| Plan Review Stops For Permit 21010986 |
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2021-02-03 |
|
|
Cont ID |
|
| Sent By |
equinone |
Date |
2021-02-03 |
Time |
13:36 |
Rev Time |
0.00 |
| Received By |
equinone |
Date |
2021-02-03 |
Time |
13:36 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
P |
Date |
2021-02-25 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2021-02-25 |
Time |
11:49 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2021-02-25 |
Time |
11:00 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2021-02-02 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2021-02-02 |
Time |
15:56 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2021-02-02 |
Time |
15:12 |
Sent To |
|
|
| Notes |
| 2021-02-02 15:57:04 | 1ST REVIEW FBC-2020 FUEL GAS | | | PERMIT- 21010986 | | | 2/2/2021 | | | | | | CODES IN EFFECT: | | | FBC FG- FLORIDA FUEL GAS CODE 7TH EDITION 2020 | | | FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020 | | | FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020 | | | FBC B- FLORIDA BUILDING CODE 7TH EDITION 2020 | | | FBC M- FLORIDA MECHANICAL CODE 7TH EDITION 2020 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION | | | 2020 | | | FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) PROVIDE A GAS RISER DRAWING IN ACCORDANCE WITH | | | SECTION 107.3.5.1.5 WPB. PROVIDE THE FOLLOWING | | | INFORMATION ON THE RISER PER THE FBC FG: | | | A) TOTAL AND INDIVIDUAL LOADS OF THE SYSTEM- SECTION | | | 402.2 | | | B) TOTAL DEVELOPED LENGTH FROM THE METER TO THE MOST | | | REMOTE OUTLET- 402.4.1. | | | C) DELIVERY PRESSURE AT THE METER- 401.7. | | | D) PIPE SIZING TABLES OR SIZING METHOD USED- 402.3 | | | E) MAIN SUPPLY PIPE SIZE AND BRANCH PIPE POINTS OF | | | CONNECTION- 401.4 & 402.2. THE DETAIL ON SHEET P101 | | | APPEARS TO SHOW THE 1 IN. METALLIC DOAS SUPPLY PIPE | | | CONNECTING TO THE EXISTING 1-1/2 IN. PIPE WHICH IS | | | CURRENTLY SUPPLYING A LOAD OF 2722 CFH. BASED ON TABLE | | | 402.4(5) FBC FG THE 1-1/2 IN PIPE IS UNDERSIZED FOR THE | | | NEW LOAD OF 3322 CFH AT A TOTAL DEVELOPED LENGTH OF 300 | | | FT. | | | | | | 2) PROVIDE A GAS SUB-PERMIT APPLICATION- SECTION 105.1 | | | WPB. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | CCOLE@WPB | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2021-04-15 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2021-04-15 |
Time |
16:16 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2021-04-08 |
Time |
10:34 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2021-03-02 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2021-03-02 |
Time |
14:19 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2021-02-24 |
Time |
12:20 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2021-02-05 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2021-02-05 |
Time |
09:24 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2021-01-27 |
Time |
07:20 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2021-04-09 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-04-09 |
Time |
07:28 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-04-09 |
Time |
07:28 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2021-03-01 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-03-01 |
Time |
07:27 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-03-01 |
Time |
07:27 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2021-01-29 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-01-29 |
Time |
15:19 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-01-29 |
Time |
15:01 |
Sent To |
|
|
| Notes |
| 2021-01-29 15:19:19 | 1ST REVIEW FBC-2020 MECHANICAL | | | PERMIT-21010986 | | | | | | CODES IN EFFECT: | | | | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2020 | | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2020 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | | 2020 | | | FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2020 | | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | | 2020 | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH | | | EDITION 2020 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | | EDITION 2020 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) PLEASE PROVIDE EQUIPMENT SIZING CALCULATIONS FOR | | | THIS DOAS UNIT. FBC EC C403.2.1 | | | | | | 2) SHEET M101: PLEASE INCLUDE KEY NOTES 7 & 8 ON THIS | | | SHEET. FBC 107.2.1 | | | | | | 3) SHEET M201: THERE IS A LOT OF INFORMATION ON THIS | | | SHEET THAT DOES NOT APPLY FOR THE PERMIT APPLIED FOR ON | | | THIS PROJECT. PLEASE REMOVE ALL INFORMATION THAT DOES | | | NOT PERTAIN TO THIS PERMIT. FBC 107.2 | | | | | | 4) SHEET M102: THE DEMO ROOF PLAN AND THE NEW WORK ROOF | | | PLAN DO NOT LINE UP. PLEASE MAKE SURE THE LOCATIONS | | | MATCH. FBC 107.2.1 | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE OLD | | | SHEETS FROM THE PLAN SETS, BIND THEM TOGETHER | | | SEPARATELY AND MARK VOID OR OLD ON THEM. PLEASE RETAIN | | | THEM FOR REFERENCE WITH THE NEW SUBMITTED PLANS. THIS | | | PROCESS WILL ALSO APPLY TO ANY DOCUMENTS SUCH AS | | | PRODUCT APPROVALS OR CALCULATIONS BEING REPLACED OR | | | UPDATED. | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
N |
Date |
2021-02-25 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2021-02-25 |
Time |
11:27 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2021-02-25 |
Time |
11:00 |
Sent To |
|
|
| Notes |
| 2021-02-25 11:28:08 | CONDENSATE PIPING FOR NEW ROOFTOP UNITS TO BE INSTALLED | | | BY MECHANICAL CONTRACTOR. | | | CCOLE- 2/25/21 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2021-02-02 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2021-02-02 |
Time |
16:00 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2021-02-02 |
Time |
14:17 |
Sent To |
|
|
| Notes |
| 2021-02-02 16:00:36 | 1ST REVIEW FBC-2020 PLUMBING | | | PERMIT- 21010986 | | | 2/2/2021 | | | | | | CODES IN EFFECT: | | | FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020 | | | FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020 | | | FBC B- FLORIDA BUILDING CODE 7TH EDITION 2020 | | | FBC M- FLORIDA MECHANICAL CODE 7TH EDITION 2020 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION | | | 2020 | | | FBC FG- FLORIDA FUEL GAS CODE 7TH EDITION 2020 | | | FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | SHEET P001 & P101: PROVIDE THE SLOPE OF THE DOAS | | | CONDENSATE PIPE AND PROVIDE PIPE SUPPORT DETAILS- | | | SECTION 314.2.1 AND TABLE 308.5 FBC P. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
4 |
Status |
P |
Date |
2021-05-07 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-05-07 |
Time |
16:59 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-05-07 |
Time |
16:59 |
Sent To |
|
|
| Notes |
| 2021-05-07 17:02:45 | ORIGINAL SIGNED AND SEALED PAPER DRAWINGS ROUTED TO | | | STORAGE.ME |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
N |
Date |
2021-04-14 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-04-09 |
Time |
07:30 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-04-09 |
Time |
07:28 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2021-02-17 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-02-17 |
Time |
08:55 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-02-17 |
Time |
08:53 |
Sent To |
|
|
| Notes |
| 2021-02-17 08:56:06 | ORIGINAL SIGNED AND SEALED DOUCUMENTS ROUTED TO | | | STORAGE.ME |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2021-01-27 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-01-27 |
Time |
07:10 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-01-27 |
Time |
07:09 |
Sent To |
|
|
| Notes |
| 2021-01-27 07:11:39 | ORIGINAL SIGNED AND SEALED PAPER DRAWINGS ROUTED TO | | | STORAGE.ME |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2021-04-15 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2021-04-15 |
Time |
15:59 |
Rev Time |
0.50 |
| Received By |
eschneid |
Date |
2021-04-15 |
Time |
14:27 |
Sent To |
|
|
| Notes |
| 2021-04-15 16:00:44 | BASED ON INFORMATION PROVIDED, THE NEW MECHANICAL | | | EQUIPMENT SHOULD MEET SCREENING REQUIREMENT. | | | IF IT DOES NOT, THE EQUIPMENT MUST BE PAINTED IN A SKY | | | PATTERN CONSISTENT WITH OTHER ROOFTOP UNITS IN | | | THE PALM BEACH OUTLETS. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2021-03-02 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2021-03-02 |
Time |
13:21 |
Rev Time |
0.50 |
| Received By |
eschneid |
Date |
2021-03-02 |
Time |
11:47 |
Sent To |
|
|
| Notes |
| 2021-03-02 13:28:43 | FAILED | | | | | | REPEAT COMMENT - THE PALM BEACH OUTLETS REQUIRE THAT | | | ROOFTOP MECHANICAL EQUIPMENT MUST BE SCREENED. PROVIDE | | | SIGHTLINE DRAWINGS OR OTHER VERIFICATION THAT THE NEW | | | ROOFTOP EQUIPMENT WILL BE SCREENED FROM THE PROPERTY | | | LINES TO THE EAST AND SOUTH SIDES OF THE BUILDING. | | | | | | THANK YOU FOR PROVIDING PHOTOGRAPHS OF THE ROOF AND THE | | | BUILDING; HOWEVER, NO INFORMATION WAS PROVIDED ON THE | | | HEIGHT OF THE EQUIPMENT TO VERIFY THAT IT IS A LOWER | | | HEIGHT THAN THE EXISTING PARAPET WALLS (WHICH WOULD BE | | | SCREENED). IF THE EQUIPMENT IS TALLER THAN THE PARAPET | | | WALLS, THEN YOU NEED TO PROVIDE EVIDENCE THAT THE | | | LOCATION OF THE EQUIPMENT IN RELATIONSHIP TO THE EDGE | | | OF THE BUILDING AND THE PARAPET WALLS VERIFIES THAT IT | | | WOULD BE SCREENED. PHOTOS CAN SHOW THIS IF YOU HAVE | | | INSTALLED A MOCK UP ON THE ROOF IN THE EXACT LOCATION | | | OF THE NEW EQUIPMENT. THE PHOTOS, NOT EVEN SHOWING | | | WHERE THE NEW EQUIPMENT IS PROPOSED, PROVIDE NO | | | VERIFICATION THAT THE NEW EQUIPMENT WILL COMPLY WITH | | | THE SCREENING REQUIREMENTS. YOU HAVE NOT PROVIDED PROOF | | | THAT THE NEW ROOFTOP EQUIPMENT WILL MEET THE SCREENING | | | REQUIREMENTS. | | | | | | CONTACT ERIC SCHNEIDER @ (561) 822-1446 | | | [email protected] | | | | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2021-02-04 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2021-02-04 |
Time |
11:38 |
Rev Time |
0.25 |
| Received By |
eschneid |
Date |
2021-02-04 |
Time |
11:38 |
Sent To |
|
|
| Notes |
| 2021-02-04 11:43:47 | FAILED | | | | | | THE PALM BEACH OUTLETS REQUIRE THAT ROOFTOP MECHANICAL | | | EQUIPMENT MUST BE SCREENED. PROVIDE SIGHTLINE DRAWINGS | | | OR OTHER VERIFICATION THAT THE NEW ROOFTOP EQUIPMENT | | | WILL BE SCREENED FROM THE PROPERTY LINES TO THE EAST | | | AND SOUTH SIDES OF THE BUILDING. | | | | | | CONTACT ERIC SCHNEIDER @ (561) 822-1446 | | | [email protected] | | | | | | |
|
|