Plan Review Details - Permit 20120466
Plan Review Stops For Permit 20120466
Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 2 Status P Date 2021-01-28 Cont ID  
Sent By rmcphers Date 2021-01-28 Time 14:30 Rev Time 0.00
Received By rmcphers Date 2021-01-28 Time 14:30 Sent To  
Notes
***NONE***

Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 1 Status F Date 2020-12-22 Cont ID  
Sent By rmcphers Date 2020-12-22 Time 07:49 Rev Time 0.00
Received By rmcphers Date 2020-12-22 Time 07:49 Sent To  
Notes
2020-12-22 07:51:45PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE
 CONTRACTOR, ON LETTERHEAD, STATING THAT THE
 INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM
 COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH
 COUNTY WILL BE FOLLOWED, AND THAT NOTIFICATION WILL BE
 GIVEN TIMELY. ADDITIONAL INFORMATION REGARDING ASBESTOS
 REQUIREMENTS CAN BE FOUND ON THEIR WEBSITE:
  
 HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE
 S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION-
 RENOVATION.HTML
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2021-01-28 Cont ID  
Sent By rmcphers Date 2021-01-28 Time 14:30 Rev Time 0.00
Received By rmcphers Date 2021-01-28 Time 14:30 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2020-12-22 Cont ID  
Sent By rmcphers Date 2020-12-22 Time 07:49 Rev Time 0.00
Received By rmcphers Date 2020-12-22 Time 07:38 Sent To  
Notes
2020-12-22 07:49:32RESTROOM REMODEL
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected].
 CODE USED FOR REVIEW - 2017 FBC WITH WPB CHAPTER 1
 AMENDMENTS
  
 CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107
 1) DRAWING A0.2 SHOWS SOME REQUIREMENTS INCORRECTLY -
 MAX. GRAB BAR HEIGHT OF 36" SHOULD BE SHOWN TO THE TOP
 OF THE GRIPING SURFACE FBC ACC.609.4 - TOILET PAPER
 DISPENSER LOCATION FROM THE FACE OF THE WATER CLOSET TO
 THE CENTER OF THE DISPENSER SHOULD BE 7" TO 9" (TO THE
 CENTER) FBC ACC.604.7
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2021-01-20 Cont ID  
Sent By equinone Date 2021-01-20 Time 15:27 Rev Time 0.00
Received By equinone Date 2021-01-20 Time 15:27 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2020-12-21 Cont ID  
Sent By equinone Date 2020-12-21 Time 13:14 Rev Time 0.00
Received By equinone Date 2020-12-21 Time 10:19 Sent To  
Notes
2020-12-21 13:14:56CODES IN EFFECT
 CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1.
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017
 6TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
 FAC = FLORIDA ADMINISTRATIVE CODE
  
  
 ELECTRICAL REVIEW STATUS: FAILED, SEE COMMENTS BELOW.
  
 1) PLEASE INDICATE SIZE OF INTEGRATED TRANSFORMER (KVA)
 BETWEEN PANEL L416A AND P416A
 2) ON PANEL SCHEDULE L416A CIRCUIT (1,3,5) INDICATES
 THE LOAD AS P416 WHICH IS A DIFFERENT VOLTAGE. IT SEEMS
 FROM THE RISER DIAGRAM THAT THE CIRCUIT GOES TO THE
 INTEGRATED TRANSFORMER AND THE TO THE PANEL P416. FOR
 CLARITY PURPOSE PLEASE INDICATE THAT WITH A NOTE OR ON
 PANEL SCHEDULE.
  
 END OF COMMENTS.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES
 INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE
 PREVIOUSLY REVIEWED SHEETS.
 CODES IN EFFECT:
  
 IF THE RESUBMITTAL IS NOT PREPARED BY A DESIGN
 PROFESSIONAL (ARCHITECT OR ENGINEER), AND THE PAGES ARE
 11X17 OR SMALLER, YOU MAY RESUBMIT, ALONG WITH A
 COMPLETED RESUBMITTAL FORM, VIA EMAIL TO
 [email protected]. THE EMAIL SHOULD INCLUDE THE PERMIT
 NUMBER AND "RESUBMITTAL" IN THE SUBJECT LINE. THE
 RESUBMITTAL FORM CAN BE FOUND AT THIS WEBSITE:
  
 HTTP://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/B
 UILDING-PERMIT-FORMS
  
 ENRIQUE QUINONEZ
 ELECTRICAL PLANS EXAMINER
 561-805-6746
 [email protected]
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2021-01-19 Cont ID  
Sent By pleduc Date 2021-01-19 Time   Rev Time 0.00
Received By pleduc Date 2021-01-19 Time 12:09 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2020-12-11 Cont ID  
Sent By pleduc Date 2020-12-11 Time   Rev Time 0.00
Received By pleduc Date 2020-12-11 Time 14:38 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2021-01-28 Cont ID  
Sent By rmcphers Date 2021-01-28 Time 14:31 Rev Time 0.00
Received By rmcphers Date 2021-01-14 Time 08:08 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date   Cont ID  
Sent By   Date 2020-12-23 Time   Rev Time 0.00
Received By lmarchan Date 2020-12-09 Time 10:35 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2021-01-19 Cont ID  
Sent By medwards Date 2021-01-19 Time 07:22 Rev Time 0.00
Received By medwards Date 2021-01-19 Time 07:22 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2020-12-17 Cont ID  
Sent By medwards Date 2020-12-17 Time 16:23 Rev Time 0.00
Received By medwards Date 2020-12-17 Time 16:09 Sent To  
Notes
2020-12-17 16:23:261ST REVIEW FBC-2017 MECHANICAL
 PERMIT-20120466
  
 CODES IN EFFECT:
  
 FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017
 FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION
 2017
 FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017
 FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION
 2017
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH
 EDITION 2017
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2017
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SHEET M1: THIS PROJECT IS ADDING A WATER CLOSET IN
 THE LADY?S ROOM AND A URINAL IN THE MEN?S ROOM. PLEASE
 PROVIDE THE REQUIRED EXHAUST BASED ON THESE ADDITIONS
 AND PLEASE INCLUDE HOW THE EXHAUST FAN IS CONTROLLED.
 FBC M TABLE 403.3.1.1
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT
 CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE OLD
 SHEETS FROM THE PLAN SETS, BIND THEM TOGETHER
 SEPARATELY AND MARK VOID OR OLD ON THEM. PLEASE RETAIN
 THEM FOR REFERENCE WITH THE NEW SUBMITTED PLANS. THIS
 PROCESS WILL ALSO APPLY TO ANY DOCUMENTS SUCH AS
 PRODUCT APPROVALS OR CALCULATIONS BEING REPLACED OR
 UPDATED.
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop P PLUMBING
Rev No 2 Status P Date 2021-01-20 Cont ID  
Sent By ccole Date 2021-01-20 Time 18:01 Rev Time 0.00
Received By ccole Date 2021-01-20 Time 17:53 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2020-12-23 Cont ID  
Sent By ccole Date 2020-12-23 Time 07:59 Rev Time 0.00
Received By ccole Date 2020-12-22 Time 17:01 Sent To  
Notes
2020-12-23 07:59:451ST REVIEW FBC-2017 PLUMBING
 PERMIT- 20120466
 12/23/2020
  
 CODES IN EFFECT:
 FBC P- FLORIDA PLUMBING CODE SIXTH EDITION 2017
 FBC ACC- FLORIDA ACCESSIBILITY CODE SIXTH ADDITION 2017
 FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017
 FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION
 2017
 FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017
 FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION
 2017
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2017
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SHEETS P2 & P3: REFER TO SECTION C404.5.1 AND TABLE
 C404.5.1 FBC EC- MAXIMUM ALLOWABLE PIPE LENGTH METHOD.
 THE 3/4 IN. HOT WATER PIPE IS EXCEEDING THE MAXIMUM
 ALLOWABLE PIPE LENGTH FROM THE WATER HEATER TO THE
 PUBLIC LAVATORIES. IN ACCORDANCE WITH THE TABLE THE
 MAXIMUM LENGTH IS 0.5 FT. PLEASE ALSO SEE SECTION
 C404.5.2 FOR ALLOWABLE PIPE VOLUMES AT THE LAVATORIES.
  
 2) SHEET A1.1: PROVIDE THE LENGTH DIMENSION OF THE
 ACCESSIBLE TOILET ROOMS, AND THE CLEAR FLOOR SPACE
 DIAGRAMS AND DIMENSIONS FOR THE WATER CLOSETS AND
 LAVATORIES- SECTIONS 604.3 & 606.2 FBC ACC.
  
 3) A1.1, A3.1: PROVIDE A SECTION CUT OF THE URINAL
 PARTITIONS- SECTION 405.3.5 FBC P.
  
 4) A3.1: PROVIDE THE SEAT HEIGHTS OF THE WATER CLOSETS
 MEASURED FROM THE FINISHED FLOORS- SECTION 604.4 FBC
 ACC. WILL ALL THE WATER CLOSETS BE THE ACCESSIBLE TYPE?
  
 5) A3.1: PROVIDE THE RIM HEIGHTS OF THE URINALS
 MEASURED FROM THE FINISHED FLOORS- SECTION 605.2 FBC
 ACC. WILL BOTH URINALS BE ACCESSIBLE?
  
 6) A0.2: REFER TO SECTION 604.7 FBC ACC AND CORRECT THE
 LOCATION OF THE TOILET PAPER DISPENSER SHOWN IN THE
 DETAIL TO INDICATE 7-9 INCHES TO THE CENTERLINE OF THE
 DISPENSER MEASURED FROM THE FRONT OF THE WATER CLOSET.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2021-01-19 Cont ID  
Sent By medwards Date 2021-01-19 Time 07:25 Rev Time 0.00
Received By medwards Date 2021-01-19 Time 07:25 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2020-12-17 Cont ID  
Sent By medwards Date 2020-12-17 Time 16:34 Rev Time 0.00
Received By medwards Date 2020-12-17 Time 16:34 Sent To  
Notes
***NONE***