Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2021-01-27 Cont ID  
Sent By chtroop Date 2021-01-27 Time 10:27 Rev Time 0.00
Received By cthroop Date 2021-01-27 Time 10:27 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2021-01-11 Cont ID  
Sent By cthroop Date 2021-01-11 Time 16:43 Rev Time 0.00
Received By cthroop Date 2021-01-11 Time 16:24 Sent To  
Notes
2021-01-11 16:45:12PLAN REVIEW / BUILDING
 CHRISTOPHER S. THROOP, C.B.O.
 PLANS EXAMINER BUILDING - PX3169
 PLANS EXAMINER 1&2 FAMILY - SFP306
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 CODES IN EFFECT:
 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 2017 NEC
  
 1ST REVIEW
  
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. PROVIDE DESIGN PRESSURES OF EACH OPENING.
 FBC 107.3.5.3 ? PROVIDE WIND DESIGN LOADS/DESIGN
 PRESSURES PURSUANT TO FBC-R301.2.

Review Stop HIST HISTORICAL
Rev No 2 Status P Date 2021-01-27 Cont ID  
Sent By aborngra Date 2021-01-27 Time 12:31 Rev Time 0.00
Received By aborngra Date 2021-01-27 Time 12:30 Sent To  
Notes
2021-01-27 12:31:29THE PERMIT HAS BEEN APPROVED WITH THE FOLLOWING
 CONDITION(S):
 1. ALL REPLACEMENT WINDOWS SHALL BE SIZED TO FIT THE
 ORIGINAL WINDOW FRAME OPENING (X-AXIS AND Y-AXIS) AND
 MATCH THE LOCATION/DEPTH (Z-AXIS) OF THE ORIGINAL
 WINDOWS.
 2. THE EXISTING MULLION SHALL REMAIN OR BE REPLACED
 WITH A MULLION OF MATCHING WIDTH AND PLACEMENT.
 3. ALL STREET OR SIDEWALK FACING GLASS SHALL BE CLEAR.
 ALL NON-STREET FACING GLASS SHALL BE CLEAR OR CLEAR
 WITH LOW-E COATING. NO TINT. OBSCURED TEXTURED GLASS
 MAY BE USED ON NON-STREET FACING BATHROOMS ONLY.
 4. ALL MUNTINS SHALL HAVE AN EXTERNAL DIMENSIONAL
 PROFILE.
  
 AARON BORNGRABER
 HISTORIC PRESERVATION PLANNER | DEVELOPMENT SERVICES
 PLANNING DIVISION
 [email protected] | OFFICE: 561.822.1428 | TTY:
 800.955.8771
 401 CLEMATIS STREET | P.O BOX 3147 | WEST PALM BEACH,
 FL 33402
  

Review Stop HIST HISTORICAL
Rev No 1 Status F Date 2021-01-20 Cont ID  
Sent By aborngra Date 2021-01-20 Time 15:29 Rev Time 0.00
Received By aborngra Date 2021-01-20 Time 15:29 Sent To  
Notes
2021-01-20 15:29:06THE PERMIT HAS FAILED FOR THE FOLLOWING REASON(S):
 1. ALL WINDOW REPLACEMENT WORK REQUIRES TO FOLLOW THE
 WINDOW PERMIT APPLICATION EXAMPLE. PLEASE EMAIL STAFF
 AT [email protected] TO REQUEST THE EXAMPLE. AT
 MINIMUM, STAFF NEEDS TO KNOW THE EXISTING WINDOWS AND
 THE PROPOSED WINDOWS EXTERIOR FRAME COLOR, GLASS
 GLAZING, LITE PATTERN, MUNTIN PROFILE AND MULLION
 WIDTH. A PHOTO OF EACH ELEVATION WITH EACH WINDOW
 MARKED.
 2. PROVIDE A MUNTIN DETAIL FOR ECO WINDOWS SYSTEMS. AN
 EXTERNAL MUNTIN WITH A FLAT PROFILE WILL NOT BE
 APPROVED. THE MUNTIN PROFILE SHOULD BE OGEE.
 3. REMOVE WHITE INTERLAY FROM ALL WINDOWS. OBSCURED
 TEXTURED GLASS IS OKAY IF A BATHROOM AND NOT STREET
 FACING.
 4. REVISE WINDOW WITH A WIDTH OF 53 INCHES TO BE A 6/6.
 5. IT WOULD BE BEST TO REVISE WINDOWS WITH A WIDTH OF
 36 INCHES TO BE A 6/6. THIS IS NOT A REQUIREMENT.
  
 PROPOSED CONDITIONS, SUBJECT TO CHANGE:
 1. ALL REPLACEMENT WINDOWS SHALL BE SIZED TO FIT THE
 ORIGINAL WINDOW FRAME OPENING (X-AXIS AND Y-AXIS) AND
 MATCH THE LOCATION/DEPTH (Z-AXIS) OF THE ORIGINAL
 WINDOWS.
 2. THE EXISTING MULLION SHALL REMAIN OR BE REPLACED
 WITH A MULLION OF MATCHING WIDTH AND PLACEMENT.
 3. ALL STREET OR SIDEWALK FACING GLASS SHALL BE CLEAR.
 ALL NON-STREET FACING GLASS SHALL BE CLEAR OR CLEAR
 WITH LOW-E COATING. NO TINT. OBSCURED TEXTURED GLASS
 MAY BE USED ON NON-STREET FACING BATHROOMS ONLY.
  
 AARON BORNGRABER
 HISTORIC PRESERVATION PLANNER | DEVELOPMENT SERVICES
 PLANNING DIVISION
 [email protected] | OFFICE: 561.822.1428 | TTY:
 800.955.8771
 401 CLEMATIS STREET | P.O BOX 3147 | WEST PALM BEACH,
 FL 33402
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2021-01-27 Cont ID  
Sent By cpuell Date 2021-01-27 Time 12:40 Rev Time 0.00
Received By cpuell Date 2021-01-26 Time 14:59 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2021-01-22 Cont ID  
Sent By jleahy Date 2021-01-22 Time 09:42 Rev Time 0.00
Received By jleahy Date 2021-01-08 Time 10:28 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status N Date 2021-01-11 Cont ID  
Sent By cthroop Date 2021-01-11 Time 16:43 Rev Time 0.00
Received By cthroop Date 2021-01-11 Time 16:25 Sent To  
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved