| Plan Review Stops For Permit 20120108 |
| Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
| Rev No |
2 |
Status |
P |
Date |
2021-02-17 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-02-17 |
Time |
10:47 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-02-17 |
Time |
10:47 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
| Rev No |
1 |
Status |
F |
Date |
2021-01-04 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-01-04 |
Time |
08:31 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-01-04 |
Time |
08:31 |
Sent To |
|
|
| Notes |
| 2021-01-04 08:32:28 | PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE | | | CONTRACTOR, ON LETTERHEAD, STATING THAT THE | | | INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM | | | COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH | | | COUNTY WILL BE FOLLOWED, AND THAT NOTIFICATION WILL BE | | | GIVEN TIMELY. ADDITIONAL INFORMATION REGARDING ASBESTOS | | | REQUIREMENTS CAN BE FOUND ON THEIR WEBSITE: | | | | | | HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE | | | S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION- | | | RENOVATION.HTML | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2021-02-17 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-02-17 |
Time |
10:45 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-02-17 |
Time |
10:45 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2021-01-04 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-01-04 |
Time |
08:31 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2020-12-31 |
Time |
14:20 |
Sent To |
|
|
| Notes |
| 2021-01-04 08:31:22 | OFFICE ALTERATION | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected] | | | CODE USED FOR REVIEW - 2017 FBC WITH WPB CHAPTER 1 | | | AMENDMENTS | | | | | | CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107 | | | 1) DOORS MARKED 413, 414, 409, 420, 401A NEED TO SHOW | | | THE REQUIRED FIRE RATING ON THE DOOR SCHEDULE - FBC | | | 716.5 | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2021-02-08 |
|
|
Cont ID |
|
| Sent By |
equinone |
Date |
2021-02-08 |
Time |
09:15 |
Rev Time |
0.00 |
| Received By |
equinone |
Date |
2021-02-08 |
Time |
09:15 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2021-01-06 |
|
|
Cont ID |
|
| Sent By |
equinone |
Date |
2021-01-06 |
Time |
15:27 |
Rev Time |
0.00 |
| Received By |
equinone |
Date |
2021-01-06 |
Time |
09:50 |
Sent To |
|
|
| Notes |
| 2021-01-06 15:28:10 | CODES IN EFFECT | | | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | FAC = FLORIDA ADMINISTRATIVE CODE | | | | | | REVIEW STATUS: FAILED. | | | | | | 1) VAV-1, 5, 6, AND 7 SPECS (M6.1) SHOWS 5KW HEATERS AT | | | 277 VOLTS. PANEL SCHEDULE H4B SPECIFIES CIRCUITS TO BE | | | 20 AMPS BREAKER WITH #12 CONDUCTOR. FIXED ELECTRIC | | | HEATING IS CONTINUOUS AND THE MINIMUM AMPACITY SHOULD | | | BE 125% OF TOTAL LOAD. IT APPEARS THAT THE #12 WIRE | | | WITH 20 AMPS BREAKER ARE UNDERSIZED. PLEASE PROVIDE | | | SPECS FROM MANUFACTURER FOR OVERCURRENT PROTECTION AND | | | WIRE SIZE FOR VAV UNITS AND CONFIRM WHAT THE RIGHT | | | SIZES ARE. NEC 424.3, NEC 240.4 | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. | | | | | | SINCERELY, | | | | | | ENRIQUE QUINONEZ | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2020-12-09 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2020-12-09 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2020-12-09 |
Time |
13:44 |
Sent To |
|
|
| Notes |
| 2020-12-09 13:44:24 | FIRE PROVISO: | | | | | | 1) CARD READER/ACCESS CONTROL SHALL BE INSTALLED UNDER | | | SEPARATE PERMIT, SHOP DRAWINGS AND EQUIPMENT SPEC | | | SHEETS | | | | | | | | | | | | 2) FIRE ALARM SHALL BE INSTALLED UNDER SEPARATE PERMIT, | | | SHOP DRAWINGS AND EQUIPMENT SPEC SHEETS | | | | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2021-03-08 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-03-08 |
Time |
10:47 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-02-18 |
Time |
11:53 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2021-02-17 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-02-17 |
Time |
10:47 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-01-19 |
Time |
22:14 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2021-01-13 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2021-01-13 |
Time |
13:39 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2020-12-04 |
Time |
09:49 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2021-03-08 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-03-08 |
Time |
10:43 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-03-08 |
Time |
10:43 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2021-02-03 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-02-03 |
Time |
06:49 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-02-02 |
Time |
17:39 |
Sent To |
|
|
| Notes |
| 2021-02-03 06:49:23 | 2ND REVIEW FBC-2020 MECHANICAL | | | PERMIT-20120108 | | | | | | CODES IN EFFECT: | | | | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2020 | | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2020 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | | 2020 | | | FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2020 | | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | | 2020 | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH | | | EDITION 2020 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | | EDITION 2020 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) PLEASE PROVIDE CALCULATION FOR THE OUTDOOR AIR BASED | | | ON SECTION 403.3.1.1 AND TABLE 403.3.1.1. YOU MUST THE | | | TABLE AND NOT USE THE ARCHITECTURAL COUNT. SEE EXAMPLE | | | BELOW: | | | CONFERENCE ROOM: 425/1000 = .425,.425 X 50 = 21.25 X 5 | | | = 106.25; 425 X .06 = 25.5; 106.25 + 25.5 = 132 CFM. | | | REMAINING OFFICES: 5237/1000 = 5.237 X 5 = 26.185 X 5 = | | | 130.925; 5237 X .06 = 314.22; 130.925 + 314.22 = 446 | | | CFM | | | WAR ROOM: 290/1000 = .29; .29 X 50 = 14.5 X 5 = 72.5; | | | 290 X .06 = 17.4; 72.5 + 17.4 = 90 CFM. FBC M 403.3.1.1 | | | | | | 2) I DO NOT SEE A REVISED M2.1 SHEET. PLEASE MAKE SURE | | | THE REVISED DRAWING HAS BEEN SUBMITTED. FBC 107.2.1 | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE OLD | | | SHEETS FROM THE PLAN SETS, BIND THEM TOGETHER | | | SEPARATELY AND MARK VOID OR OLD ON THEM. PLEASE RETAIN | | | THEM FOR REFERENCE WITH THE NEW SUBMITTED PLANS. THIS | | | PROCESS WILL ALSO APPLY TO ANY DOCUMENTS SUCH AS | | | PRODUCT APPROVALS OR CALCULATIONS BEING REPLACED OR | | | UPDATED. | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2020-12-19 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2020-12-19 |
Time |
07:40 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2020-12-19 |
Time |
07:40 |
Sent To |
|
|
| Notes |
| 2020-12-19 07:40:36 | 1ST REVIEW FBC-2017 MECHANICAL | | | PERMIT-20120108 | | | | | | CODES IN EFFECT: | | | | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | | 2017 | | | FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017 | | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | | 2017 | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH | | | EDITION 2017 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | | EDITION 2017 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) SHEET M0.1: THERE ARE TWO CONFERENCE ROOMS IN THIS | | | TENANT SPACE, PLEASE PROVIDE OUTDOOR AIR CALCULATIONS | | | FOR THESE TWO CONFERENCE ROOMS BASED ON TABLE | | | 403.3.1.1. FBC M TABLE 403.3.1.1 | | | | | | 2) SHEET M2.1: THE LOCKER ROOM EXHAUST DUCT IS | | | PENETRATING THE WALL SEPARATING THE MEN?S BATHROOM FROM | | | THE WAR ROOM, IT APPEARS THIS WALL SHOULD BE RATED. | | | PLEASE SHOW ITS RATING AND HOW YOU WILL PROTECT THIS | | | WALL AT THE EXHAUST DUCT PENETRATION. FBC M 607 | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE OLD | | | SHEETS FROM THE PLAN SETS, BIND THEM TOGETHER | | | SEPARATELY AND MARK VOID OR OLD ON THEM. PLEASE RETAIN | | | THEM FOR REFERENCE WITH THE NEW SUBMITTED PLANS. THIS | | | PROCESS WILL ALSO APPLY TO ANY DOCUMENTS SUCH AS | | | PRODUCT APPROVALS OR CALCULATIONS BEING REPLACED OR | | | UPDATED. | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2021-01-13 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2021-01-07 |
Time |
12:20 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2021-01-05 |
Time |
13:37 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2021-03-08 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-03-08 |
Time |
10:46 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-03-08 |
Time |
10:46 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2020-12-19 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2020-12-19 |
Time |
08:05 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2020-12-19 |
Time |
08:05 |
Sent To |
|
|
| Notes |
|
|