| Plan Review Stops For Permit 20121293 |
| Review Stop |
AD |
ADDRESSING |
| Rev No |
1 |
Status |
P |
Date |
2022-01-05 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2022-01-05 |
Time |
12:26 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2022-01-05 |
Time |
12:26 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2023-06-20 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2023-06-20 |
Time |
14:03 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2023-06-20 |
Time |
14:03 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2022-12-19 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2022-12-19 |
Time |
08:13 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2022-12-19 |
Time |
08:13 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2021-12-15 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-12-15 |
Time |
09:08 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-12-15 |
Time |
08:59 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2021-05-04 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-05-04 |
Time |
13:03 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-05-04 |
Time |
13:03 |
Sent To |
|
|
| Notes |
| 2021-05-04 13:07:38 | ANTENNA | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected]. | | | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 | | | AMENDMENT | | | | | | CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107 | | | 1) PLEASE PROVIDE THE STRUCTURAL DETAILS AND | | | CALCULATIONS FROM A DESIGN PROFESSIONAL FOR THE POLE | | | AND MOUNTED ANTENNA SHOWING FOUNDATION AND ATTACHMENTS | | | TO COMPLY WITH THE WIND LOADS PER FBC 1609 | | | 2) WIND SPEED USED FOR DESIGN SHOULD BE 170MPH FOR A | | | RISK CATEGORY II PER FBC WPB SECTION 120. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2021-01-25 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-01-25 |
Time |
08:51 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-01-25 |
Time |
08:39 |
Sent To |
|
|
| Notes |
| 2021-01-25 08:54:34 | | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected]. | | | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 | | | AMENDMENTS | | | | | | CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107 | | | 1) PLANS DO NOT SHOW POLE DETAILS. IS THE POLE A | | | SEPARATE PERMIT? | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
P |
Date |
2023-06-22 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2023-06-22 |
Time |
10:30 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2023-06-22 |
Time |
10:27 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2022-12-19 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2022-12-19 |
Time |
12:16 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2022-12-19 |
Time |
09:47 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2021-12-21 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2021-12-21 |
Time |
12:53 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2021-12-21 |
Time |
12:53 |
Sent To |
|
|
| Notes |
| 2021-12-21 12:55:25 | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | FLORIDA BUILDING CODE 2017 6TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 6TH ED | | | NFPA 70 2014 EDITION | | | 1) AIC RATING FOR SERVICE NOT SHOWN 110.9, 110.10 | | | PROVIDE CALCULATION FOR AVAILABLE SHORT CIRCUIT CURRENT | | | AT NEW PANEL TO CONFIRM AIC RATING IS ADEQUATE. NEC | | | 110.10 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. | | | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2020 7TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE 2020 7TH ED. | | | FBC EB = FLORIDA BUILDING CODE EXISTING BUILDING 2020 | | | 7TH EDITION | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 | | | 7TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2020 7TH EDITION | | | NEC = NFPA 70 2017 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | V/R, | | | | | | MICHAEL PETERSON | | | ELECTRICAL PLANS EXAMINER | | | [email protected] | | | 561-805-6746 | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2021-04-30 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2021-04-30 |
Time |
14:08 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2021-04-30 |
Time |
14:02 |
Sent To |
|
|
| Notes |
| 2021-04-30 14:09:20 | SEE PLAN REVIEW COMMENTS FROM 1/21/21 JLEAHY |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2021-01-21 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2021-01-21 |
Time |
10:50 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2021-01-21 |
Time |
10:43 |
Sent To |
|
|
| Notes |
| 2021-01-21 10:55:45 | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | FLORIDA BUILDING CODE 2017 6TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 6TH ED | | | NFPA 70 2014 EDITION | | | | | | JAKE LEAHY BN, BU, PX | | | ELECTRICAL PLANS EXAMINER II | | | 561-805-6713 | | | [email protected] | | | | | | 1) AIC RATING FOR SERVICE NOT SHOWN 110.9, 110.10 | | | | | | PROVIDE CALCULATION FOR AVAILABLE SHORT CIRCUIT CURRENT | | | AT NEW PANEL TO CONFIRM AIC RATING IS ADEQUATE. NEC | | | 110.10 | | | | | | 2) NO GROUNDING DETAIL FOR ELECTRICAL SERVICE. | | | 250.4(A)(1) |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
2 |
Status |
N |
Date |
2022-01-05 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2022-01-05 |
Time |
13:45 |
Rev Time |
0.00 |
| Received By |
eschneid |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2022-01-05 13:46:15 | REVIEW DONE AS PART OF THE WIRELESS COMM FACILITY |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
F |
Date |
2021-07-01 |
|
|
Cont ID |
|
| Sent By |
gpatrie |
Date |
2021-07-01 |
Time |
09:24 |
Rev Time |
0.00 |
| Received By |
gpatrie |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2021-07-01 09:24:48 | WIRELESS COMMUNICATION REQUIRED. | | | REF: 19020384 | | | | | | CONTACT: [email protected] |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
| Received By |
amcgrego |
Date |
2023-06-14 |
Time |
08:56 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2023-06-08 |
|
|
Cont ID |
|
| Sent By |
aoliver |
Date |
2023-06-08 |
Time |
08:19 |
Rev Time |
0.00 |
| Received By |
aoliver |
Date |
2022-08-31 |
Time |
09:09 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2022-01-21 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2022-01-21 |
Time |
08:19 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2021-12-07 |
Time |
09:03 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2021-07-02 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2021-07-02 |
Time |
11:03 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2021-04-20 |
Time |
13:31 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2021-01-25 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-01-25 |
Time |
08:56 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-01-08 |
Time |
16:32 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
5 |
Status |
P |
Date |
2023-06-20 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2023-06-20 |
Time |
14:08 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2023-06-20 |
Time |
14:08 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
4 |
Status |
F |
Date |
2022-12-19 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2022-12-19 |
Time |
08:12 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2022-12-19 |
Time |
08:12 |
Sent To |
|
|
| Notes |
| 2022-12-19 08:13:25 | SIGNATURE REVIEW | | | | | | DRAWINGS BELOW LABELED IN PROJECTDOX DO NOT SHOW AS | | | DIGITALLY SIGNED IN ADOBE READER - | | | | | | RAYCAP_POLE DESIGN_32-FOOT POLE-09-28-2021.PDF | | | | | | 007 S1 - SURVEY.PDF V2 | | | | | | SIGNED AND SEALED DRAWINGS IN PROJECTDOX NEED TO BE | | | DIGITALLY/ELECTRONICALLY SIGNED BY THE ENGINEER OR | | | ARCHITECT TO BE USED IN ELECTRONIC PLAN REVIEW. (A | | | CERTIFICATE-BASED DIGITAL SIGNATURE (OFTEN JUST CALLED | | | A DIGITAL SIGNATURE) IS A SPECIFIC TYPE OF | | | E-SIGNATURE).- OR - IF YOUR ARCHITECT OR ENGINEER DOES | | | NOT HAVE AN ELECTRONIC OR DIGITAL SIGNATURE - YOU CAN | | | DROP OFF THE ORIGINAL SIGNED AND SEALED | | | DRAWINGS/DOCUMENTS TO THE FRONT DESK IN THE BUILDING | | | DIVISION AT THE CITY HALL. | | | | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected] | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
F |
Date |
2021-12-15 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-12-15 |
Time |
08:59 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-12-15 |
Time |
08:59 |
Sent To |
|
|
| Notes |
| 2021-12-15 09:08:05 | SIGNATURE REVIEW | | | | | | DRAWINGS BELOW LABELED IN PROJECTDOX DO NOT SHOW AS | | | DIGITALLY SIGNED IN ADOBE READER - | | | | | | RAYCAP_POLE DESIGN_32-FOOT POLE-09-28-2021.PDF | | | 007 S1 - SURVEY.PDF V2 | | | | | | SIGNED AND SEALED DRAWINGS IN PROJECTDOX NEED TO BE | | | DIGITALLY/ELECTRONICALLY SIGNED BY THE ENGINEER OR | | | ARCHITECT TO BE USED IN ELECTRONIC PLAN REVIEW. (A | | | CERTIFICATE-BASED DIGITAL SIGNATURE (OFTEN JUST CALLED | | | A DIGITAL SIGNATURE) IS A SPECIFIC TYPE OF | | | E-SIGNATURE).- OR - IF YOUR ARCHITECT OR ENGINEER DOES | | | NOT HAVE AN ELECTRONIC OR DIGITAL SIGNATURE - YOU CAN | | | DROP OFF THE ORIGINAL SIGNED AND SEALED | | | DRAWINGS/DOCUMENTS TO THE FRONT DESK IN THE BUILDING | | | DIVISION AT THE CITY HALL. | | | | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected] | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2021-05-04 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-05-04 |
Time |
13:07 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-05-04 |
Time |
13:07 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2021-01-25 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-01-25 |
Time |
08:52 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-01-25 |
Time |
08:52 |
Sent To |
|
|
| Notes |
| 2021-01-25 08:55:24 | SIGNED AND SEALED DRAWINGS IN PROJECTDOX NEED TO BE | | | DIGITALLY/ELECTRONICALLY SIGNED BY THE ENGINEER OR | | | ARCHITECT TO BE USED IN ELECTRONIC PLAN REVIEW. | | | DRAWINGS DO NOT SHOW IN "ADOBE READER" AS | | | DIGITALLY/ELECTRONICALLY SIGNED. - OR - IF YOUR | | | ARCHITECT OR ENGINEER DOES NOT HAVE AN ELECTRONIC OR | | | DIGITAL SIGNATURE ? YOU CAN MAIL IN OR DROP OFF THE | | | ORIGINAL SIGNED AND SEALED DRAWINGS/DOCUMENTS TO THE | | | FRONT DESK IN THE BUILDING DEPT. AT THE CITY HALL |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
5 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
4 |
Status |
F |
Date |
2023-06-07 |
|
|
Cont ID |
|
| Sent By |
ckimmerl |
Date |
2023-06-07 |
Time |
13:55 |
Rev Time |
0.00 |
| Received By |
ckimmerl |
Date |
2023-06-07 |
Time |
13:47 |
Sent To |
|
|
| Notes |
| 2023-06-07 13:55:00 | 1. THE SUBMITTED COMMUNICATION FACILITY PLACEMENT | | | PERMIT - CITY RIGHTS-OF-WAY MUST BE APPROVED PRIOR TO | | | THIS PERMIT BEING APPROVED. THE PLANS INCLUDED WITH | | | THIS ELECTRICAL PERMIT MUST MATCH THE PLANS APPROVED | | | WITH THE AFOREMENTIONED PERMIT. | | | | | | 2. POLE & UNDERGROUND ELECTRIC BORE PIT AND HAND HOLE | | | SHOWN ON DRAWINGS TO CONFLICT WITH EXISTING GAS LINE | | | AND COMMUNICATIONS LINE PLEASE PROVIDE THE NECESSARY | | | PUBLIC UTILITY LETTERS GRANTING APPROVAL OF THIS | | | PROPOSED BORE PITS, UNDERGROUND ELECTRIC, AND POLE | | | LOCATION. | | | | | | 3. PROPOSED UNDERGROUND ELECTRIC RUNS THROUGH PRIVATE | | | PROPERTY, REQUIRES A UTILITY EASEMENT, OR REROUTE | | | THROUGH THE PUBLIC ROW. | | | | | | 4. PROVIDE ADDITIONAL DETAILS ENSURING THAT THE | | | UNDERGROUND ELECTRIC DOES NOT CONFLICT WITH PALM TREE | | | ROOT ZONE AT THE PROPOSED CONNECTION TO THE EXISTING | | | FPL TRANSFORMER. | | | | | | 5. THE POLE STEALTH DESIGN MEETS CITY STANDARDS. | | | | | | | | | NOTE: PRIOR TO BEGINNING THE PLACEMENT OF THE POLE, THE | | | UNDERGROUND FIBER, THE HANDHOLES, ETC. A RIGHT-OF-WAY | | | USE PERMIT MUST BE APPROVED BY THE CITY'S ENGINEERING | | | SERVICES DIVISION. | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
F |
Date |
2022-01-20 |
|
|
Cont ID |
|
| Sent By |
ckimmerl |
Date |
2022-01-20 |
Time |
11:00 |
Rev Time |
0.00 |
| Received By |
ckimmerl |
Date |
2022-01-20 |
Time |
10:59 |
Sent To |
|
|
| Notes |
| 2022-01-20 11:00:26 | 1. THE SUBMITTED COMMUNICATION FACILITY PLACEMENT | | | PERMIT - CITY RIGHTS-OF-WAY MUST BE APPROVED PRIOR TO | | | THIS PERMIT BEING APPROVED. THE PLANS INCLUDED WITH | | | THIS ELECTRICAL PERMIT MUST MATCH THE PLANS APPROVED | | | WITH THE AFOREMENTIONED PERMIT. | | | | | | 2. POLE & UNDERGROUND ELECTRIC BORE PIT AND HAND HOLE | | | SHOWN ON DRAWINGS TO CONFLICT WITH EXISTING GAS LINE | | | AND COMMUNICATIONS LINE PLEASE PROVIDE THE NECESSARY | | | PUBLIC UTILITY LETTERS GRANTING APPROVAL OF THIS | | | PROPOSED BORE PITS, UNDERGROUND ELECTRIC, AND POLE | | | LOCATION. | | | | | | 3. PROPOSED UNDERGROUND ELECTRIC RUNS THROUGH PRIVATE | | | PROPERTY, REQUIRES A UTILITY EASEMENT, OR REROUTE | | | THROUGH THE PUBLIC ROW. | | | | | | 4. PLEASE PROVIDE A TYPICAL CROSS-SECTION SHOWING THE | | | DEPTH OF THE UNDERGROUND ELECTRICAL COMPONENTS. | | | | | | 5. PROVIDE ADDITIONAL DETAILS ENSURING THAT THE | | | UNDERGROUND ELECTRIC DOES NOT CONFLICT WITH PALM TREE | | | ROOT ZONE AT THE PROPOSED CONNECTION TO THE EXISTING | | | FPL TRANSFORMER. | | | | | | 6. THE POLE STEALTH DESIGN MEETS CITY STANDARDS. | | | | | | | | | NOTE: PRIOR TO BEGINNING THE PLACEMENT OF THE POLE, THE | | | UNDERGROUND FIBER, THE HANDHOLES, ETC. A RIGHT-OF-WAY | | | USE PERMIT MUST BE APPROVED BY THE CITY'S ENGINEERING | | | SERVICES DIVISION. | | | | | | | | | CHRIS KIMMERLY @ (561) 822-1426 | | | [email protected] | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2021-05-26 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2021-05-26 |
Time |
11:50 |
Rev Time |
0.25 |
| Received By |
eschneid |
Date |
2021-05-26 |
Time |
09:59 |
Sent To |
|
|
| Notes |
| 2021-05-26 11:58:34 | FAILED | | | | | | 1) THE SUBMITTED COMMUNICATION FACILITY PLACEMENT | | | PERMIT - CITY RIGHTS-OF-WAY MUST BE APPROVED PRIOR TO | | | THIS PERMIT BEING APPROVED. THE PLANS INCLUDED WITH | | | THIS ELECTRICAL PERMIT MUST MATCH THE PLANS APPROVED | | | WITH THE AFOREMENTIONED PERMIT. SOME OF THE COMMENTS | | | BELOW ARE INCLUDED ON THE PLACEMENT PERMIT REVIEW AS | | | WELL AS WITH THIS PERMIT. | | | | | | 2) SHEET T1 LISTS THE SCOPE OF WORK INCLUDES THE | | | INSTALLATION OF AN ENCLOSURE CABINET. NONE OF THE PLANS | | | SHOW AN ENCLOSURE CABINET. PLEASE CLARIFY WHAT THIS | | | MEANS. THE CITY DOES NOT PERMIT FREESTANDING OR POLE | | | MOUNTED CABINETS. | | | | | | 3) THE SURVEY AND THE ENGINEERING PLANS THAT ARE USED | | | AS BASE PLANS TO SHOW THE AREA SURROUNDING THE POLE DO | | | NOT ACCURATELY DEPICT THE EXISTING CONDITIONS. | | | SPECIFICALLY, THE CURB LINE AND PLANTER LOCATIONS EAST | | | OF THE POLE ARE INCORRECTLY DEPICTED. THE SURVEY AND | | | PLANS NEED TO BE CORRECTED. | | | | | | 4) ONCE THE BASE CONDITIONS ARE ACCURATELY SHOWN, THE | | | PROPOSED POLE NEEDS TO BE SHOWN IN LINE WITH THE | | | EXISTING PALM TREES TO CREATE A UNIFORM STREETSCAPE | | | ALONG THE SOUTH SIDE OF FERN STREET. PLEASE NOTE THAT | | | STEALTH POLE SHOWN ON SHEET C3, ELEVATION AND EQUIPMENT | | | PLAN, HAS A 14-INCH DIAMETER. SCALING THE POLE ON THE | | | SURVEY AND SITE PLAN SHOW A SEVEN (7) INCH DIAMETER | | | POLE. THE SURVEY AND SITE PLAN NEED TO SHOW THE CORRECT | | | POLE SIZE AND DIMENSIONS FROM THE VARIOUS FEATURES | | | SHOWN. | | | | | | 5) THE UTILITY POWER PLAN INCLUDED SHOWS THE | | | UNDERGROUND POWER GOING UNDER THE 360 SOUTH ROSEMARY | | | BUILDING ON PRIVATE PROPERTY WHICH IS NOT PERMITTED. AN | | | ALTERNATIVE ROUTE THAT IS WITHIN THE PUBLIC | | | RIGHT-OF-WAY IS REQUIRED. | | | | | | NOTE: PRIOR TO BEGINNING THE PLACEMENT OF THE POLE, THE | | | UNDERGROUND FIBER, THE HANDHOLES, ETC. A RIGHT-OF-WAY | | | USE PERMIT MUST BE APPROVED BY THE CITY'S ENGINEERING | | | SERVICES DIVISION. | | | | | | CONTACT ERIC SCHNEIDER @ (561) 822-1446 | | | [email protected] | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2021-01-14 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2021-01-14 |
Time |
14:59 |
Rev Time |
0.25 |
| Received By |
eschneid |
Date |
2021-01-14 |
Time |
14:58 |
Sent To |
|
|
| Notes |
| 2021-01-14 15:24:26 | FAILED | | | | | | PROVIDE VERIFICATION THAT THE SITE HAS BEEN ISSUED A | | | COMMUNICATION FACILITY PLACEMENT PERMIT ? CITY | | | RIGHTS-OF-WAY AND A RIGHT-OF-WAY USE PERMIT FOR THE | | | PLACEMENT OF THE POLE WITHIN THE FERN STREET | | | RIGHT-OF-WAY. THE PLANS INCLUDED WITH THIS ELECTRICAL | | | PERMIT MUST MATCH THE PLANS APPROVED WITH THE | | | AFOREMENTIONED PERMITS. | | | | | | CONTACT ERIC SCHNEIDER @ (561) 822-1446 | | | [email protected] | | | | | | |
|
|