| Plan Review Stops For Permit 20121259 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2021-07-07 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2021-07-07 |
Time |
11:23 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2021-07-07 |
Time |
11:23 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2021-04-07 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2021-04-07 |
Time |
13:05 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2021-04-07 |
Time |
13:05 |
Sent To |
|
|
| Notes |
| 2021-04-07 13:13:49 | PLAN | | | REVIEW COMMENTS | | | | | | 1ST REVIEW: FBC SEVENTH EDITION (2020) | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY BUILDING | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) THE GENERATOR EXHAUST IS REQUIRED TO BE 10 FEET FROM | | | OPENINGS INTO A BUILDING. FBC-R303.5.1 INTAKE OPENINGS. | | | MECHANICAL AND GRAVITY OUTDOOR AIR INTAKE OPENINGS | | | SHALL BE LOCATED NOT LESS THAN 10 FEET (3048 MM) FROM | | | ANY HAZARDOUS OR NOXIOUS CONTAMINANT, SUCH AS VENTS, | | | CHIMNEYS, PLUMBING VENTS, STREETS, ALLEYS, PARKING LOTS | | | AND LOADING DOCKS. | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2021-04-07 |
|
|
Cont ID |
|
| Sent By |
fgiaquin |
Date |
2021-04-07 |
Time |
22:04 |
Rev Time |
0.00 |
| Received By |
fgiaquin |
Date |
2021-04-07 |
Time |
21:11 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
3 |
Status |
P |
Date |
2021-12-29 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2021-12-29 |
Time |
09:38 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2021-12-29 |
Time |
08:59 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
F |
Date |
2021-07-02 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2021-07-02 |
Time |
18:41 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2021-07-02 |
Time |
18:41 |
Sent To |
|
|
| Notes |
| 2021-07-02 18:41:20 | 1ST REVIEW FBC-2020 RES. | | | PERMIT- 20121259 | | | 7/2/2021 | | | | | | CODES IN EFFECT: | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION | | | 2020 | | | FBC FG- FLORIDA FUEL GAS CODE 7TH EDITION 2020 | | | NFPA 58 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) INDICATE ABOVE OR UNDERGROUND 250 GALLON LP TANK ON | | | THE RISER DRAWING AND SUBMIT MANUFACTURER'S | | | SPECIFICATIONS FOR THE TANK SHOWING IT HAS BEEN | | | DESIGNED, FABRICATED, TESTED AND MARKED (STAMPED) IN | | | ACCORDANCE WITH THE REGULATIONS AS REQUIRED BY THE | | | REGULATORY AGENCIES AND COMPLIANCE STANDARDS LISTED IN | | | SECTION 5.2.1.1 NFPA 58. IT APPEARS AN ABOVEGROUND TANK | | | IS PROPOSED BUT YOU HAVE ALSO SUBMITTED SACRIFICIAL | | | ANODE BAG SPECS FOR CATHODIC PROTECTION OF UNDERGROUND | | | TANKS- SECTIONS 5.2.1.11 & 6.6.6.1(I) NFPA 58. | | | | | | 2) THE SUBMITTED TANK ANCHORING SPECS ARE OUTDATED. THE | | | SPECS INDICATE COMPLIANCE WITH FBC- 6TH EDITION 2017 | | | AND ASCE 7-10 (EXP C), AND HAVE A NOTE INDICATING THEY | | | ARE VALID ONLY THROUGH 2020. PLEASE NOTE THE FBC -2020 | | | 7TH EDITION AND THE ASCE-7-16 ARE NOW IN EFFECT. PLEASE | | | SUBMIT UPDATED SPECS. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2021-04-15 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2021-04-15 |
Time |
13:32 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2021-04-15 |
Time |
13:22 |
Sent To |
|
|
| Notes |
| 2021-04-15 13:33:01 | 1ST REVIEW FBC-2020 RES. FUEL GAS | | | PERMIT- 20121259 | | | 4/15/2021 | | | | | | CODES IN EFFECT: | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION | | | 2020 | | | FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020 | | | FBC B- FLORIDA BUILDING CODE 7TH EDITION 2020 | | | FBC M- FLORIDA MECHANICAL CODE 7TH EDITION 2020 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION | | | 2020 | | | FBC FG- FLORIDA FUEL GAS CODE 7TH EDITION 2020 | | | FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) PROVIDE A COMPLETE GAS RISER DRAWING THAT INCLUDES | | | ALL NEW AND EXISTING GAS PIPING AND APPLIANCES AT THE | | | RESIDENCE- SECTION G2412.3 & G2412.4 FBC RES. REFER TO | | | FBC RES. CHAPTER 24 FUEL GAS- THE RISER SHALL INDICATE: | | | | | | A) TYPE OF GAS- NATURAL OR LP. | | | B) DELIVERY PRESSURE AT THE METER. | | | C) TOTAL BTU LOAD AND INDIVIDUAL APPLIANCE BTU LOADS. | | | D) TYPES AND SIZES OF PIPING. | | | E) TOTAL DEVELOPED LENGTH OF THE SYSTEM FROM THE METER | | | TO THE MOST REMOTE APPLIANCE OUTLET. | | | F) BRANCH AND CUT PIPE LENGTH MEASUREMENTS. | | | G) LOCATIONS OF REGULATORS, SHUTOFF VALVES, AND PIPE | | | UNIONS. | | | H) INLET AND OUTLET PRESSURES AT REGULATORS. | | | I) LOCATIONS AND TYPES OF PIPE SLEEVES. | | | K) PIPE SIZING TABLES. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2021-12-29 |
Time |
|
Rev Time |
0.00 |
| Received By |
aoliver |
Date |
2021-12-17 |
Time |
10:50 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2021-07-23 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2021-07-23 |
Time |
13:38 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2021-06-23 |
Time |
11:15 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2021-04-23 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-04-23 |
Time |
12:09 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-03-29 |
Time |
15:27 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
N |
Date |
2021-12-29 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2021-12-29 |
Time |
09:38 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2021-12-29 |
Time |
08:59 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
N |
Date |
2021-07-02 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2021-07-02 |
Time |
18:14 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2021-07-02 |
Time |
18:14 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
N |
Date |
2021-04-15 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2021-04-15 |
Time |
13:33 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2021-04-15 |
Time |
13:22 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
P |
Date |
2021-12-29 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2021-12-29 |
Time |
09:38 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2021-12-29 |
Time |
09:38 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2021-07-07 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2021-07-07 |
Time |
11:24 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2021-07-07 |
Time |
11:24 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2021-04-07 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2021-04-07 |
Time |
13:05 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2021-04-07 |
Time |
13:05 |
Sent To |
|
|
| Notes |
| 2021-04-07 13:17:12 | THE ENGINEER'S DIGITAL SIGNATURE ON THE GENERATOR PAD | | | DRAWINGS COULD NOT BE VERIFIED. ELECTRONICALLY | | | SUBMITTED DRAWINGS ARE REQUIRED TO HAVE THE ENGINEER'S | | | DIGITAL SIGNATURE ON THEM. YOU ALSO HAVE THE OPTION TO | | | SUBMIT THE SIGNED AND SEALED PAPER VERSION OF DRAWINGS. | | | AFTER THE ELECTRONIC PLANS HAVE BEEN APPROVED, YOU CAN | | | SUBMIT THE CORRESPONDING PAPER DRAWINGS AT THE BUILDING | | | DEPARTMENT TO BE VERIFIED. THE ENGINEER'S ORIGINAL | | | HANDWRITTEN SIGNATURE AND SEAL IS REQUIRED TO BE ON THE | | | DRAWINGS. NO PHOTOCOPY OR OTHER FACSIMILES OF THE | | | SIGNATURE ARE ACCEPTABLE. FS 471 & 61G15 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2021-07-22 |
|
|
Cont ID |
|
| Sent By |
kalexand |
Date |
2021-07-22 |
Time |
19:39 |
Rev Time |
0.00 |
| Received By |
kalexand |
Date |
2021-07-22 |
Time |
19:39 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2021-04-22 |
|
|
Cont ID |
|
| Sent By |
kalexand |
Date |
2021-04-22 |
Time |
09:13 |
Rev Time |
0.00 |
| Received By |
kalexand |
Date |
2021-04-22 |
Time |
09:13 |
Sent To |
I |
|
| Notes |
|
|