Plan Review Details - Permit 20120687
Plan Review Stops For Permit 20120687
Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 1 Status N Date 2020-12-23 Cont ID  
Sent By cthroop Date 2020-12-23 Time 13:16 Rev Time 0.00
Received By cthroop Date 2020-12-23 Time 13:16 Sent To  
Notes
2020-12-23 13:16:58SEE ASBESTOS COMMENTS UNDER BUILDING REVIEW. CT

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2021-06-21 Cont ID  
Sent By cthroop Date 2021-06-21 Time 08:49 Rev Time 0.00
Received By cthroop Date 2021-06-21 Time 08:39 Sent To  
Notes
2021-06-21 08:53:26 
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2021-04-09 Cont ID  
Sent By cthroop Date 2021-04-09 Time 15:23 Rev Time 0.00
Received By cthroop Date 2021-04-09 Time 14:55 Sent To  
Notes
2021-04-09 15:27:51PLAN REVIEW BUILDING DEMO
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
  
 CHRISTOPHER S. THROOP, C.B.O.
 BUILDING PLANS EXAMINER, PX3169
 1&2 FAMILY PLANS EXAMINER, SFP306
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED
 SATISFACTORILY ARE MARKED AS CORRECTED.
 PREVIOUS COMMENTS THAT HAVE NOT BEEN ADDRESSED
 SATISFACTORILY MAY HAVE ADDITIONAL COMMENTS IN
 PARENTHESES. ANY NEW COMMENT WILL BE LISTED AFTER
 PREVIOUS COMMENTS.
  
  
 DEMO CHECKLIST
  
 THE FOLLOWING ITEMS ARE REQUIRED PRIOR TO ISSUANCE OF A
 DEMO PERMIT PER FLORIDA BUILDING CODE, BUILDING 3303:
  
 1. FPL - CORRECTED
  
 2. FPU - CORRECTED
  
 3. UTILITY RELEASE - CITY OF WEST PALM BEACH WATER
 DEPARTMENT, REQUEST FOR METER PULL, ON THEIR FORM
 "DEMOLITION APPLICATION" (NOT ADDRESSED)
  
 HTTP://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/B
 UILDING-PERMIT-FORMS
  
 IF A HYDRANT METER OR BACKFLOW PREVENTER IS DESIRED,
 THEN A PARTIAL RELEASE WILL BE NOTED ON THEIR FORM.
  
 4. SEWER LATERAL CAPPING PERMIT IS REQUIRED (SUBMIT
 APPLICATION TO BUILDING DIVISION); SCHEDULE A FINAL
 PLUMBING #703. (NO FINAL SCHEDULED)
  
 5. EXTERMINATION LETTER - LETTER FROM A LICENSED PEST
 CONTROL COMPANY STATING THAT DEMOLITION ADDRESS HAS
 BEEN INSPECTED AND/OR TREATED FOR RODENTS. (2 LETTER
 SUBMITTED FOR REVIW.
 THEY BOTH HAVE 835 BELVEDERE. THIS PROJECT IS LOCATED
 AT 875 BELVEDERE. -
  
 6. COMPLETE THE DEMO DEBRIS FORM: - (INCOMPLETE)
  
 7. SURVEY - CORRECTED
  
 8.STORM WATER PREVENTION - CORRECTED
  
 9.ASBESTOS - CORRECTED
  
  
  
  
  
  
  
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2020-12-23 Cont ID  
Sent By cthroop Date 2020-12-23 Time 13:24 Rev Time 0.00
Received By cthroop Date 2020-12-23 Time 13:15 Sent To  
Notes
2020-12-23 13:25:55PLAN REVIEW BUILDING DEMO
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
  
 CHRISTOPHER S. THROOP, C.B.O.
 BUILDING PLANS EXAMINER, PX3169
 1&2 FAMILY PLANS EXAMINER, SFP306
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
 DEMO CHECKLIST
  
 THE FOLLOWING ITEMS ARE REQUIRED PRIOR TO ISSUANCE OF A
 DEMO PERMIT PER FLORIDA BUILDING CODE, BUILDING 3303:
  
 1. UTILITY RELEASE - FLORIDA POWER & LIGHT (ELECTRIC)
 RELEASE OF SERVICE CONFIRMATION
  
 2. UTILITY RELEASE - FLORIDA PUBLIC UTILITIES (GAS)
 RELEASE OF SERVICE CONFIRMATION
  
 3. UTILITY RELEASE - CITY OF WEST PALM BEACH WATER
 DEPARTMENT, REQUEST FOR METER PULL, ON THEIR FORM
 "DEMOLITION APPLICATION"
  
 HTTP://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/B
 UILDING-PERMIT-FORMS
  
 IF A HYDRANT METER OR BACKFLOW PREVENTER IS DESIRED,
 THEN A PARTIAL RELEASE WILL BE NOTED ON THEIR FORM.
  
 FAX THE COMPLETED "DEMOLITION APPLICATION" FORM TO
 561-822-2183. AFTER THEY FAX THE RELEASE TO YOU, SEND A
 COPY VIA EMAIL TO [email protected] WITH THE PERMIT
 NUMBER IN THE SUBJECT LINE.
  
 4. SEWER LATERAL CAPPING PERMIT IS REQUIRED (SUBMIT
 APPLICATION TO BUILDING DIVISION); SCHEDULE A FINAL
 PLUMBING #703.
  
 5. EXTERMINATION LETTER - LETTER FROM A LICENSED PEST
 CONTROL COMPANY STATING THAT DEMOLITION ADDRESS HAS
 BEEN INSPECTED AND/OR TREATED FOR RODENTS.
  
 6. COMPLETE THE DEMO DEBRIS FORM:
  
 HTTP://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/B
 UILDING-PERMIT-FORMS
  
 7. PROVIDE A SITE PLAN OR SURVEY SHOWING LOCATION OF
 THE STRUCTURE(S) TO BE DEMOLISHED, FBC 107.
  
 8.PROVIDE A STORMWATER POLLUTION PREVENTION PLAN.
 YOU MAY USE THE SURVEY. SHOW SILT FENCEING OR OTHER
 APPROVED METHODS
  
 9.ASBESTOS
  
 PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE
 CONTRACTOR, ON LETTERHEAD, STATING THAT:
  
 ?THE INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM
 COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH
 COUNTY WILL BE FOLLOWED, AND THAT NOTIFICATION WILL BE
 GIVEN TIMELY?.
  
 ADDITIONAL INFORMATION REGARDING ASBESTOS REQUIREMENTS
 CAN BE FOUND ON THEIR WEBSITE:
  
 HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE
 S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION-
 RENOVATION.HTML
  
  
  

Review Stop ENG ENGINEERING CSD
Rev No 3 Status P Date 2021-06-11 Cont ID  
Sent By rrossano Date 2021-06-11 Time   Rev Time 0.00
Received By rrossano Date 2021-06-11 Time   Sent To  
Notes
***NONE***

Review Stop ENG ENGINEERING CSD
Rev No 2 Status F Date 2021-04-05 Cont ID  
Sent By rrossano Date 2021-04-05 Time   Rev Time 0.00
Received By rrossano Date 2021-04-05 Time   Sent To  
Notes
2021-04-05 12:39:06PROVIDE ALL UTILITY SIGN-OFFS AS REQUIRED BY BUILDING
 DIVISION. (WATER/SEWER STILL OUTSTANDING)

Review Stop ENG ENGINEERING CSD
Rev No 1 Status F Date 2020-12-20 Cont ID  
Sent By rrossano Date 2020-12-20 Time   Rev Time  
Received By rrossano Date 2020-12-20 Time   Sent To  
Notes
2020-12-20 08:54:01PROVIDE ALL UTILITY SIGN-OFFS AS REQUIRED BY BUILDING
 DIVISION.

Review Stop HIST HISTORICAL
Rev No 1 Status P Date 2020-12-29 Cont ID  
Sent By fmittner Date 2020-12-29 Time 16:00 Rev Time 0.00
Received By fmittner Date 2020-12-29 Time 16:00 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2021-06-21 Cont ID  
Sent By cthroop Date 2021-06-21 Time 08:53 Rev Time 0.00
Received By cthroop Date 2021-06-03 Time 10:03 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2021-04-09 Cont ID  
Sent By cthroop Date 2021-04-09 Time 16:03 Rev Time 0.00
Received By cthroop Date 2021-04-02 Time 08:22 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2021-01-03 Cont ID  
Sent By cpuell Date 2021-01-03 Time 12:34 Rev Time 0.00
Received By cpuell Date 2020-12-16 Time 17:17 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status P Date 2021-06-21 Cont ID  
Sent By cthroop Date 2021-06-21 Time 08:53 Rev Time 0.00
Received By cthroop Date 2021-06-21 Time 08:39 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status F Date 2021-04-09 Cont ID  
Sent By cthroop Date 2021-04-09 Time 16:01 Rev Time 0.00
Received By cthroop Date 2021-04-09 Time 14:55 Sent To  
Notes
2021-04-09 16:03:07PLAN REVIEW / SIGNATURES
  
 CHRISTOPHER S. THROOP, C.B.O.
 PLANS EXAMINER BUILDING - PX3169
 PLANS EXAMINER 1&2 FAMILY - SFP306
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 CODES IN EFFECT:
 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 NEC2017
 2ND REVIEW
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. DOCUMENTS PREPARED BY AN ARCHITECT OR ENGINEER AND
 SUBMITTED FOR PUBLIC RECORD ARE TO BE SIGNED, SEALED,
 DATED ORIGINALS. A SCAN OF A WET SEAL AND SIGNATURE OR
 DIGITAL SIGNATURE IS NOT CONSIDERED A DIGITAL
 SIGNATURE.
  
 2. EITHER UPLOAD A VALID DIGITALLY SIGNED DOCUMENT OR
 DROP OFF (OR MAIL) ONE PAPER ORIGINAL WITH AN ORIGINAL
 WET SEAL AND SIGNATURE TO:
  
 BUILDING DIVISION, FIRST FLOOR
 CITY OF WEST PALM BEACH
 401 CLEMATIS ST
 WEST PALM BEACH, FL 33401
  
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status N Date 2020-12-23 Cont ID  
Sent By cthroop Date 2020-12-23 Time 13:24 Rev Time 0.00
Received By cthroop Date 2020-12-23 Time 13:16 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2020-12-29 Cont ID  
Sent By fmittner Date 2020-12-29 Time 16:00 Rev Time 0.00
Received By fmittner Date 2020-12-29 Time 16:00 Sent To  
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy