| Plan Review Stops For Permit 21010690 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2021-04-08 |
|
|
Cont ID |
|
| Sent By |
chtroop |
Date |
2021-04-08 |
Time |
15:20 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-04-08 |
Time |
14:17 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2021-03-12 |
|
|
Cont ID |
|
| Sent By |
chtroop |
Date |
2021-03-12 |
Time |
14:38 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-03-12 |
Time |
11:10 |
Sent To |
|
|
| Notes |
| 2021-03-12 14:41:12 | PLAN REVIEW / BUILDING | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | PLANS EXAMINER ? PX3169 / 1&2 FAMILY - SFP306 | | | INSPECTOR ? BN4338 | | | BUILDING OFFICIAL ? BU1635 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | CODES IN EFFECT: | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | 2014 NEC | | | | | | 2ND REVIEW | | | | | | RESPONSE LETTER FROM DESIGNER STATES "SEE REVISED | | | VALUE". I CANNOT LOCATE ANY REFERENCE TO A CHANGED | | | VALUE. | | | | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. VALUE. | | | THE SOW HAS CHANGED FROM A RES REMOD OF A WOOD FRAMED | | | STRUCTURE TO THE DEMOLITION AND RE-BUILD OF THE | | | STRUCTURE USING TYPE IIIB CONSTRUCTION (CMU EXT. | | | WALLS). THE VALUE OF THE NEW STRUCTURE BASED ON THE ICC | | | BUILDING VALUATION DATA IS $39,347.00. THE VALUE OF THE | | | RES REMOD WAS $15,000.00. PLEASE SUBMIT A NEW VALUE. | | | YOU MAY APPLY A CREDIT FOR NO KITCHEN. | | | FINAL BUILDING PERMIT VALUATION SHALL BE SET BY THE | | | BUILDING OFFICIAL | | | CITY OF WPB CHPT. VALUE 109.3 BUILDING PERMIT | | | VALUATIONS. | | | | | | 2. CORRECTED | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2021-03-02 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-03-02 |
Time |
09:52 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-03-02 |
Time |
06:38 |
Sent To |
|
|
| Notes |
| 2021-03-02 10:06:43 | PLAN REVIEW / BUILDING | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | PLANS EXAMINER ? PX3169 / 1&2 FAMILY - SFP306 | | | INSPECTOR ? BN4338 | | | BUILDING OFFICIAL ? BU1635 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | CODES IN EFFECT: | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | 2014 NEC | | | | | | 1ST REVIEW | | | | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. VALUE. | | | THE SOW HAS CHANGED FROM A RES REMOD OF A WOOD FRAMED | | | STRUCTURE TO THE DEMOLITION AND RE-BUILD OF THE | | | STRUCTURE USING TYPE IIIB CONSTRUCTION (CMU EXT. | | | WALLS). THE VALUE OF THE NEW STRUCTURE BASED ON THE ICC | | | BUILDING VALUATION DATA IS $39,347.00. THE VALUE OF THE | | | RES REMOD WAS $15,000.00. PLEASE SUBMIT A NEW VALUE. | | | YOU MAY APPLY A CREDIT FOR NO KITCHEN. | | | FINAL BUILDING PERMIT VALUATION SHALL BE SET BY THE | | | BUILDING OFFICIAL | | | CITY OF WPB CHPT. VALUE 109.3 BUILDING PERMIT | | | VALUATIONS. | | | | | | 2. CHANGE BUILDING CAT. ON SHEET 01 FROM VB TO IIIB. | | | 602.3 TYPE III. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2021-03-12 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-03-12 |
Time |
14:33 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-03-12 |
Time |
11:10 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2021-03-02 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-03-02 |
Time |
10:09 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-03-02 |
Time |
06:38 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2021-04-08 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-04-08 |
Time |
15:20 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-03-25 |
Time |
10:01 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2021-03-12 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-03-12 |
Time |
14:41 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-03-11 |
Time |
07:41 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2021-03-02 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-03-02 |
Time |
10:25 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-02-26 |
Time |
10:20 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2021-03-12 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-03-12 |
Time |
14:33 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-03-12 |
Time |
11:11 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2021-03-02 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-03-02 |
Time |
10:19 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-03-02 |
Time |
10:19 |
Sent To |
|
|
| Notes |
| 2021-03-02 10:20:53 | PLAN REVIEW / MECHANICAL | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | PLANS EXAMINER PX3169 / 1&2 FAMILY - SFP306 | | | INSPECTOR BN4338 | | | BUILDING OFFICIAL BU1635 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | CODES IN EFFECT: | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | 2014 NEC | | | | | | 1ST REVIEW | | | | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. PLAN SHEET 01 SHOWS MINI SPLIT C/U LOCATED AT REAR | | | OF STRUCTURE. PLAN SHEET E-1 SHOWS TWO C/U'S. PLEASE | | | CLARIFY? | | | 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS | | | SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH | | | 107.2.5. | | | | | | 2. SERVICE OUTLET REQUIRED AT MECH. EQUIPMENT. | | | E3901.12 HVAC OUTLET. | | | A 125-VOLT, SINGLE-PHASE, 15- OR 20-AMPERE-RATED | | | RECEPTACLE OUTLET SHALL BE INSTALLED AT AN ACCESSIBLE | | | LOCATION FOR THE SERVICING OF HEATING, AIR-CONDITIONING | | | AND REFRIGERATION EQUIPMENT. THE RECEPTACLE SHALL BE | | | LOCATED ON THE SAME LEVEL AND WITHIN 25 FEET (7620 MM) | | | OF THE HEATING, AIR-CONDITIONING AND REFRIGERATION | | | EQUIPMENT. THE RECEPTACLE OUTLET SHALL NOT BE CONNECTED | | | TO THE LOAD SIDE OF THE HVAC EQUIPMENT DISCONNECTING | | | MEANS. (210.63) | | | | | | 3. PROVIDE A CONDENSATE DISPOSAL PLAN- FBC R M1411.3 | | | M1411.3 CONDENSATE DISPOSAL. | | | CONDENSATE FROM COOLING COILS AND EVAPORATORS SHALL BE | | | CONVEYED FROM THE DRAIN PAN OUTLET TO AN APPROVED PLACE | | | OF DISPOSAL. SUCH PIPING SHALL MAINTAIN A MINIMUM | | | HORIZONTAL SLOPE IN THE DIRECTION OF DISCHARGE OF NOT | | | LESS THAN 1/8 UNIT VERTICAL IN 12 UNITS HORIZONTAL | | | (1-PERCENT SLOPE). CONDENSATE SHALL NOT DISCHARGE INTO | | | A STREET, ALLEY OR OTHER AREAS WHERE IT WOULD CAUSE A | | | NUISANCE. | | | | | | | | | 4. TIE DOWN | | | M1401.4EXTERIOR INSTALLATIONS. | | | EQUIPMENT AND APPLIANCES INSTALLED OUTDOORS SHALL BE | | | LISTED AND LABELED FOR OUTDOOR INSTALLATION. SUPPORTS | | | AND FOUNDATIONS SHALL PREVENT EXCESSIVE VIBRATION, | | | SETTLEMENT OR MOVEMENT OF THE EQUIPMENT. SUPPORTS AND | | | FOUNDATIONS SHALL BE IN ACCORDANCE WITH SECTION | | | M1305.1.4.1. | | | | | | 5. M1411.8 LOCKING ACCESS PORT CAPS. | | | REFRIGERANT CIRCUIT ACCESS PORTS LOCATED OUTDOORS SHALL | | | BE FITTED WITH LOCKING-TYPE TAMPER-RESISTANT CAPS OR | | | SHALL BE OTHERWISE SECURED TO PREVENT UNAUTHORIZED | | | ACCESS. | | | A NOTE ON PLAN WILL SUFFICE. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2021-03-12 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-03-12 |
Time |
14:41 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-03-12 |
Time |
14:41 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2021-03-02 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-03-02 |
Time |
10:25 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-03-02 |
Time |
06:35 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
3 |
Status |
P |
Date |
2021-04-08 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-04-08 |
Time |
15:20 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-04-08 |
Time |
14:18 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
2 |
Status |
F |
Date |
2021-03-12 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-03-12 |
Time |
14:34 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-03-12 |
Time |
11:11 |
Sent To |
|
|
| Notes |
| 2021-03-12 14:35:30 | PLAN REVIEW / ROOFING | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | PLANS EXAMINER ? PX3169 / 1&2 FAMILY - SFP306 | | | INSPECTOR ? BN4338 | | | BUILDING OFFICIAL ? BU1635 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | CODES IN EFFECT: | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | 2014 NEC | | | | | | 2ND REVIEW | | | | | | 1ST REVIEW COMMENTS HAVE NOT BEEN ADDRESSED. | | | | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. BUILDING IS DESIGNED WITH A FLOT ROOF. PRODUCT | | | APPROVALS SUBMITTED FOR REVIEW ARE FOR SHINGLES. | | | PROVIDE PRODUCT APPROVALS FOR A FLAT ROOF SYSTEM. | | | . FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE | | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | SPECIFICALLY, PROVIDE ROOFING SUBMITTALS. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2021-03-02 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-03-02 |
Time |
10:06 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-03-02 |
Time |
07:18 |
Sent To |
|
|
| Notes |
| 2021-03-02 10:09:33 | PLAN REVIEW / ROOFING | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | PLANS EXAMINER ? PX3169 / 1&2 FAMILY - SFP306 | | | INSPECTOR ? BN4338 | | | BUILDING OFFICIAL ? BU1635 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | CODES IN EFFECT: | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | 2014 NEC | | | | | | 1ST REVIEW | | | | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. BUILDING IS DESIGNED WITH A FLOT ROOF. PRODUCT | | | APPROVALS SUBMITTED FOR REVIEW ARE FOR SHINGLES. | | | PROVIDE PRODUCT APPROVALS FOR A FLAT ROOF SYSTEM. | | | . FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE | | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | SPECIFICALLY, PROVIDE ROOFING SUBMITTALS. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2021-03-12 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-03-12 |
Time |
14:33 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-03-12 |
Time |
11:11 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2021-03-01 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-03-01 |
Time |
06:12 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-03-01 |
Time |
06:12 |
Sent To |
|
|
| Notes |
| 2021-03-01 06:17:17 | ORIGINAL SIGNED AND SEALED PAPER DRAWINGS ROUTED TO | | | STORAGE. ME |
|
|