Plan Review Details - Permit 21010825
Plan Review Stops For Permit 21010825
Review Stop AD ADDRESSING
Rev No 1 Status P Date 2021-02-04 Cont ID  
Sent By cpuell Date 2021-02-04 Time 10:26 Rev Time 0.00
Received By cpuell Date 2021-02-04 Time 10:26 Sent To  
Notes
2021-02-04 10:27:42WORK TO BE DONE ON THE 8TH FLOOR COMMUNAL CORRIDOR

Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 2 Status P Date   Cont ID  
Sent By   Date 2021-02-24 Time 08:20 Rev Time 0.00
Received By   Date 2021-02-24 Time 08:16 Sent To  
Notes
***NONE***

Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 1 Status F Date 2021-02-01 Cont ID  
Sent By jwitmer Date 2021-02-01 Time 14:44 Rev Time 0.00
Received By jwitmer Date 2021-02-01 Time 14:32 Sent To  
Notes
2021-02-01 14:44:09COMMERCIAL ASBESTOS
  
 TO THE BUILDING CONTRACTOR:
 PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE
 CONTRACTOR, ON LETTERHEAD, STATING: THAT THE
 INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM
 COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH
 COUNTY WILL BE FOLLOWED, AND THAT NOTIFICATION WILL BE
 GIVEN TIMELY. ADDITIONAL INFORMATION REGARDING ASBESTOS
 REQUIREMENTS CAN BE FOUND ON THEIR WEBSITE:
  
 HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE
 S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION-
 RENOVATION.HTML
  
 THE CONTRACTOR ACKNOWLEDGEMENT CAN BE SENT VIA EMAIL TO
 [email protected]. THE INFORMATION SHOULD BE IN PDF
 FORMAT AS AN ATTACHMENT TO THE EMAIL. PLEASE INCLUDE
 THE PERMIT NUMBER AND "ASBESTOS" IN THE SUBJECT LINE.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date   Cont ID  
Sent By   Date 2021-02-24 Time 08:32 Rev Time 0.00
Received By   Date 2021-02-24 Time 08:16 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2021-02-01 Cont ID  
Sent By jwitmer Date 2021-02-01 Time 15:26 Rev Time 0.00
Received By jwitmer Date 2021-02-01 Time 14:32 Sent To  
Notes
2021-02-01 15:18:51WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION
 SERVICES/ BUILDING DIVISION
 2020 FBC- BUILDING PLAN REVIEW
 W. P. B. PERMIT: 21010825
 ADD: 525 OKEECHOBEE BLVD. SUITE # ???
 CONT: HOLT LEE CONSTRUCTION
 TEL: 954-725-4881
 E-MAIL: GLEE@ HOLT-LEE, COM
  
 2020 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2020 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW
 CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES
 SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA
 BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: MON. FEB. 01/2021
 ACTION: DENIED
  
 1) SHEET A0.3 THE DEMOLITION PLAN SHOWS THAT ALREADY ?
 OF THE COMMON CORRIDOR WALL THAT WOULD BE ADJACENT TO A
 TENANT SPACE HAS BEEN REMOVED, EVEN BEFORE WORK UNDER
 THIS PERMIT BEGINS. SHEET A.1.1 THE PROPOSED FLOOR PLAN
 SHOWS A NEW SECTION OF COMMON CORRIDOR TO TENANT SPACE
 WALL BEING BUILT. THE UNKNOWN NEW TENANT SPACE DOES NOT
 HAVE A SUITE NUMBER IDENTIFYING THE NEW TENANT SPACE,
 SEE ADDRESSING STOP FOR NEW TENANT SPACE. 2017 FLORIDA
 BUILDING CODE W 2017 WEST PALM BEACH AMENDMENTS TO THE
 FLORIDA BUILDING CODE, CHAPTER 1, ADMINISTRATION
 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS.
 CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT CLARITY
 TO INDICATE THE LOCATION, NATURE AND EXTENT OF THE WORK
 PROPOSED.
 2020 FBC-B 501.2 ADDRESS IDENTIFICATION. NEW AND
 EXISTING BUILDINGS SHALL BE PROVIDED WITH APPROVED
 ADDRESS IDENTIFICATION.
  
 2) SHEET A0.3 THE DEMOLITION PLAN SHOWS THAT ALREADY ?
 OF THE COMMON CORRIDOR WALL THAT WOULD BE ADJACENT TO A
 TENANT SPACE HAS BEEN REMOVED, EVEN BEFORE WORK UNDER
 THIS PERMIT BEGINS. SHEET A.1.1 THE PROPOSED FLOOR PLAN
 SHOWS A NEW SECTION OF COMMON CORRIDOR TO TENANT SPACE
 WALL BEING BUILT. THE TITLE-PAGE DOES NOT INCLUDE THE
 SQUARE FOOTAGE OF THE NEW TENANT AREA NOR THE OCCUPANT
 LOAD FOR THIS NEW SPACE. 2020 FBC-B TABLE 1004.5 NOTE
 FOR BUSINESS OCCUPANCY THE OCCUPANT LOAD FACTOR HAS
 CHANGED.
  
 3) SHEET A.1.1 SHOWS THE NEW DOUBLE DOORS SWINGING INTO
 THE NEW TENANT SPACE. THE OCCUPANT LOAD WAS NOT
 SUBMITTED FOR THIS REVIEW. THE QUESTION IS THE NEW
 DOUBLE DOOR SWING AND COMPLIANCE WITH THE 2020 FBC-B
 SECTION 1010.1.2.1 DIRECTION OF SWING. PIVOTING OR SIDE
 HINGED SWING DOOR SHALL SWING IN THE DIRECTION OF
 EGRESS TRAVEL WHERE SERVING A ROOM OR AREA CONTAINING
 AN OCCUPANT LOAD OF 50 OR MORE PERSONS.
  
 4) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 PLEASE NOTE WE ARE WORKING FROM HOME BECAUSE OF COVID
 19
 IF YOU WOULD LIKE TO CONTACT ME, MY CELL NUMBER IS
 561-718-9724.
 WORKING HOURS ARE MON.- WED. 8:00 AM- NOON. PART-TIME/
 RETIRED.
  
 JAMES A. WITMER BN, PX, SFP, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2021-02-27 Cont ID  
Sent By fgiaquin Date 2021-02-27 Time 17:17 Rev Time 0.00
Received By fgiaquin Date 2021-02-27 Time 15:59 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2021-02-04 Cont ID  
Sent By fgiaquin Date 2021-02-04 Time 00:00 Rev Time 0.00
Received By fgiaquin Date 2021-02-03 Time 22:52 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2021-02-25 Cont ID  
Sent By pleduc Date 2021-02-25 Time   Rev Time 0.00
Received By pleduc Date 2021-02-25 Time 12:09 Sent To  
Notes
2021-02-25 12:52:58FIRE PROVISO:
  
  
 THE FIRE SPRINKLER AND FIRE ALARM SYSTEMS SHALL BE
 MAINTAINED THROUGHOUT CONSTRUCTION, INCLUDING DEMO.
  
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2021-01-25 Cont ID  
Sent By pleduc Date 2021-01-25 Time   Rev Time 0.00
Received By pleduc Date 2021-01-25 Time 13:44 Sent To  
Notes
2021-01-25 13:44:54FIRE PROVISO:
  
  
 THE FIRE SPRINKLER AND FIRE ALARM SYSTEMS SHALL BE
 MAINTAINED THROUGHOUT CONSTRUCTION, INCLUDING DEMO.
  
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2021-03-04 Cont ID  
Sent By medwards Date 2021-03-04 Time 09:09 Rev Time 0.00
Received By medwards Date 2021-02-23 Time 18:49 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2021-02-04 Cont ID  
Sent By fgiaquin Date 2021-02-04 Time 00:00 Rev Time 0.00
Received By fgiaquin Date 2021-01-22 Time 14:36 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2021-03-04 Cont ID  
Sent By medwards Date 2021-03-04 Time 09:07 Rev Time 0.00
Received By medwards Date 2021-03-01 Time 13:40 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2021-02-01 Cont ID  
Sent By hmoser Date 2021-02-01 Time 12:26 Rev Time 0.00
Received By hmoser Date 2021-02-01 Time 09:17 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status N Date 2021-02-03 Cont ID  
Sent By ccole Date 2021-02-03 Time 13:39 Rev Time 0.00
Received By ccole Date 2021-02-03 Time 12:03 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2021-02-24 Cont ID  
Sent By jwitmer Date 2021-02-24 Time 08:32 Rev Time 0.00
Received By jwitmer Date 2021-02-24 Time 08:24 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2021-02-04 Cont ID  
Sent By fgiaquin Date 2021-02-04 Time 00:00 Rev Time 0.00
Received By fgiaquin Date 2021-02-04 Time 00:00 Sent To  
Notes
***NONE***