Plan Review Details - Permit 20120427
Plan Review Stops For Permit 20120427
Review Stop AD ADDRESSING
Rev No 2 Status P Date 2021-01-12 Cont ID  
Sent By cpuell Date 2021-01-12 Time 16:34 Rev Time 0.00
Received By cpuell Date 2021-01-12 Time 16:34 Sent To  
Notes
***NONE***

Review Stop AD ADDRESSING
Rev No 1 Status F Date 2020-12-15 Cont ID  
Sent By cpuell Date 2020-12-15 Time 09:35 Rev Time 0.00
Received By cpuell Date 2020-12-15 Time 09:35 Sent To  
Notes
2020-12-15 09:35:43PLEASE REACH OUT TO [email protected] TO ESTABLISH SUITE
 NUMBER

Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 1 Status N Date 2020-12-11 Cont ID  
Sent By shill Date 2020-12-11 Time 14:43 Rev Time 0.00
Received By shill Date 2020-12-11 Time 14:43 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2021-02-23 Cont ID  
Sent By jgomez Date 2021-02-23 Time 13:33 Rev Time 0.00
Received By jgomez Date 2021-02-23 Time 13:26 Sent To  
Notes
2021-02-23 13:34:19BUILDING REVIEW APPROVED WITH PROVISO:
 A)SOLAR SHADES TO COMPLY WITH THE TESTS REQUIRED BY
 SECTION 806.4 FBC-BUILDING FOR COMBUSTIBLE DECORATIVE
 MATERIALS EXCEPTION #3 OF SECTION 806.3 FBC-BUILDING
 B)INTERIOR FLOOR-WALL RUBBER BASE BASE TO COMPLY WITH
 TEST REQUIRED BY SECTION 806.8 FBC-BUILDING.

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2021-02-19 Cont ID  
Sent By jgomez Date 2021-02-19 Time 18:07 Rev Time 0.00
Received By jgomez Date 2021-02-19 Time 18:05 Sent To  
Notes
2021-02-19 18:07:50 
 THIRD BUILDING REVIEW COMMENTS
 CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS.
 PERMIT #20120427
  
 1- SHEET ALS1.1:
  
 ORIGINAL COMMENT:
 A)THE TERRACE SHOWN ON THE LEFT HAND SIDE IS PART OF
 THE SUITE 1030. OCCUPANT LOAD CALCULATIONS NEED TO BE
 REVISED. NEED TO ADD THE OCCUPANT LOAD OF THE TERRACE.
 NOTE: TERRACE OCCUPANT LOAD IS BASED ON ASSEMBLY USE
 NOT BUSINESS. SEE TABLE 1004.1.2 FBC-BUILDING.
  
 RESPONSE:
 ACCORDING TO SHEET LS1.09 OF SHELL PERMIT #18090469 THE
 SOUTH TERRACE OCCUPANT LOAD IS 33 OCCUPANTS NOT 31
 OCCUPANTS. REVISE AS REQUIRED.
 SEC. 107.2.1 CITY AMENDMENTS.
  
 NOTE: THE 33 OCCUPANTS WAS MENTIONED ON MY SECOND
 REVIEW COMMENTS. SEE BELOW RESPONSE ON MY SECOND
 REVIEW:
  
 RESPONSE:
 ARCHITECT'S RESPONSE LETTER REFERENCED SHEET LS1.09 OF
 SHELL PERMIT #18090469 FOR TERRACE OCCUPANT LOAD. SHEET
 LS1.09 SUBMITTED FOR REFERENCE IS NOT THE OFFICIAL
 APPROVED DRAWING. THIS SHEET SHOWS TERRACE OCCUPANCY
 LIMITED TO 17 OCCUPANTS. SINCE, THIS IS NOT THE
 OFFICIAL APPROVED DRAWING, I RESEARCHED THE CITY
 APPROVED SET OF DOCUMENTS AND FOUND THAT SHEET LS1.09
 SHOWS THE TERRACE OCCUPANCY IS LIMITED TO 33 OCCUPANTS
 NOT 17 OCCUPANTS. PLEASE, REVISE AS REQUIRED, INCLUDING
 THE OCCUPANT LOAD CALCULATIONS OR LET ME KNOW IF THERE
 IS ANY OTHER APPROVED REVISED PLAN THAT I AM MISSING.
 (THIS WAS DISCUSSED WITH ROBERT BROWN).
 SEC. 107.2.1 CITY AMENDMENTS.
  
  
 3- OK
  
 4- PROVISO:
 A)SOLAR SHADES TO COMPLY WITH THE TESTS REQUIRED BY
 SECTION 806.4 FBC-BUILDING FOR COMBUSTIBLE DECORATIVE
 MATERIALS EXCEPTION #3 OF SECTION 806.3 FBC-BUILDING
 B)INTERIOR FLOOR-WALL RUBBER BASE BASE TO COMPLY WITH
 TEST REQUIRED BY SECTION 806.8 FBC-BUILDING.
  
 WHEN RESUBMITTING, A TRANSMITTAL LETTER LISTING THE
 ORIGINAL REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF
 THE REVISION MADE, IDENTIFYING THE SHEET OR
 SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND WILL
 HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR
 ANTICIPATED COOPERATION.
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2021-02-12 Cont ID  
Sent By jgomez Date 2021-02-12 Time 18:56 Rev Time 0.00
Received By jgomez Date 2021-02-12 Time 16:57 Sent To  
Notes
2021-02-12 18:57:11 
 SECOND BUILDING REVIEW COMMENTS
 CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS.
 PERMIT #20120427
  
 1- SHEET ALS1.1:
  
 ORIGINAL COMMENT:
 A)THE TERRACE SHOWN ON THE LEFT HAND SIDE IS PART OF
 THE SUITE 1030. OCCUPANT LOAD CALCULATIONS NEED TO BE
 REVISED. NEED TO ADD THE OCCUPANT LOAD OF THE TERRACE.
 NOTE: TERRACE OCCUPANT LOAD IS BASED ON ASSEMBLY USE
 NOT BUSINESS. SEE TABLE 1004.1.2 FBC-BUILDING.
  
 RESPONSE:
 ARCHITECT'S RESPONSE LETTER REFERENCED SHEET LS1.09 OF
 SHELL PERMIT #18090469 FOR TERRACE OCCUPANT LOAD. SHEET
 LS1.09 SUBMITTED FOR REFERENCE IS NOT THE OFFICIAL
 APPROVED DRAWING. THIS SHEET SHOWS TERRACE OCCUPANCY
 LIMITED TO 17 OCCUPANTS. SINCE, THIS IS NOT THE
 OFFICIAL APPROVED DRAWING, I RESEARCHED THE CITY
 APPROVED SET OF DOCUMENTS AND FOUND THAT SHEET LS1.09
 SHOWS THE TERRACE OCCUPANCY IS LIMITED TO 33 OCCUPANTS
 NOT 17 OCCUPANTS. PLEASE, REVISE AS REQUIRED, INCLUDING
 THE OCCUPANT LOAD CALCULATIONS OR LET ME KNOW IF THERE
 IS ANY OTHER APPROVED REVISED PLAN THAT I AM MISSING.
 (THIS WAS DISCUSSED WITH ROBERT BROWN).
 SEC. 107.2.1 CITY AMENDMENTS.
  
 3- OK
  
 4- PROVISO:
 A)SOLAR SHADES TO COMPLY WITH THE TESTS REQUIRED BY
 SECTION 806.4 FBC-BUILDING FOR COMBUSTIBLE DECORATIVE
 MATERIALS EXCEPTION #3 OF SECTION 806.3 FBC-BUILDING
 B)INTERIOR FLOOR-WALL RUBBER BASE BASE TO COMPLY WITH
 TEST REQUIRED BY SECTION 806.8 FBC-BUILDING.
  
 WHEN RESUBMITTING, A TRANSMITTAL LETTER LISTING THE
 ORIGINAL REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF
 THE REVISION MADE, IDENTIFYING THE SHEET OR
 SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND WILL
 HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR
 ANTICIPATED COOPERATION.
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2021-01-29 Cont ID  
Sent By jgomez Date 2021-01-29 Time 16:50 Rev Time 0.00
Received By jgomez Date 2021-01-28 Time 14:27 Sent To  
Notes
2021-01-29 16:59:36BUILDING REVIEW COMMENTS
 CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS.
 PERMIT #20120427
  
 1- SHEET ALS1.1:
 A)THE TERRACE SHOWN ON THE LEFT HAND SIDE IS PART OF
 THE SUITE 1030. OCCUPANT LOAD CALCULATIONS NEED TO BE
 REVISED. NEED TO ADD THE OCCUPANT LOAD OF THE TERRACE.
 NOTE: TERRACE OCCUPANT LOAD IS BASED ON ASSEMBLY USE
 NOT BUSINESS. SEE TABLE 1004.1.2 FBC-BUILDING.
  
 B)BASED ON THE ADDITIONAL OCCUPANT LOAD OF THE TERRACE,
 IT LOOKS LIKE THE ROOM IDENTIFIED AS "POINT 72/SUITE
 1030 AT THE BOTTOM OF THE FLOOR PLAN NEEDS TO HAVE TWO
 "EXIT ACCESS DOORWAYS". ONLY ONE WAS PROVIDED. REVISE
 AS REQUIRED. SEC. 1006.2.1 FBC-BUILDING.
  
 C)THE EGRESS TRAVEL DISTANCE FROM THE TERRACE AREA TO
 THE EXIT NEEDS TO BE SHOWN ON THE FLOOR PLAN AND REVISE
 THE TRAVEL DISTANCE UNDER CODE DATA. SEC. 1017.3
 FBC-BUILDING.
  
 D)CLARIFY OCCUPANT CALCULATIONS. WHY THE MULTI-TENANT
 CORRIDOR HAS AN OCCUPANT LOAD OF 21 OCCUPANTS?. ISN'T
 THIS CORRIDOR TO BE USED FOR ALL TENANTS IN THIS
 FLOOR?. WHY USING 100 S.F. PER OCCUPANT?. THERE ARE
 OTHER OCCUPANCIES IN THIS FLOOR BESIDES BUSINESS. FOR
 EXAMPLE FLOOR PLAN SHOWS A FITNESS AREA AND CONFERENCE
 AREA.
 PROVIDE CALCULATIONS FOR SIZING THE CORRIDOR WIDTH AND
 CAPACITY BASED ON THE OVERALL OCCUPANCY OF ENTIRE FLOOR
 AS REQUIRED BY SEC. 1020.2 FBC-BUILDING.
 NOTE: COORDINATE WITH ITEM #3(B) BELOW.
  
 E)MISSING EXIT SIGN ON BOTH SIDES OF WALL DIVIDING THE
 SUITE 1030 AND THE "EXPANSION". (THIS SIGN ALLOWS
 OCCUPANTS TO KNOW THAT THERE IS ANOTHER EXIT ACCESS
 DOOR ON THAT DIRECTION). SEE CLOUDED AREA WITH DELTA
 #2. SEC. 1013.1 FBC-BUILDING.
  
 F)REQUIRED NUMBER OF EXITS SHOWN UNDER CODE DATA IS
 INCORRECT. TWO TWO EXIT ACCESS DOORWAYS ARE REQUIRED
 FROM SUITE 1030. SEC. 1006.2.1 FBC-BUILDING.
  
 2- THIS PERMIT APPLICATION IS FOR THE MULTI-TENANT
 CORRIDOR ALSO. THERE SOME DOORS THAT SWING OUT INTO THE
 CORRIDOR. IT LOOKS LIKE THIS DOORS WILL BLOCK THE
 CORRIDOR MEANS OF EGRESS. NOTE: THIS COMMENT APPLIES TO
 THE MECHANICAL ROOM, CONFERENCE AREA AND STORAGE ROOM.
 REVISE AS REQUIRED ALL PLANS SHOWING THESE DOORS. SEC.
 1005.7.1 FBC-BUILDING.
  
 3- SHEET A1.1.5:
 A)THERE IS A 4'-10" DIMENSION FOR RECESSED DOOR #900E
 AT THE BOTTOM RIGHT OF PLAN. SHOW HOW COMPLYING WITH
 THE 18 INCHES MANEUVERING CLEARANCE REQUIRED BY SEC.
 404.2.4 FBC-ACCESSIBILITY.
  
 B)PROVIDE CALCULATIONS FOR SIZING THE CORRIDOR WIDTH
 AND CAPACITY BASED ON THE OVERALL OCCUPANCY OF ENTIRE
 FLOOR AS REQUIRED BY SEC. 1020.2 FBC-BUILDING.
 NOTE: COORDINATE WITH ITEM #1(D) ABOVE.
  
 4- PROVISO:
 A)SOLAR SHADES TO COMPLY WITH THE TESTS REQUIRED BY
 SECTION 806.4 FBC-BUILDING FOR COMBUSTIBLE DECORATIVE
 MATERIALS EXCEPTION #3 OF SECTION 806.3 FBC-BUILDING
 B)INTERIOR FLOOR-WALL RUBBER BASE BASE TO COMPLY WITH
 TEST REQUIRED BY SECTION 806.8 FBC-BUILDING.
  
 WHEN RESUBMITTING, A TRANSMITTAL LETTER LISTING THE
 ORIGINAL REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF
 THE REVISION MADE, IDENTIFYING THE SHEET OR
 SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND WILL
 HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR
 ANTICIPATED COOPERATION.
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]
  
  

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2021-02-22 Cont ID  
Sent By jleahy Date 2021-02-22 Time 08:15 Rev Time 0.00
Received By jleahy Date 2021-02-19 Time 16:56 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2021-02-11 Cont ID  
Sent By jleahy Date 2021-02-11 Time 13:30 Rev Time 0.00
Received By jleahy Date 2021-02-11 Time 07:40 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2021-01-26 Cont ID  
Sent By jleahy Date 2021-01-26 Time 12:45 Rev Time 0.00
Received By jleahy Date 2021-01-26 Time 10:27 Sent To  
Notes
2021-01-26 12:49:20ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 FLORIDA BUILDING CODE 2017 6TH EDITION
 FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 6TH ED
 NFPA 70 2014 EDITION
  
 JAKE LEAHY BN, BU, PX
 ELECTRICAL PLANS EXAMINER II
 561-805-6713
 [email protected]
  
 BRANCH CIRCUITS FOR THIS SPACE ARE USING THE SAME
 CIRCUIT FOR ANOTHER SPACE 1010 SEE PANEL SCHEDULE TO
 20120426 BOTH ARE FED FROM LA9.
  
  
  

Review Stop E-LOWVOLT ELECTRICAL LOW VOLTAGE
Rev No 1 Status P Date 2021-02-11 Cont ID  
Sent By jleahy Date 2021-02-11 Time 13:29 Rev Time 0.00
Received By jleahy Date 2021-02-11 Time 13:13 Sent To  
Notes
2021-02-11 13:29:50VOICE AND DATA ONLY JLEAHY

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2021-02-23 Cont ID  
Sent By pleduc Date 2021-02-23 Time   Rev Time 0.00
Received By pleduc Date 2021-02-23 Time 11:55 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2021-02-10 Cont ID  
Sent By pleduc Date 2021-02-10 Time   Rev Time 0.00
Received By pleduc Date 2021-02-10 Time 09:26 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2021-01-08 Cont ID  
Sent By pleduc Date 2021-01-08 Time   Rev Time 0.00
Received By pleduc Date 2021-01-06 Time 16:09 Sent To  
Notes
2021-01-08 12:37:04FIRE PROVISO:
  
 THERE IS A DOOR INDICATED FROM THE FUTURE CONFERENCE
 ROOM THAT OPENS OUT INOT THE CORRIDOR POSSIBLE
 OBSTRUCTING EGRESS.
  
 THIS DOOR APPEARS TO OPEN INTO THE PATH OF EGRESS.
 PLEASE REVIEW AND CORRECT IF IN SCOPE OF THIS WORK.
 NFPA 101, CH 7, 7.2.14.3.1 AND PROVIDE AN APPLICABLE
 REVISION.
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2021-03-02 Cont ID  
Sent By lmarchan Date 2021-03-02 Time 16:34 Rev Time 0.00
Received By lmarchan Date 2021-03-02 Time 15:52 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2021-02-23 Cont ID  
Sent By jgomez Date 2021-02-23 Time 13:45 Rev Time 0.00
Received By jgomez Date 2021-02-18 Time 12:29 Sent To I
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2021-02-17 Cont ID  
Sent By lcrespo Date 2021-02-17 Time 10:05 Rev Time 0.00
Received By lcrespo Date 2021-02-10 Time 17:39 Sent To  
Notes
2021-02-10 17:43:33TO BLDG AUDIT ROUND 2
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2021-02-10 Cont ID  
Sent By shill Date 2021-02-10 Time 17:39 Rev Time 0.00
Received By shill Date 2021-02-09 Time 12:15 Sent To  
Notes
2021-02-10 17:43:20TO FIRE REVIEW
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2021-01-29 Cont ID  
Sent By jgomez Date 2021-01-29 Time 16:50 Rev Time 0.00
Received By jgomez Date 2021-01-08 Time 16:32 Sent To I
Notes
2021-02-10 17:43:09BLDG AUDIT

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2021-01-11 Cont ID  
Sent By shill Date 2021-01-11 Time 13:39 Rev Time 0.00
Received By shill Date 2020-12-30 Time 11:29 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status N Date 2020-12-31 Cont ID  
Sent By lmarchan Date 2020-12-31 Time 13:48 Rev Time 0.00
Received By lmarchan Date 2020-12-31 Time 13:48 Sent To  
Notes
2020-12-31 13:48:40IMPACT REVIEW DONE UNDER 18090469

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2021-02-22 Cont ID  
Sent By medwards Date 2021-02-22 Time 06:38 Rev Time 0.00
Received By medwards Date 2021-02-22 Time 06:38 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2021-02-11 Cont ID  
Sent By medwards Date 2021-02-11 Time 09:13 Rev Time 0.00
Received By medwards Date 2021-02-11 Time 09:13 Sent To  
Notes
2021-02-11 09:17:07THE RESPONSE LETTER INDICATES THE CORRECTIONS WERE MADE
 ON REVISED SHEET M6.01. REVISED SHEET M6.01 IS NOT IN
 THIS REVISION UPLOAD. PLEASE UPLOAD THE REVISED SHEET
 FOR REVIEW.
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2021-01-21 Cont ID  
Sent By medwards Date 2021-01-21 Time 11:33 Rev Time 0.00
Received By medwards Date 2021-01-21 Time 10:14 Sent To  
Notes
2021-01-21 11:33:241ST REVIEW FBC-2020 MECHANICAL
 PERMIT-20120427
  
 CODES IN EFFECT:
  
 FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2020
 FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2020
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION
 2020
 FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2020
 FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION
 2020
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH
 EDITION 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2020
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SHEET M6.01- INDICATES A IAQ- VENTILATION DESIGN
 CRITERIA. IF IAQ IS TO BE USED TO REDUCE THE OUTDOOR
 AIR REQUIRED FOR THIS SPACE PLEASE INCLUDE THE IAQ
 CALCULATIONS. FBC M 403.2 (EXCEPTION)
  
 2) SHEET M601- PLEASE PROVIDE OUTDOOR CALCULATIONS
 BASED ON TABLE 403.3.1.1 NOT BASED ON NUMBER OF PEOPLE
 IN ROOM. FBC M 403.3.1.1
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT
 CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE OLD
 SHEETS FROM THE PLAN SETS, BIND THEM TOGETHER
 SEPARATELY AND MARK VOID OR OLD ON THEM. PLEASE RETAIN
 THEM FOR REFERENCE WITH THE NEW SUBMITTED PLANS. THIS
 PROCESS WILL ALSO APPLY TO ANY DOCUMENTS SUCH AS
 PRODUCT APPROVALS OR CALCULATIONS BEING REPLACED OR
 UPDATED.
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop P PLUMBING
Rev No 2 Status P Date 2021-02-17 Cont ID  
Sent By lcrespo Date 2021-02-17 Time 10:04 Rev Time 0.00
Received By lcrespo Date 2021-02-17 Time 09:52 Sent To  
Notes
2021-02-17 10:05:3402/17/21 REVIEWED FOR CODE COMPLIANCE (PLUMBING)
  
 BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE
 COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN
 PROFESSIONAL, CONTRACTORS, OR THEIR REPRESENTATIVES
 FROM THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL,
 STATE, AND NATIONAL CODES AND STANDARDS IN EFFECT AT
 THE TIME OF PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK
 OF EVERY ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM
 REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES
 / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO
 AVOID VOIDING OF THE PERMIT.
  
 LUIS A. CRESPO
 PLUMBING PLAN EXAMINER / INSPECTOR
 EMAIL: [email protected] OFFICE: 561 805-6720
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2021-01-28 Cont ID  
Sent By ccole Date 2021-01-28 Time 15:18 Rev Time 0.00
Received By ccole Date 2021-01-28 Time 15:18 Sent To  
Notes
2021-01-28 15:19:031ST REVIEW FBC-2017 PLUMBING
 PERMIT- 20120427
 1/28/2021
  
 CODES IN EFFECT:
 FBC P- FLORIDA PLUMBING CODE SIXTH EDITION 2017
 FBC ACC- FLORIDA ACCESSIBILITY CODE SIXTH ADDITION 2017
 FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017
 FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION
 2017
 FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017
 FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION
 2017
 FS- F
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2017
  
 PLAN REVIEW RESULTS: DENIED:
  
 1) SHEETS A1.1.1 & A.3.01: PLEASE SHOW THE CLEAR FLOOR
 SPACE PARALLEL APPROACH DIAGRAM AND DIMENSIONS FOR THE
 NEW LOUNGE SINK, DISHWASHER AND ICE MACHINE- SECTIONS
 305.1 & 804.6, & 804.6.3 FBC ACC. DETAIL 2/3.02: SINK
 HEIGHT NOT SHOWN- SECTION 606.3.
  
 2) SHEETS P1.02 & P2.00: PLANS SHOW CONDENSATION FROM
 THE ICE MAKER DRAINING INTO THE SANITARY SYSTEM WHICH
 IS PROHIBITED- SEC. 90-126 WPB CODE OF ORDINANCES. THE
 DRAINAGE SHALL BE DISCHARGED TO AN APPROVED PLACE OF
 DISPOSAL SUCH AS THE STORM DRAINAGE SYSTEM.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop PRIVATEPRV PRIVATE PROVIDER DOCUMENTS
Rev No 4 Status P Date 2021-03-02 Cont ID  
Sent By dbattles Date 2021-03-02 Time 14:00 Rev Time 0.00
Received By dbattles Date 2021-03-02 Time 14:00 Sent To  
Notes
***NONE***

Review Stop PRIVATEPRV PRIVATE PROVIDER DOCUMENTS
Rev No 3 Status F Date   Cont ID  
Sent By   Date 2021-02-22 Time   Rev Time 0.00
Received By   Date 2021-02-22 Time   Sent To  
Notes
2021-02-22 10:45:40FS553, AFFIDAVITS FOR REVISED PAGES WERE NOT SUBMITTED;
 PLEASE UPLOAD
  
  
  

Review Stop PRIVATEPRV PRIVATE PROVIDER DOCUMENTS
Rev No 2 Status F Date 2021-02-16 Cont ID  
Sent By rgathrig Date 2021-02-16 Time 17:40 Rev Time 0.00
Received By rgathrig Date 2021-02-16 Time 17:40 Sent To  
Notes
2021-02-16 17:39:55PRIVATE PROVIDER REVIEW NOT APPROVED
  
 THIS REVIEW WAS FOR THE NOTICE TO BUILDING OFFICIAL AND
 INSPECTOR ONLY. AFIDAVITS FOR PLAN REVIEW COMPLIANCE
 WERE NOT REVIEWED BECAUSE BUILDING AND MECHANICAL TRADE
 FAILED THE 2ND REVIEW AND PLUMBING STILL NEEDS TO BE
 DONE
  
 RICHARD GATHRIGHT
 ABO
 561 805 6679

Review Stop PRIVATEPRV PRIVATE PROVIDER DOCUMENTS
Rev No 1 Status F Date 2021-01-14 Cont ID  
Sent By rgathrig Date 2021-01-14 Time 15:52 Rev Time 0.00
Received By rgathrig Date 2021-01-14 Time 15:52 Sent To  
Notes
2021-01-14 15:53:07PRIVATE PROVIDER REVIEW APPROVED WITH PROVISO
 THIS REVIEW IS FOR THE NOTICE TO BUILDING OFFICIAL,
 INSURANCE LIMITS, PLAN REVIEWERS, AND INSPECTORS ONLY.
 AFFIDAVITS WERE NOT REVIEWED FOR COMPLIANCE WITH THE
 PROJECT PAGES. HOWEVER, IT IS NOTED THAT THE PRIVATE
 PROVIDER WILL NEED TO CORRECT THE FORMAT OF THE
 AFFIDAVITS SUBMITTED TO HAVE HIS SIGNATURE AND
 ATTESTATION FOR ALL THE PAGES IN THE DESIGN DOCUMENTS
 REVIEWED FOR FLORIDA BUILDING CODE COMPLIANCE.
 PLAN REVIEW AFFIDAVITS WILL NEED TO BE REVIEWED AFTER
 THE PLAN REVIEW AUDITS ARE COMPLETE. THIS SUBMITTAL CAN
 MOVE ON TO THE FLORIDA BUILDING CODE REVIEW
  
 RICHARD GATHRIGHT
 ASSISTANT BUILDING OFFICIAL
 5618056679
  
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status P Date 2021-02-22 Cont ID  
Sent By medwards Date 2021-02-22 Time 06:40 Rev Time 0.00
Received By medwards Date 2021-02-22 Time 06:40 Sent To  
Notes
2021-02-19 18:12:41DIGITAL SIGNATURE ON ARCHITECTURAL DWGS IS OK. JG.

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2021-02-13 Cont ID  
Sent By shill Date 2021-02-13 Time 06:27 Rev Time 0.00
Received By shill Date 2021-02-13 Time 06:27 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2021-01-29 Cont ID  
Sent By jgomez Date 2021-01-29 Time 16:50 Rev Time 0.00
Received By jgomez Date 2021-01-29 Time 16:50 Sent To  
Notes
***NONE***