Plan Review Details - Permit 20120145
Plan Review Stops For Permit 20120145
Review Stop AD ADDRESSING
Rev No 4 Status P Date 2021-05-03 Cont ID  
Sent By cpuell Date 2021-05-03 Time 10:32 Rev Time 0.00
Received By cpuell Date 2021-05-03 Time 10:32 Sent To  
Notes
2021-05-03 10:35:18TWO NEW STREETS ADDED DUE TO HAVERHILL ENTRANCE BEING
 CUT OFF N PACE DR AND N MORSELIFE DR. THREE BUILDINGS
 READDRESSED NEW ADDRESSES ARE 4881, 4831 & 4355 N PACE
 DR THIS PROJECT ADDRESS GIVEN 4876 N MORSELIFE DR AND
 PHASE TWO WILL HAVE THE ADDRESS OF 4854 N MORSELIFE DR.

Review Stop AD ADDRESSING
Rev No 3 Status F Date 2021-03-23 Cont ID  
Sent By cpuell Date 2021-03-23 Time 11:48 Rev Time 0.00
Received By cpuell Date 2021-03-23 Time 11:48 Sent To  
Notes
2021-03-23 11:49:06WAITING ON DAVID MILLEDGE TO CONFIRM NEW ROAD NAMES.

Review Stop AD ADDRESSING
Rev No 2 Status F Date 2021-01-26 Cont ID  
Sent By cpuell Date 2021-01-26 Time 11:59 Rev Time 0.00
Received By cpuell Date 2021-01-26 Time 11:59 Sent To  
Notes
2021-01-26 12:00:10APPLICANT HAS NOT REACHED OUT TO DISCUSS ADDRESSING,
 PLEASE EMAIL [email protected] TO RESPOND TO FIRST
 COMMENTS.
 NEW BUILDING IN FRONT OF EXCISTING BUILD NEEDS IT'S OWN
 ADDRESS, PLEASE EMAIL [email protected] TO DISCUSS ADDRESS
 OPTIONS. PLEASE EMAIL A SITE PLAN SHOWING THE MAIN
 ENTRANCE TO THE BUILDING,

Review Stop AD ADDRESSING
Rev No 1 Status F Date 2020-12-03 Cont ID  
Sent By cpuell Date 2020-12-03 Time 17:23 Rev Time 0.00
Received By cpuell Date 2020-12-03 Time 17:23 Sent To  
Notes
2020-12-03 17:26:27NEW BUILDING IN FRONT OF EXCISTING BUILD NEEEDS IT'S
 OWN ADDRESS, PLEASE EMAIL [email protected] TO DISCUSS
 ADDRESS OPTIONS. PLEASE EMAIL A SITE PLAN SHOWING THE
 MAIN ENTRANCE TO THE BUILDING,

Review Stop AIPP ART IN PUBLIC PLACES
Rev No 2 Status P Date 2022-10-13 Cont ID  
Sent By swelter Date 2022-10-13 Time 10:58 Rev Time 0.00
Received By swelter Date 2022-10-13 Time 11:02 Sent To  
Notes
2022-10-13 11:01:55-DEVELOPER SATISFIED PUBLIC ART REQUIREMENT OPTION 2
 10.12.2022

Review Stop AIPP ART IN PUBLIC PLACES
Rev No 1 Status F Date 2022-09-06 Cont ID  
Sent By scwelter Date 2022-09-06 Time 10:52 Rev Time 0.00
Received By scwelter Date 2022-09-06 Time 11:02 Sent To  
Notes
2022-09-06 11:02:08SENT OSMAN AGUILERA AN EMAIL TO COMPLETE THE ART
 ASSESSMENT - CONTRIBUTE .75% OF 1 % - DUE NOW.
  
 MASTER 20120145
 $8,000,000
 1% $ 80,000
 (-25%)
 $60,000
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2021-04-08 Cont ID  
Sent By rmcphers Date 2021-04-08 Time 13:16 Rev Time 0.00
Received By rmcphers Date 2021-04-08 Time 11:02 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2021-02-26 Cont ID  
Sent By mcphers Date 2021-02-26 Time 13:13 Rev Time 0.00
Received By rmcphers Date 2021-02-25 Time 14:59 Sent To  
Notes
2021-02-26 12:59:23NEW 2 STORY OFFICE AND DAYCARE
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected]
 CODE USED FOR REVIEW - 2017 FBC WITH WPB CHAPTER 1
 AMENDMENTS
  
 CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107
 1) I MISSED THIS ON THE FIRST REVIEW - RESTROOM DOOR
 (P131) DOES NOT APPEAR TO HAVE THE REQUIRED 18" BESIDE
 THE DOOR TO EXIT THE RESTROOM - PLEASE SHOW THE DOOR
 MANUVERING CLEARANCE FROM THE INSIDE OF THE RESTROOM
 (18" BESIDE THE DOOR) - FBC ACCESSIBILITY 206.5.2 ROOMS
 AND SPACES. WITHIN A BUILDING OR FACILITY, AT LEAST ONE
 DOOR, DOORWAY, OR GATE SERVING EACH ROOM OR SPACE
 COMPLYING WITH THESE REQUIREMENTS SHALL COMPLY WITH
 404.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2021-01-04 Cont ID  
Sent By rmcphers Date 2021-01-04 Time 14:07 Rev Time 0.00
Received By rmcphers Date 2020-12-30 Time 12:59 Sent To  
Notes
2021-01-04 13:30:22NEW 2 STORY OFFICE/DAYCARE
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected]
 CODE USED FOR REVIEW - 2017 FBC WITH WPB CHAPTER 1
 AMENDMENTS
  
 CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107
 1) EXISTING BUILDING DEMO NEEDS TO BE ON A SEPARATE
 PERMIT WITH A SEPARATE PERMIT NUMBER - PLEASE
 ACKNOWLEDGE THIS REQUIREMENT.
 2) SEPARATE PERMIT IS REQUIRED FOR PAVING/PARKING.
 3) PLEASE PROVIDE A COMPLETE MIAMI DADE OR FLORIDA
 STATE PRODUCT APPROVAL FOR THE ROOFING SYSTEM AND SUB
 PERMIT APPLICATION FOR THE ROOFING.
 4) PLEASE PROVIDE A COMPLETE MIAMI DADE OR FLORIDA
 STATE PRODUCT APPROVAL FOR THE EXTERIOR WINDOWS, DOORS,
 LOUVERS ETC.
 5) ALL PRODUCT APPROVALS AND SHOP DRAWINGS NEED TO BE
 REVIEWED AND MARKED APPROVED BY THE BUILDING DESIGNER
 OF RECORD.
 6) PLEASE PROVIDE A COPY OF THE SIGNED AND SEALED SOIL
 REPORT.
 7) ROOFING SUBMITTAL AND WINDOW AND DOOR PRODUCT
 APPROVALS MAY BE DEFERRED SUBMITTALS BY LISTING ITEMS
 TO BE DEFERRED ON THE CONSTRUCTION DOCUMENTS -
 107.3.4.1 DEFERRED SUBMITTALS. FOR THE PURPOSES OF THIS
 SECTION, DEFERRED SUBMITTALS ARE DEFINED AS THOSE
 PORTIONS OF THE DESIGN THAT ARE NOT SUBMITTED AT THE
 TIME OF THE APPLICATION AND THAT ARE TO BE SUBMITTED TO
 THE BUILDING OFFICIAL WITHIN A SPECIFIED PERIOD.
 DEFERRAL OF ANY SUBMITTAL ITEMS SHALL HAVE THE PRIOR
 APPROVAL OF THE BUILDING OFFICIAL. THE REGISTERED
 DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE SHALL LIST
 THE DEFERRED SUBMITTALS ON THE CONSTRUCTION DOCUMENTS
 FOR REVIEW BY THE BUILDING OFFICIAL. DOCUMENTS FOR
 DEFERRED SUBMITTAL ITEMS SHALL BE SUBMITTED TO THE
 REGISTERED DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE
 WHO SHALL REVIEW THEM AND FORWARD THEM TO THE BUILDING
 OFFICIAL WITH A NOTATION INDICATING THAT THE DEFERRED
 SUBMITTAL DOCUMENTS HAVE BEEN REVIEWED AND FOUND TO BE
 IN GENERAL CONFORMANCE TO THE DESIGN OF THE BUILDING.
 THE DEFERRED SUBMITTAL ITEMS SHALL NOT BE INSTALLED
 UNTIL THE DEFERRED SUBMITTAL DOCUMENTS HAVE BEEN
 APPROVED BY THE BUILDING OFFICIAL.

Review Stop E ELECTRICAL
Rev No 4 Status P Date 2021-06-04 Cont ID  
Sent By jleahy Date 2021-06-04 Time 07:40 Rev Time 0.00
Received By jleahy Date 2021-06-03 Time 14:07 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2021-04-07 Cont ID  
Sent By jleahy Date 2021-04-07 Time 16:25 Rev Time 0.00
Received By jleahy Date 2021-04-06 Time 13:19 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2021-02-18 Cont ID  
Sent By jleahy Date 2021-02-18 Time 08:58 Rev Time 0.00
Received By jleahy Date 2021-02-16 Time 14:29 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2021-01-07 Cont ID  
Sent By jleahy Date 2021-01-07 Time 08:42 Rev Time 0.00
Received By jleahy Date 2021-01-05 Time 15:20 Sent To  
Notes
2021-01-07 08:52:57ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 FLORIDA BUILDING CODE 2017 6TH EDITION
 FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 6TH ED
 NFPA 70 2014 EDITION
  
 JAKE LEAHY BN, BU, PX
 ELECTRICAL PLANS EXAMINER II
 561-805-6713
 [email protected]
  
 PAGE E.2.2.1
  
 ROOMS P120, P121, P122 WILL REQUIRE GFCI PROTECTION OF
 ALL 125V 15A, AND 20A RECEPTACLE OUTLETS.
 ALL 125-VOLT, SINGLE-PHASE, 15- AND 20-AMPERE
 RECEPTACLES INSTAL LED IN THE LOCATIONS SPECIFIED IN
 210.8(B)(1) THROUGH (8) SHALL HAVE GROUND-FAULT CIRCUIT
 INTERRUPTER PROTECTION FOR PERSONNEL.
  
 PAGE E.2.2.2
  
 ROOMS P108B, P108C, P127, P135, P136, P137 ARE THESE
 ROOMS TREATMENT ROOMS THAT SHOULD BE COVERED BY ARTICLE
 517?
 517.1 SCOPE THE PROVISIONS OF THIS ARTICLE SHALL APPLY
 TO ELECTRICAL CONSTRUCTI ON AND INSTALLATION CRITERIA
 IN HEALTH CARE FACILITIES THAT PROVIDE SERVICES TO
 HUMAN BEINGS. THE REQUIREMENTS IN PARTS II AND III NOT
 ONLY APPLY TO SINGLEFUNCTION BUILDINGS BUT ARE ALSO
 INTENDED TO BE INDIVIDUALLY APPLIED TO THEIR RESPECTIVE
 FORMS OF OCCUPANCY WITHIN A MULTIFUNCTION BUILDING
 (E.G., A DOCTOR?S EXAMINING ROOM LOCATED WITHIN A
 LIMITED CARE FACILITY WOULD BE REQUIRED TO MEET THE
 PROVISIONS OF 517.10).
  
  

Review Stop E-LOWVOLT ELECTRICAL LOW VOLTAGE
Rev No 1 Status P Date 2021-06-07 Cont ID  
Sent By jleahy Date 2021-06-07 Time 17:32 Rev Time 0.00
Received By jleahy Date 2021-06-07 Time 17:32 Sent To  
Notes
2021-06-07 17:33:38VOICE AND DATA JLEAHY

Review Stop ENG ENGINEERING CSD
Rev No 3 Status P Date 2021-05-18 Cont ID  
Sent By rrossano Date 2021-05-18 Time   Rev Time 0.00
Received By rrossano Date 2021-05-18 Time   Sent To  
Notes
2021-05-18 10:30:20REVIEWED UNDER FORMAL ENG SUBMITTAL E20060022.

Review Stop ENG ENGINEERING CSD
Rev No 2 Status F Date 2021-02-01 Cont ID  
Sent By rrossano Date 2021-02-01 Time   Rev Time 0.00
Received By rrossano Date 2021-02-01 Time   Sent To  
Notes
2021-02-01 13:36:37UNDER REVIEW AS FORMAL ENG. SUBMITTAL E20060022.

Review Stop ENG ENGINEERING CSD
Rev No 1 Status F Date 2020-12-08 Cont ID  
Sent By rrossano Date 2020-12-08 Time   Rev Time  
Received By rrossano Date 2020-12-08 Time   Sent To  
Notes
2020-12-08 09:50:48UNDER REVIEW AS FORMAL ENGINEERING SUBMITTAL E20060022.

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2021-03-23 Cont ID  
Sent By pleduc Date 2021-03-23 Time   Rev Time 0.00
Received By pleduc Date 2021-03-23 Time 11:32 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2021-01-29 Cont ID  
Sent By pleduc Date 2021-01-29 Time   Rev Time 0.00
Received By pleduc Date 2021-01-27 Time 13:15 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2020-12-09 Cont ID  
Sent By pleduc Date 2020-12-09 Time   Rev Time 0.00
Received By pleduc Date 2020-12-09 Time 10:34 Sent To  
Notes
2020-12-09 11:24:19THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE
 MARSHAL, WITH THE FOLLOWING COMMENTS:
  
  
 1) SHEET LS 1.1 - THERE IS NO INDICATION OF COMPLIANCE
 OR REVIEW WITH THE REQUIREMENTS OF THE FLORIDA FIRE
 PREVENTION CODE.
  
 THE PROPOSED SHALL COMPLY WITH THE REQUIREMENTS OF THE
 6TH EDITION OF FLORIDA FIRE PREVENTION CODE WHICH
 INCLUDES THE 2015 EDITION OF NFPA 1 AND NFPA 101.
  
 PLEASE PROVIDE AN APPLICABLE NOTE OF ACKNOWLEDGEMENT,
 REVIEW, AND COMPLIANCE.
  
 THE BELOW LIST ARE THE MOST COMMON REFERENCED CODES:
  
 FIRE SPRINKLER WORK SHALL COMPLY WITH THE REQUIREMENTS
 OF NFPA 13, 2013 EDITION.
 UNDERGROUND WORK SAHLL COMPLY WITH NFPA 24, 2013
 EDITION.
 FIRE ALARM WORK SHALL COMPLY WITH THE REQUIREMENTS OF
 NFPA 72, 2013 EDITION.
 CONSTRUCTION WORK SHALL COMPLY WITH THE REQUIREMENTS OF
 NFPA 241, 2013 EDITION.
 FIRE EXTINGUISHERS SHALL COMPLY WITH THE REQUIREMENTS
 OF NFPA 10, 2013 EDITION.
 ELECTRIC WORK SHALL COMPLY WITH NFPA 70, 2014 EDITION.
 EMERGENCY AND STANDBY POWER SYSTEMS SHALL COMPLY WITH
 NFPA 110, 2013 EDITION.
 COMMERCIAL COOKING SHALL COMPLY WITH NFPA 96, 2014
 EDITION.
 AIR CONDITION WORK SHALL COMPLY WITH NFPA 90 A & B,
 2015 EDITION
  
  
  
 2) SHEET FP 1.1.1 - THERE IS UNDERGROUND FIRE LINE
 INDICATED.
  
 ALL UNDERGROUND FIRE LINE WORK SHALL BE SUBMITTED UNDER
 SEPARATE PERMIT AND SHOP DRAWINGS, INCLUDING
 EQUIPMENT/PRODUCT SPEC SHEETS.
  
 PLEASE PROVIDE A NOTE OF ACKNOWLEDGEMENT.
  
  
  
 2A) SHEET FP 1.1.1 - THE IS AN INDICATION OF A PROPOSED
 FDC LOCATION.
  
 DUE TO PROPOSED FUTURE BUILDING AND THE LOCATION OF THE
 PORTE COCHE, IT IS RECOMMENDED THAT THE FDC BE MOVED TO
 THE SAME SIDE OF THE PORTE COCHE(SOUTH) AND FIRE
 HYDRANT(EAST SIDE OF DRIVE PATH).
  
 PLEASE REVIEW AND CORRECT OR PROVIDE A COMMENT TO
 CONTINUE TO COORDINATE WITH THE FIRE MARSHAL'S OFFICE
 PRIOR TO UNDERGROUND PERMIT SUBMITTAL.
  
  
 3) SHEET E 2.3..1 & E 2.3.2 - THERE ARE INDICATIONS OF
 FIRE ALARM EQUIPMENT/DEVICES.
  
 ALL FIRE ALARM WORK SHALL BE SUBMITTED UNDER SEPARATE
 PERMIT AND SHOP DRAWINGS, INCLUDING EQUIPMENT/PRODUCT
 SPEC SHEETS.
  
 PLEASE PROVIDE A NOTE OF ACKNOWLEDGEMENT.
  
  
 4) ELECTRICAL SHEETS - THERE ARE NO INDICATIONS OF A
 RADIO FREQUENCY TWO- WAY EMERGENCY COMMUNICATION
 COMPLIANCE.
  
 PER NFPA 1 - CH 11 BUILDING SERVICES
  
 11.10* TWO-WAY RADIO COMMUNICATION ENHANCEMENT SYSTEMS.
 11.10.1 IN ALL NEW AND EXISTING BUILDINGS, MINIMUM
 RADIO SIGNAL
 STRENGTH FOR FIRE DEPARTMENT COMMUNICATIONS SHALL BE
 MAINTAINED AT A
 LEVEL DETERMINED BY THE AHJ.
 11.10.2 WHERE REQUIRED BY THE AHJ, TWO-WAY RADIO
 COMMUNICATION
 ENHANCEMENT SYSTEMS SHALL COMPLY WITH NFPA 72.
 11.10.3 WHERE A TWO-WAY RADIO COMMUNICATION ENHANCEMENT
 SYSTEM IS
 REQUIRED AND SUCH SYSTEM, COMPONENTS, OR EQUIPMENT HAS
 A NEGATIVE
 IMPACT ON THE NORMAL OPERATIONS OF THE FACILITY AT
 WHICH IT IS INSTALLED,
 THE AHJ SHALL HAVE THE AUTHORITY TO ACCEPT AN
 AUTOMATICALLY ACTIVATED
 RESPONDER SYSTEM.
  
 ANY ENHANCEMENT SYSTEM (BDA) SHALL BE INSTALLED UNDER
 SEPARATE PEMRIT AND SHOP DRAWINGS.
  
 PLEASE REVIEW AND PROVIDE A NOTE OF ACKNOWLEDGEMENT
  
  
  
 5) SHEET A 1.1.0 - THERE APPEARS TO BE GENERATOR WITHIN
 THE OPEN MECHANICAL YARD.
  
 PLEASE REVIEW AND CONFIRM, SIZE AND TYPE.
  
 THE GENERATOR SHALL BE INSTALLED UNDER SEPARATE PERMIT
 AND SHOP DRAWINGS IN COMPLIANCE WITH ALL APPLICABLE
 CODES INCLUDING NFPA 110 AND NFPA 37.
  
 PLEASE REVIEW AND PROVIDE A NOTE OF ACKNOWLEDGEMENT
  
  
  
 6) SHEETS E 2.3.1, 2.3.2 & 2.3.3 - THERE APPEARS TO BE
 PROPOSED ACCESS CONTROL.
  
 ACCESS CONTROL SHALL BE INSTALLED UNDER SEPARATE PERMIT
 AND SHOP DRAWINGS IN COMPLIANCE WITH ALL APPLICABLE
 CODES INCLUDING NFPA 101, CH 7 MEANS OF EGRESS.
  
 PLEASE REVIEW AND PROVIDE A NOTE OF ACKNOWLEDGEMENT
  
  
  
 7) SHEET A 1.2.7 - THE PORTE COCHERE INDICATES A
 DIMENSIONAL HEIGHT OF 12.0'
  
 PER NFPA 1 CH 18 FIRE DEPARTMENT ACCESS AND WATER
 SUPPLY
  
 18.1 GENERAL. FIRE DEPARTMENT ACCESS AND WATER SUPPLIES
 SHALL
 COMPLY WITH THIS CHAPTER.
 18.1.1 APPLICATION.
 18.1.1.1 THIS CHAPTER SHALL APPLY TO PUBLIC AND
 PRIVATELY OWNED
 FIRE APPARATUS ACCESS ROADS.
 18.1.1.2 THIS CHAPTER SHALL APPLY TO PUBLIC AND
 PRIVATELY OWNED
 FIRE HYDRANT SYSTEMS.
  
 18.2.3.4 SPECIFICATIONS.
 18.2.3.4.1 DIMENSIONS.
  
 18.2.3.4.1.2 FIRE DEPARTMENT ACCESS ROADS SHALL HAVE AN
 UNOBSTRUCTED
 VERTICAL CLEARANCE OF NOT LESS THAN 13 FT 6 IN. (4.1
 M).
  
  
 PLEASE REVIEW AND CORRECT.
  
  
  
 8) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET
 REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE
 ABOVE.
  
  
  
 9) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE
 RE-SUBMITTAL OF THE ABOVE.
  
  
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date   Cont ID  
Sent By   Date 2021-06-08 Time   Rev Time 0.00
Received By aoliver Date 2021-05-17 Time 09:12 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2021-04-29 Cont ID  
Sent By lmarchan Date 2021-04-29 Time 11:07 Rev Time 0.00
Received By lmarchan Date 2021-03-22 Time 17:09 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2021-02-26 Cont ID  
Sent By rmcphers Date 2021-02-26 Time 13:14 Rev Time 0.00
Received By rmcphers Date 2021-01-25 Time 10:41 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2021-01-20 Cont ID  
Sent By lmarchan Date 2021-01-20 Time 16:39 Rev Time 0.00
Received By lmarchan Date 2020-12-03 Time 14:33 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status P Date 2021-06-17 Cont ID  
Sent By lmarchan Date 2021-06-17 Time 14:42 Rev Time 0.00
Received By lmarchan Date 2021-06-08 Time 08:35 Sent To  
Notes
2021-06-16 10:14:50RECEIPT MU-2021-028840 - $66,335.03 PAID
2021-06-08 08:35:286/8/21 EMAILED IMPACT FEE OFFICE FOR REVIEW. LEM

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2021-01-04 Cont ID  
Sent By rmcphers Date 2021-01-04 Time 14:07 Rev Time 0.00
Received By rmcphers Date 2021-01-04 Time 14:07 Sent To  
Notes
2021-01-04 14:08:11PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE
 DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS
 OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST
 FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE
 OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL
 IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME
 THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM
 CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS
 TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF
  
 UPON APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE
 RECEIPT TO YOUR PROJECT OR EMAIL IT TO
 [email protected] .
  

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2021-02-11 Cont ID  
Sent By medwards Date 2021-02-11 Time 07:16 Rev Time 0.00
Received By medwards Date 2021-02-09 Time 08:59 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2020-12-23 Cont ID  
Sent By medwards Date 2020-12-23 Time 14:12 Rev Time 0.00
Received By medwards Date 2020-12-23 Time 08:40 Sent To  
Notes
2020-12-23 14:12:191ST REVIEW FBC-2017 MECHANICAL
 PERMIT-20120145
  
 CODES IN EFFECT:
  
 FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017
 FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION
 2017
 FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017
 FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION
 2017
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH
 EDITION 2017
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2017
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SHEET M0.0.2: (AHU-1-1) MULTIPURPOSE ASSEMBLY
 CALCULATIONS SHOULD BE:
 6127 SQ FT/1000 = 6.127; 6.127 X 120 = 735.24 X 5 =
 3676.2 + 6127 X .06 = 367.62
 3676.2 + 367.62 = 4044 CFM OF OUTDOOR AIR. FBC M TABLE
 403.3.1.1
  
 2) PLEASE ADJUST ALL CALCULATIONS THAT ARE BASED ON THE
 AHU-1-1 OUTDOOR AIR CALCULATIONS. FBC 107.2.1
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT
 CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE OLD
 SHEETS FROM THE PLAN SETS, BIND THEM TOGETHER
 SEPARATELY AND MARK VOID OR OLD ON THEM. PLEASE RETAIN
 THEM FOR REFERENCE WITH THE NEW SUBMITTED PLANS. THIS
 PROCESS WILL ALSO APPLY TO ANY DOCUMENTS SUCH AS
 PRODUCT APPROVALS OR CALCULATIONS BEING REPLACED OR
 UPDATED.
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop P PLUMBING
Rev No 4 Status P Date 2021-06-07 Cont ID  
Sent By ccole Date 2021-06-07 Time 17:32 Rev Time 0.00
Received By ccole Date 2021-06-07 Time 10:20 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status F Date 2021-04-12 Cont ID  
Sent By ccole Date 2021-04-12 Time 12:19 Rev Time 0.00
Received By ccole Date 2021-04-09 Time 14:49 Sent To  
Notes
2021-04-12 12:19:283RD REVIEW FBC-2017 PLUMBING
 PERMIT- 20120145
 4/12/2021
  
 CODES IN EFFECT:
 FBC P- FLORIDA PLUMBING CODE SIXTH EDITION 2017
 FBC ACC- FLORIDA ACCESSIBILITY CODE SIXTH ADDITION 2017
 FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017
 FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION
 2017
 FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017
 FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION
 2017
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2017
  
 PLAN REVIEW RESULTS: DENIED.
 COMMENTS FROM THE 1ST AND 2ND REVIEW LISTED BELOW HAVE
 NOT BEEN COMPLETELY RESOLVED. NOTES HAVE BEEN ADDED FOR
 FURTHER CLARIFICATION.
  
 3) FAILED. A1.6.1 & P DRAWINGS: BASED ON THE SERVING
 KITCHEN PLAN IT APPEARS THAT A GREASE INTERCEPTOR MUST
 BE PROVIDED TO RECEIVE THE DRAINAGE FROM THE HOT FOOD
 WELL, DISHWASHER, FOOD WASTE DISPOSAL, AND ALL DIRECT
 OR INDIRECT WASTE RECEPTORS SERVING KITCHEN APPLIANCES
 AND EQUIPMENT THAT PRODUCE GREASE OR FAT-LADEN WASTE
 EFFLUENTS- SEE SECTION 1003.3.1 FBC P. CONCERNING THE
 FOOD WASTE DISPOSAL REFER TO SECTION 1003.3.2 FBC P AND
 PROVIDE A SOLIDS INTERCEPTOR TO SEPARATE THE DISCHARGE
 BEFORE CONNECTING TO THE INTERCEPTOR. SHEETS P2.1.1 &
 P4.1.1: THE ARCHITECT'S RESPONSE INDICATES A GREASE
 INTERCEPTOR TO BE INSTALLED UNDER THE KITCHEN SINK
 HOWEVER NOTE 8 ON SHEET P.2.1.1 SPECIFIES A SOLIDS
 INTERCEPTOR EQUAL TO STRIEM MODEL #HTL-1176-1. PLEASE
 NOTE THAT HTL-1176-1 IS A HAIR AND LINT INTERCEPTOR.
 PLEASE PROVIDE THE CORRECT INTERCEPTOR MAKE AND MODEL
 AND SUBMIT MANUFACTURER'S SPECIFICATIONS. SOLIDS
 INTERECPTORS ARE REQUIRED FOR FOOD WASTE DISPOSERS
 CONNECTING TO GREASE INTERCEPTORS- SECTION 1003.3.2.
  
 7) A1.6.4 & A1.6.5: ACCESSIBLE SHOWER:
  
 C) FAILED. LOCATION OF CONTROL, FAUCET, AND SHOWER
 SPRAY IN THE SHOWER- SECTION 608.5.2 FBC ACC. WHERE A
 SEAT IS PROVIDED, THE CONTROLS, FAUCETS, AND SHOWER
 SPRAY UNIT SHALL BE INSTALLED ON THE BACK WALL ADJACENT
 TO THE SEAT WALL AND SHALL BE LOCATED 27 INCHES MAXIMUM
 FROM THE SEAT WALL. DETAILS ON THE SHEETS SHOW THE
 CONTROLS ON THE SIDE WALL.
  
 E) FAILED SHOWER SEAT DIMENSIONS, HEIGHT, CLEARANCES
 AND EXTENSIONS AS OUTLINED IN SECTIONS 610.3 & 610.3.2.
 THE 2 FT. SHOWER SEAT DIMENSION EXCEEDS THE MAX 23
 INCHES ALLOWED AS SHOWN IN FIGURE 610.3.2. PLEASE
 CORRECT THE DETAIL AND PROVIDE COMPLETE DIMENSIONS.
  
 33) FAILED. PLEASE NOTE SEPARATE PERMIT APPLICATIONS
 AND PLANS ARE REQUIRED FOR THE POTABLE WATER SERVICE
 BACKFLOW PREVENTER, BACKFLOW PREVENTER FOR THE CHILLER,
 IRRIGATION SYSTEM, FIRE LINE, FIRE LINE BACKFLOW
 PREVENTER, AND FIRE SPRINKLER SYSTEM. COMPLETE SETS OF
 PLANS AND SPECIFICATIONS ARE REQUIRED FOR REVIEW AND
 PERMIT ISSUANCE- SECTION 107.2.1 WPB. PROVIDE A LIST OF
 SEPARATE PERMITS ON THE PLANS INCLUDING THE RELOCATION
 OF BF PREVENTERS SHOWN ON C09.
  
 A) FAILED. BACKFLOW PREVENTERS: PLEASE NOTE THAT FL.
 LICENSED PLUMBING CONTRACTORS SHALL OBTAIN SEPARATE
 PERMITS FOR INSTALLATION OF THE BACKFLOW PREVENTERS IN
 ACCORDANCE WITH SECTION 105.1 WPB AND SEC. 90-33 WPB
 CODE OF ORDINANCES. THE DEVICES SHALL BE TESTED AND
 CERTIFIED BY THE WPB UTILITIES DEPARTMENT PRIOR TO
 FINAL INSPECTION BY THE BUILDING DEPARTMENT. PLEASE
 CONTACT THE WPB UTILITIES CENTRAL OPERATIONS DEPT.AT
 561-822-2210 FOR FURTHER INFORMATION. SEE COMMENT #33.
  
 B) FAILED. GREASE INTERCEPTOR: SUBMITTED PLANS SHALL
 INCLUDE GREASE WATER CALCULATIONS IN ACCORDANCE WITH
 SECTION 1003.3.4 FOR HYDROMECHANICAL INTERCEPTORS OR
 1003.3.6 FOR GRAVITY TYPE INTERCEPTORS. MANUFACTURER'S
 SPECIFICATIONS AND INSTALLATION MANUALS SHALL ALSO BE
 SUBMITTED FOR REVIEW. SEE ADDED NOTES UNDER COMMENT #3
 ABOVE.
  
 NEW COMMENT.
  
 1) SHEET A1.64: THE DOOR TO THE WOMEN'S TLT. (P131)
 SHALL NOT SWING INTO THE CLEAR FLOOR SPACE FOR THE
 LAVATORY- SECTION 603.2.3 FBC ACC.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop P PLUMBING
Rev No 2 Status F Date 2021-02-17 Cont ID  
Sent By ccole Date 2021-02-17 Time 12:46 Rev Time 0.00
Received By ccole Date 2021-02-16 Time 07:23 Sent To  
Notes
2021-02-17 12:46:422ND REVIEW FBC-2017 PLUMBING
 PERMIT- 20120145
 2/16//2021
  
 CODES IN EFFECT:
 FBC P- FLORIDA PLUMBING CODE SIXTH EDITION 2017
 FBC ACC- FLORIDA ACCESSIBILITY CODE SIXTH ADDITION 2017
 FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017
 FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION
 2017
 FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017
 FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION
 2017
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2017
  
 PLAN REVIEW RESULTS: DENIED.
 COMMENTS FROM THE 1ST REVIEW THAT HAVE PASSED ARE
 REMOVED. FAILED COMMENTS FROM THE 1ST REVIEW BELOW ARE
 MARKED FAILED WITH ADDITIONAL NOTES. ADDITIONAL NOTES
 HAVE BEEN ADDED TO SOME PASSED COMMENTS.
  
 1) FAILED. SHEETS LS1.1 & LS1.2: PLEASE INCLUDE THE
 REQUIRED SERVICE SINKS IN THE PLUMBING FIXTURE
 CALCULATIONS- TABLE 403.1 FBC P. THREE SERVICE SINKS
 ARE REQUIRED FOR THE FACILITY. BASED ON TABLE 403.1 AND
 THE OCCUPANT LOAD IN PERCENTAGES: BUSINESS- 2.71 +
 ASSEMBLY- .194 = 2.904. MINIMUM 3 SERVICE SINKS. PLEASE
 REVISE THE PLANS ACCORDINGLY.
  
 3) FAILED. A1.6.1 & P DRAWINGS: BASED ON THE SERVING
 KITCHEN PLAN IT APPEARS THAT A GREASE INTERCEPTOR MUST
 BE PROVIDED TO RECEIVE THE DRAINAGE FROM THE HOT FOOD
 WELL, DISHWASHER, FOOD WASTE DISPOSAL, AND ALL DIRECT
 OR INDIRECT WASTE RECEPTORS SERVING KITCHEN APPLIANCES
 AND EQUIPMENT THAT PRODUCE GREASE OR FAT-LADEN WASTE
 EFFLUENTS- SEE SECTION 1003.3.1 FBC P. CONCERNING THE
 FOOD WASTE DISPOSAL REFER TO SECTION 1003.3.2 FBC P AND
 PROVIDE A SOLIDS INTERCEPTOR TO SEPARATE THE DISCHARGE
 BEFORE CONNECTING TO THE INTERCEPTOR. BASED ON THE
 NARRATIVE RESPONSE TO COMMENTS, PLEASE PLACE A NOTE ON
 THE PLANS INDICATING NO FOOD PREPPARATION OR COOKING OF
 MEATS, FISH OR OTHER GREASE PRODUCING FOODS ALLOWED IN
 THE SERVING KITCHEN WITHOUT INSTALLATION OF A GREASE
 TRAP.
  
 4) FAILED. A1.6.1, P0.0.1, & P2.1.1: THE SERVING
 KITCHEN SHOWS AN FD UNDER THE HOT FOOD WELL AND OTHER
 FLOOR DRAINS THAT ARE NOT INCLUDED IN THE FIXTURE
 SCHEDULE. CONCERNING THE FLOOR DRAIN SERVING THE FOOD
 WELL REFER TO SECTIONS 802.1 & 802.3: OTHER THAN HUB
 DRAINS THAT RECEIVE ONLY CLEAR-WATER WASTE AND
 STANDPIPES, A REMOVABLE STRAINER OR BASKET SHALL COVER
 THE OUTLET OF WASTE RECEPTORS. THE DISHWASHER SHALL
 ALSO DISCHARGE TO THE DRAINAGE SYSTEM THROUGH AN
 INDIRECT WASTE PIPE- PLEASE SECTIONS AND 802.3.1,
 802.3.2 AND 427.1 FOR INDIRECT WASTE RECEPTOR
 COMPLIANCES. THE PLANS ALSO SHOW AN ICE MAKER AND
 BEVERAGE DISPENSERS IN THE KITCHEN WITH NO INDIRECT
 WASTE RECEPTORS BELOW THEM TO RECEIVE CONDENSATE
 DRAINAGE- SECTION 802.1 FBC P. PLEASE NOTE THAT
 CONDENSATE FROM COOLING COILS SHALL NOT DRAIN INTO THE
 CITY SANITARY SYSTEM- SECTION 90-126 WPB CODE OF
 ORDINANCES. CONCERNING THE ICE MAKER HOW IS THIS ISSUE
 BEING ADDRESSED? WILL THE UNIT PRODUCE CONDENSATE?
  
 7) A1.6.4 & A1.6.5: ACCESSIBLE SHOWER, FBC ACC. SHEET
 A1.6.5 WITH SHOWER DETAILS WAS NOT UPLOADED PROPERLY
 AND CANNOT BE VIEWED.
  
 A) PASSED. CLEAR FLOOR SPACE DIAGRAM AND DIMENSIONS FOR
 THE SHOWER- SECTION 608.2.1
 B) FAILED. LOCATIONS, LENGTHS, AND MOUNTING HEIGHTS OF
 GRAB BARS- SECTION 608.3 AND 608.3.1.
 C) FAILED. LOCATION OF CONTROL, FAUCET, AND SHOWER
 SPRAY IN THE SHOWER- SECTION 608.5.1.
 D) FAILED. SHOWER SPRAY UNIT SPECIFICATIONS PER SECTION
 608.6.
 E) PASSED. SHOWER SEAT DIMENSIONS, HEIGHT, CLEARANCES
 AND EXTENSIONS AS OUTLINED IN SECTIONS 610.3 & 610.3.2.
 9) FAILED. SINKS- P0.0.1: REFER TO SECTION 212.3 FBC
 ACC WHICH REQUIRES A MINIMUM OF 5%, BUT NO FEWER THAN
 ONE SINK OF EACH TYPE TO BE ACCESSIBLE. THIS WOULD
 INCLUDE THE L1, S1, S2, S3, S4, & S5 IN USE THROUGHOUT
 THE FACILITY. PLEASE DESIGNATE WHICH SINKS WILL BE MADE
 ACCESSIBLE BY SHOWING THE CLEAR FLOOR SPACE DIAGRAM AND
 DIMENSIONS AT EACH LOCATION ON THE ARCHITECTURAL AND
 PLUMBING DRAWINGS- SECTION 606.2. PROVIDE ELEVATION
 VIEWS FOR EACH ACCESSIBLE SINK SHOWING COMPLIANCE WITH
 SECTIONS 606.3, 306, 308, 309- HEIGHTS FROM FINISHED
 FLOORS, KNEE AND TOE CLEARANCES, REACH RANGE TO FAUCET
 CONTROLS, AND OPERABLE PARTS. THE ARCHITECTURAL FLOOR
 PLANS WERE NOT REVISED TO SHOW THE CLEAR FLOOR SPACE
 DIAGRAMS AND DIMENSIONS AND LOCATIONS OF THE ACCESSIBLE
 SINKS- LAV SINKS ARE SHOWN- SEE SHEETS A1.1.1, A1.1.2,
 & A1.1.3. SHEET A1.6.9 SHOWS A TYP. SINK AND A BASE
 CABINET W/ SINK DETAIL. PLEASE CLARIFY WHICH DETAIL
 APPLIES TO WHICH OF THE SINKS OF THE SHOWN ON THE
 PLANS. PLEASE NOTE I AM UNABLE TO VIEW REVISED SHEET
 A1.1.2 DUE TO AN ERROR IN THE UPLOADING PROCESS.
  
 12) PASSED. P0.0.2: PROVIDE A PLUMBING DEVICE SCHEDULE
 INDICATING MAKES, MODEL NUMBERS AND LISTINGS FOR WATER
 HAMMER ARRESTORS, MIXING VALVES, BACKFLOW PREVENTERS,
 AND TRAP PRIMERS- SECTIONS 604.9, 607.2.1, 608.3 AND
 1002.4.1.1 FBC P. DEFERRED SUBMITTALS REQUIRED TO BE
 ONSITE FOR INSPECTION- SEE NOTE FOR COMMENT 34.
  
 15) FAILED. P0.0.1, P2.1.1, P4.1.1: INCLUDE THE WASHING
 MACHINE IN THE FIXTURE SCHEDULE AND INDICATE THE
 MACHINE SHALL DISCHARGE THROUGH AN INTERCEPTOR THAT IS
 PROVIDED WITH A WIRE BASKET OR SIMILAR DEVICE,
 REMOVABLE FOR CLEANING, THAT PREVENTS PASSAGE INTO THE
 DRAINAGE SYSTEM OF SOLIDS 1/2 INCH OR LARGER IN SIZE,
 STRING, RAGS, BUTTONS OR OTHER MATERIALS DETRIMENTAL TO
 THE PUBLIC SEWAGE SYSTEM- SECTION 1003.6 FBC P. PROVIDE
 AN EQUIPMENT SCHEDULE ON THE PLAN AND SUBMIT
 MANUFACTURER'S SPECIFICATIONS TO VERIFY COMPLIANCE.
 PLACE A NOTE ON THE PLANS TO INDICATE FOR DOMESTIC
 PURPOSES, NOT FOR COMMERCIAL FACILITY USE.
  
 16) PASSED. P2.1.1, P4.1.1, P4.1.2: SHOW TRAP PRIMER
 CONNECTIONS FOR EMERGENCY FLOOR DRAINS- SECTION
 1004.2.1 FBC P. REVIEWER WILL PROVIDE A REDLINE NOTE ON
 APPROVED PLANS.
  
 23) FAILED. P.2.2.1, P4.1.2: SHOW THE WATER SUPPLY
 PIPING TO THE WASHING MACHINE, DISHWASHER, BEVERAGE
 DISPENSER, AND ICE MAKER- TABLE 604.5 FBC P, AND
 SECTIONS 107.2.1, 107.3.5.1.3 WPB. SHOW THE REQUIRED
 WATER HAMMER ARRESTORS AND BACKFLOW PREVENTERS-
 SECTIONS 604.9 & 608.3 FBC P. WATER SUPPLY TO THE
 WASHING MACHINE, DISHWASHER, BEVERAGE DISPENSER, AND
 ICE MAKER NOT SHOWN.
  
 24) FAILED. P.2.2.1, P.2.2.2, P2.2.3, P4.1.2: SHOW THE
 3/4 IN. FIXTURE SUPPLY PIPES TO THE WATER CLOSETS AND
 URINALS- TABLE 604.5 FBC P. THE ISOMETRIC APPEARS TO
 SHOW 1/2 IN. CW LINES TO WC AND UR IN SOME LOCATIONS.
 FOR CLARIFICATION PLEASE SHOW THE SUPPLY PIPE SIZES OR
 ADD A NOTE.
  
 26) FAILED. P2.2.1, P2.2.2, P2.2.3, P4.1.2, P5.1.1,
 P5.1.2: INDICATE HOW TEMPERED WATER WILL BE PROVIDED TO
 THE LAVATORIES- SECTION 416.5. SHOW MIXING VALVE
 LOCATIONS- SECTION 607.1.2 FBC P. MIXING VALVE
 LOCATIONS NOT SHOWN ON THE RISER. PLEASE SEE DEFINITONS
 OF TEMPERED WATER AND HOT WATER. IT APPEARS THAT
 TEMPERED WATER LINES ARE LABELED AS HW LINES. PLEASE
 CLARIFY HOW HW WILL BE SUPPLIED TO FIXTURES SUCH AS THE
 MOP SINKS AND WASHING MACHINE THAT REQUIRE HOT WATER-
 SECTION 607.1 FBC P.
  
 28) FAILED. P0.0.2, P2.2.1, P4.1.2: BASED ON THE LEGEND
 IT APPEARS THE HOT WATER SYSTEM RETURN PIPE WILL BE A
 1/2 IN. COLD WATER PIPE. IS THE PIPE SHOWN CORRECTLY? -
 SECTION 107.2.1 WPB AND SECTION C404.6.1 FBC EC.THE 1/2
 IN. RETURN LINE TO EWH-1 IS STILL SHOWN AS A CW PIPE
 BASED ON THE LEGEND SYMBOLS ON P0.0.2.
  
 33) FAILED. PLEASE NOTE SEPARATE PERMIT APPLICATIONS
 AND PLANS ARE REQUIRED FOR THE POTABLE WATER SERVICE
 BACKFLOW PREVENTER, BACKFLOW PREVENTER FOR THE CHILLER,
 GREASE INTERCEPTOR, IRRIGATION SYSTEM, FIRE LINE, FIRE
 LINE BACKFLOW PREVENTER, AND FIRE SPRINKLER SYSTEM.
 COMPLETE SETS OF PLANS AND SPECIFICATIONS ARE REQUIRED
 FOR REVIEW AND PERMIT ISSUANCE- SECTION 107.2.1 WPB.
 PROVIDE A LIST OF SEPARATE PERMITS ON THE PLANS
 INCLUDING THE RELOCATION OF BF PREVENTERS SHOWN ON C09.
 A) FAILED. BACKFLOW PREVENTERS: PLEASE NOTE THAT FL.
 LICENSED PLUMBING CONTRACTORS SHALL OBTAIN SEPARATE
 PERMITS FOR INSTALLATION OF THE BACKFLOW PREVENTERS IN
 ACCORDANCE WITH SECTION 105.1 WPB AND SEC. 90-33 WPB
 CODE OF ORDINANCES. THE DEVICES SHALL BE TESTED AND
 CERTIFIED BY THE WPB UTILITIES DEPARTMENT PRIOR TO
 FINAL INSPECTION BY THE BUILDING DEPARTMENT. PLEASE
 CONTACT THE WPB UTILITIES CENTRAL OPERATIONS DEPT.AT
 561-822-2210 FOR FURTHER INFORMATION. SEE COMMENT #33.
 B) FAILED. GREASE INTERCEPTOR: SUBMITTED PLANS SHALL
 INCLUDE GREASE WATER CALCULATIONS IN ACCORDANCE WITH
 SECTION 1003.3.4 FOR HYDROMECHANICAL INTERCEPTORS OR
 1003.3.6 FOR GRAVITY TYPE INTERCEPTORS. MANUFACTURER'S
 SPECIFICATIONS AND INSTALLATION MANUALS SHALL ALSO BE
 SUBMITTED FOR REVIEW. PROVIDE KITCHEN COOKING NOTE- SEE
 COMMENT #3.
  
 34) PASSED. REQUIRED SUBMITTALS: MANUFACTURER'S
 SPECIFICATIONS AND INSTALL MANUALS FOR THE WATER
 HEATERS, WASHING MACHINE, MIXING VALVES, RECIRCULATION
 PUMPS, SUMP PUMP, PIPE INSULATION, KITCHEN EQUIPMENT
 BACKFLOW PREVENTERS- SECTION 107.1 WPB. PLEASE ALL
 SUBMITTALS MAY BE DEFERRED IN ACCORDANCE WITH SECTION
 107.3.4.1 WPB. PROVIDE A LIST OF DEFERRED SUBMITTALS TO
 BE REVIEWED AND APPROVAL BY THE DESIGN PROFESSIONALS OF
 RECORD, AND TO BE ONSITE AT TIME OF INSPECTION.
  
 NEW COMMENTS
  
 1) SHEET A1.6.2 DETAIL 9: PLEASE CLARIFY IF AMBULATORY
 COMPARTMENTS ARE BEING INSTALLED. BASED ON SECTION
 213.3.1 FBC ACC THEY ARE NOT REQUIRED, HOWEVER IF THE
 INTENTION IS TO PROVIDE ONE, PLEASE REVIEW SECTIONS
 605.8.2, 604.8.2.1 & 604.8.2.2 FBC ACC AND CORRECT THE
 ARCHTECTURAL AND PLUMBING FLOOR PLANS. PLEASE PROVIDE
 GRAB BAR DETAILS- SECTION 604.8.2.3 FBC ACC.
  
 2) A.1.8.1: THE ROOM FINISH SCHEDULE APPEARS TO SHOW
 EPOXY PAINTED GYPSUM WALLBOARD MATERIAL AS WALL FINISH
 FOR THE EVS ROOMS WHERE MOP SINKS ARE LOCATED. PLEASE
 NOTE WALLS AND PARTITIONS WITHIN 2 FEET OF SERVICE
 SINKS, URINALS AND WATER CLOSETS SHALL HAVE A SMOOTH,
 HARD, NONABSORBENT SURFACE, TO A HEIGHT OF NOT LESS
 THAN 4 FEET (1219 MM) ABOVE THE FLOOR, AND EXCEPT FOR
 STRUCTURAL ELEMENTS, THE MATERIALS USED IN SUCH WALLS
 SHALL BE OF A TYPE THAT IS NOT ADVERSELY AFFECTED BY
 MOISTURE- SEE SECTION 1210.2.2 FBC B.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2021-01-06 Cont ID  
Sent By ccole Date 2021-01-06 Time 07:59 Rev Time 0.00
Received By ccole Date 2021-01-04 Time 11:51 Sent To  
Notes
2021-01-06 08:00:141ST REVIEW FBC-2017 PLUMBING
 PERMIT- 20120145
 1/4/2021
  
 CODES IN EFFECT:
 FBC P- FLORIDA PLUMBING CODE SIXTH EDITION 2017
 FBC ACC- FLORIDA ACCESSIBILITY CODE SIXTH ADDITION 2017
 FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017
 FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION
 2017
 FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017
 FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION
 2017
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2017
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SHEETS LS1.1 & LS1.2: PLEASE INCLUDE THE REQUIRED
 SERVICE SINKS IN THE PLUMBING FIXTURE CALCULATIONS-
 TABLE 403.1 FBC P.
  
 2) LS1.1 & LS1.2: THE ARCHITECTURAL AND PLUMBING PLANS
 ARE INDICATING A DEFICIENT NUMBER OF MALE AND FEMALE
 WATER CLOSETS- 11 FOR EACH SEX ARE REQUIRED HOWEVER THE
 PLANS ARE DESIGNATING 8 FOR EACH SEX. PLEASE NOTE THAT
 PLUMBING FIXTURES IN FAMILY OR ASSISTED USE TOILET
 ROOMS ARE PERMITTED TO BE INCLUDED IN THE NUMBER OF
 REQUIRED FIXTURES FOR EITHER THE MALE OR FEMALE
 OCCUPANTS ONLY IN ASSEMBLY AND MERCANTILE OCCUPANCIES-
 SEE SECTION 403.1.2 FBC P. THE PLANS AND FIXTURE
 CALCULATIONS SPECIFY MIXED OCCUPANCIES OF BUSINESS AND
 INSTITUTIONAL- 4.
  
 3) A1.6.1 & P DRAWINGS: BASED ON THE SERVING KITCHEN
 PLAN IT APPEARS THAT A GREASE INTERCEPTOR MUST BE
 PROVIDED TO RECEIVE THE DRAINAGE FROM THE HOT FOOD
 WELL, DISHWASHER, FOOD WASTE DISPOSAL, AND ALL DIRECT
 OR INDIRECT WASTE RECEPTORS SERVING KITCHEN APPLIANCES
 AND EQUIPMENT THAT PRODUCE GREASE OR FAT-LADEN WASTE
 EFFLUENTS- SEE SECTION 1003.3.1 FBC P. CONCERNING THE
 FOOD WASTE DISPOSAL REFER TO SECTION 1003.3.2 FBC P AND
 PROVIDE A SOLIDS INTERCEPTOR TO SEPARATE THE DISCHARGE
 BEFORE CONNECTING TO THE INTERCEPTOR.
  
 4) A1.6.1, P0.0.1, & P2.1.1: THE SERVING KITCHEN SHOWS
 AN FD UNDER THE HOT FOOD WELL AND OTHER FLOOR DRAINS
 THAT ARE NOT INCLUDED IN THE FIXTURE SCHEDULE.
 CONCERNING THE FLOOR DRAIN SERVING THE FOOD WELL REFER
 TO SECTIONS 802.1 & 802.3: OTHER THAN HUB DRAINS THAT
 RECEIVE ONLY CLEAR-WATER WASTE AND STANDPIPES, A
 REMOVABLE STRAINER OR BASKET SHALL COVER THE OUTLET OF
 WASTE RECEPTORS. THE DISHWASHER SHALL ALSO DISCHARGE TO
 THE DRAINAGE SYSTEM THROUGH AN INDIRECT WASTE PIPE-
 PLEASE SECTIONS AND 802.3.1, 802.3.2 AND 427.1 FOR
 INDIRECT WASTE RECEPTOR COMPLIANCES. THE PLANS ALSO
 SHOW AN ICE MAKER AND BEVERAGE DISPENSERS IN THE
 KITCHEN WITH NO INDIRECT WASTE RECEPTORS BELOW THEM TO
 RECEIVE CONDENSATE DRAINAGE- SECTION 802.1 FBC P.
 PLEASE NOTE THAT CONDENSATE FROM COOLING COILS SHALL
 NOT DRAIN INTO THE CITY SANITARY SYSTEM- SECTION 90-126
 WPB CODE OF ORDINANCES.
  
 5) SHEETS A1.6.2, A1.6.4, A1.6.5, & A1.6.6: ACCESSIBLE
 WC COMPARTMENT AND STANDARD WC COMPARTMENT DEPTH
 MEASUREMENTS NOT SHOWN- SECTIONS 604.8.1.1 FBC ACC, AND
 SECTION 405.3.1 FBC P.
  
 6) A1.6.2, A1.6.4, A1.6.5, & A1.6.6: THE ADA PLANS
 SUBMITTED ARE STAMPED FOR REFERENCE ONLY PLEASE PROVIDE
 THE FOLLOWING LIST OF FBC ACC COMPLIANCE DETAILS-
 A) CLEAR FLOOR SPACE DIMENSIONS FOR THE WATER CLOSETS-
 SECTION 604.3.
 B) CLEAR FLOOR SPACE DIMENSIONS FOR THE LAVATORIES-
 SECTION 606.2.
 C) CENTERLINES OF THE WATER CLOSETS FROM THE SIDE
 WALLS- SECTION 604.2.
 D) HEIGHTS OF THE WATER CLOSET SEATS FROM THE FINISHED
 FLOORS- SECTION 604.4.
 E) HEIGHTS OF THE MIRRORS FROM THE FINISHED FLOORS TO
 THE REFLECTIVE SURFACES- SECTION 603.3
 F) LOCATIONS, LENGTHS, AND MOUNTING HEIGHTS OF GRAB
 BARS FOR THE WATER CLOSETS- SECTION 604.5 & 609.4
 G) LOCATIONS OF THE WATER CLOSET FLUSH CONTROLS -
 SECTION 604.6.
 H) CENTERLINES OF THE TOILET PAPER DISPENSER MEASURED
 FROM THE FRONTS OF THE WATER CLOSETS- SECTION 604.7.
 I) KNEE AND TOE CLEARANCES FOR THE LAVATORIES- SECTION
 606.2.
 J) CLEAR FLOOR SPACE DIAGRAMS AND DIMENSIONS FOR THE
 ACCESSIBLE URINALS- 605.3
 H) HEIGHTS OF THE ACCESSIBLE URINAL RIMS ABOVE THE
 FINISHED FLOORS- SECTION 605.2.
  
 7) A1.6.4 & A1.6.5: ACCESSIBLE SHOWER, FBC ACC-
 A) CLEAR FLOOR SPACE DIAGRAM AND DIMENSIONS FOR THE
 SHOWER- SECTION 608.2.1
 B) LOCATIONS, LENGTHS, AND MOUNTING HEIGHTS OF GRAB
 BARS- SECTION 608.3 AND 608.3.1
 C) LOCATION OF CONTROL, FAUCET, AND SHOWER SPRAY IN THE
 SHOWER- SECTION 608.5.1.
 D) SHOWER SPRAY UNIT SPECIFICATIONS PER SECTION 608.6.
 E) SHOWER SEAT DIMENSIONS, HEIGHT, CLEARANCES AND
 EXTENSIONS AS OUTLINED IN SECTIONS 610.3 & 610.3.2.
  
 8) DRINKING FOUNTAINS.
 A) LS1.1 & LS1.2: THE FIXTURE CALCULATIONS INDICATE 5
 DRINKING FOUNTAINS ARE REQUIRED HOWEVER THERE APPEARS
 TO BE ONLY 4 SHOWN ON THE PLANS. PLEASE REFER TO TABLE
 403.1, SECTION 410.3 FBC P, AND SECTION 211.1 FBC ACC.
 PLEASE NOTE THAT A BOTTLE FILLING STATION EWC2 DOES NOT
 MEET THE REQUIREMENT, HOWEVER CLEAR FLOOR SPACE AND
 REACH RANGES TO ACCESS THE BOTTLE FILLER ARE REQUIRED-
 PROVIDE DETAILS SHOWING COMPLIANCE-SECTION 904.5.1 FBC
 ACC.
 B) REFER TO SECTIONS 306, 307, AND 602 FBC ACC AND
 PROVIDE DRINKING FOUNTAIN INSTALLATION DETAILS AND
 ELEVATION VIEWS SHOWING KNEE AND TOE CLEARANCES, SPOUT
 HEIGHTS, AND SPOUT LOCATIONS. SHOW THE REQUIRED 30 X 48
 IN. CLEAR FLOOR SPACE FOR A FORWARD WHEELCHAIR APPROACH
 TO THE FOUNTAIN- SECTION 602.2 FBC ACC, AND SHOW HOW
 THE LOCATIONS OF THE FOUNTAINS WILL BE IN COMPLIANCE
 WITH SECTION 307.2 PROTRUSION LIMITS.
  
 9) SINKS- P0.0.1: REFER TO SECTION 212.3 FBC ACC WHICH
 REQUIRES A MINIMUM OF 5%, BUT NO FEWER THAT ONE SINK OF
 EACH TYPE TO BE ACCESSIBLE. THIS WOULD INCLUDE THE L1,
 S1, S2, S3, S4, & S5 IN USE THROUGHOUT THE FACILITY.
 PLEASE DESIGNATE WHICH SINKS WILL BE MADE ACCESSIBLE BY
 SHOWING THE CLEAR FLOOR SPACE DIAGRAM AND DIMENSIONS AT
 EACH LOCATION ON THE ARCHITECTURAL AND PLUMBING
 DRAWINGS- SECTION 606.2. PROVIDE ELEVATION VIEWS FOR
 EACH ACCESSIBLE SINK SHOWING COMPLIANCE WITH SECTIONS
 606.3, 306, 308, 309- HEIGHTS FROM FINISHED FLOORS,
 KNEE AND TOE CLEARANCES, REACH RANGE TO FAUCET
 CONTROLS, AND OPERABLE PARTS.
  
 10) P0.0.1: PROVIDE SHOWER SPRAY SPECIFICATIONS IN THE
 FIXTURE SCHEDULE- SECTION 608.3 FBC ACC AND 424.2 FBC
 P.
  
 11) P0.0.1: WATER DISTRIBUTION AND SANITARY DRAINAGE
 AND VENT PIPING SPECIFICATIONS NOT PROVIDED- SECTIONS
 605.3 605.4, 702.1 & 702.2 FBC P.
  
 12) P0.0.2: PROVIDE A PLUMBING DEVICE SCHEDULE
 INDICATING MAKES, MODEL NUMBERS AND LISTINGS FOR WATER
 HAMMER ARRESTORS, MIXING VALVES, BACKFLOW PREVENTERS,
 AND TRAP PRIMERS- SECTIONS 604.9, 607.2.1, 608.3 AND
 1002.4.1.1 FBC P.
  
 13) P0.0.2 & P2.1.1: PLEASE PROVIDE ENLARGED SP-1
 INSTALLATION AND PLUMBING PIPING DETAILS- SECTIONS
 712.2- 712.3.5 FBC P.
  
 14) P0.0.1, P2.1.1, P2.1.2, P2.1.3: INCLUDE THE FLOOR
 DRAINS (FD, FD-1, FD-3) IN THE FIXTURE SCHEDULE-
 SECTION 412.1 FBC P.
  
 15) P0.0.1, P2.1.1, P4.1.1: INCLUDE THE WASHING MACHINE
 IN THE FIXTURE SCHEDULE AND INDICATE THE MACHINE SHALL
 DISCHARGE THROUGH AN INTERCEPTOR THAT IS PROVIDED WITH
 A WIRE BASKET OR SIMILAR DEVICE, REMOVABLE FOR
 CLEANING, THAT PREVENTS PASSAGE INTO THE DRAINAGE
 SYSTEM OF SOLIDS 1/2 INCH OR LARGER IN SIZE, STRING,
 RAGS, BUTTONS OR OTHER MATERIALS DETRIMENTAL TO THE
 PUBLIC SEWAGE SYSTEM- SECTION 1003.6 FBC P.
  
 16) P2.1.1, P4.1.1, P4.1.2: SHOW TRAP PRIMER
 CONNECTIONS FOR EMERGENCY FLOOR DRAINS- SECTION
 1004.2.1 FBC P.
  
 17) P2.1.1, P4.1.1, C9: SHOW THE BUILDING
 DRAIN/SANITARY SEWER POINT OF CONNECTION JUNCTION AND
 PROVIDE A CLEANOUT AT THE JUNCTION- SECTION 708.1.3 FBC
 P.
  
 18) P2.1.1, P2.1.2, P4.1.3, C9: SHOW BUILDING STORM
 DRAIN CONNECTIONS TO MAIN STORM DRAIN PIPES ON SITE-
 SECTION 107.2.1 WPB, AND CLEANOUT LOCATIONS- SECTION
 1108.1 FBC P.
  
 19) P2.1.2 & P4.1.1: S-3 IN THE CONFERENCE ROOM IS
 MISLABELED AS S-4- SECTION 107.2.1 WPB.
  
 20) P2.1.2: INDICATE THE TERMINATION LOCATION FOR THE
 CONDENSATE PIPING SHOWN EXITING THE BUILDING BY
 CORRIDOR P102- SECTION 314.2.1 FBC P.
  
 21) P0.0.1, P2.1.2: I CANNOT LOCATE THE SS1 HOWEVER
 THERE IS AN S4 COUNTER SINK SHOWN IN THE SOILED ROOM.
 IS THIS SINK MISLABELED? REFER TO SECTIONS 422.6 &
 422.7 FBC P. AND VERIFY A CLINICAL SINK IS NOT REQUIRED
 PER ACHA OR ANOTHER AGENCY.
  
 22) P.2.2.1, P4.1.2, C9: SHOW THE LOCATIONS OF THE
 WATER METER, REQUIRED SHUTOFF VALVE ON DISCHARGE SIDE,
 AND THE MAIN WATER DISTRIBUTION SHUTOFF VALVE AT THE
 BUILDING ENTRANCE- SECTION 606.1 (1,2,3) FBC P.
  
 23) P.2.2.1, P4.1.2: SHOW THE WATER SUPPLY PIPING TO
 THE WASHING MACHINE, DISHWASHER, BEVERAGE DISPENSER,
 AND ICE MAKER- TABLE 604.5 FBC P, AND SECTIONS 107.2.1,
 107.3.5.1.3 WPB. SHOW THE REQUIRED WATER HAMMER
 ARRESTORS AND BACKFLOW PREVENTERS- SECTIONS 604.9 &
 608.3 FBC P.
  
 24) P.2.2.1, P.2.2.2, P2.2.3, P4.1.2: SHOW THE 3/4 IN.
 FIXTURE SUPPLY PIPES TO THE WATER CLOSETS AND URINALS-
 TABLE 604.5 FBC P.
  
 24) P2.2.2, P4.1.2: SHOW THE LOCATIONS OF THE WATER
 LINE FEEDS UP TO THE 2ND FLOOR AND THE REQUIRED SHUTOFF
 VALVES- SECTION 606.1(4) FBC P.
  
 25) P2.2.3, P4.1.2: SHOW THE SHUTOFF VALVE LOCATIONS
 FOR WATER DOWN-FEED PIPES- SECTION 606.(5) FBC P.
  
 26) P2.2.1, P2.2.2, P2.2.3, P4.1.2 FBC P: INDICATE HOW
 TEMPERED WATER WILL BE PROVIDED TO THE LAVATORIES-
 SECTION 416.5. SHOW MIXING VALVE LOCATIONS- SECTION
 607.1.2 FBC P.
  
 27) P4.1.2: PLEASE LABEL THE RECIRCULATION PUMPS AND
 THE WATER HEATERS- SECTIONS 607.1, 607.2.1, FBC P.
  
 28) P0.0.2, P2.2.1, P4.1.2: BASED ON THE LEGEND IT
 APPEARS THE HOT WATER SYSTEM RETURN PIPE WILL BE A 1/2
 IN. COLD WATER PIPE. IS THE PIPE SHOWN CORRECTLY? -
 SECTION 107.2.1 WPB AND SECTION C404.6.1 FBC EC.
  
 29) P2.2.1: PLEASE NOTE THE BACKFLOW PREVENTER PROVIDED
 FOR THE CHILLED WATER SUPPLY SHALL BE UNDER A SEPARATE
 PERMIT. PLEASE PROVIDE A NOTE ON THE PLAN TO CLARIFY-
 SECTION 107.2.1 WPB.
  
 30) REFER TO TABLE C403.2.10 FBC EC AND INDICATE THE
 TYPE AND THICKNESS OF THE HOT WATER PIPE INSULATION AND
 PROVIDE A PRODUCT SUBMITTAL.
  
 31) P5.1.1: PROVIDE A DRAIN PAN AND DRAIN PAN LINE FOR
 THE WATER HEATER SHOWN IN THE DETAIL- REFER TO SECTIONS
 504.7, 504.7.1 FBC P. SHOW THE TERMINATION LOCATION OF
 THE LINE- SECTION 504.7.2.
  
 32) ROOF DRAINAGE- SHEETS P2.2.4, P2.2.5, A1.30,
 A1.3.1, A1.3.2:
 A) VERIFY THE ROOF AND DRAINAGE SYSTEM HAS BEEN
 DESIGNED IN COMPLIANCE WITH SECTION 1101.7 FBC P FOR
 MAXIMUM DEPTH OF PONDING WATER AND DEFLECTED STRUCTURAL
 ELEMENTS.
 B) INDICATE THE RAINFALL RATE (INCHES PER HOUR) BASED
 ON SECTION 1106.1.
 C) PROVIDE ROOF DRAINAGE AREA CALCULATIONS INCLUDING
 FLAT ROOFS, PARAPETS, AND SLOPE ROOFS DRAINING ONTO
 FLAT ROOFS. CONVERT SQUARE FT. CALCULATIONS TO GPM AND
 PROVIDE SIZING CALCULATIONS FOR PRIMARY VERTICAL AND
 HORIZONTAL DRAINS- TABLE 1106.2, AND VERTICAL LEADERS-
 TABLE 1106.3. PLEASE INCLUDE THE SLOPES OF THE
 HORIZONTAL DRAINS BASED ON TABLE 1106.2.
 D) REFER TO SECTION 1108.3 AND PROVIDE OVERFLOW DRAIN
 CALCULATIONS BASED ON SECTION 1106.
 E) SHOW THE SIZES OF THE SLOPED ROOF HORIZONTAL GUTTERS
 AND DOWNSPOUTS AND PROVIDE SIZING CALCULATIONS FOR
 EACH- SECTION AND TABLE 1106.6
 F) PROVIDE GUTTER AND DOWNSPOUT ATTACHMENT DETAILS-
 SECTION 1101.6.
 G) SHOW HOW THE GUTTER DOWNSPOUTS WILL EITHER CONNECT
 TO THE STORM DRAIN PIPE SYSTEM OR BE DRAINED TO AN
 APPROVED PLACE OF DISPOSAL- SECTION 1101.2.
  
 33) PLEASE NOTE SEPARATE PERMIT APPLICATIONS AND PLANS
 ARE REQUIRED FOR THE POTABLE WATER SERVICE BACKFLOW
 PREVENTER, BACKFLOW PREVENTER FOR THE CHILLER, GREASE
 INTERCEPTOR, IRRIGATION SYSTEM, FIRE LINE, FIRE LINE
 BACKFLOW PREVENTER, AND FIRE SPRINKLER SYSTEM. COMPLETE
 SETS OF PLANS AND SPECIFICATIONS ARE REQUIRED FOR
 REVIEW AND PERMIT ISSUANCE- SECTION 107.2.1 WPB.
  
 A) BACKFLOW PREVENTERS: PLEASE NOTE THAT FL. LICENSED
 PLUMBING CONTRACTORS SHALL OBTAIN SEPARATE PERMITS FOR
 INSTALLATION OF THE BACKFLOW PREVENTERS IN ACCORDANCE
 WITH SECTION 105.1 WPB AND SEC. 90-33 WPB CODE OF
 ORDINANCES. THE DEVICES SHALL BE TESTED AND CERTIFIED
 BY THE WPB UTILITIES DEPARTMENT PRIOR TO FINAL
 INSPECTION BY THE BUILDING DEPARTMENT. PLEASE CONTACT
 THE WPB UTILITIES CENTRAL OPERATIONS DEPT.AT
 561-822-2210 FOR FURTHER INFORMATION.
  
 B) GREASE INTERCEPTOR: SUBMITTED PLANS SHALL INCLUDE
 GREASE WATER CALCULATIONS IN ACCORDANCE WITH SECTION
 1003.3.4 FOR HYDROMECHANICAL INTERCEPTORS OR 1003.3.6
 FOR GRAVITY TYPE INTERCEPTORS. MANUFACTURER'S
 SPECIFICATIONS AND INSTALLATION MANUALS SHALL ALSO BE
 SUBMITTED FOR REVIEW.
  
 34) REQUIRED SUBMITTALS: MANUFACTURER'S SPECIFCATIONS
 AND INSTALL MANUALS FOR THE WATER HEATERS, WASHING
 MACHINE, MIXING VALVES, RECIRCULATION PUMPS, SUMP PUMP,
 PIPE INSULATION, KITCHEN EQUIPMENT BACKFLOW PREVENTERS-
 SECTION 107.1 WPB. PLEASE ALL SUBMITTALS MAY BE
 DEFERRED IN ACCORDANCE WITH SECTION 107.3.4.1 WPB.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  
  
  
  
  
  

Review Stop P-GREASE GREASE INTERCEPTOR/TRAP REVIEW
Rev No 1 Status P Date 2021-06-08 Cont ID  
Sent By ccole Date 2021-06-07 Time 17:33 Rev Time 0.00
Received By ccole Date 2021-06-07 Time 17:33 Sent To  
Notes
2021-06-07 17:33:55SEPARATE PERMIT APPLICATION MUST BE SUBMITTED FOR
 INSTALLATION.

Review Stop P-IRRIGATE IRRIGATION REVIEW
Rev No 1 Status N Date 2021-06-08 Cont ID  
Sent By ccole Date 2021-06-08 Time 07:15 Rev Time 0.00
Received By ccole Date 2021-06-07 Time 17:34 Sent To  
Notes
2021-06-08 07:15:57SEPARATE PERMIT AND PLANS REQUIRED.
  

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status P Date 2021-02-26 Cont ID  
Sent By rmcphers Date 2021-02-26 Time 13:14 Rev Time 0.00
Received By rmcphers Date 2021-02-26 Time 13:13 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2021-01-04 Cont ID  
Sent By rmcphers Date 2021-01-04 Time 14:08 Rev Time 0.00
Received By rmcphers Date 2021-01-04 Time 14:08 Sent To  
Notes
2021-01-04 14:08:41SEE BUILDING PLAN REVIEW

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 4 Status P Date 2021-06-07 Cont ID  
Sent By ccole Date 2021-06-07 Time 17:32 Rev Time 0.00
Received By ccole Date 2021-06-07 Time 16:53 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status P Date 2021-04-08 Cont ID  
Sent By rmcphers Date 2021-04-08 Time 13:17 Rev Time 0.00
Received By rmcphers Date 2021-04-08 Time 13:17 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status F Date 2021-02-11 Cont ID  
Sent By medwards Date 2021-02-11 Time 07:43 Rev Time 0.00
Received By medwards Date 2021-02-11 Time 07:17 Sent To  
Notes
2021-02-11 07:45:06SEVERAL SHEETS FAILED TO UPLOAD CORRECTLY. THESE WILL
 NEED TO BE REVIEWED WHEN CORRECTLY UPLOADED.
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2020-12-23 Cont ID  
Sent By medwards Date 2020-12-23 Time 15:04 Rev Time 0.00
Received By medwards Date 2020-12-23 Time 15:03 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 4 Status P Date 2021-05-27 Cont ID  
Sent By eschneid Date 2021-05-27 Time 14:42 Rev Time 0.75
Received By eschneid Date 2021-05-27 Time 14:03 Sent To  
Notes
2021-05-27 14:42:231) SEPARATE PERMITS WITH PLANS ARE REQUIRED FOR THE
 FOLLOWING:
  
 A. SITE LIGHTING
 B. BICYCLE RACKS
 C. HARDSCAPE
 D. PARKING LOT STRIPING
 E. PERIMETER WALLS AND FENCES
  
 2) PRIOR TO THE FIRST CERTIFICATE OF OCCUPANCY FOR THE
 NEW PACE OR HOSPICE CARE BUILDINGS (WHICHEVER OCCURS
 FIRST), MORSELIFE MUST INSTALL A BUS SHELTER, AT
 MORSELIFE?S EXPENSE, AT THE PALM TRAN BUS STOP AT
 HAVERHILL ROAD AND LORING DRIVE, ADJACENT TO THE
 MORSELIFE CSPD ENTRANCE. THE BUS SHELTER DESIGN SHALL
 BE COORDINATED WITH PALM TRAN. MORSELIFE SHALL PROVIDE
 ANY REQUIRED EASEMENTS FOR THE BUS SHELTER.
  
  
  

Review Stop Z ZONING
Rev No 3 Status F Date 2021-04-29 Cont ID  
Sent By eschneid Date 2021-04-29 Time 08:31 Rev Time 1.00
Received By eschneid Date 2021-04-28 Time 09:34 Sent To  
Notes
2021-04-29 08:31:03FAILED
  
 PROVIDE WRITTEN RESPONSE TO COMMENTS.
  
 1) THANK YOU FOR PROVIDING THE GRAPHIC SHOWING HOW THE
 SIDEWALK CONNECTION TO THE PUBLIC RIGHT-OF-WAY WILL BE
 PROVIDED TO THE THREE BUILDINGS THAT WILL REMAIN ON THE
 SITE BOTH DURING CONSTRUCTION AND PRIOR TO THE START OF
 CONSTRUCTION OF PHASE II. ZONING REVIEWED YOUR PROPOSED
 PLAN WITH ROBERT BROWN, CHIEF BUILDING OFFICIAL, AND IT
 IS NOT APPROVED AS SHOWN. YOU MUST CLEARLY SHOW HOW A
 PEDESTRIAN, INCLUDING ONE COVERED BY THE ADA, CAN
 SAFELY TRAVERSE FROM THE EXISTING SIDEWALK ON THE
 MORSELIFE SIDE OF THE SITE TO THE EXISTING SIDEWALK
 SERVING THE HOMESAFE BUILDINGS. THE ARROWS THAT ARE
 SHOWN ON THE PLAN FORCE THE PEDESTRIAN TO SHARE DRIVE
 LANES WITH VEHICLES, WHICH IS NOT PERMITTED. THE
 PEDESTRIAN MUST BE ABLE TO USE A SIDEWALK OR HAVE A
 PATH THAT IS SEPARATED FROM THE VEHICULAR TRAVEL LANES.
 NOTE: THE MINIMUM TRAVEL LANE WIDTH IS 20 FEET FOR FIRE
 DEPARTMENT ACCESS, SO THE PROPOSED 20 FOOT WIDE
 CONNECTION CANNOT BE NARROWED. THE PEDESTRIAN ROUTE
 MUST BE IN PLACE PRIOR TO THE FENCING OF THE
 CONSTRUCTION SITE.
  
 2) EVEN THOUGH A SEPARATE SITE LIGHTING PERMIT, WITH
 PLANS, IS REQUIRED, ZONING NOTED THAT THE ELECTRICAL
 REVIEWER HAD ADDED A PASS STAMP TO SHEET E 0-1-1 THE
 ELECTRICAL SITE PLAN AND THUS REVIEWED THE PLAN. ZONING
 WILL NOT APPROVE THE PROPOSED PLAN.
  
 A. THE UNDERGROUND DUCT BANK LINES (HIGHLIGHTED BY THE
 GREEN BOXES ON THE ELECTRONIC VERSION OF THE PLAN) MUST
 BE MOVED OUT OF THE LANDSCAPE AREAS AS THEY DIRECTLY
 CONFLICT WITH APPROVED TREE LOCATIONS. THEY CAN BE RUN
 UNDER THE PAVEMENT.
  
 B. THE DUCT BANKS ARE SHOWN COVERED BY COMPACTED EARTH,
 WHICH IS NOT PERMITTED IN THE LANDSCAPE AREAS. THE TREE
 ROOTS WILL NOT PROPERLY GROW IN COMPACTED EARTH.
 ADDITIONALLY, THE TREES NEED A FULL THREE FEET OF COVER
 FOR PROPER ROOT GROWTH, WHICH DOES NOT OCCUR DUE TO THE
 INSTALLATION OF THE MYLAR WARNING TAPE AT TWO FEET IN
 DEPTH.
  
 3) SEPARATE PERMITS WITH PLANS ARE REQUIRED FOR THE
 FOLLOWING:
  
 A. SITE LIGHTING
 B. BICYCLE RACKS
 C. HARDSCAPE
 D. PARKING LOT STRIPING
 E. PERIMETER WALLS AND FENCES
  
 CONTACT ERIC SCHNEIDER @ (561) 822-1446
 [email protected]
  

Review Stop Z ZONING
Rev No 2 Status F Date 2021-02-09 Cont ID  
Sent By escneid Date 2021-02-09 Time 16:24 Rev Time 1.50
Received By eschneid Date 2021-02-09 Time 14:08 Sent To  
Notes
2021-02-09 16:25:21FAILED
  
 PROVIDE WRITTEN RESPONSE TO COMMENTS.
  
 1) PROVIDE A GRAPHIC SHOWING HOW THE SIDEWALK
 CONNECTION TO THE PUBLIC RIGHT-OF-WAY WILL BE PROVIDED
 TO THE THREE BUILDINGS THAT WILL REMAIN ON THE SITE
 BOTH DURING CONSTRUCTION AND PRIOR TO THE START OF
 CONSTRUCTION OF PHASE II.
  
 2) REPEAT COMMENT: PRIOR TO ZONING APPROVAL OF THIS
 PERMIT, YOU NEED TO SUBMIT A TREE ALTERATION PERMIT TO
 THE PLANNING DIVISION AND HAVE IT APPROVED. *** WHILE
 THE LANDSCAPE PERMIT HAS BEEN SUBMITTED, NO TREE
 ALTERATION PERMIT HAS BEEN SUBMITTED.
  
 3) SEPARATE PERMITS WITH PLANS ARE REQUIRED FOR THE
 FOLLOWING:
  
 A. SITE LIGHTING
 B. BICYCLE RACKS
 C. HARDSCAPE
 D. PARKING LOT STRIPING
 E. PERIMETER WALLS AND FENCES
  
 CONTACT ERIC SCHNEIDER @ (561) 822-1446
 [email protected]
  

Review Stop Z ZONING
Rev No 1 Status F Date 2021-01-20 Cont ID  
Sent By eschneid Date 2021-01-20 Time 15:04 Rev Time 4.00
Received By eschneid Date 2021-01-20 Time 15:04 Sent To  
Notes
2021-01-20 15:15:15FAILED
  
 PROVIDE WRITTEN RESPONSE TO COMMENTS.
  
 1) PROVIDE A SURVEY FOR THE SITE.
  
 2) PRIOR TO ZONING APPROVAL OF THIS PERMIT, YOU NEED TO
 SUBMIT A DEMOLITION PERMIT FOR THE TWO BUILDINGS SLATED
 FOR REMOVAL.
  
 3) PRIOR TO ZONING APPROVAL OF THIS PERMIT, YOU NEED TO
 SUBMIT A TREE ALTERATION PERMIT TO THE PLANNING
 DIVISION AND HAVE IT APPROVED.
  
 4) THE MECHANICAL EQUIPMENT IN THE EQUIPMENT YARD NEEDS
 TO BE SCREENED TO THE FULL HEIGHT OF THE EQUIPMENT.
 PROVIDE THE FULL HEIGHT OF THE TALLEST PROPOSED ITEMS
 AND PROVIDE VERIFICATION THAT IT IS SCREENED. FROM THE
 INFORMATION PROVIDED, THE WALLS APPEAR TO HAVE ADEQUATE
 HEIGHT TO PROVIDE SCREENING, HOWEVER, THE GATES ARE
 SHORTER AND THUS DO NOT PROVIDE SCREENING.
  
 5) SEPARATE PERMITS ARE REQUIRED FOR THE FOLLOWING AND
 ZONING :
  
 A. SITE LIGHTING
 B. LANDSCAPE
 C. IRRIGATION
 D. BICYCLE RACKS
 E. HARDSCAPE
 F. PARKING LOT STRIPING
  
 CONTACT ERIC SCHNEIDER @ (561) 822-1446
 [email protected]
  


Account Summary | Usage Policy | Privacy Policy