| Plan Review Stops For Permit 20120024 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2021-03-29 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-03-29 |
Time |
13:52 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-03-29 |
Time |
13:52 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2021-03-22 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-03-22 |
Time |
08:21 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-03-22 |
Time |
08:15 |
Sent To |
|
|
| Notes |
| 2021-03-22 08:20:57 | SFR ADDITION | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected] | | | CODE USED FOR REVIEW - 2017 FBC WITH WPB CHAPTER 1 | | | AMENDMENTS | | | | | | CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107 | | | 1) PRODUCT APPROVAL INSTALLATION DRAWINGS (FL14285) FOR | | | THE NON IMPACT FRENCH DOORS REQUIRES SHUTTERS - PLEASE | | | PROVIDE THE COMPLETE PRODUCT APPROVAL FOR THE REQUIRED | | | SHUTTERS. FBC R301.2.1.2 | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2021-03-04 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-03-04 |
Time |
12:11 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-03-04 |
Time |
12:11 |
Sent To |
|
|
| Notes |
| 2021-03-04 12:15:55 | SFR ADDITION | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected] | | | CODE USED FOR REVIEW - 2017 FBC WITH WPB CHAPTER 1 | | | AMENDMENTS | | | | | | CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107 | | | 1) PLEASE PROVIDE COMPLETE PRODUCT APPROVALS - FRONT | | | PAGES AND THE INSTALLATION INSTRUCTIONS - FOR THE | | | ANDERSON CASEMENT, FIXED WINDOWS AND FRENCH DOORS ALSO | | | FOR THE PLASTPRO SWING DOOR. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2021-01-06 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-01-06 |
Time |
12:24 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-01-06 |
Time |
08:49 |
Sent To |
|
|
| Notes |
| 2021-01-06 12:24:05 | SFR ADDITION | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected] | | | CODE USED FOR REVIEW - 2017 FBC WITH WPB CHAPTER 1 | | | AMENDMENTS | | | | | | CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107 | | | 1) ALL PRODUCT APPROVALS NEED TO BE REVIEWED AND MARKED | | | APPROVED BY THE BUILDING DESIGNER OF RECORD OR THE | | | PRODUCT APPROVAL NUMBERS CAN BE LISTED ON THE DRAWINGS. | | | FBC WPB 107.3.4 | | | 2) PLEASE PROVIDE THE FRONT PAGES OF THE "FLORIDA | | | STATE" PRODUCT APPROVALS.(ONLY THE INSTALLATION | | | DRAWINGS HAVE BEEN PROVIDED). | | | 3) THERE ARE PRODUCT APPROVALS FOR SINGLE HUNG AND | | | DOUBLE HUNG WINDOWS IN PROJECTDOX - PLEASE SHOW THE | | | LOCATION OF THESE WINDOWS ON THE FLOOR PLANS. | | | 4) THE DETACHED GARAGE ALTERATIONS SHALL BE ON A | | | SEPARATE PERMIT NUMBER - PLEASE ACKNOWLEDGE. | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2021-03-10 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-03-10 |
Time |
14:44 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-03-10 |
Time |
11:24 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2020-12-29 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2020-12-29 |
Time |
16:10 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2020-12-29 |
Time |
14:55 |
Sent To |
|
|
| Notes |
| 2020-12-29 16:17:10 | PLAN REVIEW / ELECTRICAL | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | PLANS EXAMINER BUILDING - PX3169 | | | PLANS EXAMINER 1&2 FAMILY - SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | CODES IN EFFECT: | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | 2014 NEC | | | | | | 1ST REVIEW | | | | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. INDICATE AIC RATING OF SERVICE EQUIPMENT. | | | E3404.2INTERRUPTING RATING. | | | EQUIPMENT INTENDED TO INTERRUPT CURRENT AT FAULT LEVELS | | | SHALL HAVE A MINIMUM INTERRUPTING RATING OF 10,000 | | | AMPERES. EQUIPMENT INTENDED TO INTERRUPT CURRENT AT | | | LEVELS OTHER THAN FAULT LEVELS SHALL HAVE AN | | | INTERRUPTING RATING AT NOMINAL CIRCUIT VOLTAGE OF NOT | | | LESS THAN THE CURRENT THAT MUST BE INTERRUPTED. (110.9) | | | | | | 2. PROVIDE MAIN DISCONNECT. | | | E3601.6.2SERVICE DISCONNECT LOCATION. | | | THE SERVICE DISCONNECTING MEANS SHALL BE INSTALLED AT A | | | READILY ACCESSIBLE LOCATION EITHER OUTSIDE OF A | | | BUILDING OR INSIDE NEAREST THE POINT OF ENTRANCE OF THE | | | SERVICE CONDUCTORS. SERVICE DISCONNECTING MEANS SHALL | | | NOT BE INSTALLED IN BATHROOMS. EACH OCCUPANT SHALL HAVE | | | ACCESS TO THE DISCONNECT SERVING THE DWELLING UNIT IN | | | WHICH THEY RESIDE. [230.70(A)(1), 230.72(C)] | | | | | | 3. SMOKE ALARMS. | | | 1104.1SMOKE ALARMS IN EXISTING PORTIONS OF A BUILDING. | | | R314.2.2ALTERATIONS, REPAIRS AND ADDITIONS. | | | WHERE ALTERATIONS, REPAIRS OR ADDITIONS REQUIRING A | | | PERMIT OCCUR, OR WHERE ONE OR MORE SLEEPING ROOMS ARE | | | ADDED OR CREATED IN EXISTING DWELLINGS, THE INDIVIDUAL | | | DWELLING UNIT SHALL BE EQUIPPED WITH SMOKE ALARMS | | | LOCATED AS REQUIRED FOR NEW DWELLINGS. | | | | | | R314.3 LOCATION. | | | SMOKE ALARMS SHALL BE INSTALLED IN THE FOLLOWING | | | LOCATIONS: | | | 1. 1.IN EACH SLEEPING ROOM. | | | 2. 2.OUTSIDE EACH SEPARATE SLEEPING AREA IN THE | | | IMMEDIATE VICINITY OF THE BEDROOMS. | | | 3. 3.ON EACH ADDITIONAL STORY OF THE DWELLING, | | | INCLUDING BASEMENTS AND HABITABLE ATTICS AND NOT | | | INCLUDING CRAWL SPACES AND UNINHABITABLE ATTICS. IN | | | DWELLINGS OR DWELLING UNITS WITH SPLIT LEVELS AND | | | WITHOUT AN INTERVENING DOOR BETWEEN THE ADJACENT | | | LEVELS, A SMOKE ALARM INSTALLED ON THE UPPER LEVEL | | | SHALL SUFFICE FOR THE ADJACENT LOWER LEVEL PROVIDED | | | THAT THE LOWER LEVEL IS LESS THAN ONE FULL STORY BELOW | | | THE UPPER LEVEL. | | | 4. 4.SMOKE ALARMS SHALL BE INSTALLED NOT LESS THAN 3 | | | FEET (914 MM) HORIZONTALLY FROM THE DOOR OR OPENING OF | | | A BATHROOM THAT CONTAINS A BATHTUB OR SHOWER UNLESS | | | THIS WOULD PREVENT PLACEMENT OF A SMOKE ALARM REQUIRED | | | BY SECTION R314.3 | | | | | | R314.4 INTERCONNECTION. | | | WHERE MORE THAN ONE SMOKE ALARM IS REQUIRED TO BE | | | INSTALLED WITHIN AN INDIVIDUAL DWELLING UNIT IN | | | ACCORDANCE WITH SECTION R314.3, THE ALARM DEVICES SHALL | | | BE INTERCONNECTED IN SUCH A MANNER THAT THE ACTUATION | | | OF ONE ALARM WILL ACTIVATE ALL OF THE ALARMS IN THE | | | INDIVIDUAL DWELLING UNIT. PHYSICAL INTERCONNECTION OF | | | SMOKE ALARMS SHALL NOT BE REQUIRED WHERE LISTED | | | WIRELESS ALARMS ARE INSTALLED AND ALL ALARMS SOUND UPON | | | ACTIVATION OF ONE ALARM. | | | | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
N |
Date |
2020-12-29 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2020-12-29 |
Time |
13:11 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2020-12-29 |
Time |
13:11 |
Sent To |
|
|
| Notes |
| 2020-12-29 13:11:16 | GAS PLAN REVIEW, A GAS PLAN HAS NOT BEEN INCLUDED IN | | | THIS SUBMITTAL PACKAGE. A GAS PLAN REVIEW HAS NOT BEEN | | | PERFORMED AT THIS TIME. A SEPARATE GAS PERMIT AND PLANS | | | WILL BE REQUIRED FOR A CONTRACTOR TO PERFORM THE | | | RELATED WORK. PROVIDE COMPLETE PLANS AND GAS RISER THAT | | | REFLECTS THE ENTIRE SCOPE OF GAS WORK TO BE DONE PER | | | THE WPB AMENDMENTS TO FBC SEC. 107.2.1. | | | | | | A SUB GAS PERMIT IS REQUIRED BY A LICENSED CONTRACTOR | | | FOR THE SCOPE OF WORK PER THE WPB AMENDMENTS TO THE FBC | | | SEC. 105.1. | | | |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
2 |
Status |
P |
Date |
2021-03-22 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2021-03-22 |
Time |
14:58 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2021-03-22 |
Time |
14:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
P |
Date |
2020-12-30 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2020-12-30 |
Time |
15:14 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2020-12-30 |
Time |
15:14 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2021-03-29 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-03-29 |
Time |
13:53 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-03-25 |
Time |
16:10 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2021-03-22 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2021-03-22 |
Time |
15:06 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2021-03-15 |
Time |
08:45 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2021-03-10 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-03-10 |
Time |
14:45 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-02-11 |
Time |
14:28 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2021-01-06 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-01-06 |
Time |
12:37 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2020-12-22 |
Time |
09:43 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
P |
Date |
2021-04-05 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2021-04-05 |
Time |
10:34 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2021-03-30 |
Time |
13:16 |
Sent To |
|
|
| Notes |
| 2021-04-05 10:35:13 | RECEIPT MU-2021-15466 - $0.00 DUE | | | | | 2021-03-30 13:16:51 | 3/30/21 EMAILED IMPACT OFFICE FOR REVIEW. LEM |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2021-01-06 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-01-06 |
Time |
12:24 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-01-06 |
Time |
12:24 |
Sent To |
|
|
| Notes |
| 2021-01-06 12:25:06 | PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE | | | DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS | | | OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST | | | FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE | | | OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL | | | IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME | | | THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM | | | CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS | | | TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF | | | | | | UPON APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE | | | RECEIPT TO YOUR PROJECT OR EMAIL IT TO | | | [email protected] . | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2021-02-22 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-02-22 |
Time |
14:57 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-02-22 |
Time |
14:48 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2020-12-31 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2020-12-31 |
Time |
14:17 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2020-12-31 |
Time |
13:26 |
Sent To |
|
|
| Notes |
| 2020-12-31 14:17:32 | 1ST REVIEW FBC-2017 MECHANICAL | | | PERMIT-20120024 | | | | | | CODES IN EFFECT: | | | | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | | 2017 | | | FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017 | | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | | 2017 | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH | | | EDITION 2017 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | | EDITION 2017 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) PLEASE IDENTIFY THE ROOMS ON THE MECHANICAL DRAWING. | | | IT APPEARS THAT THE LARGE ROOM ON THE LEFT SIDE OF THE | | | DRAWING HAS A DOOR, PLEASE SHOW THE RETURN AIR PATH | | | BACK TO THE AHU. FBC M 601.6 | | | | | | 2) PLEASE SHOW HOW THE CONDENSING UNIT WILL BE | | | ANCHORED. FBC RES M1307.2 | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE OLD | | | SHEETS FROM THE PLAN SETS, BIND THEM TOGETHER | | | SEPARATELY AND MARK VOID OR OLD ON THEM. PLEASE RETAIN | | | THEM FOR REFERENCE WITH THE NEW SUBMITTED PLANS. THIS | | | PROCESS WILL ALSO APPLY TO ANY DOCUMENTS SUCH AS | | | PRODUCT APPROVALS OR CALCULATIONS BEING REPLACED OR | | | UPDATED. | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2021-02-17 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2021-02-17 |
Time |
10:21 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2021-02-17 |
Time |
10:21 |
Sent To |
|
|
| Notes |
| 2021-02-17 10:21:58 | 02/17/21 REVIEWED FOR CODE COMPLIANCE (PLUMBING) | | | | | | BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE | | | COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN | | | PROFESSIONAL, CONTRACTORS, OR THEIR REPRESENTATIVES | | | FROM THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL, | | | STATE, AND NATIONAL CODES AND STANDARDS IN EFFECT AT | | | THE TIME OF PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK | | | OF EVERY ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM | | | REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES | | | / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO | | | AVOID VOIDING OF THE PERMIT. | | | | | | LUIS A. CRESPO | | | PLUMBING PLAN EXAMINER / INSPECTOR | | | EMAIL: [email protected] OFFICE: 561 805-6720 | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2020-12-29 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2020-12-29 |
Time |
13:03 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2020-12-29 |
Time |
12:02 |
Sent To |
|
|
| Notes |
| 2020-12-29 13:04:03 | 12/29/20 1ST PLUMBING REVIEW**DENIED** WITH COMMENTS | | | | | | NOTE - A COMPREHENSIVE REVIEW COULD NOT BE DONE AT THIS | | | TIME, AND ADDITIONAL PLAN REVIEW COMMENTS MAY BE | | | GENERATED UPON THE RE-REVIEW OF SUBMITTED CORRECTIONS. | | | | | | 1. ON SHEET S-1 ISOMETRIC; | | | | | | A. THE CABANA BATH TOILET NEEDS TO BE IN A BATHROOM | | | GROUP, NOT ON THE TRUNK LINE THAT RUNS TO THE SECOND | | | FLOOR PER THE 2017 FBC R 3109.1 WASTE STACK VENT | | | PERMITTED. | | | | | | B. ON THE SECOND FLOOR, THE WASHING MACHINE NEEDS TO BE | | | DOWN STEAM OF THE BATHROOM GROUP WHICH A THREE-INCH | | | DRAIN AND A TWO-INCH DISCHARGE ON THE DRAIN ARM PER THE | | | TABLE P3201.7 SIZE OF TRAPS FOR PLUMBING FIXTURES | | | | | | 2. HOT WATER PIPES NOT IN CONDITION SPACE SHALL BE | | | INSULATED WITH A MINIMUM R-3 PER THE 2017 FBC SEC. RE | | | 403.5.3. | | | | | | 3. A SUB PLUMBING AND GAS PERMIT IS REQUIRED BY A | | | LICENSED CONTRACTOR FOR THE SCOPE OF WORK PER THE WPB | | | AMENDMENTS TO THE FBC SEC. 105.1. | | | | | | WHEN RESUBMITTING PLANS, PLEASE INDICATE THE REVISION & | | | REMOVE ANY VOIDED SHEETS & REPLACE ANY NECESSARY PAGES. | | | A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW | | | COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | | THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR | | | PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | HTTPS://CODES.ICCSAFE.ORG/CODES/FLORIDA | | | | | | LUIS A. CRESPO | | | PLUMBING PLAN EXAMINER / INSPECTOR | | | EMAIL: [email protected] OFFICE: 561 805-6720 | | | |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
P |
Date |
2021-01-06 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-01-06 |
Time |
12:33 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-01-06 |
Time |
12:33 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
P |
Date |
2021-03-22 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-03-22 |
Time |
08:21 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-03-22 |
Time |
08:21 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2021-02-22 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-02-22 |
Time |
15:04 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-02-22 |
Time |
15:03 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2020-12-31 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2020-12-31 |
Time |
14:38 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2020-12-31 |
Time |
14:38 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2020-12-30 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2020-12-30 |
Time |
15:15 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2020-12-30 |
Time |
15:15 |
Sent To |
|
|
| Notes |
|
|