Plan Review Details - Permit 20121148
Plan Review Stops For Permit 20121148
Review Stop AD ADDRESSING
Rev No 2 Status P Date 2021-01-05 Cont ID  
Sent By cpuell Date 2021-01-05 Time 11:40 Rev Time 0.00
Received By cpuell Date 2021-01-05 Time 11:40 Sent To  
Notes
2021-01-05 11:41:2574434316180100160 - 509 LILAC CT

Review Stop AD ADDRESSING
Rev No 1 Status F Date 2020-12-30 Cont ID  
Sent By cpuell Date 2020-12-30 Time 11:27 Rev Time 0.00
Received By cpuell Date 2020-12-30 Time 11:27 Sent To  
Notes
2020-12-30 11:27:44NEW ADDRESS TO BE ESTABLISHED FOR LOT. PLEASE CONTACT
 [email protected]

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2021-07-29 Cont ID  
Sent By jgomez Date 2021-07-29 Time 10:30 Rev Time 0.00
Received By jgomez Date 2021-07-29 Time 09:23 Sent To  
Notes
2021-07-29 10:34:30BUILDING AUDIT OK. JG.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2021-07-02 Cont ID  
Sent By jgomez Date 2021-07-01 Time 15:43 Rev Time 0.00
Received By jgomez Date 2021-07-01 Time 14:51 Sent To  
Notes
2021-07-01 15:44:17BUILDING AUDIT COMMENTS
 NEW SINGLE FAMILY RESIDENCE (R3).
 CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS.
 PERMIT #20121148
  
 1-ENERGY CALCULATIONS:
 D) BUILDER TO SIGN THE ENERGY PERFORMANCE LEVEL (EPL)
 DISPLAY CARD SUBMITTED. SEC. R405.4.3 FBC- ENERGY
 CONSERVATION.
 RESPONSE:
 REPEAT COMMENT. NOT ADDRESSED AT ALL.
  
 2- OK.
 3- OK
 4- OK.
 5- OK.
 6- OK.
 7- OK.
  
 WHEN RESUBMITTING, A TRANSMITTAL LETTER LISTING THE
 ORIGINAL REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF
 THE REVISION MADE, IDENTIFYING THE SHEET OR
 SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND WILL
 HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR
 ANTICIPATED COOPERATION.
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2021-02-09 Cont ID  
Sent By jgomez Date 2021-02-09 Time 17:53 Rev Time 0.00
Received By jgomez Date 2021-02-09 Time 16:33 Sent To  
Notes
2021-02-09 16:58:24BUILDING AUDIT COMMENTS
 NEW SINGLE FAMILY RESIDENCE (R3).
 CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS.
  
 PERMIT #20121148
  
 1-ENERGY CALCULATIONS:
 A)ENERGY CALCULATIONS FORM IS REQUIRED TO BE CERTIFIED
 AT THE BOTTOM OF THE FORM BY THE OWNER, THE OWNER'S
 ARCHITECT OR OTHER AUTHORIZED AGENT LEGALLY DESIGNED BY
 THE OWNER PRIOR TO RECEIVE THE PERMIT AS REQUIRED BY
 SEC. R103.1.1.2 FBC-ENERGY CONSERVATION, 7TH EDITION
 (2020).
  
 B)PROVIDE COMPLETE AND CORRECT INFORMATION ON TOP OF
 FORM. OWNER'S NAME DOESN'T MATCH OWNER'S NAME SHOWN ON
 THE PERMIT APPLICATION. REVISE AS REQUIRED. AND,
 PROVIDE THE BUILDER'S NAME. SEC. R101.5.1.1.2
 FBC-ENERGY CONSERVATION.
  
 C) BUILDER TO SIGN THE ENERGY PERFORMANCE LEVEL (EPL)
 DISPLAY CARD SUBMITTED. SEC. R405.4.3 FBC- ENERGY
 CONSERVATION.
  
 2- PROPOSED LAYOUT SHOWN ON THE SURVEY SUBMITTED AND
 PROPOSED LAYOUT SHOWN ON THE ARCHITECTURAL SITE PLAN
 SHEET SP-1 DON'T MATCH. REVISE ALL THE SETBACKS AS
 REQUIRED TO MATCH. SEC. 107.2.1 CITY AMENDMENTS.
 NOTE: ARCHITECTURAL SITE PLAN IS THE ONE THAT WAS
 APPROVED BY ZONING. ANY CHANGES WILL NEED TO BE RE-SENT
 TO ZONING FOR REVIEW/APPROVAL.
  
 3- DRAINAGE PLAN DRAWING C-1 SUBMITTED:
 A) COORDINATE WITH ITEM #2 ABOVE TO AVOID
 CONFLICTS/DELAYS. SEC. 107.2.1 CITY AMENDMENTS.
  
 B) OWNER INFORMATION, ZONING INFORMATION (38 -LAKE
 WORTH BEACH?) IS INCORRECT. REVISE AS REQUIRED. SEC.
 107.2.1 CITY AMENDMENTS.
  
 C) DRAINAGE PLAN SHOULD BE UPLOADED TO PROJECTDOX IN
 THE "DRAWINGS" FOLDER NO IN THE "SUPPORTING DOCUMENTS"
 FOLDER AS REQUIRED BY CITY GUIDELINES FOR DIGITAL PLAN
 REVIEW. SEC. 107.2.1.3 CITY AMENDMENTS.
 NOTE: PLEASE COORDINATE WITH PERMIT LIBRARIAN TO MOVE
 THIS DRAWING TO THE DRAWINGS FOLDER SO THEY CAN BE
 VERSIONED WITH THE REVISED DRAWING.
  
 4- SURVEY SUBMITTED:
 A)SURVEY SHOULD BE UPLOADED TO PROJECTDOX IN THE
 "DRAWINGS" FOLDER NO IN THE "SUPPORTING DOCUMENTS"
 FOLDER AS REQUIRED BY CITY GUIDELINES FOR DIGITAL PLAN
 REVIEW. SEC. 107.2.1.3 CITY AMENDMENTS.
 NOTE: PLEASE COORDINATE WITH PERMIT LIBRARIAN TO MOVE
 THIS DRAWING TO THE DRAWINGS FOLDER.
  
 B) CLARIFY WHY THE SURVEY SUBMITTED WAS NAMED "LILIAC
 COURT-SITE PLAN-DRIVEWAY DIST SITE PLAN" INSTEAD OF
 SURVEY OR BOUNDARY SURVEY (CONSTRUCTION LAYOUT) AS
 DESCRIBED BY THE SURVEYOR ON SURVEY SUBMITTED.
 CLARIFY/REVISE AS REQUIRED. PROPER NAMING OF THE
 DRAWINGS/DOCUMENTS SUBMITTED HELPS FOR PROPER RECORDS
 RETENTION MANAGEMENT. SEC. 107.2.1.3 CITY AMENDMENTS.
  
 5- TYPICAL WALL SECTION ON SHEET A-3 SPECIFIES 10"
 FOOTING DEPTH. ACCORDING TO SEC. R403.1.4
 FBC-RESIDENTIAL EXTERIOR FOOTING REQUIRES 12" MIN.
 DEPTH. REVISE AS REQUIRED.
  
 6- ROOF FRAMING PLAN ON SHEET S-2:
 A) MISSING SPECIFICATIONS FOR CONNECTORS AT THE HIP
 ENDS ON THE SOUTH SIDE. SEC. R301.1 FBC-RESIDENTIAL.
  
 B) CLARIFY WHY THE TRUSS CONNECTOR SPECIFIED FOR THE
 HIP GIRDER TRUSS ON THE SOUTH SIDE IS THE SAME
 CONNECTOR SPECIFIED FOR ALL OTHER ROOF TRUSSES.
 TYPICALLY, HIP GIRDER TRUSSES SUPPORT HIGHER UPLIFT
 LOADS. HIP GIRDER TRUSS ON THE NORTH SIDE OF THE SAME
 ROOF FRAMING PLAN SPECIFY A DIFFERENT CONNECTOR.
 CLARIFY REVISE AS REQUIRED. SEC. 107.2.1.2 CITY
 AMENDMENTS. SEC. R301.1 FBC-RESIDENTIAL.
  
 7- EXTERIOR DOORS:
 TYPE OF EXTERIOR DOORS TO BE INSTALLED IS NOT CLEAR.
 CLARIFY IF USING THERMATRU FIBERGLASS DOORS OR ALUMINUM
 FRENCH DOORS. BOTH PRODUCT APPROVALS WERE SUBMITTED.
 EITHER ONE CAN BE USED, BUT NEED TO CONFIRM WHICH ONE
 IS GOING TO BE INSTALLED. IF USING THE ALUMINUM FRENCH
 DOORS, THEN THE ENERGY CALCULATIONS NEED TO BE REVISED
 ACCORDINGLY. REVISE/CLARIFY AS REQUIRED.
 SEC. 107.2.1 CITY AMENDMENTS.
  
 NOTE: ALSO CLARIFY WHY SUBMITTING PRODUCT APPROVAL FOR
 OVERHEAD GARAGE DOOR. THERE IS NO GARAGE IN THIS HOUSE.
  
  
 WHEN RESUBMITTING, A TRANSMITTAL LETTER LISTING THE
 ORIGINAL REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF
 THE REVISION MADE, IDENTIFYING THE SHEET OR
 SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND WILL
 HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR
 ANTICIPATED COOPERATION.
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2021-02-08 Cont ID  
Sent By jleahy Date 2021-02-08 Time 16:38 Rev Time 0.00
Received By jleahy Date 2021-02-08 Time 13:09 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2021-07-29 Cont ID  
Sent By lmarchan Date 2021-07-29 Time 14:22 Rev Time 0.00
Received By lmarchan Date 2021-07-27 Time 11:50 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2021-07-02 Cont ID  
Sent By jgomez Date 2021-07-02 Time 16:53 Rev Time 0.00
Received By jgomez Date 2021-06-23 Time 08:00 Sent To I
Notes
2021-06-29 08:04:37TO BLDG AUDIT
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2021-06-29 Cont ID  
Sent By shill Date 2021-06-22 Time 08:00 Rev Time 0.00
Received By shill Date 2021-06-15 Time 16:54 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2021-06-01 Cont ID  
Sent By shill Date 2021-06-01 Time 16:13 Rev Time 0.00
Received By shill Date 2021-05-13 Time 10:20 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2021-02-10 Cont ID  
Sent By shill Date 2021-02-10 Time 17:13 Rev Time 0.00
Received By shill Date 2021-01-21 Time 11:27 Sent To  
Notes
2021-02-10 17:14:00REMOVED FROM BUILDING AUDIT; ARCH SITE PLAN DOES NOT
 MATCH SURVEY
  
2021-01-22 13:04:50ROUTED FOR BUILDING AUDIT
  

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status P Date 2021-08-16 Cont ID  
Sent By lmarchan Date 2021-08-16 Time 12:15 Rev Time 0.00
Received By lmarchan Date 2021-07-29 Time 14:23 Sent To  
Notes
2021-08-16 10:34:41RECEIPT MU-2021-001364 - $9968.61 PAID
2021-07-29 14:23:137/29/21 EMAILED IMPACT FOR REVIEW. LEM

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2021-02-13 Cont ID  
Sent By shill Date 2021-02-13 Time 14:58 Rev Time  
Received By shill Date 2021-01-04 Time 14:51 Sent To  
Notes
2021-02-13 14:59:17THIS SHOULD BE SENT TO IMPACT AFTER ZONING REVIEW &
 BUILDING AUDIT PASS
2021-01-04 14:51:301/4/21 EMAILED IMPACT OFFICE FOR REVIEW. LEM

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2021-07-02 Cont ID  
Sent By medwards Date 2021-02-09 Time 07:01 Rev Time 0.00
Received By medwards Date 2021-02-09 Time 06:32 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2021-07-01 Cont ID  
Sent By jgomez Date 2021-07-01 Time 16:57 Rev Time 0.00
Received By jgomez Date 2021-07-01 Time 16:57 Sent To  
Notes
2021-07-01 16:58:14AUDIT ONLY. JG.

Review Stop PRIVATEPRV PRIVATE PROVIDER DOCUMENTS
Rev No 3 Status P Date 2021-08-16 Cont ID  
Sent By rgathrig Date 2021-08-16 Time 09:34 Rev Time 0.00
Received By rgathrig Date 2021-08-16 Time 09:34 Sent To  
Notes
2021-08-16 09:35:14PRIVATE PROVIDER REVIEW APPROVED
 NEW AFFIDAVIT SUBMITTED
 RICHARD GATHRIGHT

Review Stop PRIVATEPRV PRIVATE PROVIDER DOCUMENTS
Rev No 2 Status F Date 2021-07-29 Cont ID  
Sent By rgathrig Date 2021-07-29 Time 14:03 Rev Time 0.00
Received By rgathrig Date 2021-07-29 Time 14:03 Sent To  
Notes
2021-07-29 14:13:00PRIVATE PROVIDER REVIEW FAILED
 1. AFFIDAVIT OF CODE COMPLIANCE FOR THE PLAN REVIEW
 DOES NOT MATCH THE PAGE DATES SUBMITTED FOR PERMIT.
 2. STEVE BRUH DOCUMENTS ARE ALL DATES 10/18/2020 WITH
 REVISION DATES OF 3/18/2021 FOR SHEETS A3 AND S2.
 3. PRODUCT APPROVAL FOR THERMATRU DOORS ONLY HAS THE
 COVER SHEET OF AN 8-PAGE DOCUMENT AND DOES NOT MATCH
 THE DOCUMENT NUMBER ON STEVE BRUH?S A1 PAGE. ARCHITECT
 SPECIFIES APPROVAL 8871.8, SUBMITTED WAS 8871.5
  
 RICHARD GATHRIGHT
 JULY 29, 2021
  

Review Stop PRIVATEPRV PRIVATE PROVIDER DOCUMENTS
Rev No 1 Status F Date 2021-07-02 Cont ID  
Sent By rgathrig Date 2021-07-02 Time 13:53 Rev Time 0.00
Received By rgathrig Date 2021-07-02 Time 13:52 Sent To  
Notes
2021-07-02 13:55:11PP REVIEW FAILED . WILL NEED TO RESUBMIT AFFIDAVITS
 WHEN AUDITS ARE APPROVED
  
 RICHARD GATHRIGHT
  
2021-01-05 13:38:54CALCULATED VALUE BASED ON ICC BUILDING VALUATION
 TABLES,
 1 STORY RESIDENTIAL. TYPE IIIB CONSTRUCTION.
 UNDER AIR - 1267SF X $136.62 = $173,098.00
 NO GARAGE
 UTILITY - 13SF X $60.42 = $ 785.00
 TOTAL CALCULATED VALUE - $173,883.00.
 CT

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status P Date 2021-02-09 Cont ID  
Sent By jgomez Date 2021-02-09 Time 17:52 Rev Time 0.00
Received By jgomez Date 2021-02-09 Time 17:52 Sent To  
Notes
2021-02-09 17:52:581- SHINGLES NOA 20-0527.05.
 2- SHINGLES HIP & RIDGE NOA 19-0109.03.

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2021-07-01 Cont ID  
Sent By jgomez Date 2021-07-01 Time 17:02 Rev Time 0.00
Received By jgomez Date 2021-07-01 Time 17:02 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2021-02-09 Cont ID  
Sent By medwards Date 2021-02-09 Time 07:03 Rev Time 0.00
Received By jgomez Date 2021-02-09 Time 07:03 Sent To  
Notes
2021-02-09 17:07:051- DRAINAGE PLAN DRAWING C-1 SUBMITTED:
 JAMES MILLS, P.E. DIGITAL SIGNATURE HAS A SELF
 CERTIFIED DIGITAL SIGNATURE. FBPE DOES NOT ALLOW USE OF
 SELF CERTIFIED SIGNATURES. PLEASE OBTAIN A DIGITAL
 SIGNATURE ISSUED BY A CERTIFICATE AUTHORITY (OFTEN
 CALLED AS 3RD PARTY CERTIFICATION).
 FAC 61G15-23.004
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]
  

Review Stop Z ZONING
Rev No 4 Status P Date 2021-06-22 Cont ID  
Sent By ajones Date 2021-06-22 Time 15:30 Rev Time 0.00
Received By ajones Date 2021-06-22 Time 15:30 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 3 Status F Date 2021-06-01 Cont ID  
Sent By ajones Date 2021-06-01 Time 14:26 Rev Time 0.00
Received By ajones Date 2021-06-01 Time 14:26 Sent To  
Notes
2021-06-01 14:27:466/1/21- FAILED. REPEAT COMMENT THE SURVEY AND THE SITE
 PLAN SETBACKS DO NOT MATCH.
  
 ANGELLA VANN
 561-822-1441
 [email protected]

Review Stop Z ZONING
Rev No 2 Status F Date 2021-02-10 Cont ID  
Sent By ajones Date 2021-02-10 Time 17:02 Rev Time 0.00
Received By ajones Date 2021-02-10 Time 17:02 Sent To  
Notes
2021-02-10 17:05:262/10/11- FAILED- THE SETBACKS ON THE SURVEY AND THE
 SITE PLAN DO NOT MATCH. PLEASE INDICATE WHICH ONE
 CORRECT.
  
 ANGELLA VANN
 [email protected]
 561-822-1441

Review Stop Z ZONING
Rev No 1 Status P Date 2021-01-21 Cont ID  
Sent By avann Date 2021-01-21 Time 16:19 Rev Time 0.00
Received By ajones Date 2021-01-21 Time 16:19 Sent To  
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved