| Plan Review Stops For Permit 20121235 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2021-06-21 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-06-21 |
Time |
13:15 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-06-21 |
Time |
13:15 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2021-04-12 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-04-12 |
Time |
15:34 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-04-12 |
Time |
15:08 |
Sent To |
|
|
| Notes |
| 2021-04-12 15:31:57 | ADDING SECURITY GATES | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected]. | | | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 | | | AMENDMENTS | | | | | | CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107 | | | 1) OVERHEAD ROLL UP GATE DRAWINGS SHOWS A WIND PRESSURE | | | OF (-10 PSF) WHICH WILL NOT MEET THE REQUIRED WIND | | | PRESSURES FOR THAT OPENING. WILL THERE BE SIGNAGE | | | PROVIDED AS TO WHEN THE ROLL UP SCREEN DOOR WILL NEED | | | TO BE IN THE ROLLED UP POSITION? FBC 2002.7 (2) WHERE | | | SCREEN ENCLOSURES ARE DESIGNED IN ACCORDANCE WITH THE | | | SCREEN REMOVAL ALTERNATES OF THIS SECTION, REMOVABLE | | | SCREEN MAY CONSIST OF REMOVABLE PANELS, RETRACTABLE | | | PANELS, OR BY DESIGNATING SPECIFIC SCREEN PANELS IN THE | | | DESIGN IN WHICH THE SCREEN IS TO BE REMOVED BY CUTTING | | | THE SCREEN. REMOVABLE PANELS SHALL BE REMOVED, | | | RETRACTABLE PANELS SHALL BE PLACED IN THE RETRACTED | | | POSITION WITHOUT INCREASING THE LOAD ON THE AFFECTED | | | AREA. SCREEN DESIGNATED IN THE DESIGN TO BE CUT SHALL | | | BE COMPLETELY CUT WHEN WIND SPEEDS ARE FORECAST TO | | | EXCEED 75 MPH. (4) WHERE SCREEN ENCLOSURES ARE DESIGNED | | | IN ACCORDANCE WITH THE SCREEN REMOVAL ALTERNATES OF | | | THIS SECTION, RETRACTABLE SCREEN PANELS, REMOVABLE | | | SCREEN PANELS, AND SCREEN PANELS IDENTIFIED TO BE CUT | | | SHALL BE CLEARLY IDENTIFIED ON ADJACENT STRUCTURAL | | | MEMBERS WITH HIGHLY VISIBLE PERMANENT LABELS, AT EACH | | | PANEL, OR BY OTHER MEANS APPROVED BY THE LOCAL BUILDING | | | DEPARTMENT. | | | 2) TRELLIS WALL SYSTEM TO BE DEFERRED. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2021-01-15 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-01-15 |
Time |
15:09 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-01-15 |
Time |
13:14 |
Sent To |
|
|
| Notes |
| 2021-01-15 15:09:01 | ADDING SECURITY GATES | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected]. | | | CODE USED FOR REVIEW - 2017 FBC WITH WPB CHAPTER 1 | | | AMENDMENTS | | | | | | CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107 | | | 1) GATES AND OVERHEAD ROLLUP DOOR ARE SUBJECT TO WIND | | | LOADS PLEASE SHOW ON THE DRAWINGS ALL ATTACHMENTS FOR | | | SUCH OR PROVIDE MIAMI DADE OR FLORIDA STATE PRODUCT | | | APPROVALS WITH WIND DESIGN PRESSURES THAT MEET OR | | | EXCEED THE REQUIRED WIND PRESSURES FOR THE SPECIFIC | | | OPENING. FBC 1609 | | | 2) DRAWINGS SHOW CODE USED FOR DESIGN AS 2017 FBC - | | | CODE IN EFFECT HAS CHANGED TO 2020 FBC - PLEASE REVISE | | | THE DRAWINGS TO REFLECT THE CODE IN EFFECT. | | | 3) PROVIDE SIGNAGE FOR THE FOLLOWING FIX - FBC 1011.7.4 | | | ENCLOSURES UNDER EXTERIOR STAIRWAYS. | | | THERE SHALL NOT BE ENCLOSED USABLE SPACE UNDER EXTERIOR | | | EXIT STAIRWAYS UNLESS THE SPACE IS COMPLETELY ENCLOSED | | | IN 1-HOUR FIRE-RESISTANCE-RATED CONSTRUCTION. THE OPEN | | | SPACE UNDER EXTERIOR STAIRWAYS SHALL NOT BE USED FOR | | | ANY PURPOSE. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2021-04-12 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2021-04-12 |
Time |
13:35 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2021-04-12 |
Time |
12:06 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2021-01-19 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2021-01-19 |
Time |
16:39 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2021-01-19 |
Time |
16:36 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2021-01-19 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2021-01-19 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2021-01-19 |
Time |
11:04 |
Sent To |
|
|
| Notes |
| 2021-01-19 11:05:11 | FIRE PROVISO: | | | | | | | | | CARD READER INSTALLATION SHALL COMPLY WITH NFPA 101, CH | | | 7, MEANS OF EGRESS AND BE SUBMITTED UNDER SEPARATE | | | PERMIT AND SHOP DRAWINGS, INCLUDING EQUIPMENT | | | SPECIFICATION SHEETS, | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2021-06-23 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2021-06-23 |
Time |
17:07 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2021-06-02 |
Time |
12:18 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2021-04-23 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2021-04-23 |
Time |
08:19 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2021-04-06 |
Time |
10:06 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2021-01-19 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2021-01-19 |
Time |
16:39 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2021-01-04 |
Time |
15:30 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2021-04-12 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-04-12 |
Time |
15:37 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-04-12 |
Time |
15:37 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2021-01-15 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-01-15 |
Time |
15:13 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-01-15 |
Time |
15:13 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2021-06-22 |
|
|
Cont ID |
|
| Sent By |
aaponte |
Date |
2021-06-22 |
Time |
14:01 |
Rev Time |
0.00 |
| Received By |
aaponte |
Date |
2021-06-22 |
Time |
14:01 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2021-04-22 |
|
|
Cont ID |
|
| Sent By |
aaponte |
Date |
2021-04-22 |
Time |
18:11 |
Rev Time |
0.00 |
| Received By |
aaponte |
Date |
2021-04-22 |
Time |
18:11 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2021-01-07 |
|
|
Cont ID |
|
| Sent By |
elevesqu |
Date |
2021-01-07 |
Time |
10:32 |
Rev Time |
0.00 |
| Received By |
elevesqu |
Date |
2021-01-07 |
Time |
10:32 |
Sent To |
|
|
| Notes |
| 2021-01-07 10:32:09 | STAFF DOES NOT SUPPORT THE DESIGN OF THE FENCING AROUND | | | THE STAIRS. UNDERSTANDING SECURITY, THE FENCING NEEDS | | | TO BE ARCHITECTURALLY COMPATIBLE WITH THE DESIGN OF THE | | | STRUCTURE, PLEASE EVALUATE OTHER OPTIONS FOR | | | ARCHITECTURALLY ENHANCED FENCING. THE SCREENING FORM | | | THE UPPER FLOORS COULD BE CONTINUED DOWN FOR | | | CONSISTENCY AND SECURITY | | | | | | LOCATION OF BURIED MOUNTED CAR-HEIGHT PEDESTAL ON SOUTH | | | SIDE CANNOT ENCROACH INTO THE CITY ROW - PLEASE | | | RELOCATE ONTO PRIVATE PROPERTY | | | | | | PLEASE INDICATE TIMING OF GARAGE GATE CLOSURES - WILL | | | THESE ONLY BE CLOSED WHEN THE OFFICE IS CLOSED FOR | | | BUSINESS? | | | | | | THE LOCATION OF THE PROPOSED GATE APPURTENCES AT THE | | | SOUTH ENTRANCE APPEAR TO INTERFERE WITH THE SOUTHERN | | | MOST PARKING SPACE INSIDE THE GARAGE - PARKING SPACES | | | REQUIRED TO HAVE 8.6 WIDE, AND ADDITIONAL ONE FOOT IF | | | NEXT TO WALL. THIS PARKING SPACE MAY NEED TO BE REMOVED | | | | | | HOW WILL THE PROPOSED PARKING GARAGE SYSTEM WORK WITH | | | THE CEILLING MOUNTED PIPES AND EQUIPMENT WITHIN THE | | | GARAGE? | | | | | | | | | LIZ LEVESQUE, URBAN DESIGN PLANNER | | | 561 822 1426 | | | [email protected] | | | | | | |
|
|