Plan Review Details - Permit 20120093
| Plan Review Stops For Permit 20120093 |
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
P |
Date |
2020-12-20 |
|
|
Cont ID |
|
| Sent By |
rrossano |
Date |
2020-12-20 |
Time |
|
Rev Time |
|
| Received By |
rrossano |
Date |
2020-12-20 |
Time |
|
Sent To |
|
|
| Notes |
| 2020-12-20 09:27:37 | PASSED WITH PROVISO: | | | 1) MAINTAIN 3 FT. SETBACK FROM PROPOSED DRIVEWAY TO | | | ADJACENT PROPERTY LINE. | | | 2) ADRESS ANY ZONING COMMENTS. | | | 3) CALL FOR LOCATES, DIAL 811 BEFORE YOU DIG. FOR MORE | | | INFO ON "CALL BEFORE YOU DIG", GO TO | | | HTTP://WWW.SUNSHINE811.COM (REF: UNDERGROUND FACILITY | | | DAMAGE PREVENTION AND SAFETY ACT, FLORIDA STATUTE, | | | CHAPTER 556.) | | | | | | THANKS, | | | RICK ROSSANO, PROJECT COORDINATOR, ENGINEERING SERVICES | | | DEPARTMENT | | | 401 CLEMATIS STREET, 4TH FLOOR, WEST PALM BEACH, FL | | | 33401 | | | DIRECT: (561) 494-1098, FAX: (561) 494-1116, MOBILE: | | | (561) 246-9525 | | | EMAIL: [email protected] | | | WWW.WPB.ORG/ENGINEERING | | | |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
P |
Date |
2020-12-28 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2020-12-28 |
Time |
16:15 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2020-12-28 |
Time |
16:15 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2021-03-05 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2021-03-05 |
Time |
11:09 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2021-02-17 |
Time |
06:19 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2021-02-13 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2021-02-13 |
Time |
08:50 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2021-01-28 |
Time |
12:25 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2020-12-28 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2020-12-28 |
Time |
16:15 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2020-12-12 |
Time |
10:15 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2021-03-05 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2021-03-05 |
Time |
09:43 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2021-03-05 |
Time |
09:43 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2021-02-12 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2021-02-12 |
Time |
|
Rev Time |
0.00 |
| Received By |
llouie |
Date |
2021-02-12 |
Time |
|
Sent To |
|
|
| Notes |
| 2021-02-12 16:31:48 | ** FAILED ** | | | | | | PLEASE ADDRESS THE FOLLOWING COMMENTS. RESPOND TO THE | | | COMMENTS IN WRITING AND/OR ON THE PLANS WHERE | | | APPLICABLE: | | | | | | 1.) SHOW THE LOCATION OF A GATE/FENCE IN A SITE | | | PLAN/SURVEY. | | | | | | 2.) SHOW THE LOCATION OF THE NEW PAVERED AREA IN A SITE | | | PLAN/SURVEY. PROVIDE SETBACK DIMENSIONS FROM THE | | | PROPERTY LINE(S) AND LENGTH AND WIDTH OF THE PROPOSED | | | PAVERED AREA. PAVERED AREA SHALL BE CONSISTENT WITH THE | | | SETBACK REQUIREMENTS IN ZLDR S.94-482. | | | | | | 3.) PLEASE CLARIFY IF THE PAVERED AREA IS TO BE | | | UTILIZED FOR PARKING. IF SO, THE PAVERED AREA CANNOT | | | EXCEED 20 FT. IN WIDTH AT THE PROPERTY LINE. [ZLDR | | | S.94-305] | | | | | | 4.) AT LEAST 1,000 SQUARE FEET OR 75% (WHICHEVER IS | | | LESS) OF THE REQUIRED FRONT YARD SHALL REMAIN | | | LANDSCAPED. PLEASE PROVIDE FRONT YARD LANDSCAPING | | | CALCULATIONS TO DEMONSTRATE COMPLIANCE. [ZLDR S.94-482] | | | | | | | | | NOTES: | | | | | | * ANY REVISIONS MAY RESULT IN ADDITIONAL COMMENTS. | | | | | | * CONTACT LINDA LOUIE @ (561) 822-1458 IF THERE ARE | | | QUESTIONS. | | | | | | * ZONE: SF14-C3 | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2020-12-28 |
|
|
Cont ID |
|
| Sent By |
kalexand |
Date |
2020-12-28 |
Time |
16:15 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2020-12-28 |
Time |
16:15 |
Sent To |
|
|
| Notes |
| 2020-12-28 16:17:23 | FENCE/GATE IN FRONT YARD SHALL BE 4' TALL MAXIMUM. NEW | | | PAVED AREA NOT DRAWN. NEED TO CONFIRM 1,000SF OF | | | GREENSPACE REMAINS OR 75% OF FRONT YARD. |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |