Plan Review Details - Permit 21010826
Plan Review Stops For Permit 21010826
Review Stop AD ADDRESSING
Rev No 2 Status P Date 2021-02-18 Cont ID  
Sent By cpuell Date 2021-02-18 Time 16:19 Rev Time 0.00
Received By cpuell Date 2021-02-18 Time 16:19 Sent To  
Notes
2021-02-18 16:20:19840 APPROVED AND ADDED TO ALL DATABASES

Review Stop AD ADDRESSING
Rev No 1 Status F Date 2021-01-22 Cont ID  
Sent By cpuell Date 2021-01-22 Time 14:05 Rev Time 0.00
Received By cpuell Date 2021-01-22 Time 14:05 Sent To  
Notes
2021-01-22 14:06:15SUITE 840 NOT A LEGAL SUITE NUMBER AT THIS TIME, PLEASE
 STATE THE PREVIOUS TENANT IN THIS SPACE AND PROVIDE A
 AN ENTIRE FLOOR PLAN SHOWING THE ALL SUITES ON THE
 FLOOR. PLEASE EMAIL [email protected]

Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 2 Status P Date 2021-02-24 Cont ID  
Sent By jwitmer Date 2021-02-24 Time   Rev Time 0.00
Received By jwitmer Date 2021-02-24 Time 08:32 Sent To  
Notes
***NONE***

Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 1 Status F Date 2021-02-03 Cont ID  
Sent By jwitmer Date 2021-02-03 Time 10:45 Rev Time 0.00
Received By jwitmer Date 2021-02-03 Time 09:55 Sent To  
Notes
2021-02-03 10:45:15COMMERCIAL ASBESTOS
  
 TO THE BUILDING CONTRACTOR:
 PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE
 CONTRACTOR, ON LETTERHEAD, STATING THAT THE
 INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM
 COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH
 COUNTY WILL BE FOLLOWED, AND THAT NOTIFICATION WILL BE
 GIVEN TIMELY. ADDITIONAL INFORMATION REGARDING ASBESTOS
 REQUIREMENTS CAN BE FOUND ON THEIR WEBSITE:
  
 HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE
 S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION-
 RENOVATION.HTML
  
 THE CONTRACTOR ACKNOWLEDGEMENT CAN BE SENT VIA EMAIL TO
 [email protected]. THE INFORMATION SHOULD BE IN PDF
 FORMAT AS AN ATTACHMENT TO THE EMAIL. PLEASE INCLUDE
 THE PERMIT NUMBER AND "ASBESTOS" IN THE SUBJECT LINE.
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date   Cont ID  
Sent By   Date 2021-02-24 Time 08:59 Rev Time 0.00
Received By   Date 2021-02-24 Time 08:32 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2021-02-03 Cont ID  
Sent By jwitmer Date 2021-02-03 Time 10:44 Rev Time 0.00
Received By jwitmer Date 2021-02-03 Time 09:55 Sent To  
Notes
2021-02-03 10:44:05WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION
 SERVICES/ BUILDING DIVISION
 2020 FBC- BUILDING PLAN REVIEW
 W. P. B. PERMIT: 21010826
 ADD: 525 OKEECHOBEE BLVD. SUITE # ??? SPEC SUITE 840???
 CONT: HOLT LEE CONSTRUCTION
 TEL: 954-725-4881
 E-MAIL: GLEE@ HOLT-LEE, COM
  
 2020 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2020 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW
 CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES
 SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA
 BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: MON. FEB. 01/2021
 ACTION: DENIED
  
 1) PLEASE REVIEW THE ADDRESSING PLAN REVIEW COMMENT OF
 NEWLY DEVELOPED SUITE NUMBER. PERMIT # 21010826 WAS ONE
 SHELL TENANT SPACE, NOW IT IS SUB-DIVIDED. NEW TENANT
 ADDRESS HAS TO BE APPROVED BY WEST PALM BEACH
 ADDRESSING. 2020 FLORIDA BUILDING CODE W 2017 WEST PALM
 BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER
 1, ADMINISTRATION 107.2.1 INFORMATION ON CONSTRUCTION
 DOCUMENTS. CONSTRUCTION DOCUMENTS SHALL BE OF
 SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE AND
 EXTENT OF THE WORK PROPOSED.
  
 2) COMMENTS FROM PERMIT 21010825 NEED TO BE ADDRESSED,
 THE SUB-DIVIDING OF THE LARGER SPACE STILL NEEDS TO BE
 ADDRESSED. WORK BEING COMPLETED UNDER THIS PERMIT
 21010826) CAN NOT CREATE A NON-CONFORMITY FOR THE WORK
 BEING COMPLETED UNDER THE PERMIT (21010825). OCCUPANT
 LOADS FOR BOTH TENANT SPACES NEED TO BE SHOWN ON THIS
 PERMIT AND TRAVEL DISTANCE FROM THE MOST REMOTE POINT
 IN THE PROPOSED SUITE FOR EACH TENANT.
 FBC-B SECTION 1010.1.2.1 DIRECTION OF SWING. PIVOTING
 OR SIDE HINGED SWING DOOR SHALL SWING IN THE DIRECTION
 OF EGRESS TRAVEL WHERE SERVING A ROOM OR AREA
 CONTAINING AN OCCUPANT LOAD OF 50 OR MORE PERSONS.
  
 3) THE COVERSHEET LIST THE SQUARE FOOTAGE FOR THIS
 TENANT SPACE AS 3,064 SQ. FT./ AND 30 OCCUPANTS. PLEASE
 REVIEW CHANGES TO THE 2020 FBC-B OCCUPANT LOAD FACTOR
 FOR BUSINESS OCCUPANCIES, SEE TABLE 1004.5. THE NEW
 OCCUPANT LOAD FACTOR FOR A BUSINESS OCCUPANCY IS 150
 GROSS. 3064/150= 20.4 OR 21 OCCUPANTS. THE FLOOR PLAN
 SHOWS 42 SEATS. WITH THE COMMENTS FROM PERMIT 21010825
 BEING ANSWERED, WE DO NOT KNOW IF SPLITTING THE SHELL
 SPACE IN HALF DOES CREATE A NON-CONFORMITY.
  
 4) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 PLEASE NOTE WE ARE WORKING FROM HOME BECAUSE OF COVID
 19
 IF YOU WOULD LIKE TO CONTACT ME, MY CELL NUMBER IS
 561-718-9724.
 WORKING HOURS ARE MON.- WED. 8:00 AM- NOON. PART-TIME/
 RETIRED.
  
 JAMES A. WITMER BN, PX, SFP, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2021-02-26 Cont ID  
Sent By equinone Date 2021-02-26 Time 14:28 Rev Time 0.00
Received By equinone Date 2021-02-26 Time 14:11 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2021-02-09 Cont ID  
Sent By equinone Date 2021-02-09 Time 12:04 Rev Time 0.00
Received By equinone Date 2021-02-08 Time 16:24 Sent To  
Notes
2021-02-09 12:09:04CODES IN EFFECT
 CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2020 7TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2020
 7TH ED, CHAPTER 1.
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020
 7TH EDITION
 FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2020
 7TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2020 7TH EDITION
 NEC = NFPA 70 2017 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
 FAC = FLORIDA ADMINISTRATIVE CODE
  
 ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
  
 1) PLEASE SUBMIT A LAYOUT OF ELECTRICAL ROOM WHERE NEW
 DISTRIBUTION PANEL N IS LOCATED SHOWING NEW AND
 EXISTING PANELS, SWITCHBOARDS, ETC. PLEASE ALSO SHOW
 LOCATION OF THIS ROOM IN THE BUILDING. FBC 107
  
  
 END OF COMMENTS.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES
 INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE
 PREVIOUSLY REVIEWED SHEETS.
 CODES IN EFFECT:
  
 IF THE RESUBMITTAL IS NOT PREPARED BY A DESIGN
 PROFESSIONAL (ARCHITECT OR ENGINEER), AND THE PAGES ARE
 11X17 OR SMALLER, YOU MAY RESUBMIT, ALONG WITH A
 COMPLETED RESUBMITTAL FORM, VIA EMAIL TO
 [email protected]. THE EMAIL SHOULD INCLUDE THE PERMIT
 NUMBER AND "RESUBMITTAL" IN THE SUBJECT LINE. THE
 RESUBMITTAL FORM CAN BE FOUND AT THIS WEBSITE:
  
 HTTP://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/B
 UILDING-PERMIT-FORMS
  
 ENRIQUE QUINONEZ P.E.
 ELECTRICAL PLANS EXAMINER
 561-805-6746
 [email protected]
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2021-03-15 Cont ID  
Sent By pleduc Date 2021-03-15 Time   Rev Time 0.00
Received By pleduc Date 2021-03-15 Time 14:55 Sent To  
Notes
2021-03-15 14:56:13THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC,
 FIRE MARSHAL, WITH THE FOLLOWING COMMENTS:
  
 PLEASE CONSIDER THE FOLLOWING AS PROVISO:
  
 THESE PROVISO COMMENTS WILL BE VERIFIED AND CONFIRMED
 AT THE TIME OF FIRE INSPECTION. FAILURE TO FOLLOW THESE
 PROVISO COMMENTS WILL RESULT IN A FAILED FIRE
 INSPECTION.
  
  
 1) THERE ARE HORIZONTAL SLIDING DOORS INDICATED AT
 NUMEROUS OFFICES.
  
 PER NFPA 101 CH 38 AND 7
  
 38.2.2.2 DOORS.
 38.2.2.2.1 DOORS COMPLYING WITH 7.2.1 SHALL BE
 PERMITTED.
  
 7.2.1.4 SWING AND FORCE TO OPEN.
 7.2.1.4.1* SWINGING-TYPE DOOR ASSEMBLY REQUIREMENT. ANY
 DOOR ASSEMBLY IN A MEANS OF EGRESS SHALL BE OF THE
 SIDE-HINGED OR
 PIVOTED-SWINGING TYPE, AND SHALL BE INSTALLED TO BE
 CAPABLE OF
 SWINGING FROM ANY POSITION TO THE FULL REQUIRED WIDTH
 OF THE
 OPENING IN WHICH IT IS INSTALLED, UNLESS OTHERWISE
 SPECIFIED AS
 FOLLOWS:
  
 (4) HORIZONTAL-SLIDING DOOR ASSEMBLIES SHALL BE
 PERMITTED UNDER
 ANY OF THE FOLLOWING CONDITIONS:
 (A) HORIZONTAL-SLIDING DOOR ASSEMBLIES IN DETENTION AND
 CORRECTIONAL OCCUPANCIES, AS PROVIDED IN CHAPTERS 22
 AND 23, SHALL BE PERMITTED.
 (B) SPECIAL-PURPOSE HORIZONTALLY SLIDING ACCORDION OR
 FOLDING DOOR ASSEMBLIES COMPLYING WITH 7.2.1.14 SHALL
 BE PERMITTED.
 (C) UNLESS PROHIBITED BY CHAPTERS 11 THROUGH 43,
 HORIZONTAL-SLIDING DOOR ASSEMBLIES SERVING A ROOM OR
 AREA WITH AN OCCUPANT LOAD OF FEWER THAN 10 SHALL BE
 PERMITTED, PROVIDED THAT ALL OF THE FOLLOWING CRITERIA
 ARE
 MET:
 I. THE AREA SERVED BY THE DOOR ASSEMBLY HAS NO HIGH
 HAZARD CONTENTS.
 II. THE DOOR ASSEMBLY IS READILY OPERABLE FROM EITHER
 SIDE WITHOUT SPECIAL KNO
 WLEDGE OR EFFORT.
 III. THE FORCE REQUIRED TO OPERATE THE DOOR ASSEMBLY IN
 THE DIRECTION OF DOOR LEAF TRAVEL IS NOT MORE THAN 30
 LBF (133 N) TO SET THE DOOR LEAF IN MOTION AND IS NOT
 MORE THAN 15 LBF (67 N) TO CLOSE THE DOOR ASSEMBLY
 OR OPEN IT TO THE MINIMUM REQUIRED WIDTH.
  
 IV. THE DOOR ASSEMBLY COMPLIES WITH ANY REQUIRED FIRE
 PROTECTION RATING, AND, WHERE RATED, IS SELF-CLOSING
 OR AUTOMATIC-CLOSING BY MEANS OF SMOKE DETECTION
 IN ACCORDANCE WITH 7.2.1.8 AND IS INSTALLED IN
 ACCORDANCE WITH NFPA 80, STANDARD FOR FIRE
 DOORS AND OTHER OPENING PROTECTIVES.
  
 PLEASE REVIEW AND ENSURE COMPLIANCE FOR FIRE INSPECTION
 PURPOSES.
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  
  
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2021-01-29 Cont ID  
Sent By pleduc Date 2021-01-29 Time   Rev Time 0.00
Received By pleduc Date 2021-01-28 Time 14:43 Sent To  
Notes
2021-01-28 14:46:17THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC,
 FIRE MARSHAL, WITH THE FOLLOWING COMMENTS:
  
 PLEASE CONSIDER THE FOLLOWING AS PROVISO:
  
 THESE PROVISO COMMENTS WILL BE VERIFIED AND CONFIRMED
 AT THE TIME OF FIRE INSPECTION. FAILURE TO FOLLOW THESE
 PROVISO COMMENTS WILL RESULT IN A FAILED FIRE
 INSPECTION.
  
  
 1) THERE ARE HORIZONTAL SLIDING DOORS INDICATED AT
 NUMEROUS OFFICES.
  
 PER NFPA 101 CH 38 AND 7
  
 38.2.2.2 DOORS.
 38.2.2.2.1 DOORS COMPLYING WITH 7.2.1 SHALL BE
 PERMITTED.
  
 7.2.1.4 SWING AND FORCE TO OPEN.
 7.2.1.4.1* SWINGING-TYPE DOOR ASSEMBLY REQUIREMENT. ANY
 DOOR ASSEMBLY IN A MEANS OF EGRESS SHALL BE OF THE
 SIDE-HINGED OR
 PIVOTED-SWINGING TYPE, AND SHALL BE INSTALLED TO BE
 CAPABLE OF
 SWINGING FROM ANY POSITION TO THE FULL REQUIRED WIDTH
 OF THE
 OPENING IN WHICH IT IS INSTALLED, UNLESS OTHERWISE
 SPECIFIED AS
 FOLLOWS:
  
 (4) HORIZONTAL-SLIDING DOOR ASSEMBLIES SHALL BE
 PERMITTED UNDER
 ANY OF THE FOLLOWING CONDITIONS:
 (A) HORIZONTAL-SLIDING DOOR ASSEMBLIES IN DETENTION AND
 CORRECTIONAL OCCUPANCIES, AS PROVIDED IN CHAPTERS 22
 AND 23, SHALL BE PERMITTED.
 (B) SPECIAL-PURPOSE HORIZONTALLY SLIDING ACCORDION OR
 FOLDING DOOR ASSEMBLIES COMPLYING WITH 7.2.1.14 SHALL
 BE PERMITTED.
 (C) UNLESS PROHIBITED BY CHAPTERS 11 THROUGH 43,
 HORIZONTAL-SLIDING DOOR ASSEMBLIES SERVING A ROOM OR
 AREA WITH AN OCCUPANT LOAD OF FEWER THAN 10 SHALL BE
 PERMITTED, PROVIDED THAT ALL OF THE FOLLOWING CRITERIA
 ARE
 MET:
 I. THE AREA SERVED BY THE DOOR ASSEMBLY HAS NO HIGH
 HAZARD CONTENTS.
 II. THE DOOR ASSEMBLY IS READILY OPERABLE FROM EITHER
 SIDE WITHOUT SPECIAL KNOWLEDGE OR EFFORT.
 III. THE FORCE REQUIRED TO OPERATE THE DOOR ASSEMBLY IN
 THE DIRECTION OF DOOR LEAF TRAVEL IS NOT MORE THAN 30
 LBF (133 N) TO SET THE DOOR LEAF IN MOTION AND IS NOT
 MORE THAN 15 LBF (67 N) TO CLOSE THE DOOR ASSEMBLY
 OR OPEN IT TO THE MINIMUM REQUIRED WIDTH.
 IV. THE DOOR ASSEMBLY COMPLIES WITH ANY REQUIRED FIRE
 PROTECTION RATING, AND, WHERE RATED, IS SELF-CLOSING
 OR AUTOMATIC-CLOSING BY MEANS OF SMOKE DETECTION
 IN ACCORDANCE WITH 7.2.1.8 AND IS INSTALLED IN
 ACCORDANCE WITH NFPA 80, STANDARD FOR FIRE
 DOORS AND OTHER OPENING PROTECTIVES.
  
 PLEASE REVIEW AND ENSURE COMPLIANCE FOR FIRE INSPECTION
 PURPOSES.
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  
  
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2021-03-25 Cont ID  
Sent By medwards Date 2021-03-25 Time 13:15 Rev Time 0.00
Received By medwards Date 2021-03-12 Time 16:29 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2021-03-05 Cont ID  
Sent By shill Date 2021-03-05 Time 14:48 Rev Time 0.00
Received By shill Date 2021-02-23 Time 18:51 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date   Cont ID  
Sent By   Date 2021-02-09 Time   Rev Time 0.00
Received By ccarvaja Date 2021-01-26 Time 08:56 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2021-03-25 Cont ID  
Sent By medwards Date 2021-03-25 Time 13:14 Rev Time 0.00
Received By medwards Date 2021-03-25 Time 13:01 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2021-03-04 Cont ID  
Sent By medwards Date 2021-03-04 Time 08:54 Rev Time 0.00
Received By medwards Date 2021-03-04 Time 07:09 Sent To  
Notes
2021-03-04 08:55:112ND REVIEW FBC-2020 MECHANICAL
 PERMIT-21010826
  
 CODES IN EFFECT:
  
 FBC B- FLORIDA BUILDING CODE
 FBC M- FLORIDA MECHANICAL CODE
 FBC EC- FLORIDA ENERGY CONSERVATION
 FBC FG- FLORIDA FUEL GAS
 FBC EX- FLORIDA EXISTING BUILDING CODE
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) PLEASE PROVIDE OUTDOOR AIR CALCULATIONS FOR EACH USE
 OF SPACE IN THIS TENANT SPACE. YOU HAVE A RECEPTION
 AREA, OFFICES, BREAKROOM AND CONFERENCE ROOM. EACH
 SPACE WILL NEED DIFFERENT OUTDOOR AIR. YOU CANNOT JUST
 GROUP IT ALL TOGETHER. FBC M 403.3.1.1
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT
 CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE OLD
 SHEETS FROM THE PLAN SETS, BIND THEM TOGETHER
 SEPARATELY AND MARK VOID OR OLD ON THEM. PLEASE RETAIN
 THEM FOR REFERENCE WITH THE NEW SUBMITTED PLANS. THIS
 PROCESS WILL ALSO APPLY TO ANY DOCUMENTS SUCH AS
 PRODUCT APPROVALS OR CALCULATIONS BEING REPLACED OR
 UPDATED.
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2021-02-04 Cont ID  
Sent By medwards Date 2021-02-04 Time 13:11 Rev Time 0.00
Received By medwards Date 2021-02-04 Time 13:11 Sent To  
Notes
2021-02-04 13:13:21PLEASE PROVIDE OUTDOOR AIR CALCULATIONS FOR THE OFFICE
 SPACE AND ALSO FOR THE CONFERENCE ROOM. FBC M 403.3.1.1
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop P PLUMBING
Rev No 2 Status P Date 2021-03-23 Cont ID  
Sent By ccole Date 2021-03-23 Time 12:35 Rev Time 0.00
Received By ccole Date 2021-03-23 Time 10:55 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2021-02-09 Cont ID  
Sent By ccole Date 2021-02-09 Time 12:16 Rev Time 0.00
Received By ccole Date 2021-02-09 Time 10:50 Sent To  
Notes
2021-02-09 12:16:201ST REVIEW FBC-2020 PLUMBING
 PERMIT- 21010826
 2/9/2021
  
 CODES IN EFFECT:
 FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020
 FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020
 FBC B- FLORIDA BUILDING CODE 7TH EDITION 2020
 FBC M- FLORIDA MECHANICAL CODE 7TH EDITION 2020
 FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION
 2020
 FBC FG- FLORIDA FUEL GAS CODE 7TH EDITION 2020
 FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SHEETS P1 & P2: REVIEW FIXTURE SCHEDULE NOTE A ON P2
 AND SHOW THE TMV FOR THE LAVATORY IN THE RISER DRAWING
 ON P1- SECTIONS 419.5 AND 607.1.2 FBC P.
  
 2) P2- INSTA-HOT PIPING DETAIL: A) A DEDICATED FULL
 OPEN SHUT OFF VALVE IS REQUIRED FOR THE WATER HEATER-
 SECTIONS 503.1 & 606.1(8) FBC P. B) SHOW THE TMV VALVE
 LOCATION AND PIPE CONNECTIONS- SECTION 607.1.2 FBC P.
  
 3) P1: SHOW WATER HAMMER ARRESTORS AND BACKFLOW
 PREVENTERS FOR THE WATER SUPPLY PIPES TO THE
 REFRIGERATION AND DISHWASHER- SECTIONS 604.9 & 608.3
 FBC P. BACKFLOW PREVENTION TO THE DISHWASHER CAN BE
 PROVIDED BY AN AIR GAP- SECTION 409.2.
  
 4) A1.1: PROVIDE THE DIMENSIONS OF THE CLEAR FLOOR
 SPACE DIAGRAMS AT THE FIXTURES- SECTIONS 604.3 & 606.2
 FBC ACC.
  
 5) CLARIFY IF THE EXISTING SLAB WILL BE X-RAYED IN
 ORDER TO LOCATE REINFORCING STEEL OR POST STRESSED
 FLOOR TENDONS- SECTION 107.2.1 WPB.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status P Date 2021-03-25 Cont ID  
Sent By medwards Date 2021-03-25 Time 13:15 Rev Time 0.00
Received By medwards Date 2021-03-25 Time 13:14 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2021-03-04 Cont ID  
Sent By medwards Date 2021-03-04 Time 08:58 Rev Time 0.00
Received By medwards Date 2021-03-04 Time 08:55 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2021-02-04 Cont ID  
Sent By medwards Date 2021-02-04 Time 13:18 Rev Time 0.00
Received By medwards Date 2021-02-04 Time 13:18 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status N Date 2021-02-04 Cont ID  
Sent By eschneid Date 2021-02-04 Time 11:29 Rev Time 0.00
Received By eschneid Date 2021-02-04 Time 11:29 Sent To  
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy