| Plan Review Stops For Permit 20120466 |
| Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
| Rev No |
2 |
Status |
P |
Date |
2021-01-28 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-01-28 |
Time |
14:30 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-01-28 |
Time |
14:30 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
| Rev No |
1 |
Status |
F |
Date |
2020-12-22 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2020-12-22 |
Time |
07:49 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2020-12-22 |
Time |
07:49 |
Sent To |
|
|
| Notes |
| 2020-12-22 07:51:45 | PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE | | | CONTRACTOR, ON LETTERHEAD, STATING THAT THE | | | INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM | | | COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH | | | COUNTY WILL BE FOLLOWED, AND THAT NOTIFICATION WILL BE | | | GIVEN TIMELY. ADDITIONAL INFORMATION REGARDING ASBESTOS | | | REQUIREMENTS CAN BE FOUND ON THEIR WEBSITE: | | | | | | HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE | | | S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION- | | | RENOVATION.HTML | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2021-01-28 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-01-28 |
Time |
14:30 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-01-28 |
Time |
14:30 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2020-12-22 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2020-12-22 |
Time |
07:49 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2020-12-22 |
Time |
07:38 |
Sent To |
|
|
| Notes |
| 2020-12-22 07:49:32 | RESTROOM REMODEL | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected]. | | | CODE USED FOR REVIEW - 2017 FBC WITH WPB CHAPTER 1 | | | AMENDMENTS | | | | | | CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107 | | | 1) DRAWING A0.2 SHOWS SOME REQUIREMENTS INCORRECTLY - | | | MAX. GRAB BAR HEIGHT OF 36" SHOULD BE SHOWN TO THE TOP | | | OF THE GRIPING SURFACE FBC ACC.609.4 - TOILET PAPER | | | DISPENSER LOCATION FROM THE FACE OF THE WATER CLOSET TO | | | THE CENTER OF THE DISPENSER SHOULD BE 7" TO 9" (TO THE | | | CENTER) FBC ACC.604.7 | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2021-01-20 |
|
|
Cont ID |
|
| Sent By |
equinone |
Date |
2021-01-20 |
Time |
15:27 |
Rev Time |
0.00 |
| Received By |
equinone |
Date |
2021-01-20 |
Time |
15:27 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2020-12-21 |
|
|
Cont ID |
|
| Sent By |
equinone |
Date |
2020-12-21 |
Time |
13:14 |
Rev Time |
0.00 |
| Received By |
equinone |
Date |
2020-12-21 |
Time |
10:19 |
Sent To |
|
|
| Notes |
| 2020-12-21 13:14:56 | CODES IN EFFECT | | | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | FAC = FLORIDA ADMINISTRATIVE CODE | | | | | | | | | ELECTRICAL REVIEW STATUS: FAILED, SEE COMMENTS BELOW. | | | | | | 1) PLEASE INDICATE SIZE OF INTEGRATED TRANSFORMER (KVA) | | | BETWEEN PANEL L416A AND P416A | | | 2) ON PANEL SCHEDULE L416A CIRCUIT (1,3,5) INDICATES | | | THE LOAD AS P416 WHICH IS A DIFFERENT VOLTAGE. IT SEEMS | | | FROM THE RISER DIAGRAM THAT THE CIRCUIT GOES TO THE | | | INTEGRATED TRANSFORMER AND THE TO THE PANEL P416. FOR | | | CLARITY PURPOSE PLEASE INDICATE THAT WITH A NOTE OR ON | | | PANEL SCHEDULE. | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | CODES IN EFFECT: | | | | | | IF THE RESUBMITTAL IS NOT PREPARED BY A DESIGN | | | PROFESSIONAL (ARCHITECT OR ENGINEER), AND THE PAGES ARE | | | 11X17 OR SMALLER, YOU MAY RESUBMIT, ALONG WITH A | | | COMPLETED RESUBMITTAL FORM, VIA EMAIL TO | | | [email protected]. THE EMAIL SHOULD INCLUDE THE PERMIT | | | NUMBER AND "RESUBMITTAL" IN THE SUBJECT LINE. THE | | | RESUBMITTAL FORM CAN BE FOUND AT THIS WEBSITE: | | | | | | HTTP://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/B | | | UILDING-PERMIT-FORMS | | | | | | ENRIQUE QUINONEZ | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2021-01-19 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2021-01-19 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2021-01-19 |
Time |
12:09 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2020-12-11 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2020-12-11 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2020-12-11 |
Time |
14:38 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2021-01-28 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-01-28 |
Time |
14:31 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-01-14 |
Time |
08:08 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2020-12-23 |
Time |
|
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2020-12-09 |
Time |
10:35 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2021-01-19 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-01-19 |
Time |
07:22 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-01-19 |
Time |
07:22 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2020-12-17 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2020-12-17 |
Time |
16:23 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2020-12-17 |
Time |
16:09 |
Sent To |
|
|
| Notes |
| 2020-12-17 16:23:26 | 1ST REVIEW FBC-2017 MECHANICAL | | | PERMIT-20120466 | | | | | | CODES IN EFFECT: | | | | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | | 2017 | | | FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017 | | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | | 2017 | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH | | | EDITION 2017 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | | EDITION 2017 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) SHEET M1: THIS PROJECT IS ADDING A WATER CLOSET IN | | | THE LADY?S ROOM AND A URINAL IN THE MEN?S ROOM. PLEASE | | | PROVIDE THE REQUIRED EXHAUST BASED ON THESE ADDITIONS | | | AND PLEASE INCLUDE HOW THE EXHAUST FAN IS CONTROLLED. | | | FBC M TABLE 403.3.1.1 | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE OLD | | | SHEETS FROM THE PLAN SETS, BIND THEM TOGETHER | | | SEPARATELY AND MARK VOID OR OLD ON THEM. PLEASE RETAIN | | | THEM FOR REFERENCE WITH THE NEW SUBMITTED PLANS. THIS | | | PROCESS WILL ALSO APPLY TO ANY DOCUMENTS SUCH AS | | | PRODUCT APPROVALS OR CALCULATIONS BEING REPLACED OR | | | UPDATED. | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2021-01-20 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2021-01-20 |
Time |
18:01 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2021-01-20 |
Time |
17:53 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2020-12-23 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2020-12-23 |
Time |
07:59 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2020-12-22 |
Time |
17:01 |
Sent To |
|
|
| Notes |
| 2020-12-23 07:59:45 | 1ST REVIEW FBC-2017 PLUMBING | | | PERMIT- 20120466 | | | 12/23/2020 | | | | | | CODES IN EFFECT: | | | FBC P- FLORIDA PLUMBING CODE SIXTH EDITION 2017 | | | FBC ACC- FLORIDA ACCESSIBILITY CODE SIXTH ADDITION 2017 | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | | 2017 | | | FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017 | | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | | 2017 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | | EDITION 2017 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) SHEETS P2 & P3: REFER TO SECTION C404.5.1 AND TABLE | | | C404.5.1 FBC EC- MAXIMUM ALLOWABLE PIPE LENGTH METHOD. | | | THE 3/4 IN. HOT WATER PIPE IS EXCEEDING THE MAXIMUM | | | ALLOWABLE PIPE LENGTH FROM THE WATER HEATER TO THE | | | PUBLIC LAVATORIES. IN ACCORDANCE WITH THE TABLE THE | | | MAXIMUM LENGTH IS 0.5 FT. PLEASE ALSO SEE SECTION | | | C404.5.2 FOR ALLOWABLE PIPE VOLUMES AT THE LAVATORIES. | | | | | | 2) SHEET A1.1: PROVIDE THE LENGTH DIMENSION OF THE | | | ACCESSIBLE TOILET ROOMS, AND THE CLEAR FLOOR SPACE | | | DIAGRAMS AND DIMENSIONS FOR THE WATER CLOSETS AND | | | LAVATORIES- SECTIONS 604.3 & 606.2 FBC ACC. | | | | | | 3) A1.1, A3.1: PROVIDE A SECTION CUT OF THE URINAL | | | PARTITIONS- SECTION 405.3.5 FBC P. | | | | | | 4) A3.1: PROVIDE THE SEAT HEIGHTS OF THE WATER CLOSETS | | | MEASURED FROM THE FINISHED FLOORS- SECTION 604.4 FBC | | | ACC. WILL ALL THE WATER CLOSETS BE THE ACCESSIBLE TYPE? | | | | | | 5) A3.1: PROVIDE THE RIM HEIGHTS OF THE URINALS | | | MEASURED FROM THE FINISHED FLOORS- SECTION 605.2 FBC | | | ACC. WILL BOTH URINALS BE ACCESSIBLE? | | | | | | 6) A0.2: REFER TO SECTION 604.7 FBC ACC AND CORRECT THE | | | LOCATION OF THE TOILET PAPER DISPENSER SHOWN IN THE | | | DETAIL TO INDICATE 7-9 INCHES TO THE CENTERLINE OF THE | | | DISPENSER MEASURED FROM THE FRONT OF THE WATER CLOSET. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2021-01-19 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-01-19 |
Time |
07:25 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-01-19 |
Time |
07:25 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2020-12-17 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2020-12-17 |
Time |
16:34 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2020-12-17 |
Time |
16:34 |
Sent To |
|
|
| Notes |
|
|