| Plan Review Stops For Permit 21010935 |
| Review Stop |
AD |
ADDRESSING |
| Rev No |
1 |
Status |
P |
Date |
2021-01-26 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2021-01-26 |
Time |
09:46 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2021-01-26 |
Time |
09:46 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2021-06-21 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-06-21 |
Time |
09:47 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-06-21 |
Time |
09:47 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2021-05-17 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-05-17 |
Time |
09:44 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-05-14 |
Time |
14:07 |
Sent To |
|
|
| Notes |
| 2021-05-17 09:48:14 | NEW SFR | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected] | | | CODE USED FOR REVIEW - 2017 FBC WITH WPB CHAPTER 1 | | | AMENDMENTS | | | | | | CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107 | | | 1) PRODUCT APPROVAL PROVIDED FOR THE ROOF COATING HAS | | | EXPIRED - PLEASE PROVIDE THE UPDATED VERSION (FL1472 | | | R10) | | | 2) PLEASE PROVIDE THE COMPLETE FLORIDA STATE PRODUCT | | | APPROVAL FOR THE EXTERIOR WINDOW AS LISTED ON THE | | | DRAWINGS.THE EVALUATION REPORT PROVIDED IS FOR SMALL | | | MISSLE IMPACT WINDOWS - LARGE MISSLE IMPACT IS | | | REQUIRED. | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2021-02-23 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-02-23 |
Time |
13:18 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-02-23 |
Time |
10:06 |
Sent To |
|
|
| Notes |
| 2021-02-23 13:18:27 | NEW SFR | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected] | | | CODE USED FOR REVIEW - 2017 FBC WITH WPB CHAPTER 1 | | | AMENDMENTS | | | | | | CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107 | | | 1) PLEASE SHOW THE LOCATION OF THE SMOKE ALARMS PER FBC | | | R314.3 | | | 2) CODE IN EFFECT CHANGED ON 1/1/2021 - PLEASE REVISE | | | THE DRAWINGS TO REFLECT THE DESIGN PER THE CODE IN | | | EFFECT ( 2020 FBC AND ASCE 7-16) | | | 3) WIND SPEED SHOWN FOR DESIGN SHOULD BE 170MPH PER FBC | | | WPB AMENDMENTS SECTION 120 FOR RISK CATEGORY II. | | | 4) PLEASE PROVIDE THE COMPLETE FLORIDA STATE PRODUCT | | | APPROVAL FOR THE EXTERIOR WINDOW AND DOORS AS LISTED ON | | | THE DRAWINGS. | | | 5) PLEASE SHOW THE LOCATIONS FOR THE BUILDING TO | | | FOUNDATION ANCHORING BASE PLATES. | | | 6) PLEASE PROVIDE THE DRAWINGS FOR THE EXTERIOR | | | ALUMINUM ENCLOSURES. | | | 7) PLEASE SHOW THE SLOPE OF THE DRIVEWAY TO DRAIN | | | WITHIN THE PROPERTY LINES. | | | 8) WINDOW FRAMING SHOWN - THE WIDTH OF THE FRAMING OR | | | BUCK NEED TO BE AS WIDE AS THE WINDOW FRAME FBC | | | R609.7.2.1 UNLESS OTHERWISE TESTED, BUCKS SHALL EXTEND | | | BEYOND THE INTERIOR FACE OF THE WINDOW OR DOOR FRAME | | | SUCH THAT FULL SUPPORT OF THE FRAME IS PROVIDED. | | | 9) ALUMINUM PORCH ENCLOSURE DETAILS AND WINDOW AND DOOR | | | PRODUCT APPROVALS MAY BE DEFERRED SUBMITTALS BY LISTING | | | ITEMS TO BE DEFERRED ON THE CONSTRUCTION DOCUMENTS - | | | 107.3.4.1 DEFERRED SUBMITTALS. FOR THE PURPOSES OF THIS | | | SECTION, DEFERRED SUBMITTALS ARE DEFINED AS THOSE | | | PORTIONS OF THE DESIGN THAT ARE NOT SUBMITTED AT THE | | | TIME OF THE APPLICATION AND THAT ARE TO BE SUBMITTED TO | | | THE BUILDING OFFICIAL WITHIN A SPECIFIED PERIOD. | | | DEFERRAL OF ANY SUBMITTAL ITEMS SHALL HAVE THE PRIOR | | | APPROVAL OF THE BUILDING OFFICIAL. THE REGISTERED | | | DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE SHALL LIST | | | THE DEFERRED SUBMITTALS ON THE CONSTRUCTION DOCUMENTS | | | FOR REVIEW BY THE BUILDING OFFICIAL. DOCUMENTS FOR | | | DEFERRED SUBMITTAL ITEMS SHALL BE SUBMITTED TO THE | | | REGISTERED DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE | | | WHO SHALL REVIEW THEM AND FORWARD THEM TO THE BUILDING | | | OFFICIAL WITH A NOTATION INDICATING THAT THE DEFERRED | | | SUBMITTAL DOCUMENTS HAVE BEEN REVIEWED AND FOUND TO BE | | | IN GENERAL CONFORMANCE TO THE DESIGN OF THE BUILDING. | | | THE DEFERRED SUBMITTAL ITEMS SHALL NOT BE INSTALLED | | | UNTIL THE DEFERRED SUBMITTAL DOCUMENTS HAVE BEEN | | | APPROVED BY THE BUILDING OFFICIAL. | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2021-05-30 |
|
|
Cont ID |
|
| Sent By |
fgiaquin |
Date |
2021-05-30 |
Time |
22:15 |
Rev Time |
0.00 |
| Received By |
fgiaquin |
Date |
2021-05-30 |
Time |
21:17 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2021-05-12 |
|
|
Cont ID |
|
| Sent By |
fgiaquin |
Date |
2021-05-12 |
Time |
21:50 |
Rev Time |
0.00 |
| Received By |
fgiaquin |
Date |
2021-05-12 |
Time |
19:44 |
Sent To |
|
|
| Notes |
| 2021-05-12 21:50:00 | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | PREVIOUS COMMENTS | | | | | | | | | | | | 1. LOAD CALCULATION SHOWN DOES NOT APPEAR TO FOLLOW THE | | | STANDARD OR OPTIONAL CALCULATION IN NEC 220.40 NEC | | | 220.82 | | | | | | SMALL APPLIANCE CIRCUITS ARE TO BE MINIMUM 1500VA EACH | | | IN LOAD CALC PER NEC 220.52 | | | | | | ALL FIXED APPLIANCES AND HEAT OR AC (WHICHEVER IS | | | GREATER) ALSO NOT SHOWN. | | | | | | 4/0 AWG CU SHOWN FROM MAIN BREAKER PANEL TO MAIN LUG | | | PANEL INSIDE. THIS IS NOT A CODE VIOLATION BUT #4 AWG | | | COPPER SHOWN FOR SERVICE ENTRANCE CONDUCTORS. PERHAPS A | | | TYPO?? | | | | | | 2. *** SATISFIED*** | | | | | | 3. SEVERAL CIRCUITS ARE STILL SHOWN WITHOUT AFCI | | | PROTECTION REQUIRED PER NEC 210.12.. PLEASE PROVIDE | | | CORRECTION. | | | | | | 4. SATISFIED | | | | | | 5. SATISFIED | | | | | | 6. SATISFIED | | | | | | 7. SATISFIED | | | | | | 8. SATISFIED | | | | | | | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | CODES IN EFFECT: | | | | | | HTTP://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/B | | | UILDING-PERMIT-FORMS | | | | | | FBC = FLORIDA BUILDING CODE 2020 7TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE 2020 7TH ED. | | | FBC EB = FLORIDA BUILDING CODE EXISTING BUILDING 2020 | | | 7TH EDITION | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 | | | 7TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2020 7TH EDITION | | | NEC = NFPA 70 2017 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | V/R, | | | | | | FRANK GIAQUINTO III | | | ELECTRICAL INSPECTOR | | | ELECTRICAL PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | [email protected] | | | CELL: 561-657-1653 | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2021-02-06 |
|
|
Cont ID |
|
| Sent By |
fgiaquin |
Date |
2021-02-06 |
Time |
20:43 |
Rev Time |
0.00 |
| Received By |
fgiaquin |
Date |
2021-02-06 |
Time |
19:41 |
Sent To |
|
|
| Notes |
| 2021-02-06 20:41:18 | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. PROVIDE LOAD CALCULATION AND ONE-LINE DIAGRAM OF | | | SERVICE. FBC 107.2.1 NEC 220 | | | | | | 2. SEVERAL RECEPATCLE WALL SPACING VIIOLATIONS | | | THROUGHOUT HOUSE, PROVIDE CORRECTIONS; NEC210.52 | | | | | | 3. AFCI PROTECTION REQUIRED PER NEC210.12F | | | | | | 4. SHOW SMOKE/CARBON ALARMS AS REQUIRED PER FBC-RE 314 | | | &315 | | | | | | 5. RECEPTACLE REQUIRED OUTSIDE FRONT AND REAR OF HOME | | | NEC210.52E | | | | | | 6. PROVIDE PANEL SCHEDULE NEC 220 FBC 107.2.1 | | | | | | 7. NO WATER HEATER SHOWN? FBC 107.2.1 | | | | | | 8. NO WIRING SHOWN FOR A/C CONDENSOR AND AIR HANDLER?? | | | FBC 107.2.1 | | | | | | | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | CODES IN EFFECT: | | | | | | HTTP://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/B | | | UILDING-PERMIT-FORMS | | | | | | FBC = FLORIDA BUILDING CODE 2020 7TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE 2020 7TH ED. | | | FBC EB = FLORIDA BUILDING CODE EXISTING BUILDING 2020 | | | 7TH EDITION | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 | | | 7TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2020 7TH EDITION | | | NEC = NFPA 70 2017 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | V/R, | | | | | | FRANK GIAQUINTO III | | | ELECTRICAL INSPECTOR | | | ELECTRICAL PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | [email protected] | | | CELL: 561-657-1653 | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2021-06-21 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-06-21 |
Time |
09:52 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-05-27 |
Time |
10:06 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2021-05-17 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-05-17 |
Time |
09:48 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-04-29 |
Time |
12:21 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2021-04-08 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2021-04-08 |
Time |
08:02 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2021-01-25 |
Time |
06:53 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
P |
Date |
2021-08-02 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2021-08-02 |
Time |
09:59 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2021-06-21 |
Time |
11:23 |
Sent To |
|
|
| Notes |
| 2021-08-02 10:00:21 | RECEIPT MU-2021-032490 - $0.00 DUE | | 2021-06-21 11:23:44 | 6/21/21 EMAILED IMPACT OFFICE FOR REVIEW. LEM |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2021-02-23 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-02-23 |
Time |
13:19 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-02-23 |
Time |
13:19 |
Sent To |
|
|
| Notes |
| 2021-02-23 13:20:13 | PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE | | | DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS | | | OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST | | | FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE | | | OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL | | | IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME | | | THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM | | | CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS | | | TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF | | | | | | UPON APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE | | | RECEIPT TO YOUR PROJECT OR EMAIL IT TO | | | [email protected] . | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2021-05-05 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-05-05 |
Time |
17:10 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-05-05 |
Time |
06:43 |
Sent To |
|
|
| Notes |
| 2021-05-05 17:11:41 | APPROVED WITH PRIVISO: | | | THE MASTER BEDROOM MUST PROVIDE A RETURN AIR PATH BACK | | | TO THE AHU. FBC RES M1602.3 | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2021-02-02 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-02-02 |
Time |
13:57 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-02-02 |
Time |
13:57 |
Sent To |
|
|
| Notes |
| 2021-02-02 13:57:34 | 1ST REVIEW FBC-2020 MECHANICAL | | | PERMIT-21010935 | | | | | | CODES IN EFFECT: | | | | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2020 | | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2020 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | | 2020 | | | FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2020 | | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | | 2020 | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH | | | EDITION 2020 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | | EDITION 2020 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) PLEASE SHOW CFM?S AT THE GRILLES TO THE BEDROOMS. | | | FBC 107.2.1 | | | | | | 2) PLEASE SHOW THE RETURN AIR PATH FROM BEDROOMS TO THE | | | AHU. FBC RES M1602.3 | | | | | | 3) PLEASE SHOW THE MINIMUM REQUIRED BATH EXHAUST FOR | | | EACH BATHROOM. FBC RES TABLE M1507.4 | | | | | | 4) PLEASE SHOW THE REQUIRED KITCHEN EXHAUST. FBC RES | | | TABLE M1507.4 | | | | | | 5) PLEASE SHOW THE REQUIRED MAKE UP AIR FOR THE DRYER. | | | FBC M 504.6 | | | | | | 6) PLEASE EXPLAIN THE PURPOSE OF THE ERV IN THIS | | | DESIGN. IT APPEARS THAT IN THE SOUTHERN FLORIDA CLIMATE | | | THAT THIS SYSTEM WILL NOT WORK A LOT OF THE TIME OR | | | THAT YOU WOULD BE DUMPING HOT HUMID OUTDOOR AIR INTO | | | THE KITCHEN. THIS COULD MAKE THE AHU-1 WORK HARDER TO | | | REMOVE THE HUMIDITY. | | | | | | 7) PLEASE PROVIDE DETAIL MOUNTING OF THE CONDENSING | | | UNIT. FBC RES M1307.2 | | | | | | 8) PLEASE SHOW THE CONDENSATION ROUTING DETAILS ALONG | | | WITH THE AUXILIARY AND SECONDARY DRAIN SYSTEMS. FBC RES | | | M1411.3 | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE OLD | | | SHEETS FROM THE PLAN SETS, BIND THEM TOGETHER | | | SEPARATELY AND MARK VOID OR OLD ON THEM. PLEASE RETAIN | | | THEM FOR REFERENCE WITH THE NEW SUBMITTED PLANS. THIS | | | PROCESS WILL ALSO APPLY TO ANY DOCUMENTS SUCH AS | | | PRODUCT APPROVALS OR CALCULATIONS BEING REPLACED OR | | | UPDATED. | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2021-06-12 |
|
|
Cont ID |
|
| Sent By |
abelisle |
Date |
2021-06-12 |
Time |
10:35 |
Rev Time |
0.00 |
| Received By |
abelisle |
Date |
2021-06-12 |
Time |
09:54 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2021-05-06 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2021-05-06 |
Time |
13:10 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2021-05-06 |
Time |
13:01 |
Sent To |
|
|
| Notes |
| 2021-05-06 13:10:57 | 05/06/21 REVIEWED FOR CODE COMPLIANCE (PLUMBING) | | | | | | BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE | | | COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN | | | PROFESSIONAL, CONTRACTORS, OR THEIR REPRESENTATIVES | | | FROM THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL, | | | STATE, AND NATIONAL CODES AND STANDARDS IN EFFECT AT | | | THE TIME OF PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK | | | OF EVERY ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM | | | REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES | | | / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO | | | AVOID VOIDING OF THE PERMIT. | | | | | | LUIS A. CRESPO | | | PLUMBING PLAN EXAMINER / INSPECTOR | | | EMAIL: [email protected] OFFICE: 561 805-6720 | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2021-02-02 |
|
|
Cont ID |
|
| Sent By |
abelisle |
Date |
2021-02-02 |
Time |
20:18 |
Rev Time |
0.00 |
| Received By |
abelisle |
Date |
2021-02-02 |
Time |
20:10 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
N |
Date |
2021-02-23 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-02-23 |
Time |
13:18 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-02-23 |
Time |
13:18 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
P |
Date |
2021-06-21 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-06-21 |
Time |
09:51 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-06-21 |
Time |
09:51 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2021-05-05 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-05-05 |
Time |
17:14 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-05-05 |
Time |
17:14 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2021-02-02 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-02-02 |
Time |
14:12 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-02-02 |
Time |
14:12 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2021-06-08 |
|
|
Cont ID |
|
| Sent By |
awooten |
Date |
2021-06-08 |
Time |
|
Rev Time |
0.00 |
| Received By |
awooten |
Date |
2021-06-08 |
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2021-05-07 |
|
|
Cont ID |
|
| Sent By |
awooten |
Date |
2021-05-07 |
Time |
|
Rev Time |
0.00 |
| Received By |
awooten |
Date |
2021-05-07 |
Time |
|
Sent To |
|
|
| Notes |
| 2021-05-07 10:17:47 | *********ZONING NOTE******************* | | | | | | THIS HOME HAS A VARIANCE APPROVAL THROUGH ZBA CASE | | | #3377. | | | | | | ALANA WOOTEN | | | PLANNER | | | PLANNING DIVISION | | | 561-822-1449 | | | [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2021-04-07 |
|
|
Cont ID |
|
| Sent By |
awooten |
Date |
2021-04-07 |
Time |
|
Rev Time |
|
| Received By |
awooten |
Date |
2021-04-07 |
Time |
|
Sent To |
|
|
| Notes |
| 2021-04-07 10:05:48 | ZONING REVIEW FAILED | | | | | | THE REQUIRED FRONT SETBACK IS 25 FEET IN THE MF-14 | | | ZONING DISTRICT. | | | | | | DRIVEWAYS, FENCES, POOLS, ROOFS, MECHANICAL EQUIPMENT, | | | AND GENERATORS REQUIRE A SEPARATE PERMIT. | | | | | | ALANA WOOTEN | | | PLANNER | | | 561-822-1449 | | | [email protected] |
|
|