| Plan Review Stops For Permit 20120427 |
| Review Stop |
AD |
ADDRESSING |
| Rev No |
2 |
Status |
P |
Date |
2021-01-12 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2021-01-12 |
Time |
16:34 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2021-01-12 |
Time |
16:34 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
AD |
ADDRESSING |
| Rev No |
1 |
Status |
F |
Date |
2020-12-15 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2020-12-15 |
Time |
09:35 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2020-12-15 |
Time |
09:35 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
| Rev No |
1 |
Status |
N |
Date |
2020-12-11 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2020-12-11 |
Time |
14:43 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2020-12-11 |
Time |
14:43 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2021-02-23 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2021-02-23 |
Time |
13:33 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2021-02-23 |
Time |
13:26 |
Sent To |
|
|
| Notes |
| 2021-02-23 13:34:19 | BUILDING REVIEW APPROVED WITH PROVISO: | | | A)SOLAR SHADES TO COMPLY WITH THE TESTS REQUIRED BY | | | SECTION 806.4 FBC-BUILDING FOR COMBUSTIBLE DECORATIVE | | | MATERIALS EXCEPTION #3 OF SECTION 806.3 FBC-BUILDING | | | B)INTERIOR FLOOR-WALL RUBBER BASE BASE TO COMPLY WITH | | | TEST REQUIRED BY SECTION 806.8 FBC-BUILDING. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2021-02-19 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2021-02-19 |
Time |
18:07 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2021-02-19 |
Time |
18:05 |
Sent To |
|
|
| Notes |
| 2021-02-19 18:07:50 | | | | THIRD BUILDING REVIEW COMMENTS | | | CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS. | | | PERMIT #20120427 | | | | | | 1- SHEET ALS1.1: | | | | | | ORIGINAL COMMENT: | | | A)THE TERRACE SHOWN ON THE LEFT HAND SIDE IS PART OF | | | THE SUITE 1030. OCCUPANT LOAD CALCULATIONS NEED TO BE | | | REVISED. NEED TO ADD THE OCCUPANT LOAD OF THE TERRACE. | | | NOTE: TERRACE OCCUPANT LOAD IS BASED ON ASSEMBLY USE | | | NOT BUSINESS. SEE TABLE 1004.1.2 FBC-BUILDING. | | | | | | RESPONSE: | | | ACCORDING TO SHEET LS1.09 OF SHELL PERMIT #18090469 THE | | | SOUTH TERRACE OCCUPANT LOAD IS 33 OCCUPANTS NOT 31 | | | OCCUPANTS. REVISE AS REQUIRED. | | | SEC. 107.2.1 CITY AMENDMENTS. | | | | | | NOTE: THE 33 OCCUPANTS WAS MENTIONED ON MY SECOND | | | REVIEW COMMENTS. SEE BELOW RESPONSE ON MY SECOND | | | REVIEW: | | | | | | RESPONSE: | | | ARCHITECT'S RESPONSE LETTER REFERENCED SHEET LS1.09 OF | | | SHELL PERMIT #18090469 FOR TERRACE OCCUPANT LOAD. SHEET | | | LS1.09 SUBMITTED FOR REFERENCE IS NOT THE OFFICIAL | | | APPROVED DRAWING. THIS SHEET SHOWS TERRACE OCCUPANCY | | | LIMITED TO 17 OCCUPANTS. SINCE, THIS IS NOT THE | | | OFFICIAL APPROVED DRAWING, I RESEARCHED THE CITY | | | APPROVED SET OF DOCUMENTS AND FOUND THAT SHEET LS1.09 | | | SHOWS THE TERRACE OCCUPANCY IS LIMITED TO 33 OCCUPANTS | | | NOT 17 OCCUPANTS. PLEASE, REVISE AS REQUIRED, INCLUDING | | | THE OCCUPANT LOAD CALCULATIONS OR LET ME KNOW IF THERE | | | IS ANY OTHER APPROVED REVISED PLAN THAT I AM MISSING. | | | (THIS WAS DISCUSSED WITH ROBERT BROWN). | | | SEC. 107.2.1 CITY AMENDMENTS. | | | | | | | | | 3- OK | | | | | | 4- PROVISO: | | | A)SOLAR SHADES TO COMPLY WITH THE TESTS REQUIRED BY | | | SECTION 806.4 FBC-BUILDING FOR COMBUSTIBLE DECORATIVE | | | MATERIALS EXCEPTION #3 OF SECTION 806.3 FBC-BUILDING | | | B)INTERIOR FLOOR-WALL RUBBER BASE BASE TO COMPLY WITH | | | TEST REQUIRED BY SECTION 806.8 FBC-BUILDING. | | | | | | WHEN RESUBMITTING, A TRANSMITTAL LETTER LISTING THE | | | ORIGINAL REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF | | | THE REVISION MADE, IDENTIFYING THE SHEET OR | | | SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND WILL | | | HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR | | | ANTICIPATED COOPERATION. | | | | | | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY | | | QUESTIONS REGARDING THESE COMMENTS, | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2021-02-12 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2021-02-12 |
Time |
18:56 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2021-02-12 |
Time |
16:57 |
Sent To |
|
|
| Notes |
| 2021-02-12 18:57:11 | | | | SECOND BUILDING REVIEW COMMENTS | | | CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS. | | | PERMIT #20120427 | | | | | | 1- SHEET ALS1.1: | | | | | | ORIGINAL COMMENT: | | | A)THE TERRACE SHOWN ON THE LEFT HAND SIDE IS PART OF | | | THE SUITE 1030. OCCUPANT LOAD CALCULATIONS NEED TO BE | | | REVISED. NEED TO ADD THE OCCUPANT LOAD OF THE TERRACE. | | | NOTE: TERRACE OCCUPANT LOAD IS BASED ON ASSEMBLY USE | | | NOT BUSINESS. SEE TABLE 1004.1.2 FBC-BUILDING. | | | | | | RESPONSE: | | | ARCHITECT'S RESPONSE LETTER REFERENCED SHEET LS1.09 OF | | | SHELL PERMIT #18090469 FOR TERRACE OCCUPANT LOAD. SHEET | | | LS1.09 SUBMITTED FOR REFERENCE IS NOT THE OFFICIAL | | | APPROVED DRAWING. THIS SHEET SHOWS TERRACE OCCUPANCY | | | LIMITED TO 17 OCCUPANTS. SINCE, THIS IS NOT THE | | | OFFICIAL APPROVED DRAWING, I RESEARCHED THE CITY | | | APPROVED SET OF DOCUMENTS AND FOUND THAT SHEET LS1.09 | | | SHOWS THE TERRACE OCCUPANCY IS LIMITED TO 33 OCCUPANTS | | | NOT 17 OCCUPANTS. PLEASE, REVISE AS REQUIRED, INCLUDING | | | THE OCCUPANT LOAD CALCULATIONS OR LET ME KNOW IF THERE | | | IS ANY OTHER APPROVED REVISED PLAN THAT I AM MISSING. | | | (THIS WAS DISCUSSED WITH ROBERT BROWN). | | | SEC. 107.2.1 CITY AMENDMENTS. | | | | | | 3- OK | | | | | | 4- PROVISO: | | | A)SOLAR SHADES TO COMPLY WITH THE TESTS REQUIRED BY | | | SECTION 806.4 FBC-BUILDING FOR COMBUSTIBLE DECORATIVE | | | MATERIALS EXCEPTION #3 OF SECTION 806.3 FBC-BUILDING | | | B)INTERIOR FLOOR-WALL RUBBER BASE BASE TO COMPLY WITH | | | TEST REQUIRED BY SECTION 806.8 FBC-BUILDING. | | | | | | WHEN RESUBMITTING, A TRANSMITTAL LETTER LISTING THE | | | ORIGINAL REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF | | | THE REVISION MADE, IDENTIFYING THE SHEET OR | | | SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND WILL | | | HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR | | | ANTICIPATED COOPERATION. | | | | | | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY | | | QUESTIONS REGARDING THESE COMMENTS, | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2021-01-29 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2021-01-29 |
Time |
16:50 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2021-01-28 |
Time |
14:27 |
Sent To |
|
|
| Notes |
| 2021-01-29 16:59:36 | BUILDING REVIEW COMMENTS | | | CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS. | | | PERMIT #20120427 | | | | | | 1- SHEET ALS1.1: | | | A)THE TERRACE SHOWN ON THE LEFT HAND SIDE IS PART OF | | | THE SUITE 1030. OCCUPANT LOAD CALCULATIONS NEED TO BE | | | REVISED. NEED TO ADD THE OCCUPANT LOAD OF THE TERRACE. | | | NOTE: TERRACE OCCUPANT LOAD IS BASED ON ASSEMBLY USE | | | NOT BUSINESS. SEE TABLE 1004.1.2 FBC-BUILDING. | | | | | | B)BASED ON THE ADDITIONAL OCCUPANT LOAD OF THE TERRACE, | | | IT LOOKS LIKE THE ROOM IDENTIFIED AS "POINT 72/SUITE | | | 1030 AT THE BOTTOM OF THE FLOOR PLAN NEEDS TO HAVE TWO | | | "EXIT ACCESS DOORWAYS". ONLY ONE WAS PROVIDED. REVISE | | | AS REQUIRED. SEC. 1006.2.1 FBC-BUILDING. | | | | | | C)THE EGRESS TRAVEL DISTANCE FROM THE TERRACE AREA TO | | | THE EXIT NEEDS TO BE SHOWN ON THE FLOOR PLAN AND REVISE | | | THE TRAVEL DISTANCE UNDER CODE DATA. SEC. 1017.3 | | | FBC-BUILDING. | | | | | | D)CLARIFY OCCUPANT CALCULATIONS. WHY THE MULTI-TENANT | | | CORRIDOR HAS AN OCCUPANT LOAD OF 21 OCCUPANTS?. ISN'T | | | THIS CORRIDOR TO BE USED FOR ALL TENANTS IN THIS | | | FLOOR?. WHY USING 100 S.F. PER OCCUPANT?. THERE ARE | | | OTHER OCCUPANCIES IN THIS FLOOR BESIDES BUSINESS. FOR | | | EXAMPLE FLOOR PLAN SHOWS A FITNESS AREA AND CONFERENCE | | | AREA. | | | PROVIDE CALCULATIONS FOR SIZING THE CORRIDOR WIDTH AND | | | CAPACITY BASED ON THE OVERALL OCCUPANCY OF ENTIRE FLOOR | | | AS REQUIRED BY SEC. 1020.2 FBC-BUILDING. | | | NOTE: COORDINATE WITH ITEM #3(B) BELOW. | | | | | | E)MISSING EXIT SIGN ON BOTH SIDES OF WALL DIVIDING THE | | | SUITE 1030 AND THE "EXPANSION". (THIS SIGN ALLOWS | | | OCCUPANTS TO KNOW THAT THERE IS ANOTHER EXIT ACCESS | | | DOOR ON THAT DIRECTION). SEE CLOUDED AREA WITH DELTA | | | #2. SEC. 1013.1 FBC-BUILDING. | | | | | | F)REQUIRED NUMBER OF EXITS SHOWN UNDER CODE DATA IS | | | INCORRECT. TWO TWO EXIT ACCESS DOORWAYS ARE REQUIRED | | | FROM SUITE 1030. SEC. 1006.2.1 FBC-BUILDING. | | | | | | 2- THIS PERMIT APPLICATION IS FOR THE MULTI-TENANT | | | CORRIDOR ALSO. THERE SOME DOORS THAT SWING OUT INTO THE | | | CORRIDOR. IT LOOKS LIKE THIS DOORS WILL BLOCK THE | | | CORRIDOR MEANS OF EGRESS. NOTE: THIS COMMENT APPLIES TO | | | THE MECHANICAL ROOM, CONFERENCE AREA AND STORAGE ROOM. | | | REVISE AS REQUIRED ALL PLANS SHOWING THESE DOORS. SEC. | | | 1005.7.1 FBC-BUILDING. | | | | | | 3- SHEET A1.1.5: | | | A)THERE IS A 4'-10" DIMENSION FOR RECESSED DOOR #900E | | | AT THE BOTTOM RIGHT OF PLAN. SHOW HOW COMPLYING WITH | | | THE 18 INCHES MANEUVERING CLEARANCE REQUIRED BY SEC. | | | 404.2.4 FBC-ACCESSIBILITY. | | | | | | B)PROVIDE CALCULATIONS FOR SIZING THE CORRIDOR WIDTH | | | AND CAPACITY BASED ON THE OVERALL OCCUPANCY OF ENTIRE | | | FLOOR AS REQUIRED BY SEC. 1020.2 FBC-BUILDING. | | | NOTE: COORDINATE WITH ITEM #1(D) ABOVE. | | | | | | 4- PROVISO: | | | A)SOLAR SHADES TO COMPLY WITH THE TESTS REQUIRED BY | | | SECTION 806.4 FBC-BUILDING FOR COMBUSTIBLE DECORATIVE | | | MATERIALS EXCEPTION #3 OF SECTION 806.3 FBC-BUILDING | | | B)INTERIOR FLOOR-WALL RUBBER BASE BASE TO COMPLY WITH | | | TEST REQUIRED BY SECTION 806.8 FBC-BUILDING. | | | | | | WHEN RESUBMITTING, A TRANSMITTAL LETTER LISTING THE | | | ORIGINAL REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF | | | THE REVISION MADE, IDENTIFYING THE SHEET OR | | | SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND WILL | | | HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR | | | ANTICIPATED COOPERATION. | | | | | | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY | | | QUESTIONS REGARDING THESE COMMENTS, | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2021-02-22 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2021-02-22 |
Time |
08:15 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2021-02-19 |
Time |
16:56 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2021-02-11 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2021-02-11 |
Time |
13:30 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2021-02-11 |
Time |
07:40 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2021-01-26 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2021-01-26 |
Time |
12:45 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2021-01-26 |
Time |
10:27 |
Sent To |
|
|
| Notes |
| 2021-01-26 12:49:20 | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | FLORIDA BUILDING CODE 2017 6TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 6TH ED | | | NFPA 70 2014 EDITION | | | | | | JAKE LEAHY BN, BU, PX | | | ELECTRICAL PLANS EXAMINER II | | | 561-805-6713 | | | [email protected] | | | | | | BRANCH CIRCUITS FOR THIS SPACE ARE USING THE SAME | | | CIRCUIT FOR ANOTHER SPACE 1010 SEE PANEL SCHEDULE TO | | | 20120426 BOTH ARE FED FROM LA9. | | | | | | | | | |
|
|
| Review Stop |
E-LOWVOLT |
ELECTRICAL LOW VOLTAGE |
| Rev No |
1 |
Status |
P |
Date |
2021-02-11 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2021-02-11 |
Time |
13:29 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2021-02-11 |
Time |
13:13 |
Sent To |
|
|
| Notes |
| 2021-02-11 13:29:50 | VOICE AND DATA ONLY JLEAHY |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2021-02-23 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2021-02-23 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2021-02-23 |
Time |
11:55 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2021-02-10 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2021-02-10 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2021-02-10 |
Time |
09:26 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2021-01-08 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2021-01-08 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2021-01-06 |
Time |
16:09 |
Sent To |
|
|
| Notes |
| 2021-01-08 12:37:04 | FIRE PROVISO: | | | | | | THERE IS A DOOR INDICATED FROM THE FUTURE CONFERENCE | | | ROOM THAT OPENS OUT INOT THE CORRIDOR POSSIBLE | | | OBSTRUCTING EGRESS. | | | | | | THIS DOOR APPEARS TO OPEN INTO THE PATH OF EGRESS. | | | PLEASE REVIEW AND CORRECT IF IN SCOPE OF THIS WORK. | | | NFPA 101, CH 7, 7.2.14.3.1 AND PROVIDE AN APPLICABLE | | | REVISION. | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2021-03-02 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2021-03-02 |
Time |
16:34 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2021-03-02 |
Time |
15:52 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2021-02-23 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2021-02-23 |
Time |
13:45 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2021-02-18 |
Time |
12:29 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2021-02-17 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2021-02-17 |
Time |
10:05 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2021-02-10 |
Time |
17:39 |
Sent To |
|
|
| Notes |
| 2021-02-10 17:43:33 | TO BLDG AUDIT ROUND 2 | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2021-02-10 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2021-02-10 |
Time |
17:39 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2021-02-09 |
Time |
12:15 |
Sent To |
|
|
| Notes |
| 2021-02-10 17:43:20 | TO FIRE REVIEW | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2021-01-29 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2021-01-29 |
Time |
16:50 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2021-01-08 |
Time |
16:32 |
Sent To |
I |
|
| Notes |
| 2021-02-10 17:43:09 | BLDG AUDIT |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2021-01-11 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2021-01-11 |
Time |
13:39 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2020-12-30 |
Time |
11:29 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
N |
Date |
2020-12-31 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2020-12-31 |
Time |
13:48 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2020-12-31 |
Time |
13:48 |
Sent To |
|
|
| Notes |
| 2020-12-31 13:48:40 | IMPACT REVIEW DONE UNDER 18090469 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2021-02-22 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-02-22 |
Time |
06:38 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-02-22 |
Time |
06:38 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2021-02-11 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-02-11 |
Time |
09:13 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-02-11 |
Time |
09:13 |
Sent To |
|
|
| Notes |
| 2021-02-11 09:17:07 | THE RESPONSE LETTER INDICATES THE CORRECTIONS WERE MADE | | | ON REVISED SHEET M6.01. REVISED SHEET M6.01 IS NOT IN | | | THIS REVISION UPLOAD. PLEASE UPLOAD THE REVISED SHEET | | | FOR REVIEW. | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2021-01-21 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-01-21 |
Time |
11:33 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-01-21 |
Time |
10:14 |
Sent To |
|
|
| Notes |
| 2021-01-21 11:33:24 | 1ST REVIEW FBC-2020 MECHANICAL | | | PERMIT-20120427 | | | | | | CODES IN EFFECT: | | | | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2020 | | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2020 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | | 2020 | | | FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2020 | | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | | 2020 | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH | | | EDITION 2020 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | | EDITION 2020 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) SHEET M6.01- INDICATES A IAQ- VENTILATION DESIGN | | | CRITERIA. IF IAQ IS TO BE USED TO REDUCE THE OUTDOOR | | | AIR REQUIRED FOR THIS SPACE PLEASE INCLUDE THE IAQ | | | CALCULATIONS. FBC M 403.2 (EXCEPTION) | | | | | | 2) SHEET M601- PLEASE PROVIDE OUTDOOR CALCULATIONS | | | BASED ON TABLE 403.3.1.1 NOT BASED ON NUMBER OF PEOPLE | | | IN ROOM. FBC M 403.3.1.1 | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE OLD | | | SHEETS FROM THE PLAN SETS, BIND THEM TOGETHER | | | SEPARATELY AND MARK VOID OR OLD ON THEM. PLEASE RETAIN | | | THEM FOR REFERENCE WITH THE NEW SUBMITTED PLANS. THIS | | | PROCESS WILL ALSO APPLY TO ANY DOCUMENTS SUCH AS | | | PRODUCT APPROVALS OR CALCULATIONS BEING REPLACED OR | | | UPDATED. | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2021-02-17 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2021-02-17 |
Time |
10:04 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2021-02-17 |
Time |
09:52 |
Sent To |
|
|
| Notes |
| 2021-02-17 10:05:34 | 02/17/21 REVIEWED FOR CODE COMPLIANCE (PLUMBING) | | | | | | BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE | | | COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN | | | PROFESSIONAL, CONTRACTORS, OR THEIR REPRESENTATIVES | | | FROM THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL, | | | STATE, AND NATIONAL CODES AND STANDARDS IN EFFECT AT | | | THE TIME OF PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK | | | OF EVERY ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM | | | REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES | | | / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO | | | AVOID VOIDING OF THE PERMIT. | | | | | | LUIS A. CRESPO | | | PLUMBING PLAN EXAMINER / INSPECTOR | | | EMAIL: [email protected] OFFICE: 561 805-6720 | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2021-01-28 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2021-01-28 |
Time |
15:18 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2021-01-28 |
Time |
15:18 |
Sent To |
|
|
| Notes |
| 2021-01-28 15:19:03 | 1ST REVIEW FBC-2017 PLUMBING | | | PERMIT- 20120427 | | | 1/28/2021 | | | | | | CODES IN EFFECT: | | | FBC P- FLORIDA PLUMBING CODE SIXTH EDITION 2017 | | | FBC ACC- FLORIDA ACCESSIBILITY CODE SIXTH ADDITION 2017 | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | | 2017 | | | FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017 | | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | | 2017 | | | FS- F | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | | EDITION 2017 | | | | | | PLAN REVIEW RESULTS: DENIED: | | | | | | 1) SHEETS A1.1.1 & A.3.01: PLEASE SHOW THE CLEAR FLOOR | | | SPACE PARALLEL APPROACH DIAGRAM AND DIMENSIONS FOR THE | | | NEW LOUNGE SINK, DISHWASHER AND ICE MACHINE- SECTIONS | | | 305.1 & 804.6, & 804.6.3 FBC ACC. DETAIL 2/3.02: SINK | | | HEIGHT NOT SHOWN- SECTION 606.3. | | | | | | 2) SHEETS P1.02 & P2.00: PLANS SHOW CONDENSATION FROM | | | THE ICE MAKER DRAINING INTO THE SANITARY SYSTEM WHICH | | | IS PROHIBITED- SEC. 90-126 WPB CODE OF ORDINANCES. THE | | | DRAINAGE SHALL BE DISCHARGED TO AN APPROVED PLACE OF | | | DISPOSAL SUCH AS THE STORM DRAINAGE SYSTEM. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
PRIVATEPRV |
PRIVATE PROVIDER DOCUMENTS |
| Rev No |
4 |
Status |
P |
Date |
2021-03-02 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2021-03-02 |
Time |
14:00 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2021-03-02 |
Time |
14:00 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
PRIVATEPRV |
PRIVATE PROVIDER DOCUMENTS |
| Rev No |
3 |
Status |
F |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2021-02-22 |
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
2021-02-22 |
Time |
|
Sent To |
|
|
| Notes |
| 2021-02-22 10:45:40 | FS553, AFFIDAVITS FOR REVISED PAGES WERE NOT SUBMITTED; | | | PLEASE UPLOAD | | | | | | | | | |
|
|
| Review Stop |
PRIVATEPRV |
PRIVATE PROVIDER DOCUMENTS |
| Rev No |
2 |
Status |
F |
Date |
2021-02-16 |
|
|
Cont ID |
|
| Sent By |
rgathrig |
Date |
2021-02-16 |
Time |
17:40 |
Rev Time |
0.00 |
| Received By |
rgathrig |
Date |
2021-02-16 |
Time |
17:40 |
Sent To |
|
|
| Notes |
| 2021-02-16 17:39:55 | PRIVATE PROVIDER REVIEW NOT APPROVED | | | | | | THIS REVIEW WAS FOR THE NOTICE TO BUILDING OFFICIAL AND | | | INSPECTOR ONLY. AFIDAVITS FOR PLAN REVIEW COMPLIANCE | | | WERE NOT REVIEWED BECAUSE BUILDING AND MECHANICAL TRADE | | | FAILED THE 2ND REVIEW AND PLUMBING STILL NEEDS TO BE | | | DONE | | | | | | RICHARD GATHRIGHT | | | ABO | | | 561 805 6679 |
|
|
| Review Stop |
PRIVATEPRV |
PRIVATE PROVIDER DOCUMENTS |
| Rev No |
1 |
Status |
F |
Date |
2021-01-14 |
|
|
Cont ID |
|
| Sent By |
rgathrig |
Date |
2021-01-14 |
Time |
15:52 |
Rev Time |
0.00 |
| Received By |
rgathrig |
Date |
2021-01-14 |
Time |
15:52 |
Sent To |
|
|
| Notes |
| 2021-01-14 15:53:07 | PRIVATE PROVIDER REVIEW APPROVED WITH PROVISO | | | THIS REVIEW IS FOR THE NOTICE TO BUILDING OFFICIAL, | | | INSURANCE LIMITS, PLAN REVIEWERS, AND INSPECTORS ONLY. | | | AFFIDAVITS WERE NOT REVIEWED FOR COMPLIANCE WITH THE | | | PROJECT PAGES. HOWEVER, IT IS NOTED THAT THE PRIVATE | | | PROVIDER WILL NEED TO CORRECT THE FORMAT OF THE | | | AFFIDAVITS SUBMITTED TO HAVE HIS SIGNATURE AND | | | ATTESTATION FOR ALL THE PAGES IN THE DESIGN DOCUMENTS | | | REVIEWED FOR FLORIDA BUILDING CODE COMPLIANCE. | | | PLAN REVIEW AFFIDAVITS WILL NEED TO BE REVIEWED AFTER | | | THE PLAN REVIEW AUDITS ARE COMPLETE. THIS SUBMITTAL CAN | | | MOVE ON TO THE FLORIDA BUILDING CODE REVIEW | | | | | | RICHARD GATHRIGHT | | | ASSISTANT BUILDING OFFICIAL | | | 5618056679 | | | | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
P |
Date |
2021-02-22 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-02-22 |
Time |
06:40 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-02-22 |
Time |
06:40 |
Sent To |
|
|
| Notes |
| 2021-02-19 18:12:41 | DIGITAL SIGNATURE ON ARCHITECTURAL DWGS IS OK. JG. |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2021-02-13 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2021-02-13 |
Time |
06:27 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2021-02-13 |
Time |
06:27 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2021-01-29 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2021-01-29 |
Time |
16:50 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2021-01-29 |
Time |
16:50 |
Sent To |
|
|
| Notes |
|
|