| Plan Review Stops For Permit 20121419 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2021-03-01 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-03-01 |
Time |
14:11 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-03-01 |
Time |
13:56 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2021-01-21 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-01-21 |
Time |
12:26 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-01-21 |
Time |
09:34 |
Sent To |
|
|
| Notes |
| 2021-01-21 11:27:44 | SFR ADDITION | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected]. | | | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 | | | AMENDMENTS | | | | | | CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107 | | | 1) DRAWING SHOWS 2017 FBC USED FOR DESIGN - AS OR | | | 1/1/2021 CODE IN EFFECT IS THE 2020 FBC AND ASCE 7-16 - | | | PLEASE REVISE THE DRAWINGS TO REFLECT THE CODE IN | | | EFFECT. | | | 2) PLEASE SHOW THAT THE EMERGENCY EGRESS STILL EXISTS | | | IN THE BEDROOMS ADJACENT TO THE ADDITION FBC R310 | | | 3) PLEASE SHOW THE ATTIC ACCESS SIZE AND LOCATION TO | | | COMPLY WITH FBC R807.1 | | | 4) PLEASE REVISE THE BUILDING PERMIT APPLICATION | | | SHOWING THE ACTUAL JOB COST (LABOR AND MATERIAL AS IF | | | CONTRACTED BY A CONTRACTOR) AC SPACE = 580 SQ. FT X | | | $122.00 PER SQ. FT = $70,760.00 | | | 5) PLEASE PROVIDE THE FRONT PAGES FOR FLORIDA PRODUCT | | | APPROVALS FL21844 AND FL21848.3 (INSTALLATION | | | INSTRUCTIONS HAVE BEEN PROVIDED). | | | 6) PLEASE SHOW THE LOCATIONS OF THE REQUIRED SMOKE | | | ALARMS THROUGHOUT THE EXISTING HOUSE TO COMPLY WITH FBC | | | R314.2.2 ALTERATIONS, REPAIRS AND ADDITIONS. WHERE | | | ALTERATIONS, REPAIRS OR ADDITIONS REQUIRING A PERMIT | | | OCCUR, OR WHERE ONE OR MORE SLEEPING ROOMS ARE ADDED OR | | | CREATED IN EXISTING DWELLINGS, THE INDIVIDUAL DWELLING | | | UNIT SHALL BE EQUIPPED WITH SMOKE ALARMS LOCATED AS | | | REQUIRED FOR NEW DWELLINGS. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2021-02-25 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2021-02-25 |
Time |
11:21 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2021-02-25 |
Time |
11:07 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2021-01-15 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2021-01-15 |
Time |
17:39 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2021-01-15 |
Time |
17:39 |
Sent To |
|
|
| Notes |
| 2021-01-15 17:50:13 | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | FLORIDA BUILDING CODE 2017 6TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 6TH ED | | | NFPA 70 2014 EDITION | | | | | | JAKE LEAHY BN, BU, PX | | | ELECTRICAL PLANS EXAMINER II | | | 561-805-6713 | | | [email protected] | | | | | | 1) OUTLETS IN BATHROOM CAN NOT SHARE OUTLETS IN LIVING | | | AREA. | | | | | | 210.11(C)(3) BATHROOM BRANCH CIRCUITS. IN ADDITION TO | | | THE NUMBER OF BRANCH CIRCUITS REQUIRED BY OTHER PARTS | | | OF THIS SECTION, AT LEAST ONE 120-VOLT, 20-AMPERE | | | BRANCH CIRCUIT SHALL BE PROVIDED TO SUPPLY THE | | | BATHROOM(S) RECEPTACLE OUTLET(S). SUCH CIRCUITS SHALL | | | HAVE NO OTHER OITLET. | | | | | | 2) PANELS SCHEDULE HAS DIFFERENT LOCATIONS FOR OUTLETS. | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2021-03-01 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-03-01 |
Time |
14:11 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-02-10 |
Time |
10:22 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2021-01-21 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-01-21 |
Time |
12:39 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-01-06 |
Time |
09:42 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
P |
Date |
2021-03-08 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2021-03-08 |
Time |
11:27 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2021-03-01 |
Time |
15:16 |
Sent To |
|
|
| Notes |
| 2021-03-05 15:53:40 | RECEIPT MU-2021-9897 - $546.52 - PAID | | 2021-03-01 15:17:01 | 3/1/21 EMAILED IMPACT OFFICE FOR REVIEW. LEM |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2021-01-21 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-01-21 |
Time |
12:27 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-01-21 |
Time |
12:27 |
Sent To |
|
|
| Notes |
| 2021-01-21 12:28:11 | PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE | | | DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS | | | OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST | | | FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE | | | OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL | | | IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME | | | THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM | | | CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS | | | TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF | | | | | | UPON APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE | | | RECEIPT TO YOUR PROJECT OR EMAIL IT TO | | | [email protected] . | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2021-01-13 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-01-13 |
Time |
16:25 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-01-13 |
Time |
16:09 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2021-01-08 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2021-01-08 |
Time |
06:33 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2021-01-08 |
Time |
06:18 |
Sent To |
|
|
| Notes |
| 2021-01-08 06:34:23 | 01/08/21 REVIEWED FOR CODE COMPLIANCE (PLUMBING) | | | | | | BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE | | | COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN | | | PROFESSIONAL, CONTRACTORS, OR THEIR REPRESENTATIVES | | | FROM THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL, | | | STATE, AND NATIONAL CODES AND STANDARDS IN EFFECT AT | | | THE TIME OF PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK | | | OF EVERY ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM | | | REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES | | | / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO | | | AVOID VOIDING OF THE PERMIT. | | | | | | LUIS A. CRESPO | | | PLUMBING PLAN EXAMINER / INSPECTOR | | | EMAIL: [email protected] OFFICE: 561 805-6720 | | | |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
P |
Date |
2021-01-21 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-01-21 |
Time |
12:28 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-01-21 |
Time |
12:28 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2021-03-01 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-03-01 |
Time |
14:11 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-03-01 |
Time |
14:11 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2021-01-21 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-01-21 |
Time |
12:39 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-01-21 |
Time |
12:39 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2021-01-19 |
|
|
Cont ID |
|
| Sent By |
rthermid |
Date |
2021-01-19 |
Time |
|
Rev Time |
|
| Received By |
rthermid |
Date |
2021-01-19 |
Time |
|
Sent To |
I |
|
| Notes |
|
|