Plan Review Details - Permit 21010689
Plan Review Stops For Permit 21010689
Review Stop E ELECTRICAL
Rev No 2 Status P Date 2021-02-19 Cont ID  
Sent By equinone Date 2021-02-19 Time 10:31 Rev Time 0.00
Received By equinone Date 2021-02-19 Time 10:04 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2021-02-03 Cont ID  
Sent By equinone Date 2021-02-03 Time 10:52 Rev Time 0.00
Received By equinone Date 2021-02-02 Time 16:23 Sent To  
Notes
2021-02-03 10:58:21CODES IN EFFECT
 CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2020 7TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2020
 7TH ED, CHAPTER 1.
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020
 7TH EDITION
 FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2020
 7TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2020 7TH EDITION
 NEC = NFPA 70 2017 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
 FAC = FLORIDA ADMINISTRATIVE CODE
  
 ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 1) SHEET G-102 (GENERAL ELECTRICAL NOTE 1): PLEASE
 CHANGE TO COMPLY WITH FBC 2020 7TH EDITION AND NEC
 2017.
 2) SHEET E101 (ONE-LINE DIAGRAM): MAXIMUM PRIMARY
 OVERCURRENT PROTECTION FOR TRANSFORMER MT-5 SHOULD BE
 50 AMPS. PLEASE CORRECT. NEC 450(3)(B), NEC 240.4
 3) PLEASE SUBMIT PANELS SCHEDULES FOR PDP-3A, PP-5, AND
 LP-3 FBC 107
 4) PLEASE SPECIFY AVAILABLE SHORT CIRCUIT CURRENTS AT
 MDS AND PANELS FBC 107
 5) SHEET E-103 (MAINS SWITCHBOARD ROOM): PLEASE SHOW
 DISTANCES FROM MDS TO WALLS TO SHOW COMPLIANCE WITH NEC
 110.26(C)(2)
 6) PLEASE SEE SIGNATURE COMMENTS
  
 END OF COMMENTS.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES
 INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE
 PREVIOUSLY REVIEWED SHEETS.
 CODES IN EFFECT:
  
 ENRIQUE QUINONEZ P.E.
 ELECTRICAL PLANS EXAMINER
 561-805-6746
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2021-02-19 Cont ID  
Sent By equinone Date 2021-02-19 Time 10:32 Rev Time 0.00
Received By equinone Date 2021-02-11 Time 14:10 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2021-02-03 Cont ID  
Sent By equinone Date 2021-02-03 Time 10:58 Rev Time 0.00
Received By equinone Date 2021-01-20 Time 10:56 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2021-02-19 Cont ID  
Sent By equinone Date 2021-02-19 Time 10:31 Rev Time 0.00
Received By equinone Date 2021-02-19 Time 10:31 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2021-02-03 Cont ID  
Sent By equinone Date 2021-02-03 Time 10:16 Rev Time 0.00
Received By equinone Date 2021-02-03 Time 10:16 Sent To  
Notes
2021-02-03 10:22:55ENRIQUE QUINONEZ
 ELECTRICAL PLANS EXAMINER
 [email protected]
 561-805-6746
  
  
 FOR ALL DRAWINGS SUBMITTED FOR THIS PERMIT:
  
 DOCUMENTS PREPARED BY AN ARCHITECT OR ENGINEER AND
 SUBMITTED FOR PUBLIC RECORD ARE TO BE SIGNED, SEALED,
 DATED ORIGINALS. A SCAN OF A SIGNED PLAN IS NOT
 CONSIDERED AN ORIGINAL. FS471, FS481,
  
 EITHER UPLOAD DIGITALLY OR ELECTRONICALLY SIGNED PLANS
 OR YOU CAN SUBMIT SIGNED AND SEALED PAPER ORIGINALS
 WITH A WET SIGNATURE.
  
 ENRIQUE QUINONEZ
 ELECTRICAL PLANS EXAMINER
 DEVELOPMENT SERVICES
 CITY OF WEST PALM BEACH
 401 CLEMATIS STREET, 1ST FLOOR
 WEST PALM BEACH, FL 33401
  
 FEEL FREE TO CONTACT ME IF YOU WISH TO DISCUSS,
 561-805-6746.
  