Plan Review Details - Permit 20111182
Plan Review Stops For Permit 20111182
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2021-07-14 Cont ID  
Sent By shill Date 2021-07-14 Time 16:55 Rev Time 0.00
Received By shill Date 2021-07-14 Time 16:55 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2021-06-18 Cont ID  
Sent By shill Date 2021-06-18 Time 16:00 Rev Time 0.00
Received By shill Date 2021-06-18 Time 11:16 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2021-07-21 Cont ID  
Sent By jleahy Date 2021-07-21 Time 17:21 Rev Time 0.00
Received By jleahy Date 2021-07-21 Time 17:19 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2021-05-25 Cont ID  
Sent By jleahy Date 2021-05-25 Time 15:00 Rev Time 0.00
Received By jleahy Date 2021-05-25 Time 14:46 Sent To  
Notes
2021-05-25 15:08:50ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 FLORIDA BUILDING CODE 2020 7TH EDITION
 FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 7TH ED
 NFPA 70 2017 EDITION
  
 JAKE LEAHY BN, BU, PX
 ELECTRICAL PLANS EXAMINER II
 561-805-6713
 [email protected]
  
 PANEL IN LIVING ROOM LOOKS TO BE IN A CLOSET.
 OVERCURRENT PROTECTION DEVICES ARE NOT PERMITTED IN THE
 VICINITY OF EASILY IGNITABLE MATERIAL, SUCH AS IN
 CLOTHES CLOSETS. PROVIDE CLARIFICATION AND/OR
 CORRECTION. NEC 240.24(D);
  
 ISLAND NEEDS AN OUTLET PER CODE.
 ISLAND COUNTERTOP SPACES. AT LEAST ONE RECEPTACLE SHALL
 BE INSTALLED AT EACH ISLAND COUNTERTOP SPACE WITH A
 LONG DIMENSION OF 600 MM (24 IN.) OR GREATER AND A
 SHORT DIMENSION OF 300 MM (12 IN.) OR GREATER
  
 SMOKE ALARMS ARE SHOWN TO CLOSE TO THE BATHROOM DOOR.
 SMOKE ALARM IS SHOWN TO CLOSE TO STOVE PLEASE CORRECT
 PER FBC R314.
  
 ARC FAULT PROTECTION REQUIRED PER 210.12(B)
  
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2021-07-21 Cont ID  
Sent By jleahy Date 2021-07-21 Time 17:22 Rev Time 0.00
Received By jleahy Date 2021-07-12 Time 11:55 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2021-06-18 Cont ID  
Sent By shill Date 2021-06-18 Time 16:00 Rev Time 0.00
Received By shill Date 2021-05-11 Time 16:19 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2021-05-25 Cont ID  
Sent By medwards Date 2021-05-25 Time 13:20 Rev Time 0.00
Received By medwards Date 2021-05-25 Time 13:20 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status P Date 2021-07-16 Cont ID  
Sent By ccole Date 2021-07-16 Time 09:47 Rev Time 0.00
Received By ccole Date 2021-07-16 Time 08:03 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2021-06-18 Cont ID  
Sent By tklarge Date 2021-06-18 Time 12:25 Rev Time 0.00
Received By tklarge Date 2021-06-18 Time 12:25 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2021-05-25 Cont ID  
Sent By ccole Date 2021-05-25 Time 14:12 Rev Time 0.00
Received By ccole Date 2021-05-25 Time 13:28 Sent To  
Notes
2021-05-25 14:12:371ST REVIEW FBC-2020 RES.
 PERMIT-20111182
 5/25/2021
  
 CODES IN EFFECT:
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION
 2020
 FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020
 FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION
 2020
 FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SHEET 001: THE PLUMBING SCOPE OF WORK INDICATES K &
 B FIXTURES REPLACED "AS SHOWN", HOWEVER THERE ARE NO
 FIXTURES SHOWN ON THE PLAN. PLEASE PROVIDE THE
 REFERENCED PLANS- SECTION 107.2.1 WPB.
  
 2) PLEASE NOTE THAT ALL PLUMBING PLANS THAT ARE
 SUBMITTED BY A FL. LICENSED ENGINEER OR ARCHITECT SHALL
 BE DIGITALLY SIGNED AND SEALED PER FL. STATUTES
 471.025, 481.221, AND SECTIONS 61G1-16.005,
 61G15-23.005 FAC. PLUMBING PLANS THAT ARE DRAWN BY THE
 PLUMBING CONTRACTOR OF RECORD FOR THE PROJECT SHALL
 BEAR THE PRINTED NAME, SIGNATURE AND LICENSE NUMBER OF
 THE CONTRACTOR OR QUALIFIER-SECTION 107.2.1 WPB, AND
 FLORIDA STATUTES 471.003(2)(H) & 471.025.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2021-07-21 Cont ID  
Sent By jleahy Date 2021-07-21 Time 17:21 Rev Time 0.00
Received By jleahy Date 2021-07-21 Time 17:21 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status N Date 2021-06-18 Cont ID  
Sent By shill Date 2021-06-18 Time 16:00 Rev Time 0.00
Received By shill Date 2021-06-18 Time 11:40 Sent To  
Notes
***NONE***