| 2020-12-16 14:38:04 | PLAN REVIEW / BUILDING |
| | |
| | CHRISTOPHER S. THROOP, C.B.O. |
| | PLANS EXAMINER BUILDING - PX3169 |
| | PLANS EXAMINER 1&2 FAMILY - SFP306 |
| | CONSTRUCTION SERVICES DIVISION |
| | TEL: 561-805-6726 |
| | FAX: 561-805-6676 |
| | E-MAIL: [email protected] |
| | |
| | CODES IN EFFECT: |
| | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST |
| | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, |
| | CHAPTER 1 ADMINISTRATION |
| | 2014 NEC |
| | |
| | 1ST REVIEW |
| | |
| | RESULTS: DENIED |
| | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT |
| | |
| | RE: COMM-REV |
| | |
| | SOW: INSTALLATION OF FLOORING - LVT |
| | |
| | DESCRIPTION OF WORK ON REV FORM "PERMIT DID NOT HAVE |
| | THE PRODUCT APPROVAL FOR VINYL LAMINATE LIFE PROOF |
| | PRODUCT TESTING" |
| | |
| | PRODUCT APPROVALS ARE NOT REQUIRED FOR FLOORING |
| | INSTALLATIONS. |
| | |
| | PERMIT 20111146 INCLUDED ASTM TEST REPORTS E-90, E-492 |
| | FOR 12MM LAMINATED WOOD OVER PRO-FLEX LV-200 AND E-84 |
| | FOR PRO-FLEX LV-200 UNDERLAYMENT. |
| | |
| | 1. PROVIDE THE FOLLOWING ASTM TEST REPORTS FOR YOUR |
| | PROPOSED UNDERLAYMENT: |
| | ASTM E-90 |
| | ASTM E-492 |
| | ASTM E-84 |
| | |
| | NOTE: ASTM TEST REPORTS ARE REQUIRED - MANUFACTURER |
| | SPEC SHEETS ARE NOT ACCEPTABLE DUE TO DISCREPANCIES |
| | BETWEEN SPEC SHEETS/BROCHURES AND TEST REPORTS FOR SOME |
| | MANUFACTURERS (NOT NECESSARILY THE MANUFACTURER |
| | SELECTED; THIS IS A GENERAL COMMENT) |
| | |
| | FBC 1207.2 AIR-BORNE SOUND. ASTM E ? 90-04 |
| | FBC 1207.3 STRUCTURE-BORNE SOUND. ASTM E ? 492-09 |
| | FBC 603.1 FLAME SPREAD; SEC 803.1.1, PROVIDE TEST DATA |
| | IN ACCORDANCE WITH ASTM E 84 OR UL 723 |
| | |
| | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED |
| | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. |
| | |
| | |
| | |
| | |
| | |
| | |