Plan Review Details - Permit 21010972
Plan Review Stops For Permit 21010972
Review Stop AD ADDRESSING
Rev No 1 Status P Date 2021-02-11 Cont ID  
Sent By cpuell Date 2021-02-11 Time 10:05 Rev Time 0.00
Received By cpuell Date 2021-02-11 Time 10:05 Sent To  
Notes
2021-02-11 10:06:12REVIEWED UNDER 19091166

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2021-03-02 Cont ID  
Sent By pleduc Date 2021-03-02 Time   Rev Time 0.00
Received By pleduc Date 2021-03-02 Time 12:05 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2021-02-12 Cont ID  
Sent By pleduc Date 2021-02-12 Time   Rev Time 0.00
Received By pleduc Date 2021-02-12 Time 12:56 Sent To  
Notes
2021-02-12 13:32:50THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE
 MARSHAL, WITH THE FOLLOWING COMMENTS:
  
  
 1) THE SUBMITTED PLANS ARE A COPY OF THE PREVIOSULY
 APPROVED GENERAL CONSTRUCTION PROJECT AND ARE NOT
 APPROVED FOR THE HOOD SYSTEM.
  
 PLEASE SUBMIT JUST THE HOOD SYSTEM PLAN SHEETS AND
 REMOVE THE REMIANDER,
  
  
 1A) THE HOOD SYSTEM DESIGN SHEETS ARE INDICATED AS
 BEING FROM CAPTIVEAIRE.
  
 PLEASE PROVIDE DOCUMENTATION FROM CAPTIVEAIRE THAT YOU
 ARE AUTHORIZED TO USE THEIR DESIGN DOCUMENTS.
  
  
 2) THERE ARE NO INDICATIONS OF ROOF PENETRATIONS
 DESIGNS, TRUSS/CEILING DETAILS, CLEARANCE DIMENSIONS,
 VOID FILLERS, HANGERS, BRACING, ETC.
  
 PLEASE PROVIDE SPECIFIC DETAILS
  
  
  
 3) THERE NO SPECIFIC DETAIL SHOWING THAT THE PROPOSED
 EQUIPMENT FITS UNDER THE PROPOSED HOOD INCLUDING THE
 TOTAL DIMENSIONS OF ALL THE EQUIPMENT PROPOSED VS THE
 HOOD, THAT INCLUDES REQUIRED HOOD END OVERLAP.
  
 SHEET M104 INDICATES A WOK IN THE MIDDLE AND BROILER ON
 THE LEFT; HOWEVER, NEITHER IS ON THE EQUIPMENT LIST.
  
 PLEASE REVIEW AND PROVIDE SPECIFIC DIMENSION AND
 DETAIL.
  
  
  
 4) THERE IS NO ROOF TOP DETAIL SHOWING ALL EXISTING
 EQUIPMENT/OPENING & DIMENSIONS IN COMPLIANCE WITH CODE
 REQUIRMENTS.
  
 PLEASE PROVIDE SPECIFIC DETAILS
  
  
  
 5) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET
 REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE
 ABOVE.
  
  
 6) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE
 RE-SUBMITTAL OF THE ABOVE.
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2021-03-15 Cont ID  
Sent By medwards Date 2021-03-15 Time 10:34 Rev Time 0.00
Received By medwards Date 2021-03-11 Time 16:39 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2021-03-11 Cont ID  
Sent By lmarchan Date 2021-03-11 Time 10:08 Rev Time 0.00
Received By lmarchan Date 2021-03-11 Time 10:08 Sent To  
Notes
2021-03-11 10:08:51DONE IN ERROR - LEM

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2021-03-02 Cont ID  
Sent By medwards Date 2021-03-02 Time 12:43 Rev Time 0.00
Received By medwards Date 2021-02-25 Time 13:28 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2021-02-18 Cont ID  
Sent By medwards Date 2021-02-18 Time 09:50 Rev Time 0.00
Received By medwards Date 2021-02-10 Time 20:02 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2021-03-15 Cont ID  
Sent By medwards Date 2021-03-15 Time 10:33 Rev Time 0.00
Received By medwards Date 2021-03-15 Time 09:50 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2021-03-02 Cont ID  
Sent By medwards Date 2021-03-02 Time 11:56 Rev Time 0.00
Received By medwards Date 2021-03-02 Time 09:10 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2021-02-18 Cont ID  
Sent By medwards Date 2021-02-18 Time 09:44 Rev Time 0.00
Received By medwards Date 2021-02-18 Time 09:44 Sent To  
Notes
2021-02-18 09:50:27PLEASE REMOVE THE PERMIT REVISION AS IT PERTAINS TO THE
 MECHANICAL SYSTEM IN THIS TENANT SPACE AND HAS NOTHING
 TO DO WITH THE HOOD. PLEASE REMOVE THE ROSEMARY SQUARE-
 DRAWING INVENTORY LETTER AS THIS HAS NOTHING TO DO WITH
 THE HOOD. THIS SHOULD BE A SEPARATE PERMIT AND REVIEW
 FOR THE HOOD SYSTEMS PLEASE REMOVE ALL SHEETS THAT DO
 NOT PERTAIN TO THIS HOOD DESIGN. I HAVE SPOKEN TO THE
 ENGINEER OF RECORD AS TO THE DRAWINGS AND INFORMATION
 REQUIRED FOR THIS REVIEW.
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status P Date 2021-03-15 Cont ID  
Sent By medwards Date 2021-03-15 Time 10:34 Rev Time 0.00
Received By medwards Date 2021-03-15 Time 10:34 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status F Date 2021-03-02 Cont ID  
Sent By medwards Date 2021-03-02 Time 12:41 Rev Time 0.00
Received By medwards Date 2021-03-02 Time 12:41 Sent To  
Notes
2021-03-02 12:42:47ALL DRAWINGS THAT ARE NOT LOCKED WILL NEED TO BE SIGNED
 AND SEALED BY THE DESIGNER.
  
 PER THE WPB AMENDMENTS TO THE FBC, EACH SHEET OF PLAN
 (INCLUDING THE SUPPORTING DOCUMENTS) IS REQUIRED TO BE
 SIGNED AND SEALED BY THE PERSON RESPONSIBLE FOR THE
 DESIGN. A DIGITAL PLAN REQUIRES A DIGITAL SIGNATURE
 WITH THE PROPER THIRD PARTY VERIFICATION. PROVIDE
 CORRECTION. ALTERNATIVELY, A SIGNED/SEALED PAPER SET
 MAY BE SUPPLIED TO THE BUILDING DEPARTMENT WHEN ALL
 TRADES ARE APPROVED. WPB FBC 107.1; FS 471/481
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2021-02-18 Cont ID  
Sent By medwards Date 2021-02-18 Time 09:50 Rev Time 0.00
Received By medwards Date 2021-02-18 Time 09:50 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2021-02-11 Cont ID  
Sent By eschneid Date 2021-02-11 Time 10:20 Rev Time 0.25
Received By eschneid Date 2021-02-11 Time 10:20 Sent To  
Notes
***NONE***