| Plan Review Stops For Permit 21010451 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2021-03-19 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2021-03-19 |
Time |
10:47 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2021-03-19 |
Time |
10:47 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2021-02-18 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2021-02-18 |
Time |
09:35 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2021-02-18 |
Time |
09:35 |
Sent To |
|
|
| Notes |
| 2021-02-18 09:44:00 | PLAN | | | REVIEW COMMENTS | | | | | | 1ST REVIEW: FBC SEVENTH EDITION (2020) | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY BUILDING | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) THE GENERATOR PAD DRAWING REFERENCES THE FBC SIXTH | | | EDITION (2017). THE FBC SEVENTH EDITION (2020) WENT | | | INTO EFFECT ON DECEMBER 31, 2020. ALL NEW PERMITS | | | APPLIED FOR ON OR AFTER THAT DATE ARE REQUIRED TO | | | COMPLY WITH AND REFERENCE THE 2020 FBC SEVENTH EDITION. | | | FS CHAPTER 553 | | | | | | 2) FBC-R303.5.1 INTAKE OPENINGS. MECHANICAL AND GRAVITY | | | OUTDOOR AIR INTAKE OPENINGS SHALL BE LOCATED NOT LESS | | | THAN 10 FEET (3048 MM) FROM ANY HAZARDOUS OR NOXIOUS | | | CONTAMINANT, SUCH AS VENTS, CHIMNEYS, PLUMBING VENTS, | | | STREETS, ALLEYS, PARKING LOTS AND LOADING DOCKS. | | | SPECIFY THIS ON THE SURVEY THAT SHOWS THE GENERATOR | | | LOCATION. | | | | | | 3) SEE SIGNATURE REVIEW COMMENTS. | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2021-06-16 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2021-06-16 |
Time |
18:59 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2021-06-16 |
Time |
18:55 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2021-05-24 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2021-05-24 |
Time |
16:38 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2021-05-24 |
Time |
16:33 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2021-03-26 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2021-03-26 |
Time |
16:35 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2021-03-26 |
Time |
16:35 |
Sent To |
|
|
| Notes |
| 2021-03-26 16:45:29 | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | FLORIDA BUILDING CODE 2020 7TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 7TH ED | | | NFPA 70 2017 EDITION | | | | | | JAKE LEAHY BN, BU, PX | | | ELECTRICAL PLANS EXAMINER II | | | 561-805-6713 | | | [email protected] | | | | | | 1) RISER SHOWS A 150A TRANSFER SWITCH WITH A 200A | | | BREAKER???? | | | | | | 2) 200A SERVICE REQUIRES 3/0 CU OR EQUIVALENT AL ENTIRE | | | LOAD NOT BEING FED BY ONE MAIN. 310.15(B)(7)(1) | | | | | | FOR A SERVICE RATED 100 THROUGH 400 AMPERES, THE | | | SERVICE CONDUCTORS SUPPLYING THE ENTIRE LOAD ASSOCIATED | | | WITH A ONE-FAMILY DWELLING, OR THE SERVICE CONDUCTORS | | | SUPPLYING THE ENTIRE LOAD ASSOCIATED WITH AN INDIVIDUAL | | | DWELLING UNIT IN A TWO-FAMILY OR MULTIFAMILY DWELLING, | | | SHALL BE PERMITTED TO HAVE AN AMPACITY NOT LESS THAN 83 | | | PERCENT OF THE SERVICE RATING. THIS DOES NOT APPLY TO | | | YOUR INSTALLATION | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2021-02-10 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2021-02-10 |
Time |
15:17 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2021-02-10 |
Time |
15:08 |
Sent To |
|
|
| Notes |
| 2021-02-10 15:21:30 | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | FLORIDA BUILDING CODE 2020 7TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 7TH ED | | | NFPA 70 2017 EDITION | | | | | | JAKE LEAHY BN, BU, PX | | | ELECTRICAL PLANS EXAMINER II | | | 561-805-6713 | | | [email protected] | | | | | | ELECTRICAL PLAN HAS TWO DIFFERENT SIZES FOR THE | | | GENERATOR 16KW AND 22KW? WHICH ONE. | | | | | | TRANSFER SWITCH SPECS WHICH ONE? PLEASE HIGHLIGHT WHICH | | | ONE BEING USED. | | | | | | GENERATOR SPECS WHICH ONE? PLEASE HIGHLIGHT WHICH ONE | | | IS BEING USED. | | | | | | VALUE OF JOB (5200) TO LOW FOR EVEN A 16KW GENERATOR. | | | SUBMIT A SIGNED CONTRACT WITH THE OWNER FOR THE JOB. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2021-06-16 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2021-06-16 |
Time |
19:00 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2021-06-09 |
Time |
11:15 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2021-05-24 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2021-05-24 |
Time |
16:45 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2021-05-14 |
Time |
14:42 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2021-04-15 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2021-04-15 |
Time |
08:46 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2021-03-18 |
Time |
08:28 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2021-02-18 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2021-02-18 |
Time |
09:49 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2021-01-27 |
Time |
10:46 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
4 |
Status |
P |
Date |
2021-06-16 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2021-06-16 |
Time |
19:00 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2021-06-16 |
Time |
18:59 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
P |
Date |
2021-05-24 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2021-05-24 |
Time |
16:38 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2021-05-24 |
Time |
16:38 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2021-03-19 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2021-03-19 |
Time |
10:47 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2021-03-19 |
Time |
10:47 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2021-02-18 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2021-02-18 |
Time |
09:44 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2021-02-18 |
Time |
09:44 |
Sent To |
|
|
| Notes |
| 2021-02-18 09:47:57 | THE GENERATOR PAD DRAWINGS FOR THE 2020 FBC WILL BE | | | RQUIRED TO HAVE THE ENGINEER'S DIGITAL SIGNATURE ON | | | THEM. COPIES OF DIGITALLY SIGNED DOCUMENTS ARE NOT | | | ACCEPTABLE. ELECTRONICALLY SUBMITTED DRAWINGS ARE | | | REQUIRED TO HAVE THE ENGINEER'S DIGITAL SIGNATURE ON | | | THEM. YOU ALSO HAVE THE OPTION TO SUBMIT THE SIGNED AND | | | SEALED PAPER VERSION OF DRAWINGS. AFTER THE ELECTRONIC | | | PLANS HAVE BEEN APPROVED, YOU CAN SUBMIT THE | | | CORRESPONDING PAPER DRAWINGS AT THE BUILDING DEPARTMENT | | | TO BE VERIFIED. THE ENGINEER'S ORIGINAL HANDWRITTEN | | | SIGNATURE AND SEAL IS REQUIRED TO BE ON THE DRAWINGS. | | | NO PHOTOCOPY OR OTHER FACSIMILES OF THE SIGNATURE ARE | | | ACCEPTABLE. FS 471 & 61G15 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2021-04-14 |
|
|
Cont ID |
|
| Sent By |
kalexand |
Date |
2021-04-14 |
Time |
08:38 |
Rev Time |
0.00 |
| Received By |
kalexand |
Date |
2021-04-14 |
Time |
08:38 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2021-02-17 |
|
|
Cont ID |
|
| Sent By |
kalexand |
Date |
2021-02-17 |
Time |
09:01 |
Rev Time |
0.00 |
| Received By |
kalexand |
Date |
2021-02-17 |
Time |
09:00 |
Sent To |
|
|
| Notes |
|
|