Plan Review Details - Permit 21010904
Plan Review Stops For Permit 21010904
Review Stop AD ADDRESSING
Rev No 2 Status P Date 2021-03-08 Cont ID  
Sent By cpuell Date 2021-03-08 Time 14:46 Rev Time 0.00
Received By cpuell Date 2021-03-08 Time 14:46 Sent To  
Notes
2021-03-08 14:46:53506 1/2 46TH ST CHANGED TO 508 46TH ST

Review Stop AD ADDRESSING
Rev No 1 Status F Date 2021-02-03 Cont ID  
Sent By cpuell Date 2021-02-03 Time 13:00 Rev Time 0.00
Received By cpuell Date 2021-02-03 Time 13:00 Sent To  
Notes
2021-02-03 13:01:11HALF ADDRESSES ARE NO LONGER ALLOWED IN THE CITY,
 PLEASE CONTACT [email protected] TO DISCUSS ADDRESSES
 OPTIONS.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2021-04-13 Cont ID  
Sent By rmcphers Date 2021-04-13 Time 15:40 Rev Time 0.00
Received By rmcphers Date 2021-04-13 Time 15:40 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2021-02-24 Cont ID  
Sent By rmcphers Date 2021-02-24 Time 09:57 Rev Time 0.00
Received By rmcphers Date 2021-02-24 Time 09:18 Sent To  
Notes
2021-02-24 09:54:46REMODEL GUEST COTTAGE
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected]
 CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1
 AMENDMENTS
  
 CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107
 1) SIDING IS SUBJECT TO WIND LOADS - PLEASE SHOW SIDING
 ATTACHMENT TYPE, SIZE AND AMOUNT OR PROVIDE A MIAMI
 DADE OR FLORIDA STATE PRODUCT APPROVAL FOR THE SIDING
 REVIEWED AND MARKED APPROVED BY THE BUILDING DESIGNER.
 FBC NEW SFR R703.1.2WIND RESISTANCE.
 WALL COVERINGS, BACKING MATERIALS AND THEIR ATTACHMENTS
 SHALL BE CAPABLE OF RESISTING WIND LOADS IN ACCORDANCE
 WITH TABLES R301.2(2) AND R301.2(3) FOR WALLS USING AN
 EFFECTIVE WIND AREA OF 10 SQUARE FEET. WIND-PRESSURE
 RESISTANCE OF THE SIDING AND BACKING MATERIALS SHALL BE
 DETERMINED BY ASTM E330 OR OTHER APPLICABLE STANDARD
 TEST METHODS. WHERE WIND-PRESSURE RESISTANCE IS
 DETERMINED BY DESIGN ANALYSIS, DATA FROM APPROVED
 DESIGN STANDARDS AND ANALYSIS CONFORMING TO GENERALLY
 ACCEPTED ENGINEERING PRACTICE SHALL BE USED TO EVALUATE
 THE SIDING AND BACKING MATERIAL AND ITS FASTENING. ALL
 APPLICABLE FAILURE MODES INCLUDING BENDING RUPTURE OF
 SIDING, FASTENER WITHDRAWAL AND FASTENER HEAD
 PULL-THROUGH SHALL BE CONSIDERED IN THE TESTING OR
 DESIGN ANALYSIS. WHERE THE WALL COVERING AND THE
 BACKING MATERIAL RESIST WIND LOAD AS AN ASSEMBLY, USE
 OF THE DESIGN CAPACITY OF THE ASSEMBLY SHALL BE
 PERMITTED.
 2) PLEASE SHOW THE CEILING HEIGHT FBC R305
  
  
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2021-02-10 Cont ID  
Sent By fgiaquin Date 2021-02-10 Time 21:47 Rev Time 0.00
Received By fgiaquin Date 2021-02-10 Time 20:50 Sent To  
Notes
***NONE***

Review Stop HIST HISTORICAL
Rev No 2 Status P Date 2021-04-23 Cont ID  
Sent By fmittner Date 2021-04-23 Time 10:56 Rev Time 0.00
Received By fmittner Date 2021-04-23 Time 10:56 Sent To  
Notes
***NONE***

Review Stop HIST HISTORICAL
Rev No 1 Status F Date 2021-03-12 Cont ID  
Sent By fmittner Date 2021-03-12 Time 16:34 Rev Time 0.00
Received By fmittner Date 2021-03-12 Time 16:34 Sent To  
Notes
2021-03-12 16:37:28HPB HEARD CASE 17-55, HARDI BOARD NOT PERMITTED AS
 FINISH. WOOD SIDING TO BE RESTORED AND REPLACED IN
 AREAS NECESSARY WITH WOOD SIDING.
  
 QUESTIONS, CONTACT:
 FRIEDERIKE MITTNER, CITY HSITORIC PRESERVATION PLANNER
 AT (561) 822-1457 OR [email protected]

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2021-04-27 Cont ID  
Sent By lmarchan Date 2021-04-27 Time 14:04 Rev Time 0.00
Received By lmarchan Date 2021-04-08 Time 13:23 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2021-03-12 Cont ID  
Sent By lmarchan Date 2021-03-12 Time 16:43 Rev Time 0.00
Received By lmarchan Date 2021-01-28 Time 10:18 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status P Date 2021-05-18 Cont ID  
Sent By lmarchan Date 2021-05-18 Time 08:00 Rev Time 0.00
Received By lmarchan Date 2021-04-29 Time 13:56 Sent To  
Notes
2021-05-11 10:59:30RECEIPT MU-2021-22460 - $1945.04 - PAID
  
2021-04-29 13:56:324/29/21 EMAILED IMPACT OFFICE FOR REVIEW. LEM

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2021-02-24 Cont ID  
Sent By rmcphers Date 2021-02-24 Time 09:58 Rev Time 0.00
Received By rmcphers Date 2021-02-24 Time 09:58 Sent To  
Notes
2021-02-24 09:58:53PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE
 DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS
 OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST
 FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE
 OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL
 IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME
 THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM
 CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS
 TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF
  
 UPON APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE
 RECEIPT TO YOUR PROJECT OR EMAIL IT TO
 [email protected] .
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2021-02-08 Cont ID  
Sent By medwards Date 2021-02-08 Time 07:21 Rev Time 0.00
Received By medwards Date 2021-02-08 Time 07:09 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2021-04-20 Cont ID  
Sent By ccole Date 2021-04-20 Time 15:49 Rev Time 0.00
Received By ccole Date 2021-04-20 Time 14:50 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2021-02-10 Cont ID  
Sent By ccole Date 2021-02-10 Time 12:44 Rev Time 0.00
Received By ccole Date 2021-02-10 Time 11:17 Sent To  
Notes
2021-02-10 12:45:021ST REVIEW FBC-2020 RES.
 PERMIT- 21010904
 2/10/2021
  
 CODES IN EFFECT:
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION
 2020
 FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020
 FBC B- FLORIDA BUILDING CODE 7TH EDITION 2020
 FBC M- FLORIDA MECHANICAL CODE 7TH EDITION 2020
 FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION
 2020
 FBC FG- FLORIDA FUEL GAS CODE 7TH EDITION 2020
 FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SHEET P1: THE SANITARY RISER SHOWS A NON-COMPLIANT
 BATHROOM WET VENT- SECTION P3108.2.1 FBC RES- NOT MORE
 THAN ONE WET-VENTED FIXTURE DRAIN SHALL DISCHARGE
 UPSTREAM OF THE DRY VENTED FIXTURE DRAIN CONNECTION.
 THE RISER SHOWS THE SHOWER AND THE WATER CLOSET BOTH
 DISCHARGING UPSTREAM.
  
 2) P1: A CLEANOUT IS REQUIRED AT THE JUNCTION OF THE
 BATHROOM BUILDING DRAIN AND THE BUILDING SEWER- SECTION
 P3005.2.3 FBC P.
  
 3) P1: THE PLUMBING FIXTURE NOTES- C, D, E INDICATE
 BOTH AN EXISTING TUB AND AN EXISTING SHOWER- PLEASE
 CLARIFY- SECTION 107.2.1 WPB.
  
 4) P1: REMOVE ALL FIXTURES FROM THE SCHEDULE THAT ARE
 NOT BEING USED IN THE PROPOSED PROJECT- SECTION 107.2.1
 WPB.
  
 5) P1: IF APPLICABLE, SHOW THE WATER SUPPLY LINE TO THE
 REFRIGERATOR ICE MAKER INCLUDING THE REQUIRED BACKFLOW
 PREVENTER AND WATER HAMMER ARRESTOR- SECTIONS P2902.1 &
 P2903.5 FBC RES.
  
 6) P1: PROVIDE A SHOWER PAN LINER DETAIL- SECTION
 P2709.1 & P2709.2 FBC RES.
  
 7) P1: PLEASE NOTE THAT SEPARATE RESIDENCES ON THE SAME
 PROPERTY MAY REQUIRE INSTALLATION OF A BACKFLOW
 PREVENTER AT THE WATER METER. PLEASE CONTACT THE WPB
 UTILITIES CENTRAL OPERATIONS DEPT.AT 561-822-2210 FOR
 FURTHER INFORMATION.
  
 PLEASE NOTE THAT A FL. LICENSED PLUMBING CONTRACTOR
 SHALL OBTAIN A SEPARATE PERMIT FOR INSTALLATION OF THE
 BACKFLOW PREVENTER IN ACCORDANCE WITH SECTION 105.1 WPB
 AND SEC. 90-33 WPB CODE OF ORDINANCES. THE DEVICE SHALL
 BE TESTED AND CERTIFIED BY THE WPB UTILITIES DEPARTMENT
 PRIOR TO FINAL INSPECTION BY THE BUILDING DEPARTMENT.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  
  

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status N Date 2021-02-24 Cont ID  
Sent By rmcphers Date 2021-02-24 Time 09:59 Rev Time 0.00
Received By rmcphers Date 2021-02-24 Time 09:59 Sent To  
Notes
2021-02-24 10:00:35PLANS STATE THAT THE ROOF WILL BE A SEPARATE PERMIT

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2021-04-13 Cont ID  
Sent By rmcphers Date 2021-04-13 Time 15:40 Rev Time 0.00
Received By rmcphers Date 2021-04-13 Time 15:40 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2021-02-08 Cont ID  
Sent By medwards Date 2021-02-08 Time 07:25 Rev Time 0.00
Received By medwards Date 2021-02-08 Time 07:22 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2021-03-12 Cont ID  
Sent By fmittner Date 2021-03-12 Time 16:33 Rev Time 0.00
Received By fmittner Date 2021-03-12 Time 16:33 Sent To  
Notes
***NONE***