Plan Review Details - Permit 21010689
| Plan Review Stops For Permit 21010689 |
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2021-02-19 |
|
|
Cont ID |
|
| Sent By |
equinone |
Date |
2021-02-19 |
Time |
10:31 |
Rev Time |
0.00 |
| Received By |
equinone |
Date |
2021-02-19 |
Time |
10:04 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2021-02-03 |
|
|
Cont ID |
|
| Sent By |
equinone |
Date |
2021-02-03 |
Time |
10:52 |
Rev Time |
0.00 |
| Received By |
equinone |
Date |
2021-02-02 |
Time |
16:23 |
Sent To |
|
|
| Notes |
| 2021-02-03 10:58:21 | CODES IN EFFECT | | | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2020 7TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2020 | | | 7TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 | | | 7TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2020 | | | 7TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2020 7TH EDITION | | | NEC = NFPA 70 2017 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | FAC = FLORIDA ADMINISTRATIVE CODE | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1) SHEET G-102 (GENERAL ELECTRICAL NOTE 1): PLEASE | | | CHANGE TO COMPLY WITH FBC 2020 7TH EDITION AND NEC | | | 2017. | | | 2) SHEET E101 (ONE-LINE DIAGRAM): MAXIMUM PRIMARY | | | OVERCURRENT PROTECTION FOR TRANSFORMER MT-5 SHOULD BE | | | 50 AMPS. PLEASE CORRECT. NEC 450(3)(B), NEC 240.4 | | | 3) PLEASE SUBMIT PANELS SCHEDULES FOR PDP-3A, PP-5, AND | | | LP-3 FBC 107 | | | 4) PLEASE SPECIFY AVAILABLE SHORT CIRCUIT CURRENTS AT | | | MDS AND PANELS FBC 107 | | | 5) SHEET E-103 (MAINS SWITCHBOARD ROOM): PLEASE SHOW | | | DISTANCES FROM MDS TO WALLS TO SHOW COMPLIANCE WITH NEC | | | 110.26(C)(2) | | | 6) PLEASE SEE SIGNATURE COMMENTS | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | CODES IN EFFECT: | | | | | | ENRIQUE QUINONEZ P.E. | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2021-02-19 |
|
|
Cont ID |
|
| Sent By |
equinone |
Date |
2021-02-19 |
Time |
10:32 |
Rev Time |
0.00 |
| Received By |
equinone |
Date |
2021-02-11 |
Time |
14:10 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2021-02-03 |
|
|
Cont ID |
|
| Sent By |
equinone |
Date |
2021-02-03 |
Time |
10:58 |
Rev Time |
0.00 |
| Received By |
equinone |
Date |
2021-01-20 |
Time |
10:56 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2021-02-19 |
|
|
Cont ID |
|
| Sent By |
equinone |
Date |
2021-02-19 |
Time |
10:31 |
Rev Time |
0.00 |
| Received By |
equinone |
Date |
2021-02-19 |
Time |
10:31 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2021-02-03 |
|
|
Cont ID |
|
| Sent By |
equinone |
Date |
2021-02-03 |
Time |
10:16 |
Rev Time |
0.00 |
| Received By |
equinone |
Date |
2021-02-03 |
Time |
10:16 |
Sent To |
|
|
| Notes |
| 2021-02-03 10:22:55 | ENRIQUE QUINONEZ | | | ELECTRICAL PLANS EXAMINER | | | [email protected] | | | 561-805-6746 | | | | | | | | | FOR ALL DRAWINGS SUBMITTED FOR THIS PERMIT: | | | | | | DOCUMENTS PREPARED BY AN ARCHITECT OR ENGINEER AND | | | SUBMITTED FOR PUBLIC RECORD ARE TO BE SIGNED, SEALED, | | | DATED ORIGINALS. A SCAN OF A SIGNED PLAN IS NOT | | | CONSIDERED AN ORIGINAL. FS471, FS481, | | | | | | EITHER UPLOAD DIGITALLY OR ELECTRONICALLY SIGNED PLANS | | | OR YOU CAN SUBMIT SIGNED AND SEALED PAPER ORIGINALS | | | WITH A WET SIGNATURE. | | | | | | ENRIQUE QUINONEZ | | | ELECTRICAL PLANS EXAMINER | | | DEVELOPMENT SERVICES | | | CITY OF WEST PALM BEACH | | | 401 CLEMATIS STREET, 1ST FLOOR | | | WEST PALM BEACH, FL 33401 | | | | | | FEEL FREE TO CONTACT ME IF YOU WISH TO DISCUSS, | | | 561-805-6746. | | | |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |