Plan Review Details - Permit 20120292
Plan Review Stops For Permit 20120292
Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2021-02-09 Cont ID  
Sent By medwards Date 2021-02-09 Time 13:49 Rev Time 0.00
Received By medwards Date 2021-02-01 Time 15:27 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2021-02-01 Cont ID  
Sent By lmarchan Date 2021-02-01 Time 09:30 Rev Time 0.00
Received By lmarchan Date 2021-01-19 Time 08:26 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2020-12-18 Cont ID  
Sent By medwards Date 2020-12-18 Time 09:45 Rev Time 0.00
Received By medwards Date 2020-12-08 Time 10:40 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2021-02-09 Cont ID  
Sent By medwards Date 2021-02-09 Time 13:49 Rev Time 0.00
Received By medwards Date 2021-02-09 Time 13:49 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2021-01-29 Cont ID  
Sent By medwards Date 2021-01-29 Time 11:28 Rev Time 0.00
Received By medwards Date 2021-01-29 Time 11:28 Sent To  
Notes
2021-01-29 11:32:38APPROVED WITH PRIVISO:
 THE SPECIFICATIONS FOR THE DUCTSOX MUST BE ONSITE FOR
 THE MECHANICAL INSPECTOR AT THE TIME OF INSPECTION.
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2020-12-18 Cont ID  
Sent By medwards Date 2020-12-18 Time 09:41 Rev Time 0.00
Received By medwards Date 2020-12-18 Time 09:41 Sent To  
Notes
2020-12-18 09:41:481ST REVIEW FBC-2017 MECHANICAL
 PERMIT-20120292
  
 CODES IN EFFECT:
  
 FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017
 FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION
 2017
 FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017
 FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION
 2017
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH
 EDITION 2017
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2017
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) PLEASE SHOW THAT THE CONDENSING UNITS WILL BE
 PROTECTED FROM VEHICULAR TRAFFIC IN THE NEW LOCATIONS.
 FBC M 303.4
  
 2) PLEASE PROVIDE SPECIFICATIONS FOR THE DUCT SOX USED
 IN EACH LOCATION. WHAT TYPE DUCT IS BRANCHING OFF FROM
 THE DUCT SOX? ALSO SHOW THAT THE DUCT SOX ALLOWS
 DUCTWORK TO BE ATTACHED TO IT AS SHOWN WITH AHU-7 ON M2
 DRAWING AND AHU-14 AND AHU-15 ON SHEET M3; AHU-23,
 AHU-24, AHU-25 ON SHEET M4; AHU-36 ON SHEET M8. FBC M
 603.17
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT
 CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE OLD
 SHEETS FROM THE PLAN SETS, BIND THEM TOGETHER
 SEPARATELY AND MARK VOID OR OLD ON THEM. PLEASE RETAIN
 THEM FOR REFERENCE WITH THE NEW SUBMITTED PLANS. THIS
 PROCESS WILL ALSO APPLY TO ANY DOCUMENTS SUCH AS
 PRODUCT APPROVALS OR CALCULATIONS BEING REPLACED OR
 UPDATED.
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status P Date 2021-02-09 Cont ID  
Sent By medwards Date 2021-02-09 Time 13:49 Rev Time 0.00
Received By medwards Date 2021-02-09 Time 13:49 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status F Date 2021-01-29 Cont ID  
Sent By medwards Date 2021-01-29 Time 11:36 Rev Time 0.00
Received By medwards Date 2021-01-29 Time 11:33 Sent To  
Notes
2021-01-29 11:36:46PLEASE RESPOND TO FIRST REVIEW COMMENTS.
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2020-12-18 Cont ID  
Sent By medwards Date 2020-12-18 Time 09:43 Rev Time 0.00
Received By medwards Date 2020-12-18 Time 09:43 Sent To  
Notes
2020-12-18 09:45:01DIGITALLY SUBMITTED PLANS REQUIRE DIGITALLY SUGNED AND
 SEALED AND 3RD PARTY VERIFICATION.
  
 PER THE WPB AMENDMENTS TO THE FBC, EACH SHEET OF PLAN
 (INCLUDING THE SUPPORTING DOCUMENTS) IS REQUIRED TO BE
 SIGNED AND SEALED BY THE PERSON RESPONSIBLE FOR THE
 DESIGN. A DIGITAL PLAN REQUIRES A DIGITAL SIGNATURE
 WITH THE PROPER THIRD PARTY VERIFICATION. PROVIDE
 CORRECTION. ALTERNATIVELY, A SIGNED/SEALED PAPER SET
 MAY BE SUPPLIED TO THE BUILDING DEPARTMENT WHEN ALL
 TRADES ARE APPROVED. WPB FBC 107.1; FS 471/481
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  