| Plan Review Stops For Permit 21010972 |
| Review Stop |
AD |
ADDRESSING |
| Rev No |
1 |
Status |
P |
Date |
2021-02-11 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2021-02-11 |
Time |
10:05 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2021-02-11 |
Time |
10:05 |
Sent To |
|
|
| Notes |
| 2021-02-11 10:06:12 | REVIEWED UNDER 19091166 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2021-03-02 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2021-03-02 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2021-03-02 |
Time |
12:05 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2021-02-12 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2021-02-12 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2021-02-12 |
Time |
12:56 |
Sent To |
|
|
| Notes |
| 2021-02-12 13:32:50 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | | | | 1) THE SUBMITTED PLANS ARE A COPY OF THE PREVIOSULY | | | APPROVED GENERAL CONSTRUCTION PROJECT AND ARE NOT | | | APPROVED FOR THE HOOD SYSTEM. | | | | | | PLEASE SUBMIT JUST THE HOOD SYSTEM PLAN SHEETS AND | | | REMOVE THE REMIANDER, | | | | | | | | | 1A) THE HOOD SYSTEM DESIGN SHEETS ARE INDICATED AS | | | BEING FROM CAPTIVEAIRE. | | | | | | PLEASE PROVIDE DOCUMENTATION FROM CAPTIVEAIRE THAT YOU | | | ARE AUTHORIZED TO USE THEIR DESIGN DOCUMENTS. | | | | | | | | | 2) THERE ARE NO INDICATIONS OF ROOF PENETRATIONS | | | DESIGNS, TRUSS/CEILING DETAILS, CLEARANCE DIMENSIONS, | | | VOID FILLERS, HANGERS, BRACING, ETC. | | | | | | PLEASE PROVIDE SPECIFIC DETAILS | | | | | | | | | | | | 3) THERE NO SPECIFIC DETAIL SHOWING THAT THE PROPOSED | | | EQUIPMENT FITS UNDER THE PROPOSED HOOD INCLUDING THE | | | TOTAL DIMENSIONS OF ALL THE EQUIPMENT PROPOSED VS THE | | | HOOD, THAT INCLUDES REQUIRED HOOD END OVERLAP. | | | | | | SHEET M104 INDICATES A WOK IN THE MIDDLE AND BROILER ON | | | THE LEFT; HOWEVER, NEITHER IS ON THE EQUIPMENT LIST. | | | | | | PLEASE REVIEW AND PROVIDE SPECIFIC DIMENSION AND | | | DETAIL. | | | | | | | | | | | | 4) THERE IS NO ROOF TOP DETAIL SHOWING ALL EXISTING | | | EQUIPMENT/OPENING & DIMENSIONS IN COMPLIANCE WITH CODE | | | REQUIRMENTS. | | | | | | PLEASE PROVIDE SPECIFIC DETAILS | | | | | | | | | | | | 5) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET | | | REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE | | | ABOVE. | | | | | | | | | 6) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE | | | RE-SUBMITTAL OF THE ABOVE. | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2021-03-15 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-03-15 |
Time |
10:34 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-03-11 |
Time |
16:39 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2021-03-11 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2021-03-11 |
Time |
10:08 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2021-03-11 |
Time |
10:08 |
Sent To |
|
|
| Notes |
| 2021-03-11 10:08:51 | DONE IN ERROR - LEM |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2021-03-02 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-03-02 |
Time |
12:43 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-02-25 |
Time |
13:28 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2021-02-18 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-02-18 |
Time |
09:50 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-02-10 |
Time |
20:02 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2021-03-15 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-03-15 |
Time |
10:33 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-03-15 |
Time |
09:50 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2021-03-02 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-03-02 |
Time |
11:56 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-03-02 |
Time |
09:10 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2021-02-18 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-02-18 |
Time |
09:44 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-02-18 |
Time |
09:44 |
Sent To |
|
|
| Notes |
| 2021-02-18 09:50:27 | PLEASE REMOVE THE PERMIT REVISION AS IT PERTAINS TO THE | | | MECHANICAL SYSTEM IN THIS TENANT SPACE AND HAS NOTHING | | | TO DO WITH THE HOOD. PLEASE REMOVE THE ROSEMARY SQUARE- | | | DRAWING INVENTORY LETTER AS THIS HAS NOTHING TO DO WITH | | | THE HOOD. THIS SHOULD BE A SEPARATE PERMIT AND REVIEW | | | FOR THE HOOD SYSTEMS PLEASE REMOVE ALL SHEETS THAT DO | | | NOT PERTAIN TO THIS HOOD DESIGN. I HAVE SPOKEN TO THE | | | ENGINEER OF RECORD AS TO THE DRAWINGS AND INFORMATION | | | REQUIRED FOR THIS REVIEW. | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
P |
Date |
2021-03-15 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-03-15 |
Time |
10:34 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-03-15 |
Time |
10:34 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
F |
Date |
2021-03-02 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-03-02 |
Time |
12:41 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-03-02 |
Time |
12:41 |
Sent To |
|
|
| Notes |
| 2021-03-02 12:42:47 | ALL DRAWINGS THAT ARE NOT LOCKED WILL NEED TO BE SIGNED | | | AND SEALED BY THE DESIGNER. | | | | | | PER THE WPB AMENDMENTS TO THE FBC, EACH SHEET OF PLAN | | | (INCLUDING THE SUPPORTING DOCUMENTS) IS REQUIRED TO BE | | | SIGNED AND SEALED BY THE PERSON RESPONSIBLE FOR THE | | | DESIGN. A DIGITAL PLAN REQUIRES A DIGITAL SIGNATURE | | | WITH THE PROPER THIRD PARTY VERIFICATION. PROVIDE | | | CORRECTION. ALTERNATIVELY, A SIGNED/SEALED PAPER SET | | | MAY BE SUPPLIED TO THE BUILDING DEPARTMENT WHEN ALL | | | TRADES ARE APPROVED. WPB FBC 107.1; FS 471/481 | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2021-02-18 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-02-18 |
Time |
09:50 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-02-18 |
Time |
09:50 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2021-02-11 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2021-02-11 |
Time |
10:20 |
Rev Time |
0.25 |
| Received By |
eschneid |
Date |
2021-02-11 |
Time |
10:20 |
Sent To |
|
|
| Notes |
|
|