Plan Review Details - Permit 20120867
Plan Review Stops For Permit 20120867
Review Stop E ELECTRICAL
Rev No 2 Status P Date 2021-02-12 Cont ID  
Sent By fgiaquin Date 2021-02-12 Time 22:37 Rev Time 0.00
Received By fgiaquin Date 2021-02-12 Time 21:02 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2021-01-07 Cont ID  
Sent By fgiaquin Date 2021-01-07 Time 22:39 Rev Time 0.00
Received By fgiaquin Date 2021-01-07 Time 21:46 Sent To  
Notes
2021-01-07 22:39:06SATISFY FIRE COMMENTS

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2021-02-08 Cont ID  
Sent By pleduc Date 2021-02-08 Time   Rev Time 0.00
Received By pleduc Date 2021-02-05 Time 14:02 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2020-12-30 Cont ID  
Sent By pleduc Date 2020-12-30 Time   Rev Time 0.00
Received By pleduc Date 2020-12-30 Time 09:53 Sent To  
Notes
2020-12-30 09:54:02THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE
 MARSHAL, WITH THE FOLLOWING COMMENTS:
  
  
 1) THERE ARE INDICATIONS THROUGHOUT THE OCCUPANCY OF
 FIRE ALARM PULL STATIONS.
  
 IN AN EFFORT TO REDUCE THE POTENTIAL OF FALSE ALARMS
 REDUCE THE AMOUNT AND LOCATION OF PULL STATION PER NFPA
 101, CH 28 & CH 9.
  
 28.3.4 DETECTION, ALARM, AND COMMUNICATIONS SYSTEMS.
 28.3.4.1 GENERAL. A FIRE ALARM SYSTEM IN ACCORDANCE
 WITH SECTION
 9.6, EXCEPT AS MODIFIED BY 28.3.4.2 THROUGH 28.3.4.6,
 SHALL BE
 PROVIDED.
 28.3.4.2 INITIATION. THE REQUIRED FIRE ALARM SYSTEM
 SHALL BE
 INITIATED BY EACH OF THE FOLLOWING:
 (1) MANUAL MEANS IN ACCORDANCE WITH 9.6.2
 (2) MANUAL FIRE ALARM BOX LOCATED AT THE HOTEL DESK OR
 OTHER
 CONVENIENT CENTRAL CONTROL POINT UNDER CONTINUOUS
 SUPERVISION BY RESPONSIBLE EMPLOYEES
 (3) REQUIRED AUTOMATIC SPRINKLER SYSTEM
 (4) REQUIRED AUTOMATIC DETECTION SYSTEM OTHER THAN
 SLEEPING
 ROOM SMOKE DETECTORS
  
 9.6.2 SIGNAL INITIATION.
 9.6.2.1 WHERE REQUIRED BY OTHER SECTIONS OF THIS CODE,
 ACTUATION
 OF THE FIRE ALARM SYSTEM SHALL OCCUR BY ANY OR ALL OF
 THE FOLLOWING
 MEANS OF INITIATION BUT SHALL NOT BE LIMITED TO SUCH
 MEANS:
 (1) MANUAL FIRE ALARM INITIATION
 (2) AUTOMATIC DETECTION
 (3) EXTINGUISHING SYSTEM OPERATION
  
 9.6.2.6* FOR FIRE ALARM SYSTEMS USING AUTOMATIC FIRE
 DETECTION OR
 WATERFLOW DETECTION DEVICES TO INITIATE THE FIRE ALARM
 SYSTEM IN
 ACCORDANCE WITH CHAPTERS 11 THROUGH 43, NOT LESS THAN
 ONE MANUAL
 FIRE ALARM BOX, LOCATED AS REQUIRED BY THE AUTHORITY
 HAVING
 JURISDICTION, SHALL BE PROVIDED TO INITIATE A FIRE
 ALARM SIGNAL.
  
 THE SUBMITTED PLAN HAS BEEN MARKED-UP TO REMOVE PULL
 STATIONS.
  
 PLEASE REVIEW AND ADJUST, UNLESS THE OWNER HAS
 SPECIFIACCLY REQUESTED TO HAVE THEM AT THESE LOCATIONS.
  
  
  
  
 2) THERE ARE INDICATIONS THROUGHOUT THE OCCUPANCY OF
 FIRE ALARM PULL STATIONS.
  
 IN AN EFFORT TO REDUCE THE POTENTIAL OF FALSE ALARMS
 REDUCE THE AMOUNT AND LOCATION OF PULL STATION PER NFPA
 101, CH 28 & CH 9.
  
 28.3.4.4 DETECTION. A CORRIDOR SMOKE DETECTION SYSTEM
 IN
 ACCORDANCE WITH SECTION 9.6 SHALL BE PROVIDED IN
 BUILDINGS OTHER
 THAN THOSE PROTECTED THROUGHOUT BY AN APPROVED,
 SUPERVISED
 AUTOMATIC SPRINKLER SYSTEM IN ACCORDANCE WITH 28.3.5.3.
  
 9.6.2.9 WHERE A TOTAL (COMPLETE) COVERAGE SMOKE
 DETECTION
 SYSTEM IS REQUIRED BY ANOTHER SECTION OF THIS CODE,
 AUTOMATIC
 DETECTION OF SMOKE IN ACCORDANCE WITH NFPA 72, NATIONAL
 FIRE
 ALARM AND SIGNALING CODE, SHALL BE PROVIDED IN ALL
 OCCUPIABLE
 AREAS IN ENVIRONMENTS THAT ARE SUITABLE FOR PROPER
 SMOKE DETECTOR
 OPERATION.
  
 SMOKE DETECTION IS NOT REQUIRED THROUGHOUT THE
 OCCUPANCY DUE TO THE FIRE SPRINKLER SYSTEM.
  
 PLEASE REVIEW AND ADJUST WHERE NOT REQUIRED, UNLESS THE
 OWNER HAS SPECIFIACCLY REQUESTED TO HAVE THEM AT THE
 NOTED LOCATIONS.
  
  
 3) THERE ARE INDICATIONS OF SMOKE DETECTORS IN EACH
 ROOM/SUITE.
  
 PER NFPA 101, CH 28
  
 28.3.4.5* SMOKE ALARMS. SMOKE ALARMS SHALL BE INSTALLED
 IN
 ACCORDANCE WITH 9.6.2.10 IN EVERY GUEST ROOM AND EVERY
 LIVING
 AREA AND SLEEPING ROOM WITHIN A GUEST SUITE.
  
 9.6.2.10.6 SYSTEM SMOKE DETECTORS IN ACCORDANCE WITH
 NFPA 72,
 NATIONAL FIRE ALARM AND SIGNALING CODE, AND ARRANGED TO
 FUNCTION IN THE SAME MANNER AS SINGLE-STATION OR
 MULTIPLE-STATION
 SMOKE ALARMS SHALL BE PERMITTED IN LIEU OF SMOKE
 ALARMS.
  
 9.6.2.10.8* IN NEW CONSTRUCTION, WHERE TWO OR MORE
 SMOKE ALARMS
 ARE REQUIRED WITHIN A DWELLING UNIT, SUITE OF ROOMS, OR
 SIMILAR AREA,
 THEY SHALL BE ARRANGED SO THAT OPERATION OF ANY SMOKE
 ALARM SHALL
 CAUSE THE ALARM IN ALL SMOKE ALARMS WITHIN THE DWELLING
 UNIT, SUITE
 OF ROOMS, OR SIMILAR AREA TO SOUND, UNLESS OTHERWISE
 PERMITTED BY
 ONE OF THE FOLLOWING:
 (1) THE REQUIREMENT OF 9.6.2.10.8 SHALL NOT APPLY WHERE
 PERMITTED BY ANOTHER SECTION OF THIS CODE.
 (2) THE REQUIREMENT OF 9.6.2.10.8 SHALL NOT APPLY TO
 CONFIGURATIONS THAT PROVIDE EQUIVALENT DISTRIBUTION OF
 THE
 ALARM SIGNAL.
 9.6.2.10.9 THE ALARMS DESCRIBED IN 9.6.2.10.8 SHALL
 SOUND ONLY
 WITHIN AN INDIVIDUAL DWELLING UNIT, SUITE OF ROOMS, OR
 SIMILAR AREA
 AND SHALL NOT ACTUATE THE BUILDING FIRE ALARM SYSTEM,
 UNLESS
 OTHERWISE PERMITTED BY THE AUTHORITY HAVING
 JURISDICTION.
 9.6.2.10.10 SMOKE ALARMS SHALL BE PERMITTED TO BE
 CONNECTED TO
 THE BUILDING FIRE ALARM SYSTEM FOR THE PURPOSE OF
 ANNUNCIATION IN
 ACCORDANCE WITH NFPA 72.
  
 PLEASE REVIEW AND PROVIDE DETAILS IN COMPLIANCE WITH
 THE CODE.
  
  
  
 4) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET
 REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE
 ABOVE.
  
  
 5) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE
 RE-SUBMITTAL OF THE ABOVE.
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status F Date 2021-02-12 Cont ID  
Sent By fgiaquin Date 2021-02-12 Time 22:37 Rev Time 0.00
Received By fgiaquin Date 2021-02-04 Time 10:40 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2021-01-07 Cont ID  
Sent By fgiaquin Date 2021-01-07 Time 22:39 Rev Time 0.00
Received By fgiaquin Date 2020-12-29 Time 15:34 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2021-02-16 Cont ID  
Sent By medwards Date 2021-02-16 Time 13:04 Rev Time 0.00
Received By medwards Date 2021-02-16 Time 13:04 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2021-01-07 Cont ID  
Sent By medwards Date 2021-01-07 Time 06:31 Rev Time 0.00
Received By medwards Date 2021-01-07 Time 06:02 Sent To  
Notes
2021-01-07 06:33:02SEE FIRE REVIEWER'S COMMENTS.
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2021-02-12 Cont ID  
Sent By fgiaquin Date 2021-02-12 Time 22:37 Rev Time 0.00
Received By fgiaquin Date 2021-02-12 Time 22:37 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2020-12-30 Cont ID  
Sent By medwards Date 2020-12-30 Time 08:58 Rev Time 0.00
Received By medwards Date 2020-12-30 Time 08:58 Sent To  
Notes
2020-12-30 08:59:23ORIGINAL SIGNED AND SEALED PAPER DRAWINGS ROUTED TO
 STORAGE. ME