYSTEMS | | | FLOOR SYSTEMS | | | ROOF SYSTEMS | | | MATERIALS SHALL BE REVIEWED AND SHALL AT A MINIMUM | | | INCLUDE THE FOLLOWING: | | | WOOD | | | STEEL | | | ALUMINUM | | | CONCRETE | | | PLASTIC | | | GLASS | | | MASONRY | | | GYPSUM BOARD AND PLASTER | | | INSULATING (MECHANICAL) | | | ROOFING | | | INSULATION | | | | | | 7) COMPLIED. WOOD TRUSSES. | | | | | | 8) COMPLIED. | | | | | | 9A) COMPLIED. SHEET A6.0 CONSTRUCTION DETAIL # 14. | | | | | | 9B) 2ND REQUEST. THE DETAIL ALSO STATES THIS CURB TYPE | | | IS A KNOCK-DOWN FLAT METAL CURB BY RTU SUPPLIER. PLEASE | | | PROVIDE THE ATTACHMENT OF THE ROOF CURB TO THE MWFRS | | | (MAIN WIND FORCE RESISTING SYSTEM) AND THE RTU UNIT TO | | | THE CURB. | | | 2020 FBC-M- 301.15 WIND RESISTANCE. MECHANICAL | | | EQUIPMENT, APPLIANCES AND SUPPORTS THAT ARE EXPOSED TO | | | WIND SHALL BE DESIGNED AND INSTALLED TO RESIST THE WIND | | | PRESSURES DETERMINED IN ACCORDANCE WITH THE FLORIDA | | | BUILDING CODE, BUILDING. | | | FBC-B-1609.6.4.4.1 COMPONENTS AND CLADDING. WIND | | | PRESSURE FOR EACH COMPONENT OR CLADDING ELEMENT IS TO | | | BE DESIGNED FOR WIND PRESSURES COMPONENTS AND | | | ATTACHMENTS. | | | LATERAL FORCE-RESISTING SYSTEM. FOR ALL ROOF TOP | | | EQUIPMENT, CURBS, FANS OR A/C STANDS, AND OR VENTS, | | | DETAILED ATTACHMENT TO THE ROOF FRAMING & DECK AS WELL | | | AS FROM THE CURB OR ROOF STAND TO THE EQUIPMENT ABOVE. | | | 2020 FBC-B 1604.4 ANALYSIS. LOAD EFFECTS ON STRUCTURAL | | | MEMBERS AND THEIR CONNECTIONS SHALL BE DETERMINED BY | | | METHODS OF STRUCTURAL ANALYSIS THAT TAKE INTO ACCOUNT | | | EQUILIBRIUM, GENERAL STABILITY, GEOMETRIC COMPATIBILITY | | | AND BOTH SHORT- AND LONG-TERM MATERIAL PROPERTIES. | | | EVERY STRUCTURE SHALL BE DESIGNED TO RESIST THE | | | OVERTURNING EFFECTS CAUSED BY THE LATERAL FORCES | | | SPECIFIED IN THIS CHAPTER. SEE SECTION 1609 FOR WIND | | | LOADS. | | | | | | 9C) 2ND REQUEST. SHEET A6.0 DETAIL 18 SHOWS ROOF TOP | | | EXHAUST FANS AND CURBS SHEET M-3.1 SHOWS STRATOVENT | | | ROOF TOP EXHAUST FAN DETAILS, NO ANCHORING DETAILS. NO | | | ANCHORING DETAILS FOUND IN THE STRUCTURAL SHEETS. SEE | | | COMMENT 9B REPEATED. | | | | | | 10) COMPLIED. SHEET ADA.1: THE DETAILS FOR THE TOILET | | | PAPER DISPENSER. | | | | | | | | | 11) 2ND REQUEST. SHEET ADA 2 HAS A DETAIL CIRCLED ON | | | SHEET ADA1.2 DETAIL 11. THERE IS NO SUCH SHEET IN THIS | | | SET OF DRAWINGS. SHEET ADA.2 INDICATES AA ENLARGED | | | ACCESSIBLE PARKING DETAIL AND ACCESS AISLE, DETAIL 16 | | | OF ADA1.1. THIS SHEET NOT INCLUDED IN THIS SET OF PLANS | | | NOR THE INDEX SHEET. | | | ACCESSIBLE PARKING SPACE / STALL PAINTING. | | | 2020 ACCESSIBILITY CODE SECTION 502.2 VEHICLE SPACES. | | | EACH PARKING SPACE MUST BE AT LEAST 12 FEET WIDE, SHALL | | | BE MARKED TO DEFINE THE WIDTH, AND SHALL HAVE AN | | | ADJACENT ACCESS AISLE COMPLYING WITH 502.3. | | | ADVISORY 502.3.3MARKING THE METHOD AND MARKING OF COLOR | | | OF MARKING ARE NOT SPECIFIED BY THESE REQUIREMENTS BUT | | | MAY BE ADDRESSED BY STATE OR LOCAL LAWS OR REGULATIONS. | | | WEST PALM MUNI-CODE ARTICLE XV PARKING DETAIL, 94-485 | | | ILLUSTRATES WITH MEASUREMENTS FOR DOUBLE STRIPE STALL | | | PAINTING. | | | | | | 502.4 ACCESS AISLE & PARKING SPACE SAME LEVEL/ 502.4, | | | FLOOR AND GROUND SURFACES. PARKING SPACES AND THE | | | ACCESS AISLES SERVING THEM SHALL COMPLY WITH 302. | | | ACCESS AISLES SHALL BE AT THE SAME LEVEL AS THE PARKING | | | SPACES THEY SERVE. | | | CHANGES IN LEVEL ARE NOT PERMITTED. EXCEPTION: SLOPES | | | NOT GREATER THAN 1:48 SHALL BE PERMITTED. GIVE | | | ELEVATION MARKERS TO SHOW COMPLIANCE. | | | | | | 12) 2ND REQUEST.!!!!! THE SUBMITTED PRODUCT APPROVALS | | | WERE NOT REVIEWED THIS CYCLE SINCE THERE WERE NO | | | STRUCTURAL DRAWINGS WHICH WOULD HAVE HAD THE WIND | | | DESIGN CRITERIA LISTED AND THE ASSOCIATED PRESSURES. | | | | | | 12A) COMPONENTS & CLADDING. 2020 FBC-B 1609.1.2 | | | PROTECTION OF OPENINGS, 1609.6.4.4.1 COMPONENTS & | | | CLADDING. FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS, | | | ADMINISTRATIVE CODE 61G20-3.005, RULE 9N-3 NOV. 01/ | | | 2010 (31) SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION | | | SYSTEMS THAT WILL REQUIRE PRODUCT APPROVALS: | | | (31)(A) EXTERIOR DOORS, MULLIONS & ROOF HATCHES. | | | (B) WINDOWS & MULLIONS | | | (C) PANEL WALLS: STOREFRONTS, CURTAIN WALLS, WALL | | | LOUVERS, EFIS SYSTEMS, | | | (D) ROOFING PRODUCTS AND ASSEMBLIES, LIGHTWEIGHT | | | CONCRETE INSULATION, ROOF TOP VENTILATORS & FANS | | | (G) PRE-ENGINEERED A/C STANDS | | | | | | 12B) W. P. B. 107.3.4. PRODUCT APPROVALS. THOSE | | | PRODUCTS WHICH ARE REGULATED BY FLORIDA ADMINISTRATIVE | | | CODE RULE 61G20 SHALL BE REVIEWED AND APPROVED IN | | | WRITING (SHOP DRAWING STAMP OF APPROVAL) BY THE | | | DESIGNER OF RECORD PRIOR TO SUBMITTAL FOR | | | JURISDICTIONAL APPROVAL. | | | FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR | | | SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS, | | | SHOP DRAWINGS ETC. | | | | | | 12C) 107.3.4.2 DEFERRED SUBMITTALS. FOR THE PURPOSES OF | | | THIS SECTION, DEFERRED SUBMITTALS ARE DEFINED AS THOSE | | | PORTIONS OF THE DESIGN THAT ARE NOT SUBMITTED AT THE | | | TIME OF THE APPLICATION AND THAT ARE TO BE SUBMITTED TO | | | THE BUILDING OFFICIAL WITHIN A SPECIFIED PERIOD. | | | DEFERRAL OF ANY SUBMITTAL ITEMS SHALL HAVE THE PRIOR | | | APPROVAL OF THE BUILDING OFFICIAL. THE REGISTERED | | | DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE SHALL LIST | | | THE DEFERRED SUBMITTALS ON THE CONSTRUCTION DOCUMENTS | | | FOR REVIEW BY THE BUILDING OFFICIAL. | | | | | | DOCUMENTS FOR DEFERRED SUBMITTAL ITEMS SHALL BE | | | SUBMITTED TO THE REGISTERED DESIGN PROFESSIONAL IN | | | RESPONSIBLE CHARGE WHO SHALL REVIEW THEM AND FORWARD | | | THEM TO THE BUILDING OFFICIAL WITH A NOTATION | | | INDICATING THAT THE DEFERRED SUBMITTAL DOCUMENTS HAVE | | | BEEN REVIEWED AND FOUND TO BE IN GENERAL CONFORMANCE TO | | | THE DESIGN OF THE BUILDING. THE DEFERRED SUBMITTAL | | | ITEMS SHALL NOT BE INSTALLED UNTIL THE DEFERRED | | | SUBMITTAL DOCUMENTS HAVE BEEN APPROVED BY THE BUILDING | | | OFFICIAL. | | | | | | 12D) IDENTIFY GLAZING/ MULLIONS. PLEASE IDENTIFY ON THE | | | PRODUCT APPROVAL BEFORE SUBMITTING TO DESIGNER OF | | | RECORD AND BEFORE SUBMISSION TO THE BUILDING | | | DEPARTMENT. FOR ALL PRODUCTS WITH GLAZING, PLEASE | | | IDENTIFY THE OPENING WIDTH & HEIGHT, TYPE OF GLAZING, | | | MULLION SIZE, LENGTH IF UNREINFORCED OR REINFORCED | | | INFORMATION IF REQUIRED, ATTACHMENTS AND ASSOCIATE | | | PRESSURES FOR EACH OPENING SIZE. 2020 FBC-B 1405.13.1 | | | INSTALLATION. WINDOWS AND DOORS SHALL BE INSTALLED IN | | | ACCORDANCE WITH APPROVED MANUFACTURER?S INSTRUCTIONS. | | | FASTENER SIZE AND SPACING SHALL BE PROVIDED IN SUCH | | | INSTRUCTIONS AND SHALL BE CALCULATED BASED ON MAXIMUM | | | LOADS AND SPACING USED IN THE TESTS. | | | | | | 12E) EFIS SYSTEMS: PLEASE PROVIDE THE PRODUCT APPROVAL | | | FOR THE SYSTEM TO BE INSTALLED. PLEASE ALSO PROVIDE THE | | | MANUFACTURERS INSTALLATION BROCHURE PROVIDING | | | COMPLIANCE WITH 2014 FBC-B SECTIONS; | | | 1408.2 PERFORMANCE CHARACTERISTICS. | | | 1408.2 PERFORMANCE CHARACTERISTICS. | | | 1408.3 STRUCTURAL DESIGN. | | | 1408.4 WEATHER RESISTANCE. | | | 1408.4.1 EIFS WITH DRAINAGE. | | | 408.4.1.1 WATER-RESISTIVE BARRIER. | | | 1408.5 INSTALLATION. | | | | | | 12F) ROOFING: FOR ALL ROOFING PRODUCTS PLEASE IDENTIFY | | | ALL ROOFING SUB-SYSTEMS AND THEIR ASSOCIATED PRESSURES | | | FOR ROOF ZONE # 1. REVIEW THE PRODUCT APPROVAL | | | LIMITATIONS, IF ENHANCED FASTENING IS ALLOWED FOR ROOF | | | ZONES 2 & 3. FASTENER DENSITIES SHALL BE INCREASED FOR | | | BOTH INSULATION & THE BASE SHEET AS CALCULATED IN | | | COMPLIANCE WITH ROOFING APPLICATION STANDARDS RAS 117. | | | CALCULATION PREPARED, SIGNED AND SEALED BY A FLORIDA | | | REGISTERED PROFESSIONAL ENGINEER OR REGISTERED | | | ARCHITECT. 1609.6.4.4.1 COMPONENTS & CLADDING. | | | | | | 12G) 2020 FBC-B 1011.16 LADDERS. PERMANENT LADDERS | | | SHALL NOT SERVE AS A PART OF THE MEANS OF EGRESS FROM | | | OCCUPIED SPACES WITHIN A BUILDING. PERMANENT LADDERS | | | SHALL BE PERMITTED TO PROVIDE ACCESS TO THE FOLLOWING | | | AREAS: | | | 1.SPACES FREQUENTED ONLY BY PERSONNEL FOR MAINTENANCE, | | | REPAIR OR MONITORING OF EQUIPMENT. | | | 5.NONOCCUPIED ROOFS THAT ARE NOT REQUIRED TO HAVE | | | STAIRWAY ACCESS IN ACCORDANCE WITH SECTION | | | 1011.12.1. | | | 6.LADDERS SHALL BE CONSTRUCTED IN ACCORDANCE WITH | | | SECTION 306.5 OF THE FLORIDA BUILDING CODE, | | | MECHANICAL. | | | LADDERS SHALL COMPLY WITH THE FOLLOWING MINIMUM DESIGN | | | CRITERIA: | | | 1. THE SIDE RAILING SHALL EXTEND ABOVE THE PARAPET OR | | | ROOF EDGE NOT LESS THAN 30 INCHES (762 MM). | | | 2. LADDERS SHALL HAVE RUNG SPACING NOT TO EXCEED 14 | | | INCHES (356 MM) ON CENTER. | | | 3. LADDERS SHALL HAVE A TOE SPACING NOT LESS THAN | | | 6-INCHES (152 MM) DEEP. | | | 4. THERE SHALL BE A MINIMUM OF 18 INCHES (457 MM) | | | BETWEEN RAILS. | | | 5. RUNGS SHALL HAVE A MINIMUM 0.75-INCH (19 MM) | | | DIAMETER AND BE CAPABLE OF WITHSTANDING A 300-POUND | | | (136.1 KG) LOAD. | | | 6. LADDERS OVER 30 FEET (9144 MM) IN HEIGHT SHALL BE | | | PROVIDED WITH OFFSET SECTIONS AND LANDINGS CAPABLE OF | | | WITHSTANDING 100 POUNDS PER SQUARE FOOT (488.2 KG/M2). | | | 7. LADDERS SHALL BE PROTECTED AGAINST CORROSION BY | | | APPROVED MEANS. CATWALKS INSTALLED TO PROVIDE THE | | | REQUIRED ACCESS SHALL BE NOT LESS THAN 24-INCHES (610 | | | MM) WIDE AND SHALL HAVE RAILINGS AS REQUIRED FOR | | | SERVICE PLATFORMS. | | | | | | 12H) ROOF TOP HATCHES/ ROOF ACCESS/ 2020 FBC-B | | | 1011.12.2. IN BUILDINGS THAT DO NOT HAVE AN OCCUPIED | | | ROOF SHALL BE PERMITTED TO BE A ROOF HATCH OR TRAP DOOR | | | NOT LESS THAN 16 SQUARE FEET IN AREA AND HAVING A | | | MINIMUM DIMENSION OF 2 FEET. | | | | | | 13) 2ND REQUEST. IMPACT FEES - DIGITAL SUBMITTALS: | | | PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE | | | DIGITALLY VIA PROJECT DOX UPON NOTIFICATION BY THIS | | | OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST | | | FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE | | | OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL | | | IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME | | | THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM | | | CAN BE FOUND AT: | | | HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINISTRAT | | | ION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF UPON | | | APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE RECEIPT TO | | | YOUR PROJECT OR EMAIL IT TO [email protected] . | | | | | | 14) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW | | | COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | | THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR | | | PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | PLEASE NOTE WITH THE LACK OF INFORMATION FOR THIS | | | REVIEW, SUBSEQUENT REMARKS MAYBE MADE IN THE NEXT | | | REVIEW CYCLE. | | | | | | PLEASE NOTE WE ARE WORKING FROM HOME BECAUSE OF COVID | | | 19 | | | IF YOU WOULD LIKE TO CONTACT ME, MY CELL NUMBER IS | | | 561-718-9724. | | | WORKING HOURS ARE MON.- WED. 8:00 AM- NOON. PART-TIME/ | | | RETIRED. | | | | | | JAMES A. WITMER BN, PX, SFP, CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT | | | 401 CLEMATIS ST. WEST PALM BEACH. FL 33402 | | | TEL: 561-805-6717 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | DEVELOPMENT SERVICES HOME PAGE | | | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP | | | | | | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS | | | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS | | | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO | | | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE | | | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2021-03-01 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2021-03-01 |
Time |
12:45 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2021-03-01 |
Time |
10:00 |
Sent To |
|
|
| Notes |
| 2021-03-01 12:45:50 | WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION | | | SERVICES/ BUILDING DIVISION | | | 2020 FBC- BUILDING PLAN REVIEW | | | W. P. B. PERMIT: 21010992 | | | ADD: 1225 PALM BEACH LAKES BLVD. | | | CONT: VAN NESS & CALLAWAY CONSTRUCTION | | | TEL: 561-371-0615 | | | E-MAIL: [email protected] | | | | | | 2020 FLORIDA BUILDING CODE W 2020 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION | | | | | | 1ST REVIEW | | | DATE: MONDAY MARCH 01ST/ 2021 | | | ACTION: DENIED | | | | | | 1) THE TITLE-SHEET DOES NOT LIST A CURRENT SURVEY, OR | | | SITE PLAN. THE TITLE-SHEET LIST THERE ARE CIVIL PLANS | | | UNDER SEPARATE COVER. THE APPLICATION MYGEONAV SHOWS | | | THERE IS A BUILDING AND PARKING LOT AT THIS LOCATION | | | ALREADY. PLEASE PROVIDE AN UP TO DATE SURVEY SHOWING | | | THE PRESENT BUILDING AND THE LOCATION OF THE PROPOSED | | | BUILDING. PLEASE SHOW HOW COMPLIANCE WITH SECTION | | | 503.2.1 OF THE 2020 FBC-BUILDING ARE GOING TO BE | | | ACCOMPLISHED. TWO BUILDINGS ON THE SAME LOT SHALL BE | | | REGULATED AS SEPARATE BUILDINGS OR SHALL BE CONSIDERED | | | AS PORTIONS OF ONE BUILDING WHERE THE BUILDING HEIGHT, | | | NUMBER OF STORIES OF EACH BUILDING AND THE AGGREGATE | | | BUILDING AREA OF THE BUILDINGS ARE WITHIN THE | | | LIMITATIONS SPECIFIED IN SECTIONS 504.4 AND 506.2. OR. | | | TWO BUILDINGS ON THE SAME LOT ARE CONSIDERED | | | INDEPENDENTLY FOR COMPLIANCE WITH THE REQUIREMENTS | | | OF THE CODE. SECTION 705.3 REQUIRES THAT WHEN TWO | | | BUILDINGS ARE ON THE SAME LOT, AN ?IMAGINARY? LINE IS | | | ASSUMED BETWEEN THE BUILDINGS. THIS IS USED TO | | | DETERMINE THE APPROPRIATE EXTERIOR WALL FIRE-RESISTANCE | | | RATINGS IN TABLE 602, EXTERIOR WALL REQUIREMENTS OF | | | SECTION 705, PROJECTION REQUIREMENTS OF SECTION 705.2 | | | AND OPENING PROTECTIVE RATINGS AND REQUIREMENTS SET | | | FORTH IN TABLE 705.8 AND SECTION 716 (ALSO SEE THE | | | COMMENTARY FOR THE DEFINITION OF ?FIRE SEPARATION | | | DISTANCE?). | | | | | | 2) WITH 2 BUILDINGS ON THE SAME LOT EACH BUILDING IS | | | REQUIRED TO HAVE THEIR OWN SEPARATE ADDRESS AND A SITE | | | ADDRESS AS WELL. | | | 2020 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION 107.2.1 INFORMATION ON CONSTRUCTION | | | DOCUMENTS. CONSTRUCTION DOCUMENTS SHALL BE OF | | | SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE AND | | | EXTENT OF THE WORK PROPOSED. | | | | | | | | | | | | 3) THIS ROUND OF REVIEW, THERE WERE NO DOCUMENTS | | | SUBMITTED FOR THE ENERGY REVIEW UNDER THE 2020 | | | FBC-ENERGY. 2020 ENERGY CODE SECTION C401.2 | | | APPLICATION. | | | COMMERCIAL BUILDINGS SHALL COMPLY WITH ONE OF THE | | | FOLLOWING: | | | 3.1. THE REQUIREMENTS OF ANSI/ASHRAE/IESNA 90.1, | | | EXCLUDING SECTION 9.4.1.1(G) OF THE STANDARD. | | | 3.2. THE REQUIREMENTS OF SECTIONS C402 THROUGH C405. IN | | | ADDITION, COMMERCIAL BUILDINGS SHALL COMPLY WITH | | | SECTION C406 AND TENANT SPACES SHALL COMPLY WITH | | | SECTION C406.1.1. | | | 3.3. THE REQUIREMENTS OF SECTIONS C402.5, C403.2, C404, | | | C405.2, C405.3, C405.5, C405.6 AND C407. THE BUILDING | | | ENERGY COST SHALL BE EQUAL TO OR LESS THAN 85 PERCENT | | | OF THE STANDARD REFERENCE DESIGN BUILDING. | | | | | | 4) THE TITLE SHEET INDICATES IN THIS SUBMISSION OF | | | PLANS INCLUDED IN THIS SET OF PLANS THERE SHOULD BE | | | STRUCTURAL SHEETS S-1.0 -S4.4, 8 STRUCTURAL SHEETS. | | | THESE SHEETS WERE NOT UPLOADED AND COULD NOT BE | | | REVIEWED. 2020 FBC-BUILDING. QUESTIONABLE SOILS. | | | 1803.5.2 QUESTIONABLE SOIL. WHERE THE CLASSIFICATION, | | | STRENGTH OR COMPRESSIBILITY OF THE SOIL IS IN DOUBT OR | | | WHERE A LOAD-BEARING VALUE SUPERIOR TO THAT SPECIFIED | | | IN THIS CODE IS CLAIMED, THE BUILDING OFFICIAL SHALL BE | | | PERMITTED TO REQUIRE THAT A GEOTECHNICAL INVESTIGATION | | | BE CONDUCTED. | | | | | | | | | 5) MISSING STRUCTURAL SHEETS. 2020 FBC-B 1603.1.4 WIND | | | DESIGN DATA. THE FOLLOWING INFORMATION RELATED TO WIND | | | LOADS SHALL BE SHOWN, REGARDLESS OF WHETHER WIND LOADS | | | GOVERN THE DESIGN OF THE LATERAL FORCE-RESISTING SYSTEM | | | OF THE STRUCTURE: | | | | | | 5.1. ULTIMATE DESIGN WIND SPEED, VULT, (3-SECOND GUST), | | | MILES PER HOUR AND NOMINAL DESIGN WIND SPEED, VASD, AS | | | DETERMINED IN ACCORDANCE WITH SECTION 1609.3.1. | | | | | | 5.2. RISK CATEGORY. | | | | | | 5.3. WIND EXPOSURE. APPLICABLE WIND DIRECTION IF MORE | | | THAN ONE WIND EXPOSURE IS UTILIZED. TABLE 1609.7.2. | | | HEIGHT AND EXPOSURE. ASCE 7-16 TABLE 30.3.1. | | | | | | 5.4. APPLICABLE INTERNAL PRESSURE COEFFICIENT. | | | | | | 5.5. DESIGN WIND PRESSURES TO BE USED FOR EXTERIOR | | | COMPONENTS AND CLADDING MATERIALS SPECIFICALLY DESIGNED | | | BY THE REGISTERED DESIGN PROFESSIONAL RESPONSIBLE FOR | | | THE DESIGN OF THE STRUCTURE, PSF. | | | | | | 5.6. TABLE 1609.7(2) ADJUSTMENT FACTORS FOR HEIGHT & | | | EXPOSURE. PROVIDE THE MEAN ROOF HEIGHT FOR THE | | | BUILDING. ASCE 7-16 TABLE 30.3.1. 1609.3.1 WIND SPEED | | | CONVERSION VULT TO VASD. | | | | | | 6) 2020 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE, CHAPTER 1, ADMINISTRATION 107.3.5 | | | MINIMUM PLAN REVIEW CRITERIA. 107.3.5 MINIMUM PLAN | | | REVIEW CRITERIA FOR BUILDINGS AND OR STRUCTURES. | | | 107.3.5.1 COMMERCIAL BUILDINGS | | | 107.3.5.1.1. BUILDING | | | MISSING CODE DATA: | | | STRUCTURAL REQUIREMENTS SHALL INCLUDE: | | | SOIL CONDITIONS/ANALYSIS | | | TERMITE PROTECTION | | | DESIGN LOADS | | | WIND REQUIREMENTS | | | BUILDING ENVELOPE | | | WALL SYSTEMS | | | FLOOR SYSTEMS | | | ROOF SYSTEMS | | | MATERIALS SHALL BE REVIEWED AND SHALL AT A MINIMUM | | | INCLUDE THE FOLLOWING: | | | WOOD | | | STEEL | | | ALUMINUM | | | CONCRETE | | | PLASTIC | | | GLASS | | | MASONRY | | | GYPSUM BOARD AND PLASTER | | | INSULATING (MECHANICAL) | | | ROOFING | | | INSULATION | | | | | | 7) POSSIBLE REQUIREMENT, ARCHITECTURAL SHEETS SHOW WOOD | | | TRUSSES AND PLYWOOD SHEATHING. IF BAR JOIST AND METAL | | | DECK SYSTEM ARE USED. WELDED OR BOLTED CONNECTIONS. | | | THE CONTRACTOR IS REQUIRED TO PROVIDE WELD PROCEDURE | | | SPECIFICATIONS & WELDER OPERATOR PERFORMANCE | | | QUALIFICATION RECORDS IN ACCORDANCE WITH THE REFERENCED | | | STANDARDS AT TIME OF INSPECTION FOR FIELD WIELDING, ON | | | THE JOB-SITE WIELDING. THIRD PARTY CERTIFICATION WILL | | | BE REQUIRED. REPORTS SUBMITTED TO BUILDING INSPECTOR AT | | | TIME OF FRAMING INSPECTION. | | | 2020 FBC-B 2204.1 WELDING | | | 1. WELD PROCEDURES SPECIFICATIONS | | | 2. QUALIFICATIONS OF WELDING PERSONAL | | | 2017 FBC-B 2204.2 BOLTING. | | | IF FURTHER CLARIFICATION AND OR QUESTIONS IS REQUIRED, | | | PLEASE CONTACT THE CHIEF BUILDING INSPECTOR KEN CONRAD | | | AT 561-805-6666. | | | | | | 8) THE ROOF PLAN HAS A NOTE THE PRIMARY AND OVERFLOW | | | SCUPPER OPENINGS ARE TO BE SIZED PER U.P.C. APPENDIX D | | | AND LOCAL CODE REQUIREMENTS. PLEASE REVIEW IN THE 2020 | | | FBC-B SECTIONS: | | | 1503.4 ROOF DRAINAGE. UNLESS ROOFS ARE SLOPED TO DRAIN | | | OVER ROOF EDGES, DESIGN AND INSTALLATION OF ROOF | | | DRAINAGE SYSTEMS | | | SHALL COMPLY WITH SECTION 1503 AND THE FLORIDA BUILDING | | | CODE, PLUMBING, CHAPTER 11. | | | 1503.4.2.1 OVERFLOW SCUPPERS. AN OVERFLOW SCUPPER SHALL | | | BE SIZED IN ACCORDANCE WITH THE FLORIDA BUILDING CODE, | | | PLUMBING. | | | | | | 9A) SHEET A6.0 CONSTRUCTION DETAILS, HVAC CURB. PLEASE | | | NOTE WITHOUT THE ROOF INSULATION THICKNESS THE HEIGHT | | | OF THE ROOF CURB IS A UNKNOWN. THE PLAN STATES 8 INCH | | | MINIMUM TO 1FOOT 2 INCHES TO THE TOP OF CURB. THE 2020 | | | FBC-B SECTION 1510.10 STATES THE CURB TO BE A MINIMUM | | | OF 8 INCHES ABOVE THE FINISHED ROOF HEIGHT. | | | | | | 9B) THE DETAIL ALSO STATES THIS CURB TYPE IS A | | | KNOCK-DOWN FLAT METAL CURB BY RTU SUPPLIER. PLEASE | | | PROVIDE THE ATTACHMENT OF THE ROOF CURB TO THE MWFRS | | | (MAIN WIND FORCE RESISTING SYSTEM) AND THE RTU UNIT TO | | | THE CURB. | | | | | | 2020 FBC-M- 301.15 WIND RESISTANCE. MECHANICAL | | | EQUIPMENT, APPLIANCES AND SUPPORTS THAT ARE EXPOSED TO | | | WIND SHALL BE DESIGNED AND INSTALLED TO RESIST THE WIND | | | PRESSURES DETERMINED IN ACCORDANCE WITH THE FLORIDA | | | BUILDING CODE, BUILDING. | | | FBC-B-1609.6.4.4.1 COMPONENTS AND CLADDING. WIND | | | PRESSURE FOR EACH COMPONENT OR CLADDING ELEMENT IS TO | | | BE DESIGNED FOR WIND PRESSURES COMPONENTS AND | | | ATTACHMENTS. | | | | | | LATERAL FORCE-RESISTING SYSTEM. FOR ALL ROOF TOP | | | EQUIPMENT, CURBS, FANS OR A/C STANDS, AND OR VENTS, | | | DETAILED ATTACHMENT TO THE ROOF FRAMING & DECK AS WELL | | | AS FROM THE CURB OR ROOF STAND TO THE EQUIPMENT ABOVE. | | | | | | 2020 FBC-B 1604.4 ANALYSIS. LOAD EFFECTS ON STRUCTURAL | | | MEMBERS AND THEIR CONNECTIONS SHALL BE DETERMINED BY | | | METHODS OF STRUCTURAL ANALYSIS THAT TAKE INTO ACCOUNT | | | EQUILIBRIUM, GENERAL STABILITY, GEOMETRIC COMPATIBILITY | | | AND BOTH SHORT- AND LONG-TERM MATERIAL PROPERTIES. | | | EVERY STRUCTURE SHALL BE DESIGNED TO RESIST THE | | | OVERTURNING EFFECTS CAUSED BY THE LATERAL FORCES | | | SPECIFIED IN THIS CHAPTER. SEE SECTION 1609 FOR WIND | | | LOADS. | | | | | | 9C) SHEET A6.0 DETAIL 18 SHOWS ROOF TOP EXHAUST FANS | | | AND CURBS. SEE COMMENT 9B REPEATED. | | | | | | 10) SHEET ADA.1: THE DETAILS FOR THE TOILET PAPER | | | DISPENSER DOES NOT PROVIDE THE DISTANCE FROM THE FRONT | | | OF THE WATER CLOSET TO THE CENTERLINE OF THE DISPENSER. | | | 2020 FBC-ACCESSIBILITY CODE, TOILET PAPER DISPENSERS. | | | 604.7. THE TOILET PAPER DISPENSER SHALL COMPLY WITH | | | 309.4 AND SHALL BE 7 INCHES MINIMUM TO 9 INCHES MAXIMUM | | | IN FRONT OF THE WATER CLOSET MEASURED TO THE CENTERLINE | | | OF THE DISPENSER. | | | | | | THE OUTLET OF THE DISPENSER SHALL BE 15 INCHES MINIMUM | | | AND 48 INCHES MAXIMUM ABOVE THE FINISH FLOOR AND SHALL | | | NOT BE LOCATED BEHIND THE GRAB BARS. | | | | | | | | | 11) SHEET ADA.2 INDICATES AA ENLARGED ACCESSIBLE | | | PARKING DETAIL AND ACCESS AISLE, DETAIL 16 OF ADA1.1. | | | THIS SHEET NOT INCLUDED IN THIS SET OF PLANS NOR THE | | | INDEX SHEET. | | | ACCESSIBLE PARKING SPACE / STALL PAINTING. | | | 2020 ACCESSIBILITY CODE SECTION 502.2 VEHICLE SPACES. | | | EACH PARKING SPACE MUST BE AT LEAST 12 FEET WIDE, SHALL | | | BE MARKED TO DEFINE THE WIDTH, AND SHALL HAVE AN | | | ADJACENT ACCESS AISLE COMPLYING WITH 502.3. | | | ADVISORY 502.3.3MARKING THE METHOD AND MARKING OF COLOR | | | OF MARKING ARE NOT SPECIFIED BY THESE REQUIREMENTS BUT | | | MAY BE ADDRESSED BY STATE OR LOCAL LAWS OR REGULATIONS. | | | WEST PALM MUNI-CODE ARTICLE XV PARKING DETAIL, 94-485 | | | ILLUSTRATES WITH MEASUREMENTS FOR DOUBLE STRIPE STALL | | | PAINTING. | | | | | | 502.4 ACCESS AISLE & PARKING SPACE SAME LEVEL/ 502.4, | | | FLOOR AND GROUND SURFACES. PARKING SPACES AND THE | | | ACCESS AISLES SERVING THEM SHALL COMPLY WITH 302. | | | ACCESS AISLES SHALL BE AT THE SAME LEVEL AS THE PARKING | | | SPACES THEY SERVE. | | | CHANGES IN LEVEL ARE NOT PERMITTED. EXCEPTION: SLOPES | | | NOT GREATER THAN 1:48 SHALL BE PERMITTED. GIVE | | | ELEVATION MARKERS TO SHOW COMPLIANCE. | | | | | | 12) THE SUBMITTED PRODUCT APPROVALS WERE NOT REVIEWED | | | THIS CYCLE SINCE THERE WERE NO STRUCTURAL DRAWINGS | | | WHICH WOULD HAVE HAD THE WIND DESIGN CRITERIA LISTED | | | AND THE ASSOCIATED PRESSURES. | | | | | | 12A) COMPONENTS & CLADDING. 2020 FBC-B 1609.1.2 | | | PROTECTION OF OPENINGS, 1609.6.4.4.1 COMPONENTS & | | | CLADDING. FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS, | | | ADMINISTRATIVE CODE 61G20-3.005, RULE 9N-3 NOV. 01/ | | | 2010 (31) SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION | | | SYSTEMS THAT WILL REQUIRE PRODUCT APPROVALS: | | | (31)(A) EXTERIOR DOORS, MULLIONS & ROOF HATCHES. | | | (B) WINDOWS & MULLIONS | | | (C) PANEL WALLS: STOREFRONTS, CURTAIN WALLS, WALL | | | LOUVERS, EFIS SYSTEMS, | | | (D) ROOFING PRODUCTS AND ASSEMBLIES, LIGHTWEIGHT | | | CONCRETE INSULATION, ROOF TOP VENTILATORS & FANS | | | (G) PRE-ENGINEERED A/C STANDS | | | | | | 12B) W. P. B. 107.3.4. PRODUCT APPROVALS. THOSE | | | PRODUCTS WHICH ARE REGULATED BY FLORIDA ADMINISTRATIVE | | | CODE RULE 61G20 SHALL BE REVIEWED AND APPROVED IN | | | WRITING (SHOP DRAWING STAMP OF APPROVAL) BY THE | | | DESIGNER OF RECORD PRIOR TO SUBMITTAL FOR | | | JURISDICTIONAL APPROVAL. | | | FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR | | | SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS, | | | SHOP DRAWINGS ETC. | | | | | | 12C) 107.3.4.2 DEFERRED SUBMITTALS. FOR THE PURPOSES OF | | | THIS SECTION, DEFERRED SUBMITTALS ARE DEFINED AS THOSE | | | PORTIONS OF THE DESIGN THAT ARE NOT SUBMITTED AT THE | | | TIME OF THE APPLICATION AND THAT ARE TO BE SUBMITTED TO | | | THE BUILDING OFFICIAL WITHIN A SPECIFIED PERIOD. | | | DEFERRAL OF ANY SUBMITTAL ITEMS SHALL HAVE THE PRIOR | | | APPROVAL OF THE BUILDING OFFICIAL. THE REGISTERED | | | DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE SHALL LIST | | | THE DEFERRED SUBMITTALS ON THE CONSTRUCTION DOCUMENTS | | | FOR REVIEW BY THE BUILDING OFFICIAL. | | | | | | DOCUMENTS FOR DEFERRED SUBMITTAL ITEMS SHALL BE | | | SUBMITTED TO THE REGISTERED DESIGN PROFESSIONAL IN | | | RESPONSIBLE CHARGE WHO SHALL REVIEW THEM AND FORWARD | | | THEM TO THE BUILDING OFFICIAL WITH A NOTATION | | | INDICATING THAT THE DEFERRED SUBMITTAL DOCUMENTS HAVE | | | BEEN REVIEWED AND FOUND TO BE IN GENERAL CONFORMANCE TO | | | THE DESIGN OF THE BUILDING. THE DEFERRED SUBMITTAL | | | ITEMS SHALL NOT BE INSTALLED UNTIL THE DEFERRED | | | SUBMITTAL DOCUMENTS HAVE BEEN APPROVED BY THE BUILDING | | | OFFICIAL. | | | | | | 12D) IDENTIFY GLAZING/ MULLIONS. PLEASE IDENTIFY ON THE | | | PRODUCT APPROVAL BEFORE SUBMITTING TO DESIGNER OF | | | RECORD AND BEFORE SUBMISSION TO THE BUILDING | | | DEPARTMENT. FOR ALL PRODUCTS WITH GLAZING, PLEASE | | | IDENTIFY THE OPENING WIDTH & HEIGHT, TYPE OF GLAZING, | | | MULLION SIZE, LENGTH IF UNREINFORCED OR REINFORCED | | | INFORMATION IF REQUIRED, ATTACHMENTS AND ASSOCIATE | | | PRESSURES FOR EACH OPENING SIZE. 2020 FBC-B 1405.13.1 | | | INSTALLATION. WINDOWS AND DOORS SHALL BE INSTALLED IN | | | ACCORDANCE WITH APPROVED MANUFACTURER?S INSTRUCTIONS. | | | FASTENER SIZE AND SPACING SHALL BE PROVIDED IN SUCH | | | INSTRUCTIONS AND SHALL BE CALCULATED BASED ON MAXIMUM | | | LOADS AND SPACING USED IN THE TESTS. | | | | | | 12E) EFIS SYSTEMS: PLEASE PROVIDE THE PRODUCT APPROVAL | | | FOR THE SYSTEM TO BE INSTALLED. PLEASE ALSO PROVIDE THE | | | MANUFACTURERS INSTALLATION BROCHURE PROVIDING | | | COMPLIANCE WITH 2014 FBC-B SECTIONS; | | | 1408.2 PERFORMANCE CHARACTERISTICS. | | | 1408.2 PERFORMANCE CHARACTERISTICS. | | | 1408.3 STRUCTURAL DESIGN. | | | 1408.4 WEATHER RESISTANCE. | | | 1408.4.1 EIFS WITH DRAINAGE. | | | 408.4.1.1 WATER-RESISTIVE BARRIER. | | | 1408.5 INSTALLATION. | | | | | | 12F) ROOFING: FOR ALL ROOFING PRODUCTS PLEASE IDENTIFY | | | ALL ROOFING SUB-SYSTEMS AND THEIR ASSOCIATED PRESSURES | | | FOR ROOF ZONE # 1. REVIEW THE PRODUCT APPROVAL | | | LIMITATIONS, IF ENHANCED FASTENING IS ALLOWED FOR ROOF | | | ZONES 2 & 3. FASTENER DENSITIES SHALL BE INCREASED FOR | | | BOTH INSULATION & THE BASE SHEET AS CALCULATED IN | | | COMPLIANCE WITH ROOFING APPLICATION STANDARDS RAS 117. | | | CALCULATION PREPARED, SIGNED AND SEALED BY A FLORIDA | | | REGISTERED PROFESSIONAL ENGINEER OR REGISTERED | | | ARCHITECT. 1609.6.4.4.1 COMPONENTS & CLADDING. | | | | | | 12G) 2020 FBC-B 1011.16 LADDERS. PERMANENT LADDERS | | | SHALL NOT SERVE AS A PART OF THE MEANS OF EGRESS FROM | | | OCCUPIED SPACES WITHIN A BUILDING. PERMANENT LADDERS | | | SHALL BE PERMITTED TO PROVIDE ACCESS TO THE FOLLOWING | | | AREAS: | | | 1.SPACES FREQUENTED ONLY BY PERSONNEL FOR MAINTENANCE, | | | REPAIR OR MONITORING OF EQUIPMENT. | | | 5.NONOCCUPIED ROOFS THAT ARE NOT REQUIRED TO HAVE | | | STAIRWAY ACCESS IN ACCORDANCE WITH SECTION | | | 1011.12.1. | | | 6.LADDERS SHALL BE CONSTRUCTED IN ACCORDANCE WITH | | | SECTION 306.5 OF THE FLORIDA BUILDING CODE, | | | MECHANICAL. | | | LADDERS SHALL COMPLY WITH THE FOLLOWING MINIMUM DESIGN | | | CRITERIA: | | | 1. THE SIDE RAILING SHALL EXTEND ABOVE THE PARAPET OR | | | ROOF EDGE NOT LESS THAN 30 INCHES (762 MM). | | | 2. LADDERS SHALL HAVE RUNG SPACING NOT TO EXCEED 14 | | | INCHES (356 MM) ON CENTER. | | | 3. LADDERS SHALL HAVE A TOE SPACING NOT LESS THAN | | | 6-INCHES (152 MM) DEEP. | | | 4. THERE SHALL BE A MINIMUM OF 18 INCHES (457 MM) | | | BETWEEN RAILS. | | | 5. RUNGS SHALL HAVE A MINIMUM 0.75-INCH (19 MM) | | | DIAMETER AND BE CAPABLE OF WITHSTANDING A 300-POUND | | | (136.1 KG) LOAD. | | | 6. LADDERS OVER 30 FEET (9144 MM) IN HEIGHT SHALL BE | | | PROVIDED WITH OFFSET SECTIONS AND LANDINGS CAPABLE OF | | | WITHSTANDING 100 POUNDS PER SQUARE FOOT (488.2 KG/M2). | | | 7. LADDERS SHALL BE PROTECTED AGAINST CORROSION BY | | | APPROVED MEANS. CATWALKS INSTALLED TO PROVIDE THE | | | REQUIRED ACCESS SHALL BE NOT LESS THAN 24-INCHES (610 | | | MM) WIDE AND SHALL HAVE RAILINGS AS REQUIRED FOR | | | SERVICE PLATFORMS. | | | | | | 12H) ROOF TOP HATCHES/ ROOF ACCESS/ 2020 FBC-B | | | 1011.12.2. IN BUILDINGS THAT DO NOT HAVE AN OCCUPIED | | | ROOF SHALL BE PERMITTED TO BE A ROOF HATCH OR TRAP DOOR | | | NOT LESS THAN 16 SQUARE FEET IN AREA AND HAVING A | | | MINIMUM DIMENSION OF 2 FEET. | | | | | | 13) IMPACT FEES - DIGITAL SUBMITTALS: PLANS WILL BE | | | REVIEWED BY THE PBC IMPACT FEE OFFICE DIGITALLY VIA | | | PROJECT DOX UPON NOTIFICATION BY THIS OFFICE. | | | NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST FINAL | | | FORM. YOU MAY COORDINATE WITH THE IMPACT FEE OFFICE AT | | | (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL IMPACT | | | FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME THE | | | FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM CAN | | | BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINISTRAT | | | ION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF UPON | | | APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE RECEIPT TO | | | YOUR PROJECT OR EMAIL IT TO [email protected] . | | | PALM BEACH COUNTY IMPACT FEE OFFICE IS LOCATED AT 2300 | | | N. JOG RD. ROOM?S 2W01-2W14 WEST PALM BEACH, FL. | | | | | | 14) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW | | | COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | | THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR | | | PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | PLEASE NOTE WITH THE LACK OF INFORMATION FOR THIS | | | REVIEW, SUBSEQUENT REMARKS MAYBE MADE IN THE NEXT | | | REVIEW CYCLE. | | | | | | PLEASE NOTE WE ARE WORKING FROM HOME BECAUSE OF COVID | | | 19 | | | IF YOU WOULD LIKE TO CONTACT ME, MY CELL NUMBER IS | | | 561-718-9724. | | | WORKING HOURS ARE MON.- WED. 8:00 AM- NOON. PART-TIME/ | | | RETIRED. | | | | | | JAMES A. WITMER BN, PX, SFP, CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT | | | 401 CLEMATIS ST. WEST PALM BEACH. FL 33402 | | | TEL: 561-805-6717 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | DEVELOPMENT SERVICES HOME PAGE | | | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP | | | | | | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS | | | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS | | | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO | | | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE | | | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. | | | | | | MEMBER OF BOAF: BUILDING OFFICIALS ASSOCIATION OF | | | FLORIDA SAVING LIVES AND PROPERTY SINCE 1953. | | | | | | | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2021-06-24 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2021-06-24 |
Time |
08:04 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2021-06-24 |
Time |
07:38 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2021-05-27 |
|
|
Cont ID |
|
| Sent By |
equinone |
Date |
2021-05-27 |
Time |
16:44 |
Rev Time |
0.00 |
| Received By |
equinone |
Date |
2021-05-27 |
Time |
16:27 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2021-03-17 |
|
|
Cont ID |
|
| Sent By |
equinone |
Date |
2021-03-17 |
Time |
15:13 |
Rev Time |
0.00 |
| Received By |
equinone |
Date |
2021-03-17 |
Time |
14:01 |
Sent To |
|
|
| Notes |
| 2021-03-17 15:13:57 | CODES IN EFFECT | | | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2020 7TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2020 | | | 7TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 | | | 7TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2020 | | | 7TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2020 7TH EDITION | | | NEC = NFPA 70 2017 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | FAC = FLORIDA ADMINISTRATIVE CODE | | | | | | REVIEW STATUS: FAILED. PLEASE SEE COMMENTS BELOW: | | | | | | 1) SHEET E7.0 (COMPLIANCE REPORT): COMPLIANCE REPORT | | | AND CALCULATIONS SHOULD BE DONE ACCORDING TO THE FBC | | | ENERGY CONSERVATION 2020 7TH EDITION | | | | | | END OF COMMENTS. | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | IF THE RESUBMITTAL IS NOT PREPARED BY A DESIGN | | | PROFESSIONAL (ARCHITECT OR ENGINEER), AND THE PAGES ARE | | | 11X17 OR SMALLER, YOU MAY RESUBMIT, ALONG WITH A | | | COMPLETED RESUBMITTAL FORM, VIA EMAIL TO | | | [email protected]. THE EMAIL SHOULD INCLUDE THE PERMIT | | | NUMBER AND "RESUBMITTAL" IN THE SUBJECT LINE. THE | | | RESUBMITTAL FORM CAN BE FOUND AT THIS WEBSITE: | | | HTTPS://WWW.WPB.ORG/GOVERNMENT/DEVELOPMENT-SERVICES/FOR | | | MS | | | ENRIQUE QUINONEZ P.E. | | | ELECTRICAL PLANS EXAMINER | | | DEVELOPMENT SERVICES | | | CITY OF WEST PAM BEACH | | | 401 CLEMATIS STREET, 1ST FLOOR | | | WEST PALM BEACH, FL 33401 | | | | | | FEEL FREE TO CONTACT ME IF YOU WISH TO DISCUSS, | | | 561-805-6746. | | | |
|
|
| Review Stop |
E-LOWVOLT |
ELECTRICAL LOW VOLTAGE |
| Rev No |
1 |
Status |
P |
Date |
2022-02-28 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2022-02-28 |
Time |
13:54 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2022-02-28 |
Time |
13:54 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
2 |
Status |
P |
Date |
2021-06-01 |
|
|
Cont ID |
|
| Sent By |
rrossano |
Date |
2021-06-01 |
Time |
|
Rev Time |
0.00 |
| Received By |
rrossano |
Date |
2021-06-01 |
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
F |
Date |
2021-03-31 |
|
|
Cont ID |
|
| Sent By |
rrossano |
Date |
2021-03-31 |
Time |
|
Rev Time |
|
| Received By |
rrossano |
Date |
2021-03-31 |
Time |
|
Sent To |
|
|
| Notes |
| 2021-03-31 08:58:54 | CURRENTLY UNDER REVIEW AS ENGINEERING SUBMITTAL | | | E21020005. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2021-03-02 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2021-03-02 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2021-03-02 |
Time |
12:41 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
3 |
Status |
P |
Date |
2021-06-29 |
|
|
Cont ID |
|
| Sent By |
jesmith |
Date |
2021-06-24 |
Time |
16:05 |
Rev Time |
0.00 |
| Received By |
jesmith |
Date |
2021-06-24 |
Time |
15:49 |
Sent To |
|
|
| Notes |
| 2021-06-29 15:59:36 | 21010992 1225 PALM BEACH LAKES BLVD | | | | | | | | | GAS COMMENTS: APPROVED | | | | | | ALL WORK PER STATE AND CITY CODES SUBJECT TO FIELD | | | INSPECTOR'S APPROVAL | | | | | | BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE | | | COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN | | | PROFESSIONAL, CONTRACTORS OR THEIR REPRESENTATIVES FROM | | | THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL, STATE AND | | | NATIONAL CODES AND STANDARDS IN EFFECT AT THE TIME OF | | | PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK OF EVERY | | | ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM | | | REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES | | | / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO | | | AVOID VOIDING OF THE PERMIT. | | | | | | COMBUSTION AIR CALCULATIONS PROVIDED ON M-2.0 | | | | | | CITY OF WEST PALM BEACH GAS PIPING AFFIDAVIT OR | | | MANOMETER TEST DOCUMENT REQUIRED AT JOBSITE FOR FINAL | | | GAS INSPECTION. CALL 561-805-6692 FOR FURTHER | | | INFORMATION | | | | | | THE INSTALLATION MANUALS FOR ALL GAS | | | APPLIANCES/EQUIPMENT SHALL BE AT JOB SITE FOR FINAL GAS | | | INSPECTION | | | | | | A GAS SUB PERMIT IS REQUIRED | | 2021-06-29 10:34:18 | HOLD FOR REVISED DRAWINGS FROM ENGINEER | | 2021-06-24 16:04:58 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2020 7TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1 | | | WPB CCCM=WEST PALM BEACH CROSS-CONNECTION CONTROL | | | MANUAL REVISED 2017 | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 | | | 7TH EDITION | | | FBC ACC = FLORIDA ACCESSIBILITY CODE 2020 7TH EDITION | | | FBC PL = FLORIDA PLUMBING CODE 2020 7TH EDITION | | | FBC FG = FLORIDA FUEL GAS CODE 2020 7TH EDITION | | | NFPA 54 = NATIONAL FUEL GAS CODE | | | NFPA 58 = LIQUIFIED PETROLEUM GAS CODE | | | NFPA 96 = STANDARD FOR VENTILATION CONTROL AND FIRE | | | PROTECTION OF COMMERCIAL COOKING OPERATIONS 2017 | | | FAC= FLORIDA ADMINISTRATIVE CODE | | | FS = FLORIDA STATUTES | | | | | | 21010992 1225 PALM BEACH LAKES BLVD | | | | | | 3RD REVIEW | | | | | | GAS COMMENTS: DENIED | | | | | | 1. PREVIOUS REQUEST: PER WPB FBC 107.2.1, SUBMIT | | | CALCULATIONS FOR COMBUSTION AIR PER FBC FG 304.1. THIS | | | IS NOT TO BE CONFUSED WITH MAKE-UP AIR. RESPONSE FROM | | | ENGINEER; COMBUSTION AIR TO BE PROVIDED VIA DIRECT | | | VENT. KEYNOTE 14 (THE NOTE IS 13) ON WASTE AND VENT | | | PLAN P2.0 HAS BEEN REVISED TO REFLECT THIS. THIS | | | ADDRESSES COMBUSTION AIR FOR THE TANKLESS WATER HEATERS | | | BUT DOES NOT ADDRESS THE APPLIANCES ON THE COOKING | | | LINE. PER WPB FBC 107.2.1, PROVIDE CALCULATIONS FOR | | | COMBUSTION AIR PER FBC FG 304.1. THIS IS NOT TO BE | | | CONFUSED WITH MAKE-UP AIR. | | | | | | RESPONSE: PER FBC FG 304.9, THE 455,000 BTU/H COOKING | | | LINE REQUIRES 159.25 CFM OF MECHANICALLY SUPPLIED | | | COMBUSTION AIR. THIS REQUIREMENT IS MET BY THE KITCHEN | | | RTU PROVIDING 770 CFM OF OUTDOOR AIR TO THE SPACE. | | | | | | NEW COMMENT: PER WPB FBC 107.2.1, PROVIDE THIS | | | INFORMATION ON THE PLANS. | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. ALL PLANS TO BE SIGNED | | | AND SEALED BY THE DESIGNER AS REQUIRED BY FAC AND FS. | | | | | | JERALD SMITH | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | EMAIL [email protected] | | | MOBILE 561-243-0882 | | | PLEASE NOTE THAT I TYPICALLY WORK ON TUESDAYS AND | | | THURSDAYS. | | | | | | 21010992 1225 PALM BEACH LAKES BLVD | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
F |
Date |
2021-05-25 |
|
|
Cont ID |
|
| Sent By |
jesmith |
Date |
2021-05-25 |
Time |
16:01 |
Rev Time |
0.00 |
| Received By |
jesmith |
Date |
2021-05-25 |
Time |
09:22 |
Sent To |
|
|
| Notes |
| 2021-05-25 15:59:31 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2020 7TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1 | | | WPB CCCM=WEST PALM BEACH CROSS-CONNECTION CONTROL | | | MANUAL REVISED 2017 | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 | | | 7TH EDITION | | | FBC ACC = FLORIDA ACCESSIBILITY CODE 2020 7TH EDITION | | | FBC PL = FLORIDA PLUMBING CODE 2020 7TH EDITION | | | FBC FG = FLORIDA FUEL GAS CODE 2020 7TH EDITION | | | NFPA 54 = NATIONAL FUEL GAS CODE | | | NFPA 58 = LIQUIFIED PETROLEUM GAS CODE | | | NFPA 96 = STANDARD FOR VENTILATION CONTROL AND FIRE | | | PROTECTION OF COMMERCIAL COOKING OPERATIONS 2017 | | | FAC= FLORIDA ADMINISTRATIVE CODE | | | FS = FLORIDA STATUTES | | | | | | 21010992 1225 PALM BEACH LAKES BLVD | | | | | | 2ND REVIEW | | | | | | GAS COMMENTS: DENIED | | | | | | SECOND REQUEST: PER WPB FBC 107.2.1, SUBMIT | | | CALCULATIONS FOR COMBUSTION AIR PER FBC FG 304.1. THIS | | | IS NOT TO BE CONFUSED WITH MAKE-UP AIR. | | | RESPONSE FROM ENGINEER; COMBUSTION AIR TO BE PROVIDED | | | VIA DIRECT VENT. KEYNOTE 14 (THE NOTE IS ACTUALLY 13) | | | ON WASTE AND VENT PLAN P2.0 HAS BEEN REVISED TO REFLECT | | | THIS. | | | THIS ADDRESSES COMBUSTION AIR FOR THE TANKLESS WATER | | | HEATERS BUT DOES NOT ADDRESS THE APPLIANCES ON THE | | | COOKING LINE. PER WPB FBC 107.2.1, PROVIDE CALCULATIONS | | | FOR COMBUSTION AIR PER FBC FG 304.1. THIS IS NOT TO BE | | | CONFUSED WITH MAKE-UP AIR. | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. ALL PLANS TO BE SIGNED | | | AND SEALED BY THE DESIGNER AS REQUIRED BY FAC AND FS. | | | | | | JERALD SMITH | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | EMAIL [email protected] | | | MOBILE 561-243-0882 | | | PLEASE NOTE THAT I TYPICALLY WORK ON TUESDAYS AND | | | THURSDAYS. | | | | | | 21010992 1225 PALM BEACH LAKES BLVD |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2021-03-30 |
|
|
Cont ID |
|
| Sent By |
jesmith |
Date |
2021-03-30 |
Time |
14:48 |
Rev Time |
0.00 |
| Received By |
jesmith |
Date |
2021-03-25 |
Time |
09:04 |
Sent To |
|
|
| Notes |
| 2021-03-30 14:46:56 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2020 7TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1 | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 | | | 7TH EDITION | | | FBC PL = FLORIDA PLUMBING CODE 2020 7TH EDITION | | | FBC FG = FLORIDA FUEL GAS CODE 2020 7TH EDITION | | | NFPA 54 = NATIONAL FUEL GAS CODE | | | NFPA 58 = LIQUIFIED PETROLEUM GAS CODE | | | NFPA 96 = STANDARD FOR VENTILATION CONTROLAND FIRE | | | PROTECTION OF COMMERCIAL COOKING OPERATIONS 2017 | | | FAC= FLORIDA ADMINISTRATIVE CODE | | | FS = FLORIDA STATUTES | | | | | | 21010992 1225 PALM BEACH LAKES BLVD | | | | | | 1ST REVIEW | | | GAS COMMENTS: DENIED | | | | | | 1.PLEASE NOTE THAT P3.0, NOTE 18 INDICATES A SINGLE | | | EXHAUST FOR THE WATER HEATER REFERENCING P6.0, | | | DETAIL.THIS NEEDS TO BE ADDRESSED AND CLARIFIED PER WPB | | | FBC 107.2.1. | | | | | | 2.REGARDING GAS SUPPLIED KITCHEN EQUIPMENT: KITCHEN | | | EQUIPMENT SCHEDULE ON PLAN SHEET A2.1, GAS EQUIPMENT | | | SCHEDULE AND GAS RISER DIAGRAM ON PLAN SHEET P5.0 DO | | | NOT MATCH. A2.1 C COOKING EQUIPMENT SCHEDULE INDICATES | | | ONE EACH (1) C-018, TWO EACH (2) C-025 AND ONE EACH (1) | | | C-130. PER WPB FBC RECONCILE THIS SCHEDULE WITH THE GAS | | | DEMAND SCHEDULE ON P5.0. ADDITIONALLY, RECONCILE RISER | | | DIAGRAM AND GAS DEMAND SCHEDULE. | | | | | | 3.PROVISO: SEE DETAIL 2. PER WPB FBC 107.2.1, THE | | | MANUFACTURER'S SPECIFICATION/INSTALLATION MANUAL FOR | | | WATER HEATER VENT UBBINK OR HEAT FAB SAF-T VENT SC | | | SHALL BE SUBMITTED, APPROVED, IN PLACE AND PLAN SHALL | | | BE REVISED TO REFLECT FOR FINAL INSPECTION. | | | | | | 4.PLEASE SEE PLUMBING COMMENTS. PLANS SHOW BOTH | | | TANKLESS WATER HEATERS AND A TANK TYPE WATER HEATER. | | | PER WPB FBC 107.2.1, THIS NEEDS TO BE CLARIFIED AND | | | RECONCILED. | | | | | | 5. PER WPB FBC 107.2.1, SHOW THE TYPE OF PIPE MATERIAL | | | BEING INSTALLED, ALL PIPE SIZES, AND THE CORRESPONDING | | | EHD NUMBER OF THE CORRUGATED STAINLESS STEEL TUBING (IF | | | APPLICABLE) FOR EACH PIPE SIZE. | | | | | | 6.TYPE OF GAS APPEARS TO BE NATURAL. PER WPB FBC | | | 107.2.1, INDICATE ON GAS DEMAND SCHEDULE. | | | | | | 7. PER WPB FBC 107.2.1, PROVIDE TABLE(S) FOR SIZING OF | | | PIPING. REFER TO FBC FG 401.8, 402.2, AND TABLES 402.4 | | | (1) THRU 402.4. | | | | | | 8. PER WPB FBC 107.2.1, SUBMIT CALCULATIONS FOR | | | COMBUSTION AIR PER FBC FG 304.1. THIS IS NOT TO BE | | | CONFUSED WITH MAKE UP AIR. | | | | | | 9. PER WPB FBC 107.2.1, SUBMIT A DETAIL SHOWING THE | | | TYPE, LOCATION, SIZE, TERMINATION POINT, HEIGHT ABOVE | | | THE ROOF AND ANCHORING DETAILS OF THE GAS VENT(S) PER | | | FBC FG 502 THRU 505. | | | | | | 10. PER WPB FBC 107.2.1, SUBMIT MANUFACTURER'S | | | SPECIFICATION SHEETS / INSTALLATION MANUAL FOR ALL GAS | | | EQUIPMENT TO VERIFY COMPLIANCE WITH STANDARDS NFPA 54, | | | NFPA 58, AND FBC FG 402.2, AND 301.3. GAS APPLIANCES | | | SHALL BE LISTED AND LABELED. THE INSTALLATION MANUALS | | | FOR ALL GAS APPLIANCES / EQUIPMENT SHALL BE ONSITE AT | | | THE TIME OF INSPECTION PER FBC FG 305.1. | | | | | | 11.EMERGENCY HOOD SHUT DOWN SHUT OFF VALVE SHALL BE | | | BELOW THE CEILING. THE MANUAL SHUTOFF VALVE SHALL BE | | | UPSTREAM. UNION TO BE DOWN STREAM OF MANUAL VALVE. | | | SECS. 10.4, 10.5 OF NFPA 96-08. PER WPB FBC 107.2.1, | | | IDENTIFY ON RISER DIAGRAM AND PROVIDE A DETAIL. | | | | | | | | | END OF COMMENTS. | | | A COMPREHENSIVE REVIEW COULD NOT BE ACCOMPLISHED AT | | | THIS TIME. PLEASE RESUBMIT CLEARLY LEGIBLE PLANS AND A | | | RESPONSE NARRATIVE ADDRESSING THE GAS/PLUMBING COMMENTS | | | FROM THE PRIOR REVIEW. | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS.ALL PLANS TO BE SIGNED | | | AND SEALED BY THE DESIGNER AS REQUIRED BY FAC AND FS. | | | | | | | | | | | | JERALD SMITH | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | EMAIL [email protected] | | | MOBILE 561-246-0882 | | | PLEASE NOTE THAT I TYPICALLY WORK ON TUESDAYS AND | | | THURSDAYS | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2021-07-09 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2021-07-09 |
Time |
16:11 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2021-06-22 |
Time |
11:49 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2021-06-09 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2021-06-09 |
Time |
14:12 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2021-05-19 |
Time |
16:08 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2021-05-14 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-05-14 |
Time |
14:55 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-02-24 |
Time |
13:36 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
P |
Date |
2021-07-16 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2021-07-16 |
Time |
08:29 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2021-07-01 |
Time |
11:28 |
Sent To |
|
|
| Notes |
| 2021-07-16 08:29:18 | RECEIPT MU-2021-34652 - $0.00 DUE | | 2021-07-01 11:28:51 | 7/1/21 EMAILED IMPACT OFFICE FOR REVIEW. LEM |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2021-03-01 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2021-03-01 |
Time |
12:44 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2021-03-01 |
Time |
10:00 |
Sent To |
|
|
| Notes |
| 2021-03-01 12:44:20 | IMPACT FEES - DIGITAL SUBMITTALS: PLANS WILL BE | | | REVIEWED BY THE PBC IMPACT FEE OFFICE DIGITALLY VIA | | | PROJECT DOX UPON NOTIFICATION BY THIS OFFICE. | | | NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST FINAL | | | FORM. YOU MAY COORDINATE WITH THE IMPACT FEE OFFICE AT | | | (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL IMPACT | | | FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME THE | | | FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM CAN | | | BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINISTRAT | | | ION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF UPON | | | APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE RECEIPT TO | | | YOUR PROJECT OR EMAIL IT TO [email protected] . |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2021-06-29 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-06-29 |
Time |
16:18 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-06-29 |
Time |
16:18 |
Sent To |
|
|
| Notes |
| 2021-06-29 16:21:50 | THE MECHANICAL APPROVAL IS FOR THE MECHANICAL SYSTEM | | | ONLY. THE HOODS AND REFRIGERATION ON THESE DRAWINGS | | | HAVE NOT BEEN REVIEWED AS THEY WILL REQUIRE SEPARATE | | | PERMIT SUBMITTALS AND REVIEWS. | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2021-06-23 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-06-23 |
Time |
08:37 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-06-23 |
Time |
08:37 |
Sent To |
|
|
| Notes |
| 2021-06-23 08:38:45 | THE MECHANICAL APPROVAL IS FOR THE MECHANICAL SYSTEM | | | ONLY. THE HOODS AND REFRIGERATION ON THESE DRAWINGS | | | HAVE NOT BEEN REVIEWED AS THEY WILL REQUIRE SEPARATE | | | PERMIT SUBMITTALS AND REVIEWS. | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2021-05-28 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-05-28 |
Time |
15:14 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-05-28 |
Time |
15:13 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2021-03-29 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-03-29 |
Time |
11:42 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-03-29 |
Time |
08:25 |
Sent To |
|
|
| Notes |
| 2021-03-29 11:42:43 | 1ST REVIEW FBC-2020 MECHANICAL | | | PERMIT-21010992 | | | | | | CODES IN EFFECT: | | | | | | FBC B- FLORIDA BUILDING CODE | | | FBC M- FLORIDA MECHANICAL CODE | | | FBC EC- FLORIDA ENERGY CONSERVATION | | | FBC FG- FLORIDA FUEL GAS | | | FBC EX- FLORIDA EXISTING BUILDING CODE | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) SHEET M-1.0: NOTE 10 INDICATES SMOKE DETECTORS ARE | | | TO BE MOUNTED IN THE RETURN AIR DUCT. PLEASE CHANGE | | | THIS STATEMENT AS IT DOES NOT MEET THE MECHANICAL CODE | | | SECTION FBC M 606.2.1. THE SMOKE DETECTOR SHALL BE | | | INSTALLED ON THE SUPPLY SIDE OF THE AIR HANDLING | | | SYSTEMS. | | | | | | 2) PLEASE PROVIDE A NOTE ON THE DRAWING THAT THE HOODS | | | AND ALL RELATED SYSTEMS MUST BE SUBMITTED AS A SEPARATE | | | SUBMITTAL AND MUST HAVE ITS OWN REVIEW AND PERMIT. | | | | | | 3) PLEASE REMOVE ALL DRAWINGS ASSOCIATED WITH THE HOOD | | | FROM THIS SUBMITTAL AS IT WILL BE A STAND ALONE PERMIT | | | AND REVIEW. AND WILL NOT BE REVIEWED IN THIS SUBMITTAL. | | | | | | 4) PLEAS PROVIDE A NOTE ON THE DRAWINGS THAT THE | | | REFRIGERATION EQUIPMENT MUST BE SUBMITTED AS A SEPARATE | | | SUBMITTAL AND MUST HAVE ITS OWN REVIEW AND PERMIT. | | | | | | 5) PLEASE PROVIDE ENERGY CALCULATIONS FOR THIS PROJECT. | | | FBC EC C402.1 | | | | | | 6) PLEASE PROVIDE MECHANICAL EQUIPMENT SIZING | | | CALCULATIONS. FBC EC C403.2.1 | | | | | | 7) SHEET M2.0: IT APPEARS THAT THERE IS A RETURN VERY | | | CLOSE TO THE HOOD IN THE KITCHEN AREA. PLEASE SHOW THAT | | | THIS RETURN MEETS THE 10 FT. MINIMUM AWAY FROM THE | | | COOKING APPLIANCES. FBC M 601.5 EXCEPTION (1). | | | | | | 8) SHEET M2.1: PLEASE SHOW THE ROOF ACCESS ON THE | | | MECHANICAL ROOF DRAWING. FBC M 306.5 | | | | | | 9) SHEET M2.1: PLEASE SHOW THAT THE MECHANICAL ON THE | | | ROOF MEETS THE 10 FEET FROM THE ROOFS EDGE OR THE | | | REQUIRED GUARDS ARE USED. FBC M 307.11 | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE OLD | | | SHEETS FROM THE PLAN SETS, BIND THEM TOGETHER | | | SEPARATELY AND MARK VOID OR OLD ON THEM. PLEASE RETAIN | | | THEM FOR REFERENCE WITH THE NEW SUBMITTED PLANS. THIS | | | PROCESS WILL ALSO APPLY TO ANY DOCUMENTS SUCH AS | | | PRODUCT APPROVALS OR CALCULATIONS BEING REPLACED OR | | | UPDATED. | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2021-06-29 |
|
|
Cont ID |
|
| Sent By |
jesmith |
Date |
2021-06-24 |
Time |
15:48 |
Rev Time |
0.00 |
| Received By |
jesmith |
Date |
2021-06-24 |
Time |
15:46 |
Sent To |
|
|
| Notes |
| 2021-06-29 15:55:23 | 21010992 1225 PALM BEACH LAKES BLVD | | | | | | | | | PLUMBING COMMENTS: APPROVED | | | | | | ALL WORK PER STATE AND CITY CODES SUBJECT TO FIELD | | | INSPECTOR'S APPROVAL | | | | | | BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE | | | COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN | | | PROFESSIONAL, CONTRACTORS OR THEIR REPRESENTATIVES FROM | | | THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL, STATE AND | | | NATIONAL CODES AND STANDARDS IN EFFECT AT THE TIME OF | | | PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK OF EVERY | | | ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM | | | REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES | | | / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO | | | AVOID VOIDING OF THE PERMIT. | | | | | | A SEPARATE SUB PERMIT IS REQUIRED FOR THE GREASE | | | INTERCEPTOR | | | | | | A SEPARATE SUB PERMIT IS REQUIRED FOR THE BACKFLOW | | | PREVENTER | | | | | | JERALD SMITH | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | EMAIL [email protected] | | | MOBILE 561-243-0882 | | | PLEASE NOTE THAT I TYPICALLY WORK ON TUESDAYS AND | | | THURSDAYS. | | | | | 2021-06-29 10:35:19 | HOLD FOR REVISED DRAWINGS FROM ENGINEER | | 2021-06-24 15:47:13 | PLUMBING | | | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2020 7TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1 | | | WPB CCCM=WEST PALM BEACH CROSS-CONNECTION CONTROL | | | MANUAL REVISED 2017 | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 | | | 7TH EDITION | | | FBC ACC = FLORIDA ACCESSIBILITY CODE 2020 7TH EDITION | | | FBC PL = FLORIDA PLUMBING CODE 2020 7TH EDITION | | | FBC FG = FLORIDA FUEL GAS CODE 2020 7TH EDITION | | | NFPA 54 = NATIONAL FUEL GAS CODE | | | NFPA 58 = LIQUIFIED PETROLEUM GAS CODE | | | NFPA 96 = STANDARD FOR VENTILATION CONTROL AND FIRE | | | PROTECTION OF COMMERCIAL COOKING OPERATIONS 2017 | | | FAC= FLORIDA ADMINISTRATIVE CODE | | | FS = FLORIDA STATUTES | | | | | | 21010992 1225 PALM BEACH LAKES BLVD | | | | | | 3RD REVIEW | | | | | | PLUMBING COMMENTS: DENIED | | | | | | 1.PROVIDED GREASE INTERCEPTOR DETAIL GS-7 ON P-8 DOES | | | NOT CORRESPOND WITH THE WPB PUBLIC WORKS DEPT. STANDARD | | | DETAIL GS-7 (CONCRETE) FOR GREASE INTERCEPTOR IN MY | | | FILES. I WILL FORWARD PDF GS-7 GREASE INTERCEPTOR | | | REDLINED FOR YOUR USE IN PREPARING A REVISED SUBMITTAL | | | TO [email protected], [email protected] AND | | | [email protected]. I APOLOGIZE IF THERE WAS A | | | MISCOMMUNICATION ON MY PART REGARDING THE STANDARD | | | DETAIL. | | | IT IS NOTED THE GREASE TRAP CALCULATIONS HAVE BEEN | | | INCLUDED ON P8.0. | | | | | | 2.ADDITIONALLY, PER WPB PUBLIC WORKS DEPT. CONCRETE | | | GRAVITY SEWER SYSTEM-GREASE INTERCEPTOR STANDARD DETAIL | | | GS-7-NOTE 4, A CONCRETE GREASE INTERCEPTOR SHALL HAVE A | | | MINIMUM 750 GALLON/ MAXIMUM 1250 GALLON CAPACITY. WHEN | | | REQUIRED EFFECTIVE CAPACITY IS GREATER THAN 1250 | | | GALLONS, PROVIDE A MULTI-CHAMBERED INTERCEPTOR OR | | | MULTIPLE INTERCEPTORS INSTALLED IN SERIES. P8.0 AND | | | P1.0 CALL FOR A 1500 GALLON INTERCEPTOR. | | | | | | | | | | | | 3.REGARDING SUBMITTED CIVIL DRAWINGS; NOTE C-10 UTILITY | | | PLAN INDICATES 6 INCH GREASY WASTE INTO AND OUT OF THE | | | GREASE INTERCEPTOR AND A 6 INCH BUILDING SEWER; P1.0AND | | | P5.0 INDICATE ALL 4 INCH SIZING. PER WPB FBC 107.2.1, | | | RECONCILE CIVIL AND PLUMBING PLANS. | | | | | | 4. RESPONSE: TRAP PRIMER SHALL BE SPECIFIED AND | | | DETAILED. THE TRAP PRIMER IS SPECIFIED ON P1.0 WITH THE | | | FLOOR DRAIN FD-1. SEE DETAIL 1, SHEET P7.0. | | | P1.0 IS COMPLIANT. SHEET P7.0 IS NOT IN THE NEW | | | SUBMITTALS. | | | | | | 5. RESPONSE: CONDENSATE DRYWELL IS INDICATED ON P2.0 | | | KEYNOTE 15 AND DETAILED ON P7.0 DETAIL #2. | | | P1.0 IS COMPLIANT. SHEET P7.0 IS NOT IN THE NEW | | | SUBMITTALS. | | | | | | 6.RESPONSE: FLOOR SINK IS IDENTIFIED ON P2.0 NEXT TO | | | S-4 AND P4.0 IN THE SAME LOCATION. | | | NOTED ON P2.0 AND P4.0; ISSUE IS ON P5.0 WHICH HAS S-4 | | | AND S-2 IN OPPOSITE LOCATIONS FROM THAT ON P2.0 AND | | | P4.0. PER WPB FBC 107.2.1, CORRECTLY IDENTIFY ON P5.0, | | | S-2 AND S-4. | | | | | | 8.REGARDING RESPONSE: 6? GREASE WASTE REFERENCE SHALL | | | BE REVISED TO 4? | | | SECOND REQUEST: PER WPB FBC 107.2.1, ON P5.0, SHOW | | | SIZE(S) OF SANITARY AND GREASY WASTE BUILDING DRAINS. | | | | | | | | | 9. RESPONSE: HEAT TRACE PIPING IS SPECIFIED ON P2.0, | | | KEYNOTE #7. THE DETAIL IS ON P7.0, DETAIL #3. | | | P2.0 SPECIFICATION IS NOTED. SHEET P7.0 IS NOT IN THE | | | NEW SUBMITTALS; NOTHING NOTED REGARDING INSULATION. | | | | | | | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. ALL PLANS TO BE SIGNED | | | AND SEALED BY THE DESIGNER AS REQUIRED BY FAC AND FS. | | | | | | JERALD SMITH | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | EMAIL [email protected] | | | MOBILE 561-243-0882 | | | PLEASE NOTE THAT I TYPICALLY WORK ON TUESDAYS AND | | | THURSDAYS. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2021-05-25 |
|
|
Cont ID |
|
| Sent By |
jesmith |
Date |
2021-05-25 |
Time |
15:06 |
Rev Time |
0.00 |
| Received By |
jesmith |
Date |
2021-05-25 |
Time |
09:22 |
Sent To |
|
|
| Notes |
| 2021-05-25 15:06:51 | PLUMBING | | | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2020 7TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1 | | | WPB CCCM=WEST PALM BEACH CROSS-CONNECTION CONTROL | | | MANUAL REVISED 2017 | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 | | | 7TH EDITION | | | FBC ACC = FLORIDA ACCESSIBILITY CODE 2020 7TH EDITION | | | FBC PL = FLORIDA PLUMBING CODE 2020 7TH EDITION | | | FBC FG = FLORIDA FUEL GAS CODE 2020 7TH EDITION | | | NFPA 54 = NATIONAL FUEL GAS CODE | | | NFPA 58 = LIQUIFIED PETROLEUM GAS CODE | | | NFPA 96 = STANDARD FOR VENTILATION CONTROLAND FIRE | | | PROTECTION OF COMMERCIAL COOKING OPERATIONS 2017 | | | FAC= FLORIDA ADMINISTRATIVE CODE | | | FS = FLORIDA STATUTES | | | | | | 21010992 1225 PALM BEACH LAKES BLVD | | | | | | 2ND REVIEW | | | GENERAL NOTES | | | A SEPARATE PLUMBING SUB-PERMIT IS REQUIRED FOR THE | | | GREASE INTERCEPTOR. A PLAN WITH DETAIL OF THE GREASE | | | INTERCEPTOR TO BE INSTALLED AND REQUIRED CONNECTIONS | | | COMPLYING WITH CITY OF WEST PALM BEACH PUBLIC WORKS | | | DEPARTMENT AND FBC PL SECTION 1003 SHALL BE SUBMITTED. | | | SEE WPB PUBLIC WORKS DEPT. STANDARD DETAIL GS-7 | | | (CONCRETE) AND GS-7.1 (HYDRO-MECHANICAL) FOR GUIDE. | | | PLEASE INCLUDE THE GREASE TRAP CALCULATIONS ON THE SAME | | | PAGE IN THE SUBMITTAL. | | | A SEPARATE PLUMBING SUB-PERMIT IS REQUIRED FOR THE | | | BACKFLOW PREVENTOR. | | | | | | PLUMBING COMMENTS: DENIED | | | 1.SECOND REQUEST: PER FBC ACC 609.4, GRAB BARS SHALL BE | | | INSTALLED IN A HORIZONTAL POSITION, 33 INCHES MINIMUM | | | AND 36 INCHES MAXIMUM ABOVE THE FINISH FLOOR MEASURED | | | TO THE TOP (NOT THE CENTER) OF THE GRIPPING SURFACE | | | | | | 2.GENERAL COMMENT; PER WPB FBC 107.2.1, PLAN DRAWINGS | | | P2.0 AND P3.0 SHALL BE CONFIGURED AND RECONCILED WITH | | | COINCIDING RISER DIAGRAMS ON P5.0. COMPLIED | | | NEW COMMENT; P5.0 CORRECTLY SHOWS THE MEN?S TOILET ROOM | | | WITH THE URINAL CONNECTING TO THE BUILDING DRAIN | | | DOWNSTREAM OF THE WATER CLOSET, LAVATORY AND FLOOR | | | DRAIN. P2.0 APPEARS TO SHOW THE WATER CLOSET | | | DISCHARGING TO THE BUILDING DRAIN WITH THE URINAL | | | SERVING AS THE VENT AND ALSO CONNECTING TO THE BUILDING | | | DRAIN WITH THE LAVATORY WET VENTING IT AND THE FLOOR | | | DRAIN (AS SHOWN ON P5.0). PER WPB FBC 107.2.1, CLARIFY. | | | | | | 3.PLAN SHEET P1.0 | | | SECOND REQUEST: PER WPB FBC 107.2.1, SUBMIT SITE PLANS. | | | TO BE CLEAR, CIVIL DRAWINGS SHOWING SEWER AND WATER ARE | | | REQUIRED. | | | SECOND REQUEST: PER WPB FBC 107.2.1, SPECIFY THE TRAP | | | PRIMER AND PROVIDE A DETAIL FOR THE TRAP PRIMER. | | | | | | 4. PLAN SHEET P2.0 | | | SECOND REQUEST: PROVIDE DETAIL FOR CONDENSATE DRYWELL | | | | | | 5.P4.0 | | | NEW COMMENT: REGARDING S-4 PEDESTAL SINK; ENGINEER | | | RESPONSE IS THAT SINK IS FOR FOOD PREP (NOTED ON | | | REVISED SCHEDULE P1.0) AND THAT THE DRAIN IS REVISED TO | | | A FLOOR SINK CONNECTION. PER WPB FBC 107.2.1, PROVIDE | | | THE FOLLOWING: | | | IDENTIFY THE FLOOR SINK ON P2.0 AND P5.0 | | | PROVIDE A DETAIL OF THE SINK, FLOOR SINK AND SIZED | | | INDIRECT WASTE THROUGH AN AIR GAP SHOWING COMPLIANCE | | | WITH FBC PL 802.1.1 | | | ON P1.0 FIXTURE SCHEDULE INDICATE INDIRECT FOR WASTE | | | | | | 6.P6.0 | | | NEW COMMENT: PER WPB FBC 107.2.1, INDICATE ON P6.0, | | | DETAIL 3 THAT THE FOOT PEDAL IS FOR S-4 OR ON P1.0, S-4 | | | DESCRIPTION , ADD FOOT PEDALS AND REFER TO P6.0/DETAIL | | | 3. | | | | | | 7.SEE PLAN SHEET A3.0: | | | SECOND REQUEST; PER WPB FBC 107.2.1, PROVIDE | | | CALCULATIONS AND SIZING FOR VERTICAL LEADERS AND | | | HORIZONTAL GUTTERS. TO BE CLEAR, SHOW THE CALCULATIONS | | | AND THE SIZING ON THE PLAN. ADDITIONALLY, INDICATE | | | SQUARE FOOTAGE AND GPM OF AREAS BEING DRAINED AND | | | INDICATE ON THE PLAN, GUTTER AND DOWNSPOUT SIZE. NOTES | | | 11, 13 AND 14 ON A3.0 ARE ACKNOWLEDGED. | | | NEW COMMENT: AS THERE IS NO STORM PIPING IN THE | | | BUILDING, PER WPB FBC 107.2.1, DELETE REFERENCES TO | | | STORM PIPING, ROOF DRAINS, OVERFLOW DRAINS, DOWNSPOUT | | | NOZZLES, ETC. IN THE FIXTURE SCHEDULE(P1.0) AND WASTE & | | | VENT NOTES (P2.0). | | | | | | NEW COMMENTS: | | | | | | 1. P5.0 INDICATES 6 INCH GREASY WASTE IN THE WASTE/VENT | | | LINE LEGEND. WILL THE GREASE INTERCEPTOR COME FROM THE | | | MANUFACTURER WITH INLETS/OUTLETS SIZED TO ACCOMMODATE | | | THE 6 INCH DRAIN; WILL THE CIVIL DRAWINGS BE SIZED TO | | | RECEIVE SAID SIZE. ADDITIONALLY, P1.0 PLUMBING FIXTURE | | | SUMMARY INDICATES 4 INCH GREASY WASTE AS WELL AS 4 INCH | | | SANITARY WASTE. PER WPB FBC 107.2.1, CLARIFY. PER WPB | | | FBC 107.2.1, ON P5.0, SHOW SIZE(S) OF SANITARY AND | | | GREASY WASTE BUILDING DRAINS. | | | | | | 2. PER WPB FBC 107.2.1, PROVIDE PIPE HANGER DETAIL WITH | | | A NOTE STATING, "HORIZONTAL PIPE SHALL BE SUPPORTED IN | | | ACCORDANCE WITH FBC PL TABLE 308.5." | | | | | | 3. REGARDING S-3 THREE-COMPARTMENT SINK; IDENTIFY IN | | | FIXTURE SCHEDULE DESCRIPTION IF THIS IS FOOD PREP OR | | | POT WASH. IF FOOD PREP, PROVIDE A DETAIL OF THE | | | THREE-COMPARTMENT SINK, FLOOR SINK AND SIZED INDIRECT | | | WASTE PIPES THROUGH AN AIR GAP SHOWING COMPLIANCE WITH | | | FBC PL 802.1.1. EACH WELL OF A MULTIPLE-COMPARTMENT | | | SINK SHALL DISCHARGE INDEPENDENTLY TO THE WASTE | | | RECEPTOR. | | | | | | 4. PER WPB FBC 107.2.1, AS A KITCHEN EQUIPMENT PLUMBING | | | FIXTURES NOTED ON P1.0 FIXTURE SCHEDULE (S-1, S-2, S-3 | | | AND S-4) ARE INCOMPLETE IN DESCRIPTION, PROVIDE NOTE | | | FOR SAID ITEMS, REFERRING TO A2.1 EQUIPMENT SCHEDULE; | | | SINKS AND DISHWASHERS FOR FAUCETS/ACCESSORIES (I.E. | | | FAUCET FOR S-2) INFORMATION. | | | | | | | | | 5. P2.0 NOTE 9. PER WPB FBC 107.2.1, PROVIDE | | | SPECIFICATION, POWER SOURCE AND DETAIL FOR HEAT TRACE. | | | YOU CALL FOR HEAT TRACE APPLIED TO UNDERGROUND GREASY | | | WASTE BELOW FREEZER/COOLER BUT DON?T CALL OUT ANY SORT | | | OF INSULATION. PER WPB FBC 107.2.1, CLARIFY. | | | | | | 6. P2.0 NOTE 12. DETAIL DESCRIBED IS NOT SHOWN. PER WPB | | | FBC 107.2.1, CLARIFY. | | | | | | 7. PER WPB FBC 107.2.1, PROVIDE A DETAIL OF THE | | | BACKFLOW PREVENTER (BFP-1). INCLUDE SUPPORTS, STRAINER, | | | RELIEF VENT DISCHARGE PIPING WITH AIR GAP TO FLOOR SINK | | | OR HUB DRAIN (TO SANITARY, NOT GREASY WASTE). COMPLY | | | WITH MANUFACTURER?S RECOMMENDATIONS PER FBC PL 301.7. | | | SEE EXCERPTS FROM WATTS INSTALLATION, MAINTENANCE, & | | | REPAIR SERIES 009 AND LF009 REDUCED PRESSURE ZONE | | | ASSEMBLIES RP/IS-009 BELOW | | | A.INDOORS ? FIGURE 1 FOR INDOOR INSTALLATIONS, IT IS | | | IMPORTANT THAT THE ASSEMBLY BE EASILY ACCESSIBLE TO | | | FACILITATE TESTING AND SERVICING. IF IT IS LOCATED IN A | | | LINE CLOSE TO A WALL, BE SURE THE TEST COCKS ARE EASILY | | | ACCESSIBLE. A DRAIN LINE AND AIR GAP (SEE LITERATURE | | | ES-AG/EL/TC) SHOULD BE PIPED FROM THE RELIEF VALVE | | | CONNECTION AS SHOWN, WHERE EVIDENCE OF DISCHARGE WILL | | | BE CLEARLY VISIBLE AND SO THAT WATER DAMAGE WILL NOT | | | OCCUR. THEREFORE, NEVER INSTALL IN CONCEALED LOCATIONS. | | | B.WE RECOMMEND A STRAINER BE INSTALLED AHEAD OF 009 AND | | | LF009 SERIES ASSEMBLIES TO PROTECT THE INTERNAL | | | COMPONENTS FROM UNNECESSARY FOULING. | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. ALL PLANS TO BE SIGNED | | | AND SEALED BY THE DESIGNER AS REQUIRED BY FAC AND FS. | | | | | | JERALD SMITH | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | EMAIL [email protected] | | | MOBILE 561-243-0882 | | | PLEASE NOTE THAT I TYPICALLY WORK ON TUESDAYS AND | | | THURSDAYS. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2021-03-30 |
|
|
Cont ID |
|
| Sent By |
jesmith |
Date |
2021-03-30 |
Time |
13:57 |
Rev Time |
0.00 |
| Received By |
jesmith |
Date |
2021-03-23 |
Time |
16:24 |
Sent To |
|
|
| Notes |
| 2021-03-30 13:38:49 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2020 7TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1 | | | WPB CCCM=WEST PALM BEACH CROSS-CONNECTION CONTROL | | | MANUAL REVISED 2017 | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 | | | 7TH EDITION | | | FBC ACC = FLORIDA ACCESSIBILITY CODE 2020 7TH EDITION | | | FBC PL = FLORIDA PLUMBING CODE 2020 7TH EDITION | | | FBC FG = FLORIDA FUEL GAS CODE 2020 7TH EDITION | | | NFPA 54 = NATIONAL FUEL GAS CODE | | | NFPA 58 = LIQUIFIED PETROLEUM GAS CODE | | | NFPA 96 = STANDARD FOR VENTILATION CONTROLAND FIRE | | | PROTECTION OF COMMERCIAL COOKING OPERATIONS 2017 | | | FAC= FLORIDA ADMINISTRATIVE CODE | | | FS = FLORIDA STATUTES | | | | | | 21010992 1225 PALM BEACH LAKES BLVD | | | | | | 1ST REVIEW | | | PLUMBING COMMENTS: DENIED | | | A REVIEW OF MINIMUM PLUMBING FIXTURE REQUIREMENTS AS | | | REQUIRED BY FBC ACC IS PART OF THE PLUMBING REVIEW | | | PROCESS BUT IS TYPICALLY ADDRESSED ON THE ARCHITECTURAL | | | PLANS. ANY COMMENTS CONCERNING THESE REQUIREMENTS MUST | | | BE SATISFACTORILY ADDRESSED PRIOR TO A PLUMBING REVIEW | | | APPROVAL. | | | | | | | | | 1.FBC ACC COMMENTS | | | A.TOILET PAPER DISPENSERS SHALL COMPLY WITH 309.4 AND | | | SHALL BE 7 INCHES MINIMUM AND 9 INCHES MAXIMUM IN FRONT | | | OF THE WATER CLOSET MEASURED TO THE CENTERLINE OF THE | | | DISPENSER. THE OUTLET OF THE DISPENSER SHALL BE 15 | | | INCHES MINIMUM AND 48 INCHES MAXIMUM ABOVE THE FINISH | | | FLOOR AND SHALL NOT BE LOCATED BEHIND GRAB BARS PER FBC | | | ACC 604.8. | | | B.PER FBC ACC 609.4, GRAB BARS SHALL BE INSTALLED IN A | | | HORIZONTAL POSITION, 33 INCHES MINIMUM AND 36 INCHES | | | MAXIMUM ABOVE THE FINISH FLOOR MEASURED TO THE TOP (NOT | | | THE CENTER) OF THE GRIPPING SURFACE | | | | | | 2.AS THERE IS NO DRINKING FOUNTAIN PROVIDED, IT IS | | | NOTED THAT PER FBC PL 410.4, WHERE RESTAURANTS PROVIDE | | | DRINKING WATER IN A CONTAINER FREE OF CHARGE, DRINKING | | | FOUNTAINS SHALL NOT BE REQUIRED IN THOSE RESTAURANTS. | | | PER WPB FBC 107.2.1, PROVIDE A NOTE ON THE P1.0 GENERAL | | | NOTES AND A1.0 KEY NOTES STATING "PROVIDE PERMANENT | | | SIGN AT DRINK DISPENSER AND COUNTER AS FOLLOWS: | | | DRINKING WATER AND CUP PROVIDED AT NO CHARGE" | | | | | | 3.GENERAL COMMENT; PER WPB FBC 107.2.1, PLAN DRAWINGS | | | P2.0 AND P3.0 SHALL BE CONFIGURED AND RECONCILED WITH | | | COINCIDING RISER DIAGRAMS ON P5.0. | | | | | | 4.PLAN SHEET P1.0 | | | A.NOTE 3 IS CALLING FOR CONTRACTOR TO REVISE SANITARY | | | TO ACCOMMODATE SANITARY SEWER ON THE SITE PLAN. IT IS | | | THE DESIGNER'S RESPONSIBILITY TO DETERMINE THE CORRECT | | | CONFIGURATION OF THE SANITARY BUILDING DRAIN AND GREASY | | | WASTE/INTERCEPTOR. PER WPB FBC 107.2.1, SUBMIT SITE | | | PLANS AND ADJUST BUILDING PLUMBING AS REQUIRED TO | | | RECONCILE. | | | B.NOTE 4 SHALL READ "PROVIDE TRAP SEAL PROTECTION FOR | | | ALL FLOOR DRAINS COMPLYING WITH FBC PL 1002.4.1, | | | 1002.4.1.1, 1002.4.1.2, 1002.4.1.3 AND 1002.4.1.4. DEEP | | | SEAL TRAPS ARE NOT COMPLIANT." | | | ADDITIONALLY, PER WPB FBC 107.2.1, SPECIFY THE TRAP | | | PRIMER AND PROVIDE A DETAIL FOR THE TRAP PRIMER. | | | C. NOTE 16; ADD TO NOTE THE VERBIAGE "AND AS REQUIRED | | | BY FBC PL 604.9." | | | D.NOTE 21- CALLS FOR PROVIDING CONDENSATE DRAINS FOR | | | ALL A/C UNITS. PER WPB FBC 107.2.1, PROVIDE RISER | | | DIAGRAM TO CORRESPOND WITH PLAN DRAWINGS ROUTING, | | | SIZING, TERMINATION. | | | E.NOTE 22- AS THIS PLAN IS FOR PERMITTING, PLEASE NOTE, | | | ANY CHANGES TO EQUIPMENT, ETC. WILL REQUIRE REVISED | | | DRAWINGS WHICH SHALL BE SUBMITTED AND APPROVED PRIOR TO | | | INSPECTION. PROCCED AT YOUR OWN RISK. | | | WPB FBC 107.3.4.2 DEFERRED SUBMITTALS. FOR THE PURPOSES | | | OF THIS SECTION, DEFERRED SUBMITTALS ARE DEFINED AS | | | THOSE PORTIONS OF THE DESIGN THAT ARE NOT SUBMITTED AT | | | THE TIME OF THE APPLICATION AND THAT ARE TO BE | | | SUBMITTED TO THE BUILDING OFFICIAL WITHIN A SPECIFIED | | | PERIOD. DEFERRAL OF ANY SUBMITTAL ITEMS SHALL HAVE THE | | | PRIOR APPROVAL OF THE BUILDING OFFICIAL. THE REGISTERED | | | DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE SHALL LIST | | | THE DEFERRED SUBMITTALS ON THE CONSTRUCTION DOCUMENTS | | | FOR REVIEW BY THE BUILDING OFFICIAL. THIS LIST SHALL BE | | | PROVIDED PRIOR TO PERMIT ISSUANCE. | | | DOCUMENTS FOR DEFERRED SUBMITTAL ITEMS SHALL BE | | | SUBMITTED TO THE REGISTERED DESIGN PROFESSIONAL IN | | | RESPONSIBLE CHARGE WHO SHALL REVIEW THEM AND FORWARD | | | THEM TO THE BUILDING OFFICIAL WITH A NOTATION | | | INDICATING THAT THE DEFERRED SUBMITTAL DOCUMENTS HAVE | | | BEEN REVIEWED AND FOUND TO BE IN GENERAL CONFORMANCE TO | | | THE DESIGN OF THE BUILDING. THE DEFERRED SUBMITTAL | | | ITEMS SHALL NOT BE INSTALLED UNTIL THE DEFERRED | | | SUBMITTAL DOCUMENTS HAVE BEEN APPROVED BY THE BUILDING | | | OFFICIAL. | | | F.GREASE TRAP CALCULATIONS ARE INCLUDED ON THIS | | | DRAWING. PLEASE NOTE, A SEPARATE PERMIT IS REQUIRED FOR | | | THE GREASE INTERCEPTOR. A PLAN WITH DETAIL OF THE | | | GREASE INTERCEPTOR TO BE INSTALLED AND REQUIRED | | | CONNECTIONS COMPLYING WITH CITY OF WEST PALM BEACH | | | PUBLIC WORKS DEPARTMENT AND FBC PL SECTION 1003 SHALL | | | BE SUBMITTED. SEE WPB PUBLIC WORKS DEPT. STANDARD | | | DETAIL GS-7 (CONCRETE) AND GS-7.1 (HYDRO-MECHANICAL) | | | FOR GUIDE. PLEASE INCLUDE THE GREASE TRAP CALCULATIONS | | | ON THE SAME PAGE IN THE SUBMITTAL. | | | G. PER WPB 107.2.1, BFP-1 SCHEDULED BACKFLOW PREVENTORS | | | SHALL BE SPECIFIED BY THEIR LEAD-FREE MODEL NUMBER. | | | ACTUAL MANUFACTURER'S SPECIFICATION/INSTALLATION MANUAL | | | SHALL BE SUBMITTED, APPROVED, IN PLACE AND PLAN SHALL | | | BE REVISED TO REFLECT FOR FINAL INSPECTION. SEE COMMENT | | | 4 (E) NOTE 22. | | | | | | 5. PLAN SHEET P2.0 | | | A. MEN'S RESTROOM: PER FBC PL 912.1, ONLY BATHROOM | | | GROUP FIXTURES MAY CONNECT TO THE WET VENT. URINAL AND | | | HAND SINK SHOWN CONNECTED ARE NOT CONSIDERED BATHROOM | | | GROUP FIXTURES (SEE FBC PL CHAPTER 2, DEFINITIONS, | | | BATHROOM GROUP). ADDITIONALLY, P5.0 SANITARY RISER | | | DIAGRAM AND P2.0 DO NOT MATCH. P5.0 SANITARY RISER | | | DIAGRAM ALSO DOES NOT SHOW THE URINAL UR-1 AND NOTES | | | MSB-1/S-2, BUT NO S-1 ON P2.0. PER WPB FBC 107.2.1, | | | CLARIFY AND RECONCILE. SEE COMMENT A. GENERAL COMMENT | | | B.REGARDING NOTE 1, PER WPB PL 802.4, FOR OTHER THAN | | | HUB DRAINS THAT RECEIVE ONLY CLEAR-WATER WASTE AND | | | STANDPIPES (IE. FIRE PROTECTION TEST DRAIN), A | | | REMOVABLE STRAINER OR BASKET SHALL COVER THE OUTLET OF | | | WASTE RECEPTORS. IT IS THE DESIGNER?S RESPONSIBILITY TO | | | DETERMINE WHETHER A HUB DRAIN COMPLIES, OR IF A FLOOR | | | SINK IS REQUIRED. PER WPB FBC 107.2.1, CLARIFY AND | | | DESIGNATE ACCORDINGLY. IF THE DRAINS IN QUESTION | | | RECEIVE ONLY CLEAR WATER WASTE, THEY MAY REMAIN AS HUB | | | DRAINS; HOWEVER, CLEAR WATER WASTE IS NOT GREASY WASTE | | | AND AS SUCH SHALL NOT DISCHARGE TO THE GREASY WASTE. | | | C.REGARDING NOTE 2 AND 5, CONDENSATE FROM A/C | | | CONDENSATE SHALL NOT DISCHARGE TO THE GREASY WASTE PER | | | FBC PL 1003.2. ADDITIONALLY, PER WPB CODE OF ORDINANCE | | | CHAPTER 90, ARTICLE 3, SECTION 90-12B5, A/C CONDENSATE | | | SHALL NOT DISCHARGE TO THE CITY UTILITIES SANITARY | | | SEWAGE INFRASTRUCTURE WITHOUT PERMISSION FROM THE | | | UTILITIES DEPARTMENT. YOU MAY CONTACT MR. MANNY | | | GONZALES IN ENGINEERING AT 561-494-1128 FOR ADDITIONAL | | | INFORMATION. MOVING FORWARD, DISCHARGE THE CONDENSATE | | | TO AN EXTERIOR DRYWELL; PER WPB FBC 107.2.1, PROVIDE | | | ROUTING AND DRYWELL DETAIL. | | | D.REGARDING NOTE 3, NOTES THAT BEVERAGE UNIT WASTE TO | | | DISCHARGE TO FLOOR SINK. THE FLOOR SINK INDICATED | | | DISCHARGES TO THE GREASY WASTE; PER FBC PL 1003.2, | | | WASTES THAT DO NOT REQUIRE TREATMENT OR SEPARATION | | | SHALL NOT BE DISCHARGED INTO ANY INTERCEPTOR OR | | | SEPARATOR. | | | E.REGARDING NOTE 4 AND 7, CONDENSATE FROM COOLER | | | EVAPORATOR SHALL NOT DISCHARGE TO THE GREASY WASTE PER | | | FBC PL 1003.2. ADDITIONALLY, PER WPB CODE OF ORDINANCE | | | CHAPTER 90, ARTICLE 3, SECTION 90-12B5, A/C CONDENSATE | | | (INTERPRET THIS AS ANY CONDENSATION FROM EVAPORATOR | | | COILS) SHALL NOT DISCHARGE TO THE CITY UTILITIES | | | SANITARY SEWAGE INFRASTRUCTURE WITHOUT PERMISSION FROM | | | THE UTILITIES DEPARTMENT. YOU MAY CONTACT MR. MANNY | | | GONZALES IN ENGINEERING AT 561-494-1128 FOR ADDITIONAL | | | INFORMATION. MOVING FORWARD, DISCHARGE THE CONDENSATE | | | TO AN EXTERIOR DRYWELL; PER WPB FBC 107.2.1, PROVIDE | | | ROUTING AND DRYWELL DETAIL. | | | F.REGARDING NOTE 6, PER WPB FBC 107.2.1, CONFIRM THAT | | | ALL DRAINS ON THIS RUN ARE ALLOWED TO CONNECT TO GREASY | | | WASTE AS ALLOWED IN FBC PL 1003.2. | | | G.REGARDING NOTE 11, NOTES THAT S/S DRINK MACHINE WASTE | | | TO DISCHARGE TO FLOOR SINK. THE FLOOR SINK INDICATED | | | DISCHARGES TO THE GREASY WASTE; PER FBC PL 1003.2, | | | WASTES THAT DO NOT REQUIRE TREATMENT OR SEPARATION | | | SHALL NOT BE DISCHARGED INTO ANY INTERCEPTOR OR | | | SEPARATOR | | | J.REGARDING NOTE 13, COULD NOT LOCATE ON THE PLAN. | | | PLEASE CLARIFY. | | | | | | 6.P4.0 | | | A.SINK S-4 IS DESIGNATED A PREP SINK. IS THIS A FOOD | | | PREP SINK? PLEASE CLARIFY. PROVIDE MANUFACTURER'S DATA | | | FOR AERO MANUFACTURING PEDESTAL SINK. IF A FOOD PREP | | | SINK IT MUST DISCHARGE TO A FLOOR SINK THROUGH AN AIR | | | GAP COMPLYING WITH THE REQUIREMENTS OF FBC PL 802.1.1. | | | B.MSB-1/S-2 IS INCORRECTLY IDENTIFIED AS S-4 ON P2.0 | | | AND P4.0 FLOOR PLANS. PER WPB FBC 107.2.1, CLARIFY AND | | | RECONCILE. | | | | | | 7.P5.0 WATER RISER DIAGRAM. SHOW ON COLD/HOT/TEMPERED | | | WATER DISTRIBUTION BRANCH TO S-287, S-288 WATER | | | FILTERS. INDICATE TEMPERATURE OF HOT WATER. SHOW | | | LOCATIONS AND PROVIDE SCHEDULE/SPEC FOR ALL BACKFLOW | | | PREVENTERS INCLUDING THOSE PROVIDED BY BEVERAGE | | | DISPENSER PROVIDER. ALL BACKFLOW PREVENTERS SHALL BE | | | LEAD FREE AND MEET THE REQUIREMENTS OF FBC PL SECTION | | | 608 FOR THEIR DESIGNATED USE. | | | | | | 8. PER WPB FBC 107.2.1, PROVIDE MANUFACTURER'S | | | SPECIFICATION/INSTALLATION MANUAL FOR THE WATER | | | HEATER(S). WATER HEATER AS SHOWN (PLAN VIEWS SEEM TO | | | SHOW A TANK TYPE AND TANKLESS; IT IS UNCLEAR) ON P6.0 | | | DETAIL 9 WATER HEATER SCHEDULE, DETAIL 7 WATER | | | FILTRATION AND A2.1 EQUIPMENT SCHEDULE ARE | | | BRADFORD-WHITE EF100T199E3N 100 GALLON STORAGE TANK | | | TYPE BOTTOM FED. WATER HEATERS PER P1.0 SCHEDULE, P6.0 | | | WATER HEATER SCHEMATIC AND P5.0 RISER DIAGRAM ARE | | | TANKLESS. PER WPB FBC 107.2.1, CLARIFY TANK TYPE OR | | | TANKLESS AND CLEARLY INDICATE ON THE PLANS. | | | IF TANKLESS WATER HEATERS ARE TO BE USED THEN REMOVE | | | ALL REFERENCE TO TANK TYPE WATER HEATER. REVISE | | | APPLICABLE DETAILS AND NOTES TO REFLECT THE TANKLESS | | | WATER HEATERS. | | | IF A TANK TYPE WATER HEATER IS THE APPLICABLE WATER | | | HEATER THEN REMOVE OR REVISE ALL REFERENCE TO TANKLESS | | | WATER HEATERS. REVISE WATER HEATER SCHEDULE ON P1.0 TO | | | REFLECT, INCLUDE MANUFACTURER, MODEL, CAPACITY. REVISE | | | WATER HEATER SCHEMATIC TO REFLECT. INCLUDE | | | RECIRCULATION PUMP, TEMPERATURE OF THE HOT WATER, CW, | | | HW, VALVES (INCLUDING VACUUM RELIEF VALVE IF APPLICABLE | | | FBC PL 504.2), THERMAL EXPANSION CONTROL DEVICE | | | (INCLUDING SIZE), T&P DISCHARGE (INCLUDING TERMINATION) | | | AND WATER HEATER PAN AND DRAIN (INCLUDING TERMINATION) | | | PER WPB FPC 107.2.1; COMPLY WITH FBC PL 607.3, 503.1, | | | 504.1, 504.4, 504.4.1, 504.5, 504.6, 504.7, 504.7.1 AND | | | 504.7.2. | | | PLEASE NOTE THAT P3.0, NOTE 18 INDICATES A SINGLE | | | EXHAUST FOR THE WATER HEATER REFERENCING P6.0, DETAIL | | | 2. THIS NEEDS TO BE ADDRESSED AND CLARIFIED PER WPB FBC | | | 107.2.1. | | | | | | 9.PER WPB FBC 107.2.1, PROVIDE AN ENGINEERED DETAIL FOR | | | SUPPORT OF WATER HEATER(S) INCLUDING ANCHORS. | | | | | | 10.P6.0 | | | A. PER WPB FBC 107.2.1, ADVISE AS TO WHAT FIXTURE | | | DETAIL 3; FOOT PEDAL APPLIES TO. | | | B. PROVISO: SEE DETAIL 2. PER WPB FBC 107.2.1, THE | | | MANUFACTURE'S SPECIFICATION/INSTALLATION MANUAL FOR | | | WATER HEATER VENT UBBINK OR HEAT FAB SAF-T VENT SC | | | SHALL BE SUBMITTED, APPROVED, IN PLACE AND PLAN SHALL | | | BE REVISED TO REFLECT FOR FINAL INSPECTION. SEE COMMENT | | | 4 (E) NOTE 22. | | | C. DETAIL 7; NOTE 4: PER WPB FBC 107.2.1, SPECIFY LEAD | | | FREE MODEL FOR BACKFLOW PREVENTER. | | | | | | 11. PER WPB FBC 107.2.1, PROVIDE MATERIAL SPECIFICATION | | | OF PIPE, VALVES AND FITTINGS FOR ALL PIPING SYSTEMS | | | INCLUDING BUT NOT LIMITED TO SANITARY, DOMESTIC WATER | | | AND FILTERED WATER; SHOW COMPLIANCE WITH FBC PL | | | SECTIONS 607 (PROVIDE AN ADDITIONAL NOTE THAT ALL | | | MATERIALS SHALL BE LEAD FREE) AND 702. ADDITIONALLY, | | | PER FBC PL E607.5, PROVIDE INSULATION SPECIFICATION FOR | | | HOT WATER TO COMPLY WITH FBC EC 607.5 AND C404.4. | | | | | | 12.PER WPB FBC 107.2.1, SPECIFY MANUFACTURER, MODEL FOR | | | MV-1 MIXING VALVE WITH ASSE 1070 COMPLIANT PRODUCT AS | | | REQUIRED BY FBC PL 419.5. | | | | | | 13.SEE PLAN SHEET A3.0: | | | A.SEE BUILDING REVIEWER'S COMMENTS | | | 1)PER FBC PL 1106.3, VERTICAL LEADERS SHALL BE SIZED | | | BASED ON THE FLOW RATE FROM HORIZONTAL GUTTERS OR THE | | | MAXIMUM FLOW RATE THROUGH ROOF DRAINS. THE FLOW RATE | | | THROUGH VERTICAL LEADERS SHALL NOT EXCEED THAT | | | SPECIFIED IN TABLE 1106.3. | | | 2)PER FBC PL 1106.5, WHERE SCUPPERS ARE USED FOR | | | PRIMARY ROOF DRAINAGE OR FOR SECONDARY (EMERGENCY | | | OVERFLOW) ROOF DRAINAGE OR BOTH, THE QUANTITY, SIZE, | | | LOCATION AND INLET ELEVATION OF THE SCUPPERS SHALL BE | | | CHOSEN TO PREVENT THE DEPTH OF PONDING WATER ON THE | | | ROOF FROM EXCEEDING THE MAXIMUM WATER DEPTH THAT THE | | | ROOF WAS DESIGNED FOR AS DETERMINED BY SECTION 1611.1 | | | OF THE FLORIDA BUILDING CODE, BUILDING. SCUPPER | | | OPENINGS SHALL BE NOT LESS THAN 4 INCHES (102 MM) IN | | | HEIGHT AND HAVE A WIDTH THAT IS EQUAL TO OR GREATER | | | THAN THE CIRCUMFERENCE OF A ROOF DRAIN SIZED FOR THE | | | SAME ROOF AREA. THE FLOW THROUGH THE PRIMARY SYSTEM | | | SHALL NOT BE CONSIDERED WHEN LOCATING AND SIZING | | | SECONDARY SCUPPERS. | | | B.PER FBC PL 1106.6, HORIZONTAL GUTTERS SHALL BE SIZED | | | BASED ON THE FLOW RATE FROM THE ROOF SURFACE. THE FLOW | | | RATE IN HORIZONTAL GUTTERS SHALL NOT EXCEED THAT | | | SPECIFIED IN TABLE 1106.6. | | | C.PER WPB FBC 107.2.1, PROVIDE CALCULATIONS AND SIZING | | | FOR VERTICAL LEADERS, SCUPPERS AND HORIZONTAL GUTTERS. | | | | | | END OF COMMENTS. | | | A COMPREHENSIVE REVIEW COULD NOT BE ACCOMPLISHED AT | | | THIS TIME. PLEASE RESUBMIT CLEARLY LEGIBLE PLANS AND A | | | RESPONSE NARRATIVE ADDRESSING THE GAS/PLUMBING COMMENTS | | | FROM THE PRIOR REVIEW. | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS.ALL PLANS TO BE SIGNED | | | AND SEALED BY THE DESIGNER AS REQUIRED BY FAC AND FS. | | | | | | JERALD SMITH | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | EMAIL [email protected] | | | MOBILE 561-246-0882 | | | PLEASE NOTE THAT I TYPICALLY WORK ON TUESDAYS AND | | | THURSDAYS |
|
|
| Review Stop |
P-GREASE |
GREASE INTERCEPTOR/TRAP REVIEW |
| Rev No |
2 |
Status |
P |
Date |
2021-06-29 |
|
|
Cont ID |
|
| Sent By |
jesmith |
Date |
2021-06-29 |
Time |
16:04 |
Rev Time |
0.00 |
| Received By |
jesmith |
Date |
2021-06-29 |
Time |
16:02 |
Sent To |
|
|
| Notes |
| 2021-06-29 16:04:53 | 21010992 1225 PALM BEACH LAKES BLVD | | | | | | | | | PLUMBING COMMENTS: GREASE INTERCEPTOR APPROVED | | | | | | ALL WORK PER STATE AND CITY CODES SUBJECT TO FIELD | | | INSPECTOR'S APPROVAL | | | | | | BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE | | | COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN | | | PROFESSIONAL, CONTRACTORS OR THEIR REPRESENTATIVES FROM | | | THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL, STATE AND | | | NATIONAL CODES AND STANDARDS IN EFFECT AT THE TIME OF | | | PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK OF EVERY | | | ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM | | | REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES | | | / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO | | | AVOID VOIDING OF THE PERMIT. | | | | | | A SEPARATE SUB PERMIT IS REQUIRED FOR THE GREASE | | | INTERCEPTOR | | | | | | | | | | | | JERALD SMITH | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | EMAIL [email protected] | | | MOBILE 561-243-0882 | | | PLEASE NOTE THAT I TYPICALLY WORK ON TUESDAYS AND | | | THURSDAYS. |
|
|
| Review Stop |
P-GREASE |
GREASE INTERCEPTOR/TRAP REVIEW |
| Rev No |
1 |
Status |
N |
Date |
2021-05-25 |
|
|
Cont ID |
|
| Sent By |
jesmith |
Date |
2021-05-25 |
Time |
16:02 |
Rev Time |
0.00 |
| Received By |
jesmith |
Date |
2021-05-25 |
Time |
14:35 |
Sent To |
|
|
| Notes |
| 2021-05-25 14:35:01 | PLEASE NOTE, A SEPARATE PLUMBING SUB-PERMIT IS REQUIRED | | | FOR THE GREASE INTERCEPTOR. A PLAN WITH DETAIL OF THE | | | GREASE INTERCEPTOR TO BE INSTALLED AND REQUIRED | | | CONNECTIONS COMPLYING WITH CITY OF WEST PALM BEACH | | | PUBLIC WORKS DEPARTMENT AND FBC PL SECTION 1003 SHALL | | | BE SUBMITTED. SEE WPB PUBLIC WORKS DEPT. STANDARD | | | DETAIL GS-7 (CONCRETE) AND GS-7.1 (HYDRO-MECHANICAL) | | | FOR GUIDE. PLEASE INCLUDE THE GREASE TRAP CALCULATIONS | | | ON THE SAME PAGE IN THE SUBMITTAL. |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
3 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2021-06-24 |
Time |
09:45 |
Rev Time |
0.00 |
| Received By |
|
Date |
2021-06-24 |
Time |
|
Sent To |
|
|
| Notes |
| 2021-06-24 09:36:10 | DEFERRED SUBMITTALS/ BUILDING PROVISO, ROOFING PRODUCT | | | APPROVALS TO BE ACCOMPANIED BY ROOF PERMIT. J. WITMER |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
2 |
Status |
F |
Date |
2021-05-25 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2021-05-25 |
Time |
08:57 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2021-05-24 |
Time |
16:02 |
Sent To |
|
|
| Notes |
| 2021-05-25 08:51:48 | NO ROOFING PRODUCT APPROVALS COULD BE REVIEWED SINCE | | | THE WIND DESIGN CRITERIA NOR PRESSURES WERE FOUND. SEE | | | BUILDING REVIEW. | | | J. WITMER BUILDING PLANS EXAMINER. |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2021-03-01 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2021-03-01 |
Time |
14:22 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2021-03-01 |
Time |
14:22 |
Sent To |
|
|
| Notes |
| 2021-03-01 14:24:27 | ROOFING: FOR ALL ROOFING PRODUCTS PLEASE IDENTIFY ALL | | | ROOFING SUB-SYSTEMS AND THEIR ASSOCIATED PRESSURES FOR | | | ROOF ZONE # 1. REVIEW THE PRODUCT APPROVAL LIMITATIONS, | | | IF ENHANCED FASTENING IS ALLOWED FOR ROOF ZONES 2 & 3. | | | FASTENER DENSITIES SHALL BE INCREASED FOR BOTH | | | INSULATION & THE BASE SHEET AS CALCULATED IN COMPLIANCE | | | WITH ROOFING APPLICATION STANDARDS RAS 117. CALCULATION | | | PREPARED, SIGNED AND SEALED BY A FLORIDA REGISTERED | | | PROFESSIONAL ENGINEER OR REGISTERED ARCHITECT. | | | 1609.6.4.4.1 COMPONENTS & CLADDING. | | | | | | JAMES A. WITMER BN, PX, SFP, CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT | | | 401 CLEMATIS ST. WEST PALM BEACH. FL 33402 | | | TEL: 561-805-6717 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | DEVELOPMENT SERVICES HOME PAGE | | | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP | | | | | | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS | | | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS | | | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO | | | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE | | | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. | | | | | | MEMBER OF BOAF: BUILDING OFFICIALS ASSOCIATION OF | | | FLORIDA SAVING LIVES AND PROPERTY SINCE 1953. | | | | | | | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
5 |
Status |
P |
Date |
2021-07-08 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2021-07-08 |
Time |
10:55 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2021-07-08 |
Time |
10:55 |
Sent To |
|
|
| Notes |
| 2021-07-08 10:56:24 | PROVIDED VIA EMAIL, ADDED TO SIGNATURE |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
4 |
Status |
F |
Date |
2021-06-29 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-06-29 |
Time |
16:29 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-06-29 |
Time |
16:26 |
Sent To |
|
|
| Notes |
| 2021-06-29 16:29:02 | THE FOLLOWING SHEETS DO NOT HAVE THE DIGITAL | | | SIGNATURES: M1.0, E2.0. E2.2, E3.0, E4.0 E6.0, E7.0 | | | PLEASE UPLOAD THE DIGITALLY SIGNED DRAWINGS ONF THESE | | | SHEETS. | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
P |
Date |
2021-06-23 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-06-23 |
Time |
08:42 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-06-23 |
Time |
08:42 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
F |
Date |
2021-05-28 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-05-28 |
Time |
15:15 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-05-28 |
Time |
15:15 |
Sent To |
|
|
| Notes |
| 2021-05-28 15:17:23 | THE PLUMBING SHEETS STILL NEED FOR THE DESIGNER TO | | | DIGITALLY SIGN AND SEAL EACH DRAWING. | | | | | | PER THE WPB AMENDMENTS TO THE FBC, EACH SHEET OF PLAN | | | (INCLUDING THE SUPPORTING DOCUMENTS) IS REQUIRED TO BE | | | SIGNED AND SEALED BY THE PERSON RESPONSIBLE FOR THE | | | DESIGN. A DIGITAL PLAN REQUIRES A DIGITAL SIGNATURE | | | WITH THE PROPER THIRD PARTY VERIFICATION. PROVIDE | | | CORRECTION. ALTERNATIVELY, A SIGNED/SEALED PAPER SET | | | MAY BE SUPPLIED TO THE BUILDING DEPARTMENT WHEN ALL | | | TRADES ARE APPROVED. WPB FBC 107.1; FS 471/481 | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | | | 2021-05-27 16:45:54 | ELECTRICAL DIGITAL SIGNATURE OK |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2021-03-29 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-03-29 |
Time |
12:32 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-03-29 |
Time |
11:43 |
Sent To |
|
|
| Notes |
| 2021-03-29 12:33:36 | THE MEP SHEETS MUST HAVE THE DESIGNERS DIGITAL | | | SIGNATURE. | | | | | | PER THE WPB AMENDMENTS TO THE FBC, EACH SHEET OF PLAN | | | (INCLUDING THE SUPPORTING DOCUMENTS) IS REQUIRED TO BE | | | SIGNED AND SEALED BY THE PERSON RESPONSIBLE FOR THE | | | DESIGN. A DIGITAL PLAN REQUIRES A DIGITAL SIGNATURE | | | WITH THE PROPER THIRD PARTY VERIFICATION. PROVIDE | | | CORRECTION. ALTERNATIVELY, A SIGNED/SEALED PAPER SET | | | MAY BE SUPPLIED TO THE BUILDING DEPARTMENT WHEN ALL | | | TRADES ARE APPROVED. WPB FBC 107.1; FS 471/481 | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2021-07-06 |
|
|
Cont ID |
|
| Sent By |
rthermid |
Date |
2021-07-06 |
Time |
|
Rev Time |
0.00 |
| Received By |
rthermid |
Date |
2021-07-06 |
Time |
|
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2021-06-09 |
|
|
Cont ID |
|
| Sent By |
rthermid |
Date |
2021-06-09 |
Time |
|
Rev Time |
0.00 |
| Received By |
rthermid |
Date |
2021-06-09 |
Time |
|
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2021-05-14 |
|
|
Cont ID |
|
| Sent By |
rthermid |
Date |
2021-05-14 |
Time |
|
Rev Time |
|
| Received By |
rthermid |
Date |
2021-05-14 |
Time |
|
Sent To |
I |
|
| Notes |
| 2021-05-14 10:08:07 | ZONING PLAN REVIEW | | | ________________________________________ | | | | | | DATE OF REVIEW: 5/14/2021 | | | ________________________________________ | | | | | | REVIEW STATUS: FAILED | | | ________________________________________ | | | | | | PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN | | | REVIEW COMMENTS: | | | | | | 1. PROVIDE AN UPDATED SURVEY OF THE PROPERTY SHOWING | | | THE EXISTING BUILDING. | | | 2. PER APPROVED PLANS, SEVERAL BUILDING ON THE SAME LOT | | | ARE REQUIRED TO HAVE SEPERATE ADDRESSES, PLEASE GET IN | | | CONTACT WITH THE ADDRESSING COORDINATOR - CAROLINE | | | PUELL - [email protected]. | | | 3. | | | ________________________________________ | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | IF YOU SUBMITTED A PAPER APPLICATION, AND YOU WOULD | | | LIKE TO RESUBMIT ELECTRONICALY, EMAIL | | | [email protected] AND REQUEST TO HAVE YOUR | | | PROJECT CONVERTED TO PROJECTDOX. YOU WILL RECEIVE LOGIN | | | INFORMATION AND A LINK TO UPLOAD YOUR RESUBMITTAL. | | | PLEASE BE SURE TO ?COMPLETE THE UPLOAD TASK? WHEN YOU | | | ARE FINISHED UPLOADING. | | | | | | ________________________________________ | | | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | | | RAFAELA THERMIDOR, ASSOCIATE PLANNER | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | | 401 CLEMATIS STREET - P.O. BOX 3147 | | | WEST PALM BEACH, FLORIDA 33402 | | | | | | TTY: 800.955.8771 | | | E: [email protected] | | | W: WPB.ORG | | | |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |